Aerodynamics of V/STOL aircraft powered by lift fans
Lift, drag, and pitching moments of large V/STOL aircraft models powered by lift fans determined in wind tunnel tests
SEARCH · Search NASA
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Lift, drag, and pitching moments of large V/STOL aircraft models powered by lift fans determined in wind tunnel tests
The aerodynamic characteristics of a large scale V/STOL transport model powered by tip-turbine driven lift fans were investigated. The model had four fans; the forward fans were mounted in pods forward of the wing at midsemispan. The aft fans were placed in cruise nacelles behind and above the wing. A cascade of variable camber exit louvers was placed behind each of the lift-cruise fans to turn the fan flow in the lift direction for hover and transition to wing supported flight. The wing of the model was mounted above the fuselage, had an aspect ratio of 5.8, sweepback of 35 deg at the quarter chord line and a taper ratio of 0.3. Various configurations of the model were tested to explore the transition speed range. Fan performance, turning effectiveness of the variable camber exit louvers, longitudinal and lateral-directional characteristics with fan operation in crossflow are presented.
This is one of a series of reports on the lessons learned from past research related to lift-fan aircraft concepts. An extensive review is presented of the many lift-fan aircraft design studies conducted by both government and industry over the past 45 years. Mission applications and design integration including discussions on manifolding hot gas generators, hot gas dusting, and energy transfer control are addressed. Past lift-fan evaluations of the Avrocar are discussed. Lessons learned from these past efforts are identified.
A lift fan exhaust suppression system to meet future VTOL aircraft noise goals was designed and tested. The test vehicle was a 1.3 pressure ratio, 36 inch (91.44 cm) diameter lift fan with two chord rotor to stator spacing. A two splitter fan exhaust suppression system thirty inches (76.2 cm) long achieved 10 PNdB exhaust suppression in the aft quadrant compared to a design value of 20 PNdB. It was found that a broadband noise floor limited the realizable suppression. An analytical investigation of broadband noise generated by flow over the treatment surfaces provided very good agreement with the measured suppression levels and noise floor sound power levels. A fan thrust decrement of 22% was measured for the fully suppressed configuration of which 11.1% was attributed to the exhaust suppression hardware.
Conceptual designs of V/STOL lift fan commercial short haul transport aircraft for the 1980-85 time period were studied to determine their technical and economic feasibility. The engine concepts included both integral and remote fans. The scope of the study included definition of the hover control concept for each propulsion system, aircraft design, aircraft mass properties, cruise performance, noise and ride qualities evaluation. Economic evaluating was also studied on a basis of direct operating costs and route structure.
Preliminary designs of three integral lift fan engines suitable for commercial certification in the 80's were completed. Emphasis was placed on low cost, simplicity, low noise, low emissions, minimum weight, and design features meeting all commercial standards for fire safety and containment.
Aerodynamic characteristics of large-scale model with lift fan mounted in 5 percent thick triangular wing
Aerodynamic characteristics of V/STOL transport model with wing-mounted lift fans - large-scale wind tunnel investigation
A statorless, turbotip lift fan was tested statically outdoors to determine its acoustic characteristics. Spectral and directivity results are presented with comparison to data from the same family of lift fan designs having stator vanes. Modifications to the fan were tested to evaluate circular inlet guide vanes and exhaust treatment. A comparison was made of results obtained at General Electric Edwards Flight Test Center and NASA Ames Research Center with regards to test data and differences in site characteristics.
Under a nonreimbursable space act agreement between the NASA Lewis Research Center and the Allison Advanced Development Company, Allison tested a lift fan nozzle in Lewis' Powered Lift Rig. This test was in support of the Joint Strike Fighter program (formerly the Joint Advanced Strike Technology) sponsored by the Department of Defense, which will develop and field an affordable, multirole, next-generation, strike fighter aircraft for the Navy, Air Force, Marine Corps, and foreign allies. Allison, along with Pratt & Whitney Company, is part of the Lockheed Martin Corporation team that is scheduled to build a concept demonstrator aircraft by fiscal year 2001. The test was initiated in April and successfully completed in mid-July of 1997. Allison supplied a one-third-scale model of the lift fan nozzle, and Lewis provided the facility and the necessary support team. Various configurations, including pitching vectored angles ranging from 15deg forward to 60deg backward, were tested over a range of nozzle pressure ratios. Nozzle flow rates, thrust, and static pressures were measured for each of the configurations. Results from the test met the design requirements for the Joint Strike Fighter program and were in agreement with Allison's internal computational fluid dynamics (CFD) analyses. Data obtained from this test will also be used in the full-scale design of the lift fan system.
