Toroidal mirrors provide virtual walls for breaks in light pipes

Section of light pipe consists of separated segments having opposed toroidal mirrors that intercept meridional rays to present virtual wall in space between mirrors, thus insuring uninterrupted light transmission down the pipe. Design affords internal access to pipe section. Segments are electrically or thermally insulated from one another.

Young, N.↗

Laser action generated within a light pipe: A concept

Laser light could be generated within light pipe itself, thereby eliminating coupling losses. Theoretical calculations have shown feasibility of light-pipe laser propagating in circularly-polarized TE mode. It is predicted that fiber-optic distributed-feedback laser would have gain on order of 25 dB.

Elachi, C.↗

Light pipes for LED measurements

Light pipe directly couples LED optical output to single detector. Small area detector measures total optical output of diode. Technique eliminates thermal measurement problems and channels optical output to remote detector.

Floyd, S. R.↗

Evaluation of clad scintillating light pipes

Arrays of fibers made of scintillating material were used as position-sensitive detectors or hodoscopes for beam-finding at ion accelerators. Experiments were made with alpha's from an Am241 source incident upon one end of the fiber, the other end being viewed with a photomultiplier tube. The scintillation light was not detected in any of the fibers tested beyond about 5 cm. The effective useful lengths for detection of relativistic heavy ions were given.

Source record↗

Scintillating plastic fibers as light pipes for a cosmic ray hodoscope: Feasibility calculations and measured attenuation characteristics

A candidate hodoscope uses arrays of scintillator fibers, followed by an image intensifier and imaging system such as that proposed for the X-ray shadowgraph. A literature search was performed to ascertain the experience of other workers with hodoscopes using this or similar principles. Calculations were performed to determine the feasibility of candidate systems and some laboratory experiments were performed to attempt to check these numbers.

Source record↗

Use of prismatic films to control light distribution

Piping light for illumination purposes is a concept which has been around for a long time. In fact, it was the subject of an 1881 United States patent which proposed the use of mirrors inside a tube to reflect light from wall to wall down the tube. The use of conventional mirrors for this purpose, however, has not worked because mirrors do not reflect well enough. On the other hand, optical fibers composed of certain glasses or plastics are known to transport light much more efficiently. The light that enters is reflected back and forth within the walls of the fiber until it reaches the other end. This is possible by means of a principle known as 'total internal reflection'. No light escapes through the walls and very little is absorbed in the bulk of the fiber. However, while optical fibers are very efficient in transporting light, they are impractical for transporting large quantities of light. Lorne Whitehead, as a student at the University of British Columbia, recognized that prismatic materials could be used to create a 'prism light guide', a hollow structure that can efficiently transport large quantities of light. This invention is a pipe whose transparent walls are formed on the outside into precise prismatic facets. The facets are efficient total internal reflection mirrors which prevent light travelling down the guide from escaping. Very little light is absorbed by the pipe because light travels primarily in the air space within the hollow guide. And, because the guide is hollow, weight and cost factors are much more favorable than would be the case with very large solid fibers. Recent advances in precision micromachining, polymer processing, and certain other manufacturing technologies have made the development of OLF (Optical Lighting Film) possible. The process is referred to as 'microreplication' and has been found to have broad applicability in a number of diverse product areas.

