Search NASA⌕ Search

SEARCH · Search NASA

Results for “LIGHTING EQUIPMENT”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Standard Measurement & Verification Plan for Lighting Equipment Retrofit or Replacement Projects

This document provides a framework for a standard Measurement and Verification (M&V) plan for lighting projects. It was developed to support cost-effective retrofits (partial and complete replacements) of lighting systems and is intended to provide a foundation for an M&V plan for a lighting retrofit utilizing a "best practice" approach, and to provide guidance to site owners, contractors, and other involved organizations on what is essential for a robust M&V plan for lighting projects. This document provides examples of appropriate elements of an M&V plan, including the calculation of expected energy savings. The standard M&V plan, as provided, also allows for consistent comparison with other similar lighting projects. Although intended for lighting retrofit applications, M&V plans developed per this framework document may also be used for other non-lighting technology retrofits and new installations.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

White Paper on Energy Efficiency Status of Energy-Using Products in China (2011)

This White Paper focuses on the areas and products involved in the above tasks, based on the White Paper - Energy Efficiency Status of Energy-Using Products in China (2010), here referred to as “White Paper 2010”, which analyzed the energy efficiency status of 21 typical energy-using products in five sectors: household appliances, office equipment, commercial equipment, industrial equipment, and lighting equipment. Table 1 illustrates the detailed product coverage for this year’s paper, noting the addition of three household appliance items (automatic electric rice cooker, AC electric fan, and household induction cooktop) and one industrial sector item (three-phase distribution transformer).

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Simulation Analyses in Support of DOE’s Fossil Fuel Rule for Single Component Equipment and Lighting Replacements

At the request of the US Department of Energy’s (DOE) Federal Energy Management Program (FEMP), Pacific Northwest National Laboratory (PNNL) conducted a series of building energy simulations using a large office model to investigate the potential savings that could be accrued from a typical chiller, boiler, or lighting replacement in a Federal office building. FEMP’s interest was in knowing whether or not single component replacements like these would have any chance of achieving the fossil- fuel-based energy consumption reduction requirements specified in Section 433 of the Energy Independence and Security Act (EISA) of 20071. Specifically, FEMP was interested in whether an older Federal building, built in the 1980s or 1990s and designed to meet energy standards in place at the time the building was designed, could meet the requirements of Section 433 of EISA for renovations. Many single component renovations like chiller replacements, boiler replacements, and lighting retrofits may meet the minimum cost requirement of Section 433 of EISA but may not offer any opportunity to achieve fossil-fuel-generated energy consumption reductions on the order of 55% or more. If single component renovations such as these would not achieve the necessary reductions, then FEMP would consider modifying rules based on Section 433 of EISA to exempt these types of single component renovations from the overall fossil-fuel-generated energy consumption reduction provisions. FEMP would instead require Federal agencies to ensure that these renovations use FEMP-designated efficiencies for chillers and boilers or the lighting power density requirements found in ASHRAE Standard 90.1-2010. The results of PNNL’s analysis indicated that it is unlikely that a combined boiler and chiller replacement, or an individual boiler or chiller replacement in an older existing Federal building would meet the requirements of Section 433 of EISA. While buildings can achieve up to 34% reduction in cooling and 11% reduction in heating load with this type of retrofit, these savings fall well short of the minimum savings specified in Section 433 of EISA. Similarly, a lighting retrofit in an older existing Federal building would also not likely meet the requirements of Section 433 of EISA. While buildings can save up to 52% on lighting loads, the whole buildings savings would be well short of the minimum savings specified in Section 433 of EISA.

Halverson, Mark A.↗

RNA‐Seq analysis revealed the molecular mechanisms of photobiomodulation effect on human fibroblasts

