Search NASA⌕ Search

SEARCH · Search NASA

Results for “LIGHT INTENSITY”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Shockley-Read-Hall recombination in P3HT:PCBM solar cells as observed under ultralow light intensities

We present light intensity dependent measurements of the quantum efficiency of P3HT:PCBM photovoltaic devices. Unlike previous studies we focus on ultralow light intensities down to 10{sup -3} mW/cm{sup 2}. We find that although when the devices are excited at intensities close to 1 Sun they exhibit very little bias or light intensity dependence, this is clearly not the case for light intensities below 1 mW/cm{sup 2}, where the cell's efficiency becomes highly dependent on the bias and light intensity. Using a simple model for the device efficiency we can fit the experimental data across a wide range of parameters and thus separate the effects of generation efficiency (geminate recombination) and charge recombination. Our finding suggests that recombination through trap (charge transfer) states is an important loss mechanism and we are able to quantify the density and depth of these states.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

The effect of low light intensity on the maintenance of circadian synchrony in human subjects

The light-intensity threshold for humans is not known. In past space flights owing to power restrictions, light intensities have been minimal and reported to be as low as 15 ft. c. This study was conducted to determine whether the light (L)/dark (D) environment of 16L : 8D at the relatively low light intensity of 15 ft. c. was adequate for the maintenance of circadian synchrony in human subjects. Six healthy male subjects aged 20-23 years were exposed for 21 days to a 16L : 8D photoperiod. During the first 7 days the light intensity was 100 ft. c.; it was reduced to 15 ft. c. during the next 7 days and increased again to 100 ft. c. during the last 7 days of the study. Rectal temperature (RT) and heart rate (HR) were recorded continuously throughout the 21 days of the study. In the 100 ft. c. 16L : 8D the RT and HR rhythms remained stable and circadian throughout. When the light intensity was decreased to 15 ft. c. the periodicity of the HR rhythm was significantly decreased and this rhythm showed marked instability. In contrast the period of the RT rhythm did not change but a consistent phase delay occurred due to a delay in the lights-on associated rise in RT. These divergent effects on these two rhythms in internal desynchronization and performance decrement during the 15 ft. c. exposure. The data emphasize the need for establishing accurately the minimal lighting requirements for the maintenance of circadian rhythms of humans in confined environments.

Circadian Rhythm/physiology/radiation effects↗

Numerical evaluation of droplet sizing based on the ratio of fluorescent and scattered light intensities (LIF/Mie technique)

The dependence of fluorescent and scattered light intensities from spherical droplets on droplet diameter was evaluated using Mie theory. The emphasis is on the evaluation of droplet sizing, based on the ratio of laser-induced fluorescence and scattered light intensities (LIF/Mie technique). A parametric study is presented, which includes the effects of scattering angle, the real part of the refractive index and the dye concentration in the liquid (determining the imaginary part of the refractive index). The assumption that the fluorescent and scattered light intensities are proportional to the volume and surface area of the droplets for accurate sizing measurements is not generally valid. More accurate sizing measurements can be performed with minimal dye concentration in the liquid and by collecting light at a scattering angle of 60 deg. rather than the commonly used angle of 90 deg. Unfavorable to the sizing accuracy are oscillations of the scattered light intensity with droplet diameter that are profound at the sidescatter direction (90 deg.) and for droplets with refractive indices around 1.4.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Investigation on the similarity law of low-pressure glow discharges based on the light intensity distributions in geometrically similar gaps

Experimental investigation of the light intensity distributions of a low-pressure glow discharge is carried out in several pairs of geometrically similar plane-parallel gaps, of which the aspect ratios and the products of the linear dimension and the gas pressure are the same. The discharge images are captured using a Charge Coupled Device camera, from which the corresponding axial light intensity distributions are presented. Based on the obtained light intensity distributions, the thicknesses of cathode fall layers were identified by measuring the distance between the peak glow position and the cathode boundary. The influence of the discharge current on the light intensity distributions on the geometrically similar gaps is also investigated. It was found that, for discharges in each pair of geometrically similar gaps, the reduced cathode fall thicknesses are observed to be identical when the discharge currents are the same. In conclusion, the similarity relation of the cathode fall thickness is validated for low-pressure glow discharges in gaps for different aspect ratios.

42 ENGINEERING↗

Variation in light intensity with height and time from subsequent lightning return strokes

Photographic measurements of relative light intensity as a function of height and time have been conducted for seven return strokes in two lightning flashes at 7.8 and 8.7 km ranges, using film which possesses an approximately constant spectral response in the 300-670 nm range. The amplitude of the initial light peak is noted to decrease exponentially with height, with a decay constant of 0.6-0.8 km. The logarithm of the peak light intensity near the ground is found to be approximately proportional to the initial peak electric field intensity, implying that the current decrease with height may be much slower than the light decrease. Absolute light intensity is presently estimated through the integration of the photographic signals from individual channel segments, in order to simulate the calibrated, all-sky photoelectric data of Guo and Krider (1982).