Kneipp, K. G.↗

Noncontact measurement of high temperature using optical fiber sensors

The primary goal of this research program was the investigation and application of noncontact temperature measurement techniques using optical techniques and optical fiber methods. In particular, a pyrometer utilizing an infrared optical light pipe and a multiwavelength filtering approach was designed, revised, and tested. This work was motivated by the need to measure the temperatures of small metallic pellets (approximately 3 mm diameter) in free fall at the Microgravity Materials Processing Drop Tube at NASA Marshall Space Flight Center. In addition, research under this program investigated the adaptation of holography technology to optical fiber sensors, and also examined the use of rare-earth dopants in optical fibers for use in measuring temperature. The pyrometer development effort involved both theoretical analysis and experimental tests. For the analysis, a mathematical model based on radiative transfer principles was derived. Key parameter values representative of the drop tube system, such as particle size, tube diameter and length, and particle temperature, were used to determine an estimate of the radiant flux that will be incident on the face of an optical fiber or light pipe used to collect radiation from the incandescent falling particle. An extension of this work examined the advantage of inclining or tilting the collecting fiber to increase the time that the falling particle remains in the fiber field-of-view. Those results indicate that increases in total power collected of about 15 percent may be realized by tilting the fiber. In order to determine the suitability of alternative light pipes and optical fibers, and experimental set-up for measuring the transmittance and insertion loss of infrared fibers considered for use in the pyrometer was assembled. A zirconium fluoride optical fiber and several bundles of hollow core fiber of varying diameters were tested. A prototype two-color pyrometer was assembled and tested at Virginia Tech, and then tested on the Drop Tube at Marshall Space Flight Center. Radiation from 5 mm diameter niobium drops falling in the Drop Tube was successfully detected, and recorded for later analysis. Subsequent analysis indicated that the imaging of light output from the light pipe onto the detector active areas was not identical for both detectors.

Claus, R. O.↗

Solar energy trap

An apparatus is described for trapping solar energy for heating a fluid that could be subsequently used in turbines and similar devices. The apparatus includes an elongated vertical light pipe having an open end through which the visible spectrum of electromagnetic radiation from the sun passes to strike a tubular absorber. The light pipe has a coated interior surface of a low absorptivity and a high reflectivity at the visible wavelengths and a high absorptivity/emissivity ratio at infrared wavelengths. The tubular absorber has a coating on the surface for absorbing visible wavelengths to heat the fluid passing through. Infrared wave lengths are radiated from the tubular absorber back into the light pipe for heating fluid passing through a tubular coil wound around it.

Brantley, L. W., Jr.↗

Improved Thermal-Diffusivity-Measuring Apparatus

Accuracy at high temperature improved. Furnace heats specimen to experimental temperature, and flash tube raises specimen temperature by small amount and for short time so diffusivity (composite property of heat capacity and conductivity) determined. Specimen mount ensures minimum heat loss during temperature-rise measurement. Measurement temperatures up to 1,000 degrees C realized with fused-quartz light pipe and up to 1,600 degrees C with sapphire light pipe.

Wood, C.↗

The specific light output of cesium iodide crystals

Large area ion chambers for a high energy cosmic ray experiment, scintillating plastic fibers as light pipes for a cosmic ray hodoscope, and an evaluation of clad scintillating light pipes were considered.

Gregory, J. C.↗

High Conductivity Carbon-Carbon Heat Pipes for Light Weight Space Power System Radiators

Based on prior successful fabrication and demonstration testing of a carbon-carbon heat pipe radiator element with integral fins this paper examines the hypothetical extension of the technology via substitution of high thermal conductivity composites which would permit increasing fin length while still maintaining high fin effectiveness. As a result the specific radiator mass could approach an ultimate asymptotic minimum value near 1.0 kg/m2, which is less than one fourth the value of present day satellite radiators. The implied mass savings would be even greater for high capacity space and planetary surface power systems, which may require radiator areas ranging from hundreds to thousands of square meters, depending on system power level.

Juhasz, Albert J.↗

Using APART for wall visibility calculations in the calibration channel of wide field planetary camera II

The cone visibility from the CCD detector array plane in the calibration channel of wide field planetary camera II (WFPC II) is analyzed, using APART, for three representative wavelengths as characterized by indices of refraction. The light pipe walls are visible from the corners of the equivalent CCD detector array when imaging with the smallest index of refraction, n = 1.375. Painting the inside of the light pipe walls will result in a decrease in their visibility.

Scholl, James W.↗

Rare Earth Optical Temperature Sensor

A rare earth optical temperature sensor is disclosed for measuring high temperatures. Optical temperature sensors exist that channel emissions from a sensor to a detector using a light pipe. The invention uses a rare earth emitter to transform the sensed thermal energy into a narrow band width optical signal that travels to a detector using a light pipe. An optical bandpass filter at the detector removes any noise signal outside of the band width of the signal from the emitter.