Abstract Background The photobiomodulation (PBM) effect has been applied to various clinical therapy for a long time. However, the mechanism related to the PBM effect in terms of wavelengths has been lack of in‐depth study, except that ultraviolet radiation has attracted much attention due to its strong cell‐killing effect. Purpose To clarify the principle behind PBM and the main mechanism of improvement. Methods To carry on this study, we created light equipment using three LED chips, which emit 390 nm ultraviolet radiation, 415 nm blue light and 660 nm red light, respectively. We choose human fibroblasts (HF) to be irradiated by three different wavelengths for PBM test. In this study, we used cell counting kit (CCK‐8) test to show the cell proliferation roughly and reported on a systematic RNA sequencing (RNA‐seq) analysis at transcriptional expression levels from HF, which accepted PBM of different wavelengths of light. Results We found that 415 nm blue light inhibited cell proliferation and 660 nm red light stimulated cell proliferation while 390 nm ultraviolet radiation has little influence on cell proliferation. Furthermore, RNA‐seq results showed that CSF1R, PPP3CC, ITGAL, ITGAM, IL2RB, and several other differentially expressed genes (DEGs) are involved in the cell proliferation. Relative DEGs values for matrix metalloproteinases (MMPs) gene family have shown a great difference in blue and red light radiation especially on MMP25, MMP9, MMP21, and MMP13. Conclusion Taken together, the results provide a valuable resource to describe the variation of HFs under PBM of different light at gene level.

Li, Wenqi↗

Chapter 2: Commercial and Industrial Lighting Evaluation Protocol. The Uniform Methods Project: Methods for Determining Energy Efficiency Savings for Specific Measures

The Commercial and Industrial Lighting Evaluation Protocol (the protocol) describes methods to account for gross energy savings resulting from the programmatic installation of efficient lighting equipment in large populations of commercial, industrial, and other nonresidential facilities. This protocol does not address savings resulting from changes in codes and standards, or from education and training activities. A separate Uniform Methods Project (UMP) protocol, Chapter 3: Commercial and Industrial Lighting Controls Evaluation Protocol, addresses methods for evaluating savings resulting from lighting control measures such as adding time clocks, tuning energy management system commands, and adding occupancy sensors.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Management of waste electrical and electronic equipment in two EU countries: A comparison

Highlights: Black-Right-Pointing-Pointer Review on data regarding WEEE management in Italy and in Romania. Black-Right-Pointing-Pointer Problems that countries that will enter in the EU will have to solve facing with the WEEE management. Black-Right-Pointing-Pointer Pilot experiences useful for the awareness campaign of the population. - Abstract: The paper presents some data regarding waste electrical and electronic (WEEE) management in one of the founding countries of the EU, Italy, and in a recent entry into the EU, Romania. The aim of this research was to analyze some problems that countries entering the EU will have to solve with respect to WEEE management. The experiences of Italy and Romania could provide an interesting reference point. The strengths and weaknesses that the two EU countries have encountered can be used in order to give a more rational plan for other countries. In Italy the increase of WEEE collection was achieved in parallel with the increase of the efficiency of selective Municipal Solid Waste collection. In Romania, pilot experiences were useful to increase the awareness of the population. The different interests of the two populations towards recyclable waste led to a different scenario: in Romania all types of WEEE have been collected since its entrance into the EU; in Italy the 'interest' in recycling is typically related to large household appliances, with a secondary role of lighting equipment.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Energy and economic impacts of U.S. federal energy and water conservation standards adopted from 1987 through 2024

This paper presents estimates of the key impacts of U.S. national energy and water conservation standards adopted from 1987 through 2024. The standards for consumer products, commercial and industrial equipment, lighting products, and plumbing products include those set by legislation as well as standards adopted by the Department of Energy (DOE) through rulemaking. In 2024 alone, these standards are estimated to have saved an estimated 6.0 quads of primary energy, which is equivalent to 6.5% of total U.S. energy consumption, and 1.7 trillion gallons of water, which is equivalent to approximately 12% of the annual water withdrawals for public supply in the U.S in 2015. The estimated reduction in CO 2 emissions associated with the standards in 2024 was 270 million metric tons, which is equivalent to 5.6% of total annual U.S. CO 2 emissions from energy consumption. The annual savings in operating costs for households and businesses totaled $\$$105 billion, and the average household saved $\$$576 in operating costs as a result of standards on residential appliances and plumbing products. The estimated cumulative past and future energy and water savings from these standards amount to 307 quads of energy and almost 53 trillion gallons of water. The estimated cumulative CO 2 emissions reduction from the standards come to 10.3 billion metric tons. Accounting for the increased upfront costs of more-efficient products and the energy and water cost savings over the products’ lifetime, the standards have a cumulative net present value of benefit of $\$$3.2 trillion using 3 percent discount rate and $\$$3.5 trillion using 7 percent discount rate when discounting past and future benefits to 2024.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Energy Performance Assessment of Radiant Cooling System through Modeling and Calibration at Component Level

