Electrophysiological experiments on the isolated surviving labyrinth of elasmobranch fish to analyze the responses to linear accelerations
Linear acceleration effects on semicircular canals in elasmobranch fishes
SEARCH · Search NASA
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Linear acceleration effects on semicircular canals in elasmobranch fishes
Although linear accelerators are used in many security, industrial and medical applications, the existing technologies are too large and expensive for several critical applications such as radioactive source replacement, field radiography and mobile cargo scanners. Here, one of the main requirements for these sources is to be highly portable to allow field operation. In response to this problem, RadiaBeam has designed a hand-portable 1 MeV X-ray source, scalable to higher energies, based on Ku-band split electron linac, that can be used for Ir-192 radioisotope replacement. In this paper, we present its multiphysics and engineering design studies, as well as an accelerating structure prototype along with RF measurements.
It is widely accepted that the next lepton collider beyond a Higgs factory would require center-of-mass energy of the order of up to 15 TeV. Since, given reasonable space and cost restrictions, conventional accelerator technology reaches its limits near this energy, high-gradient advanced acceleration concepts are attractive. Advanced and novel accelerators (ANAs) are leading candidates due to their ability to produce acceleration gradients on the order of 1–100 GV/m, leading to compact acceleration facilities. However, intermediate energy facilities (IEF) are required to test the critical technology elements on the way towards multi-TeV-class colliders. Here a science case for a 20–100 GeV center-of-mass energy ANA-based lepton collider that can be a candidate for an intermediate energy facility is presented. The IEF can provide numerous opportunities for high energy physics studies including precision Quantum Chromodynamics and Beyond the Standard Model physics measurements, investigation of charged particle interactions with extreme electromagnetic fields, and exploring muon and proton beam acceleration. Possible applications of this collider include the studies of γγ and electron beam-fixed target/beamdump collider designs. Thus, the goal of the proposed IEF is to both carry out particle physics measurements in the 20-100 GeV ranges as well as to serve as an ANA demonstrator facility.
High-power proton linear accelerators have important applications in both scientific research and industry. However, the operation of such accelerators with megawatt-level beam power is expensive and limits the broad availability of these facilities. In this Letter, we propose a novel energy recovery proton linear accelerator in which the final GeV-level proton beam is reinjected into the linear accelerator from the accelerator exit and is decelerated in the same accelerator down to about 2 MeV, close to the initial beam energy. This substantially reduces the power consumption of the proton linear accelerator and also avoids the need for a high-power beam dump. We demonstrate this concept through self-consistent simulations and show that the beam-beam effect between the forward-accelerating beam and the backward-decelerating beam would not be a limiting factor for the proposed concept. A potential application of this concept to an electron-ion collider based on energy recovery electron and ion accelerators is discussed.
Linear accelerator based X-ray free electron laser (FEL) light sources provide an important tool for scientific discoveries. Most of these light source facilities employ a laser heater to increase the electron beam’s uncorrelated energy spread to suppress microbunching instability through the linear accelerators. In this paper, we first studied the microbunching instability in an X-ray FEL linear accelerator with lower initial peak current (~ 10 A) and moderate final peak currents (1-2 kA). In this regime, the microbunching instability can be substantially mitigated with modest initial uncorrelated energy spread. Here, we then suggested a less expensive method to mitigate the microbunching instability using a section of low beta FODO lattice instead of the laser heater. With the use of the high brightness electron beam from a photoinjector, the intrabeam scattering effect inside the beam through the FODO lattice can generate sufficient uncorrelated energy spread to mitigate the microbunching instability. At last, we demonstrated the feasibility of this method with self-consistent solution of the Fokker–Planck equation through the X-ray FEL linear accelerator.
Modern electron linear accelerators are often designed to produce smooth bunch distributions characterized by their macroscopic ensemble-average moments. However, an increasing number of accelerator applications call for finer control over the beam distribution, such as by requiring specific shapes for its projection along one coordinate. Ultimately, the control of the beam distribution at the single-particle level could enable new opportunities in accelerator science. This review discusses the recent progress toward controlling electron beam distributions on the “mesoscopic” scale with an emphasis on shaping the beam or introducing complex correlations required for some applications. This review emphasizes experimental and theoretical developments of electron-bunch shaping methods based on bounded external electromagnetic fields or via interactions with the self-generated velocity and radiation fields.
The Linear Accelerator, a sliding chair which is pulled along a stationary platform in a horizontal axis is described. The driving force is a motor controlled by a velocity loop amplifier, and the mechanical link to the chair is a steel cable. The chair is moved in forward and reverse directions as indicated by the direction of motor rotation. The system operation is described with emphasis on the electronic control and monitoring functions. Line-by-line schematics and wire lists are included.