Donald L Chubb↗

Noncontacting devices to indicate deflection and vibration of turbopump internal rotating parts

The research is reported which was conducted to develop devices for measuring vibrations and deflections of parts, such as impellers, shafts, turbine wheels, and inducers in operating turbopumps. Three devices were developed to the breadboard stage: ultrasonic Doppler transducer, flash X-rays, and light-pipe reflectance. It was found that the X-ray technique is applicable to the shaft assembly and the turbine seal of the J-2 pump, and the light-pipe-reflectance device appears to be ideal for cryogenic pump sections.

Hamilton, D. B.↗

Noncontacting device to indicate deflection of turbopump internal rotating parts

Phase 2 (development) which was concluded for the ultrasonic Doppler device and the light-pipe-reflectance device is reported. An ultrasonic Doppler breadboard system was assembled which accurately measured runout in the J-2 LOX pump impeller during operation. The transducer was mounted on the outside of the pump volute using a C-clamp. Vibration was measured by conducting the ultrasonic wave through the volute housing and through the fluid in the volute to the impeller surface. The impeller vibration was also measured accurately using the light-pipe probe mounted in an elastomeric-gland fitting in the pump case. A special epoxy resin developed for cryogenic applications was forced into the end of the fiber-optic probe to retain the fibers. Subsequently, the probe suffered no damage after simultaneous exposure to 2150 psi and 77 F. Preliminary flash X-radiographs were taken of the turbine wheel and the shaft-bearing-seal assembly, using a 2-megavolt X-ray unit. Reasonable resolution and contrast was obtained. A fast-neutron detector was fabricated and sensitivity was measured. The results demonstrated that the technique is feasible for integrated-time measurements requiring, perhaps, 240 revolutions to obtain sufficient exposure at 35,000 rpm. The experimental verification plans are included.

Hamilton, D. B.↗

Pioneer-Venus large probe infrared radiometer /LIR/ optical system

The LIR (large probe infrared radiometer) instrument has been developed for the NASA Ames Research Center for use in the 1978 Venus Atmospheric Probe Mission. The mission objectives are to determine the nature and composition of the clouds, the composition and structure of the atmosphere, and the atmospheric circulation pattern of the planet Venus. The LIR is a six-channel (3-50 micron) internally calibrated radiometer which measures the radiance difference at plus or minus 45 deg to the horizontal as viewed through a single diamond window in the spacecraft. The LIR optical system consists of a unique arrangement of hollow light pipes which optically couple a six element detector/filter array to the spacecraft window while mechanically and thermally isolating the array from the window's harsh thermal environment. A single rotating section with a 45 deg bend and containing a collimator alternately views up and down through director/extender pipes located adjacent to the diamond window. Light is transferred from the rotating section to a fixed section containing a diamond diffuser to scramble the light. This minimizes asymmetries and improves channel field of view overlap.

Brown, F. G.↗

Application of infrared radiometers for airborne detection of clear air turbulence and low level wind shear, airborne infrared low level wind shear detection test

The feasibility of infrared optical techniques for the advance detection and avoidance of low level wind shear (LLWS) or low altitude wind shear hazardous to aircraft operations was investigated. A primary feasibility research effort was conducted with infrared detectors and instrumentation aboard the NASA Ames Research Center Learjet. The main field effort was flown on the NASA-Ames Dryden B57B aircraft. The original approach visualized a forward-looking, infrared transmitting (KRS-5) window through which signals would reach the detector. The present concept of a one inch diameter light pipe with a 45 deg angled mirror enables a much simpler installation virtually anywhere on the aircraft coupled with the possibility of horizontal scanning via rotation of the forward directed mirror. Present infrared detectors and filters would certainly permit ranging and horizontal scanning in a variety of methods. CRT display technology could provide a contoured picture with possible shear intensity levels from the infrared detection system on the weather radar or a small adjunct display. This procedure shoud be further developed and pilot evaluated in a light aircraft such as a Cessna 207 or equivalent.

Kuhn, P. M.↗