The paper describes a case study of an information technology office building with a radiant cooling system and a conventional variable air volume (VAV) system installed side by side so that performancecan be compared. First, a 3D model of the building involving architecture, occupancy, and HVAC operation was developed in EnergyPlus, a simulation tool. Second, a different calibration methodology was applied to develop the base case for assessing the energy saving potential. This paper details the calibration of the whole building energy model to the component level, including lighting, equipment, and HVAC components such as chillers, pumps, cooling towers, fans, etc. Also a new methodology for the systematic selection of influence parameter has been developed for the calibration of a simulated model which requires large time for the execution. The error at the whole building level [measured in mean bias error (MBE)] is 0.2%, and the coefficient of variation of root mean square error (CvRMSE) is 3.2%. The total errors in HVAC at the hourly are MBE = 8.7% and CvRMSE = 23.9%, which meet the criteria of ASHRAE 14 (2002) for hourly calibration. Different suggestions have been pointed out to generalize the energy saving of radiant cooling system through the existing building system. So a base case model was developed by using the calibrated model for quantifying the energy saving potential of the radiant cooling system. It was found that a base case radiant cooling system integrated with DOAS can save 28% energy compared with the conventional VAV system.

Building Energy Simulation↗

Building Agent™ Software (BA) [SWRs 12-05 and 17-21]

Energy interfaces provide a new level of motivational information. Many studies have reported energy savings after dashboards for operators are installed, but these provide little actionable information to the occupant and the occupant cannot report individual comfort. The Building Agent™ (BA), in development at the National Renewable Energy Laboratory (NREL), provides an interface for the occupant to converse with the building control system and aims to actively engage and affect occupant behavior to achieve positive energy outcomes. Energy savings achieved via occupant behavioral changes could be as high as 25%, and could rival savings achieved by technological measures. For example, energy audits often show that more than 50% of the energy used in a building is consumed at night. Occupants leaving equipment and lighting on after they leave work is a large contributing factor. Similar savings opportunities have been identified when occupants were away from their desks 50% of the time, while most of their computers, lights, and other equipment remained powered on. Building Agent aims to create cohesion between building automation system (BAS) data, local measurements, and occupant feedback to provide visualizations, empowering occupants and building engineers to take diagnostic, proactive, energy-saving, and comfort-improving actions. The multilayer BA architecture consists of central server, measurement, and distributed application layers. The server layer aggregates global and localized measurements with occupant feedback to correlate perceived comfort with actual data throughout the building. The measurement layer complements BAS data with localized, environmental condition measurements at workstations. The application layer provides a bidirectional communications mechanism between the building and the occupants that accepts comfort feedback and provides energy performance information. The interface layer also uses three displays to influence building energy use: empathetic and personalized gauges, graphical data, and competitive rankings. Building Agent was implemented at NREL in the Research Support Facility (RSF), a LEED Platinum and Net Zero office building, which has received many awards. The constant feedback from occupants has enabled BA to better enhance the BAS data controls. Continued work is being done on BA to increase visualization of data and enhanced the user experience.

Long, Nicholas↗

Minimizing lighting power density in office rooms equipped with Anidolic Daylighting Systems

Electric lighting is responsible for up to one third of an office building's electricity needs. Making daylight more available in office buildings can not only contribute to significant energy savings but also enhance the occupants' performance and wellbeing. Anidolic Daylighting Systems (ADS) are one type of very effective facade-integrated daylighting systems. All south-facing office rooms within the LESO solar experimental building in Lausanne (Switzerland) are equipped with a given type of ADS. A recent study has shown that these offices' occupants are highly satisfied with their lighting environment. The most energy-efficient south-facing offices have a lighting power density of less than 5W/m{sup 2}. The lighting situation within these ''best practice''-offices has been assessed using the lighting simulation software RELUX Vision. Because this lighting situation is very much appreciated by the occupants, it was used as a starting point for developing even more energy-efficient office lighting designs. Two new lighting designs, leading to lighting power densities of 3.9W/m{sup 2} and 3W/m{sup 2}, respectively, have been suggested and simulated with RELUX Vision. Simulation results have shown that the expected performances of these new systems are comparable to that of the current lighting installation within the ''best practice''-offices or even better. These simulation results have been confirmed during experiments on 20 human subjects in a test office room recently set up within the LESO building. This article gives engineers, architects and light planers valuable information and ideas on how to design energy-efficient and comfortable electric lighting systems in office rooms with abundant access to daylight. (author)