Jordan, D. M.↗

Correlated peak relative light intensity and peak current in triggered lightning subsequent return strokes

The correlation between peak relative light intensity L(R) and stroke peak current I(R) is examined for 39 subsequent return strokes in two triggered lightning flashes. One flash contained 19 strokes and the other 20 strokes for which direct measurements were available of the return stroke peak current at ground. Peak currents ranged from 1.6 to 21 kA. The measurements of peak relative light intensity were obtained from photographic streak recordings using calibrated film and microsecond resolution. Correlations, significant at better than the 0.1 percent level, were found for several functional relationships. Although a relation between L(R) and I(R) is evident in these data, none of the analytical relations considered is clearly favored. The correlation between L(R) and the maximum rate of current rise is also examined, but less correlation than between L(R) and I(R) is found. In addition, the peak relative intensity near ground is evaluated for 22 dart leaders, and a mean ratio of peak dart leader to peak return stroke relative light intensity was found to be 0.1 with a range of 0.02-0.23. Using two different methods, the peak current near ground in these dart leaders is estimated to range from 0.1 to 6 kA.

Idone, V. P.↗

HYDROGEN PRODUCTION BY THE CYANOBACTERIUM PLECTONEMA BORYANUM: EFFECTS OF INITIAL NITRATE CONCENTRATION, LIGHT INTENSITY, AND INHIBITION OF PHOTOSYSTEM II BY DCMU

The alarming rate at which atmospheric carbon dioxide levels are increasing due to the burning of fossil fuels will have incalculable consequences if disregarded. Fuel cells, a source of energy that does not add to carbon dioxide emissions, have become an important topic of study. Although signifi cant advances have been made related to fuel cells, the problem of cheap and renewable hydrogen production still remains. The cyanobacterium Plectonema boryanum has demonstrated potential as a resolution to this problem by producing hydrogen under nitrogen defi cient growing conditions. Plectonema boryanum cultures were tested in a series of experiments to determine the effects of light intensity, initial nitrate concentration, and photosystem II inhibitor DCMU (3-(3,4- dichlorophenyl)-1,1-dimethylurea) upon hydrogen production. Cultures were grown in sterile Chu. No. 10 medium within photobioreactors constantly illuminated by halogen lights. Because the enzyme responsible for hydrogen production is sensitive to oxygen, the medium was continuously sparged with argon/CO2 (99.7%/0.3% vol/vol) by gas dispersion tubes immersed in the culture. Hydrogen production was monitored by using a gas chromatograph equipped with a thermal conductivity detector. In the initial experiment, the effects of initial nitrate concentration were tested and results revealed cumulative hydrogen production was maximum at an initial nitrate concentration of 1 mM. A second experiment was then conducted at an initial nitrate concentration of 1 mM to determine the effects of light intensity at 50, 100, and 200 μmole m-2 s-1. Cumulative hydrogen production increased with increasing light intensity. A fi nal experiment, conducted at an initial nitrate concentration of 2 mM, tested the effects of high light intensity at 200 and 400 μmole m-2 s-1. Excessive light at 400 μmole m-2 s-1 decreased cumulative hydrogen production. Based upon all experiments, cumulative hydrogen production rates were optimal at an initial nitrate concentration of 1 mM and a light intensity of 100 μmole m-2 s-1. DCMU was shown in all experiments to severely decrease hydrogen production as time progressed. With the information acquired so far, future experiments with reducing substances could determine maximum rates of hydrogen production. If maximum hydrogen production rates proved to be large enough, Plectonema boryanum could be grown on an industrial scale to provide hydrogen gas as a renewable fuel.

Carter, B↗

Influence of Different Light Sources, Light Intensities, and Water Flow Lens (WFL) System on Dye-Sensitized Solar Cell Performances

Recently, dye-sensitized solar cells demonstrated a superior performance under ambient light conditions. In this study, the influence on dye-sensitized solar cell performances was investigated under different light sources, light intensity, spectra, and water flow lens (WFL) system. Three types of light sources (xenon, halogen, and tungsten) with various spectral distributions (spectra) were used. Dyes-sensitized solar cells with varied sensitizers and co-sensitizers were tested depending on the light sources. Higher efficiency was obtained under irradiance of tungsten and halogen lamp in comparison to the xenon lamp, specifically at lower light intensities. Additionally, a new way of spectral adjustment was demonstrated. The use of a WFL system changes the distribution of spectra and remarkably influence for better performances of solar cells and efficiency values up to 30%. The results revealed that at lower light intensity, the influence of spectra was dominant and by changing spectral distribution various values of efficiency can be obtained. Also, a great influence on solar cells characteristics had a light source used for measurements. IEEE.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