Linear accelerators (linacs), producing electron or X-ray radiation in the MeV range, are critical tools for industrial irradiation, medical device sterilization, food pasteurization, non-destructive testing, security, medical, and many other applications. Many of these applications require compact and flexible radiation sources. In this paper, we present new technologies for small-scale electron linear accelerators and examples of their practical implementations. Furthermore, these developments include low energy accelerators with self-shielding options and form factors, ranging from cabinet-size to hand-portable generators; medium-energy accelerators for novel radiotherapy and security applications; and high-energy 10 MeV linacs capable of reaching 20–35 kW beam power for emerging industrial and phytosanitary applications
Effect of changing resultant linear acceleration relative to human subject on nystagmus generated by angular acceleration
In the present study, the sensitivity to sinusoidal linear accelerations in the plane of the utricular macula was tested in afferents. The head orientation relative to the translation axis was varied in order to determine the head position that elicited the maximal and minimal responses for each afferent. The response gain and phase values obtained to 0.5-Hz and 2-Hz linear acceleration stimuli were then plotted as a function of head orientation and a modified cosine function was fit to the data. From the best-fit cosine function, the predicted head orientations that would produce the maximal and minimal response gains were estimated. The estimated maximum response gains to linear acceleration in the utricular plane for the afferents varied between 75 and 1420 spikes s-1 g-1. The mean maximal gains for all afferents to 0.5-Hz and 2-Hz sinusoidal linear acceleration stimuli were 282 and 367 spikes s-1 g-1, respectively. The minimal response gains were essentially zero for most units. The response phases always led linear acceleration and remained constant for each afferent, regardless of head orientation. These response characteristics indicate that otolith afferents are cosine tuned and behave as one-dimensional linear accelerometers. The directions of maximal sensitivity to linear acceleration for the afferents varied throughout the plane of the utricle; however, most vectors were directed out of the opposite ear near the interaural axis. The response dynamics of the afferents were tested using stimulus frequencies ranging between 0.25 Hz and 10 Hz (0.1 g peak acceleration). Across stimulus frequencies, most afferents had increasing gains and constant phase values. These dynamic properties for individual afferents were fit with a simple transfer function that included three parameters: a mechanical time constant, a gain constant, and a fractional order distributed adaptation operator.
Plasma-based accelerators (PBAs) driven by either intense lasers (laser wakefield accelerators, LWFAs) or particle beams (plasma wakefield accelerators, PWFAs), can accelerate charged particles at extremely high gradients compared to conventional radio-frequency (RF) accelerators. In the past two decades, great strides have been made in this field, making PBA a candidate for next-generation light sources and colliders. However, these challenging applications necessarily require beams with good stability, high quality, controllable polarization and excellent reproducibility. To date, such beams are generated only by conventional RF accelerators. As such, it is important to demonstrate the injection and acceleration of beams first produced using a conventional RF accelerator, by a PBA. In some recent studies on LWFA staging and external injection-acceleration in PWFA only a very small fraction (from below 0.1% to few percent) of the injected charge (the coupling efficiency) was accelerated. For future colliders where beam energy will need to be boosted using multiple stages, the coupling efficiency per stage must approach 100%. Here we report the first demonstration of external injection from a photocathode-RF-gun-based conventional linear accelerator (LINAC) into a LWFA and subsequent acceleration without any significant loss of charge or degradation of quality, which is achieved by properly shaping and matching the beam into the plasma structure. Furthermore, this is an important step towards realizing a high-throughput, multi-stage, high-energy, hybrid conventional-plasma accelerator.
Linear acceleration transients were used to elicit vestibular compound action potentials in non-invasively prepared, unanesthetized animals for the first time (chicks, Gallus domesticus, n = 33). Responses were composed of a series of up to 8 dominant peaks occurring within 8 msec of the stimulus. Response amplitudes for 1.0 g stimulus ranged from 1 to 10 microV. A late, slow, triphasic, anesthesia-labile component was identified as a dominant response feature in unanesthetized animals. Amplitudes increased and latencies decreased as stimulus intensity was increased (MANOVA P less than 0.05). Linear regression slope ranges were: amplitudes = 1.0-5.0 microV/g; latencies = -300 to -1100 microseconds/g. Thresholds for single polarity stimuli (0.035 +/- 0.022 g, n = 11) were significantly lower than those of alternating polarity (0.074 +/- 0.028 g, n = 18, P less than 0.001). Bilateral labyrinthectomy eliminated responses whereas bilateral extirpation of cochleae did not significantly change response thresholds. Intense acoustic masking (100/104 dB SL) produced no effect in 2 animals, but did produce small to moderate effects on response amplitudes in 7 others. Changes were attributed to effects on vestibular end organs. Results of unilateral labyrinth blockade (tetrodotoxin) suggest that P1 and N1 preferentially reflect ipsilateral eighth nerve compound action potentials whereas components beyond approximately 2 msec reflect activity from vestibular neurons that depend on both labyrinths. The results demonstrate that short latency vestibular compound action potentials can be measured in unanesthetized, non-invasively prepared animals.