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Chapter 16: Retrocommissioning Evaluation Protocol. The Uniform Methods Project: Methods for Determining Energy Efficiency Savings for Specific Measures

Retrocommissioning (RCx) is a systematic process for optimizing energy performance in existing buildings. It specifically focuses on improving the control of energy-using equipment (e.g., heating, ventilation, and air conditioning [HVAC] equipment and lighting) and typically does not involve equipment replacement. Field results have shown proper RCx can achieve energy savings ranging from 5 percent to 20 percent, with a typical payback of two years or less (Thorne 2003). The method presented in this protocol provides direction regarding: (1) how to account for each measure's specific characteristics and (2) how to choose the most appropriate savings verification approach.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Earthquake response of head-mounted equipment in advanced nuclear reactors

The seismic response of safety-related equipment mounted on the head of an advanced reactor, including pumps, control rod drive mechanisms, and reactor monitoring devices, will affect the design and layout of many advanced reactors. High earthquake-induced accelerations in such equipment may challenge their seismic qualification and trigger the need for additional support framing on the reactor head. Base isolation is a design solution that can drastically reduce seismic demands on equipment. This article describes a set of earthquake-simulator experiments conducted on a scale-model of a base-isolated reactor vessel including four representations of head-mounted equipment, with frequencies spanning from 4.5 to 27 Hz. Dynamic responses of the head-mounted equipment, including displacements, accelerations, and strains, were measured in the experiments for three support conditions: conventional, and seismically isolated using single concave Friction Pendulum (SFP) bearings and triple Friction Pendulum (TFP) bearings. Seismic isolation was effective at reducing equipment responses (accelerations, displacements, and strains) with respect to those in the conventionally supported vessel across a range of seismic inputs. Companion numerical studies highlight the accuracy to be expected in the calculation of different response quantities for lightly damped equipment. The importance of characterizing damping in head-mounted, safety-related equipment through physical experiments to support design and risk assessment is made clear through the numerical simulations.

Engineering↗

Using Dimmable Lighting for Regulation Capacity and Non-Spinning Reserves in the Ancillary Services Market. A Feasibility Study.

The objective of this Feasibility Study was to identify the potential of dimmable lighting for providing regulation capacity and contingency reserves if massively-deployed throughout the State. We found that one half of the total electric lighting load in the California commercial sector is bottled up in larger buildings that are greater an 50,000 square feet. Retrofitting large California buildings with dimmable lighting to enable fast DR lighting would require an investment of about $1.8 billion and a"fleet" of about 56 million dimming ballasts. By upgrading the existing installed base of lighting and controls (primarily in large commercial facilities) a substantial amount of ancillary services could be provided. Though not widely deployed, today's state-of-the art lighting systems, control systems and communication networks could be used for this application. The same lighting control equipment that is appropriate for fast DR is also appropriate for achieving energy efficiency with lighting on a daily basis. Thus fast DR can leverage the capabilities that are provided by a conventional dimming lighting control system. If dimmable lighting were massively deployed throughout large California buildings (because mandated by law, for example) dimmable lighting could realistically supply 380 MW of non-spinning reserve, 47percent of the total non-spinning reserves needed in 2007.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Design analysis of phosphor-free monolithic white light-emitting-diodes with InGaN/ InGaN multiple quantum wells on ternary InGaN substrates

Phosphor-free monolithic white light emitting diodes (LEDs) based on InGaN/ InGaN multiple quantum wells (MQWs) on ternary InGaN substrates are proposed and analyzed in this study. Simulation studies show that LED devices composed of multi-color-emitting InGaN/ InGaN quantum wells (QWs) employing ternary InGaN substrate with engineered active region exhibit stable white color illumination with large output power (∼ 170 mW) and high external quantum efficiency (EQE) (∼ 50%). The chromaticity coordinate for the investigated monolithic white LED devices are located at (0.30, 0.28) with correlated color temperature (CCT) of ∼ 8200 K at J = 50 A/cm{sup 2}. A reference LED device without any nanostructure engineering exhibits green color emission shows that proper engineered structure is essential to achieve white color illumination. This proof-of-concept study demonstrates that high-efficiency and cost-effective phosphor-free monolithic white LED is feasible by the use of InGaN/ InGaN MQWs on ternary InGaN substrate combined with nanostructure engineering, which would be of great impact for solid state lighting.