An integrated propulsion/control system for lift-fan transport aircraft is described. System behavior from full-scale experimental and piloted simulator investigations are reported. The lift-fan transport is a promising concept for short-to-medium haul civil transportation and for other missions. The lift-fan transport concept features high cruise airspeed, favorable ride qualities, small perceived noise footprints, high utilization, transportation system flexibility, and adaptability to VTOL, V/STOL, or STOL configurations. The lift-fan transport has high direct operating costs in comparison to conventional aircraft, primarily because of propulsion system and aircraft low-speed control system installation requirements. An integrated lift-fan propulsion system/aircraft low-speed control system that reduces total propulsion system and control system installation requirements is discussed.
The location and appendages of a lift fan on a V/STOL aircraft are expected to have a measurable effect on fan performance. To study such installation effects, an experimental program was performed in which the individual performance of multiple VTOL model lift fans was measured. The model tested consisted of three 13.97-cm diameter tip-turbine driven model VTOL lift fans mounted chordwise in a two-dimensional wing to simulate a pod-type array. The performance data provided significant insight into possible thrust variations and losses caused by the presence of cover doors, adjacent fuselage panels, and adjacent fans. The effect of a partial loss of drive air supply on fan performance was also investigated.
The performance characteristics of a model VTOL lift-fan simulator installed in a two-dimensional wing are presented. The lift-fan simulator consisted of a 15-inch diameter fan driven by a turbine contained in the fan hub. The performance of the lift-fan simulator was measured in two ways: (1) the calculated momentum thrust of the fan and turbine (total thrust loading), and (2) the axial-force measured on a load cell force balance (axial-force loading). Tests were conducted over a wide range of crossflow velocities, corrected tip speeds, and wing angle of attack. A prediction modeling technique was developed to help in analyzing the performance characteristics of lift-fan simulators. A multiple linear regression analysis technique is presented which calculates prediction model equations for the dependent variables.
For lift-fan powered V/STOL aircraft, two unconventional propulsion system types were proposed. The first type uses fans connected by hot gas ducting, and the second type uses fans connected by cross shafting. An analytical study identified the basic steady-state and dynamic characteristics for each type of system. For the gas-coupled system, the control concepts analyzed were variable-area fan turbines and throttling valves in the ducting. For the shaft-coupled system, the control concepts analyzed were variable-pitch fans and variable fan inlet guide vanes. All of these concepts are capable of meeting V/STOL aircraft control moment and transient response requirements when appropriate propulsion controls are used.
The longitudinal aerodynamic characteristics of a six-fan, tip-driven (remote) lift-fan VTOL transport through transition were determined by an investigation conducted in the Langley V/STOL tunnel. Tests were also made with the large midspan lift-fan pods and lift-cruise fans removed to determine their their influence on the stability and control of the configuration. Data were obtained for a range of model height above ground.
This report summarizes the highlights and results of a workshop held at NASA Ames Research Center in October 1992. The objective of the workshop was a thorough review of the lessons learned from past research on lift fans, and lift-fan aircraft, models, designs, and components. The scope included conceptual design studies, wind tunnel investigations, propulsion systems components, piloted simulation, flight of aircraft such as the SV-5A and SV-5B and a recent lift-fan aircraft development project. The report includes a brief summary of five technical presentations that addressed the subject The Lift-Fan Aircraft: Lessons Learned.
Representatives of NASA Ames Research Center asked that a summary of technology appropriate for lift-fan powered short takeoff/vertical landing (STOVL) aircraft be prepared so that new programs could more easily benefit from past research efforts. This paper represents one of six prepared for that purpose. The authors have conducted or supervised the conduct of research on lift-fan powered STOVL designs and some of their important components for decades. This paper will first address aerodynamic modeling requirements for experimental programs to assure realistic, trustworthy results. It will next summarize the results or efforts to develop satisfactory specialized STOVL components such as inlets and flow deflectors. It will also discuss problems with operation near the ground, aerodynamics while under lift-fan power, and aerodynamic prediction techniques. Finally, results of studies to reduce lift-fan noise will be presented. The paper will emphasize results from large scale experiments, where available, for reasons that will be brought out in the discussion. Some work with lift-engine powered STOVL aircraft is also applicable to lift-fan technology and will be presented herein. Small-scale data will be used where necessary to fill gaps.
An investigation was conducted in the NASA-Ames 40 by 80 Foot Wind Tunnel to determine the aerodynamic characteristics of a large scale, VTOL, lift fan, jet transport model. The model had two lift fans at the forward portion of the fuselage, a lift fan at each wing tip, and two lift/cruise fans at the aft portion of the fuselage. All fans were driven by tip turbines using T-58 gas generators. Results were obtained for several lift fan, exit vane deflections and lift/cruise fan thrust deflections are zero sideslip. Three component longitudinal data are presented at several fan tip speed ratios. A limited amount of six component data were obtained with asymmetric vane settings. All of the data were obtained without a horizontal tail. Downwash angles at a typical tail location are also presented.