Linear acceleration influence on vestibular nystagmus and postulation of simple model based on otolith contribution
Thresholds for detecting linear motion (self-motion) increased following exposure of human observers to sustained linear oscillation (fatiguing stimulus) at 0.26 Hz and approximately 0.5 G peak-to-peak for durations up to 30 min. Recovery to preexposure levels took place over a period of 10 to 15 min following the sustained oscillation termination. Differences in threshold shift magnitudes following sustained oscillation in various orientations support the interpretation that the observed threshold shifts resulted from fatigue of the utricular otolith receptors. Threshold shifts were not obtained following exposure of the human observers to sustained, unidirectional linear acceleration (2G) for durations up to 10 min with a centrifuge. The results of this study suggest a previously unobserved response property of the otolith organs, namely, that these organs can be fatigued in a manner analogous to other receptor systems.
Superconducting electron linear accelerators open up new opportunities for advanced materials processing. High energy electrons penetrate deeper within materials, increase the processing depth and rate and enables production of far-from-equilibrium materials and selective processing within a material surface and subsurface. With support from the Office of Naval Research, NASA, and DoE, Mainstream Engineering commissioned a superconducting linear electron accelerator to investigate advanced materials processing and additive manufacturing. The goal of Mainstream's Electron Beam Enabled Advanced Manufacturing (EBEAM) center is to develop unique, far-from-equilibrium materials and alleviate significant technological deficiencies. We will present results of irradiating various metals and their unique material properties. Monte Carlo simulations electron beam and sample interaction were used to optimize the processing parameters and study far-from-equilibrium processing conditions. Applications include stainless steel additive manufacturing for small modular nuclear reactors and dissimilar metal bonding of corrosion-resistant cladding for next-generation molten salt reactors.
While considerable attention has been given to visual-vestibular interaction (VVI) during angular motion of the head as might occur during an aircraft spin, much less attention has been given to VVI during linear motion of the head. Such interaction might occur, for example, while viewing a stationary or moving display during vertical take-off and landing operations Research into linear VVI, particularly during prolonged periods of linear acceleration, has been hampered by the unavailability of a programmable translator capable of large excursions We collaborated with Otis Elevator Co. and used their research tower and elevator, whose motion could be digitally programmed, to vertically translate human subjects over a distance of 92.3 meters with a peak linear acceleration of 2 meters/sec(exp 2) During pulsatile or sinusoidal translation, the subjects viewed moving stripes (optokinetic stimulus) or a fixed point source (light emitting diode, led, display), respectively and it was generally found that. The direction of linear acceleration relative to the cardinal head axes and the direction of the slow component of optokinetic nystagmus (OKN) determined the extent of VVI during concomitant stripe motion and linear acceleration. Acceleration along the z head axis (A(sub z)) produced the largest VVI, particularly when the slow component of OKN was in the same direction as eye movements produced by the linear acceleration and Eye movements produced by linear acceleration are suppressed by viewing a fixed target at frequencies below 10 Hz But, above this frequency the suppression produced by VVI is removed. Finally, as demonstrated in non-human primates, vergence of the eyes appears to modulate the vertical eye movement response to linear acceleration in humans.
We present a topology for linear accelerators (linacs) in which the power is distributed to the cavities through a waveguide with periodic apertures that guarantees the correct phases and amplitudes along the structure length. Unlike conventional traveling and standing-wave linacs, the presented topology allows the cavity shapes to be designed without the constraints applied to the coupling between cells to transfer power from one cell to the next. Therefore, the topology permits more degrees of freedom for the optimization of individual cavity shapes in comparison with conventional linacs. The cavity shapes can be optimized for power consumption and efficiency, and/or the manipulation of the surface fields for high gradient operation. This topology also provides a possibility for low-temperature manufacturing techniques that prevent the annealing of the material during typical brazing processes; hence, the material could retain its original properties such as hardness. We present a design and an experimental demonstration of this linac.
Photoneutron production is possible using an electron linear accelerator and a target capable of generating photonuclear reactions. A short pulse neutron source can be useful for neutron imaging dynamic experiments. This study is aimed at the feasibility of photoneutron production using a 20 MeV electron linear accelerator and tungsten and depleted uranium targets of various thicknesses. MCNP6 (Monte Carlo N-Particle) code will be used to develop a computational model to estimate total neutron yield, and this will be verified at the Idaho State University’s Accelerator Center. After verification of the neutron yield and energy spectra, an additional MCNP6 model will be developed to analyze the neutron imaging processes. This study will potentially prove it is possible to conduct multi-mode imaging experiments on the anticipated Scorpius electron linear accelerator at the Nevada National Security Sites.