36 MATERIALS SCIENCE↗

Characterizing Vulnerabilities Associated with Connected Lighting: Exploring Authorization Protocols

Cities are upgrading their infrastructure and converting traditional indoor and outdoor luminaires to Connected Lighting Systems equipped with sensors in an aggressive effort to reduce energy consumption, increase sustainability, and improve the quality of life. When you take something seemingly benign like a lighting system and connect it to the internet, if improperly secured a potential attack vector for hackers is created. Hackers could then access sensitive information, pivot into other networks, shut down services, or enslave devices to do their bidding. In attempt to close this attack vector and secure these systems, this paper extends previous work that investigated, compared and contrasted authentication vulnerabilities in Connected Lighting Systems that identified the need for additional testing and improved test method documentation. One additional authentication test and four new authorization tests were developed utilizing the Open Web Application Security Project (OWASP) as a test development and documentation guide. The new tests were integrated with the previous work to develop an updated test method with a focus on describing test procedures to make them easy to understand and repeat. In addition, a first Connected Lighting System use case was established to begin developing threat profiles that will aid in the identification of vulnerabilities whose focus areas extend beyond authentication and authorization. This use case describes the generation and flow of CLS data which assists in specifying methods to harden CLSs from outside interference and exploitation that can be implemented immediately on existing CLSs and as new products come to market.

97 MATHEMATICS AND COMPUTING↗

Grid-Interactve Efficient Buildings Technical Report Series: Lighting and Electronics

Through its grid-interactive efficient building (GEB) research, the DOE Building Technologies Office seeks to build on existing energy-efficiency efforts and develop technological capabilities to optimize the interplay between building loads and the electric grid. This report analyzes connected lighting systems and consumer electronics/IT equipment technologies. All lighting technologies are assumed to be lighting-emitting diode (LED) or organic LED (OLED) technologies. These technologies are analyzed in two separate sections and the evaluations are not meant to be comparable to each other or other building technologies.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Chapter 3: Commercial and Industrial Lighting Controls Evaluation Protocol. The Uniform Methods Project: Methods for Determining Energy Efficiency Savings for Specific Measures

This Commercial and Industrial Lighting Controls Evaluation Protocol (the protocol) describes methods to account for energy savings resulting from programmatic installation of lighting control equipment in large populations of commercial, industrial, government, institutional, and other nonresidential facilities. This protocol does not address savings resulting from changes in codes and standards, or from education and training activities. When lighting controls are installed in conjunction with a lighting retrofit project, the lighting control savings must be calculated parametrically with the lighting retrofit project so savings are not double counted.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

CALDER: Cryogenic light detectors for background-free searches

The development of background-free detectors is essential for experiments searching for rare events. Bolometers, that are among the most competitive devices for the study of neutrino-less double beta decay (0νDBD) and Dark Matter interactions, suffer from the absence of techniques that allow to identify the nature of the interacting particles. This limit can be overcome by coupling the bolometer to an independent device for the measurement of the light emitted by interactions, as the combined read-out of the bolometric and light signals allows to identify and reject particles different from those of interest. CUORE, the most advanced bolometric experiment for 0νDBD searches, could disentangle the electrons produced by 0νDBD from the dangerous background due to α particles, by measuring the (tiny) Cherenkov light emitted by electrons and not by α’s. LUCIFER, a project based on ZnSe scintillating bolometers for the study of {sup 82}Se 0νDBD, would be competitive also in the search of Dark Matter interactions if equipped with light detectors that allow to distinguish and reject the background due to electrons and γ’s. These advances require cryogenic detectors characterized by noise lower than 20 eV, large active area, wide temperature range of operation, high radio-purity and ease in fabricating hundreds of channels. The CALDER collaboration aims to develop such detectors by exploiting the superb energy resolution and natural multiplexed read-out provided by Kinetic Inductance Detectors.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