SEARCH · Search NASA
Results for “LIQUEFIED GASES”
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Evaluation of Liquefied Hydrocarbon Gases as Turbojet Fuels
Explore the source record for details and available documents.
Two Heat-Transfer Improvements for Gas Liquefiers
Two improvements in heat-transfer design have been investigated with a view toward increasing the efficiency of refrigerators used to liquefy gases. The improvements could contribute to the development of relatively inexpensive, portable oxygen liquefiers for medical use. A description of the heat-transfer problem in a pulse-tube refrigerator is prerequisite to a meaningful description of the first improvement. In a pulse-tube refrigerator in particular, one of in-line configuration heat must be rejected from two locations: an aftercooler (where most of the heat is rejected) and a warm heat exchanger (where a small fraction of the total input power must be rejected as heat). Rejection of heat from the warm heat exchanger can be problematic because this heat exchanger is usually inside a vacuum vessel. When an acoustic-inertance tube is used to provide a phase shift needed in the pulse-tube cooling cycle, another problem arises: Inasmuch as the acoustic power in the acoustic-inertance tube is dissipated over the entire length of the tube, the gas in the tube must be warmer than the warm heat exchanger in order to reject heat at the warm heat exchanger. This is disadvantageous because the increase in viscosity with temperature causes an undesired increase in dissipation of acoustic energy and an undesired decrease in the achievable phase shift. Consequently, the overall performance of the pulse-tube refrigerator decreases with increasing temperature in the acoustic-inertance tube. In the first improvement, the acoustic-inertance tube is made to serve as the warm heat exchanger and to operate in an approximately isothermal condition at a lower temperature, thereby increasing the achievable phase shift and the overall performance of the refrigerator. This is accomplished by placing the acoustic-inertance tube inside another tube and pumping a cooling fluid (e.g., water) in the annular space between the tubes. Another benefit of this improvement is added flexibility of design to locate the warm heat-rejection components outside the vacuum vessel. The second improvement is the development of a compact radial-flow condenser characterized by a very high heat transfer coefficient and a small pressure drop.
Ultra Efficient CHHP Using a High Temperature Fuel Cell to Provide On-Site Process Reducing Gas, Clean Power, and Heat
FuelCell Energy and ACuPowder investigated and demonstrated the use of waste anode exhaust gas from a high temperature fuel cell for replacing the reducing gas in a metal processing furnace. Currently companies purchase high pressure or liquefied gases for the reducing gas which requires substantial energy in production, compression/liquefaction, and transportation, all of which is eliminated by on-site use of anode exhaust gas as reducing gas. We performed research on the impact of the gas composition on product quality and then demonstrated at FuelCell Energy’s manufacturing facility in Torrington, Connecticut. This demonstration project continues to operate even though the research program is completed as it provides substantial benefits to the manufacturing facility by supplying power, heat, and hydrogen.
Rocket Engine Test System for Development of Novel Propulsion Technologies
A 150 lb f thrust class, modular, bi-propellant, rocket engine/gas-generator and supporting test infrastructure has been developed in a cooperative effort between Sandia National Laboratories and the New Mexico Institute of Mining and Technology’s (NMIMT’s) Energetic Materials Research and Testing Center (EMRTC). This modular test engine design consists of a head end fuel-oxidizer injector, a spark ignition gaseous H 2 /O 2 torch igniter, combustion chamber and nozzle module. This robust design allows for rapid configuration changes as well as economical repair should hardware become damaged in testing. The engine interfaces with a permanently installed pressurizing system capable of delivering liquid nitrous oxide and a variety of liquid fuels for both rocket engine development and propellant performance evaluation. The regulated high pressure systems allow for delivery of liquefied gases above their saturation pressure as well as allowing for high pressure rocket engine/gas-generator operation. The facility test cell houses a 1 ton thrust capacity test stand leaving room for larger scale engine development.
STABILITY OF FILM BOILING TWO-PHASE FLOW IN CRYOGENIC SYSTEMS
The stability of film boiling two phase flow is investigated referring in particular to saturated cryogenic liquids. This type of fluid motion is unstable, such that a range of wave numbers will always be present in which disturbances are amplified. Further the mode of operation of the energy supply system may favour temperature fluctuations of large amplitude if the circuit does not provide feed-back compensation. The theoretically predicted stabilization due to capillarity is reduced considerably in liquefied gases with low surface tension, such as hydrogen. This effect causes the transition to turbulent flow to occur at low Reynolds numbers, and increases the heat transport in the turbulent regime. A comparison with experimental data, (horizontal cylinder), shows that the "critical" film Reynolds number ūδ/𝜈, at which instabilities become effective, is lowered from approximately 200, (O2), to about 30, (H2). Similar results have been found with other configurations. Therefore application of laminar film boiling solutions is restricted to small objects, entrance regions, or stagnation points. Turbulent correlations given so far are valid only for a certain group of substances with similar behavior.
Insulating structure Patent
Insulating system for receptacles of liquefied gases using wire cloth for forming frost layer
Use of thin plastic films at cryogenic temperatures
Commercially available plastic film materials that remain flexible at cryogenic temperatures and resist failures caused by folds and wrinkles created during expulsion were investigated for use in expulsion bladders for liquefied gases. Compatible adhesive systems, fabrication techniques, and results of impact and dynamic loading tests are summarized.
High pressure liquid gas pump
Design and development of two types of pumps for handling liquefied gases are discussed. One pump uses mechanical valve shift and other uses pneumatic valve shift. Illustrations of pumps are provided and detailed description of operation is included.
A Solid Film Lubricant Composition for Use at High Sliding Velocities in Liquid Nitrogen
Solid-lubricant-containing compositions can be of value as films and solid bodies for bearing and seal surfaces in low-temperature liquefied gases. An experimental composition including polytetrafluoroethylene (PTFE), an epoxy resin, and lithium-alumina-silicate was studied in friction, wear, and endurance experiments in liquid nitrogen (−320 F). This composition was formulated to approximate the thermal expansion of metals used in cryogenic systems. Hemisphere (3/6-in. radius) rider specimens were used and in most experiments the load was 1000 g. Films (0.005-in. thick) on disk specimens gave good endurance life, low rider wear, and desirable friction (f = 0.02 to 0.07). They functioned at a higher sliding velocity (no failure at 16, 000 ft/min) with copper rider specimens than with stainless steel riders (failure at 9000 ft/min). Solid rider material of the experimental composition had good friction and wear properties at sliding velocities above 4000 ft/min. It is important to use the experimental composition with mating materials having good thermal conductivity.
Large Scale Cryogenic Storage with Active Refrigeration
Storage and transfer of cryogenic liquefied gases on volume scales from under 10 liters for lab use, up to hundreds of millions of liters for industrial applications is of paramount importance across a vast range of industries. Traditionally, these commodities have been stored at or near the normal boiling point due to relative ease of operation and safety-related considerations; however, this also means that some percentage will always be lost due to environmental heat leaking into the vessel and causing boil-off. These losses become more concerning as scales increase, and are of particular importance for high-cost commodities such helium and hydrogen. Additionally, the normal boiling point marks the highest liquid density achievable; which becomes a strong driver of end-use system designs such as space launch vehicles. Recent development and testing of an Integrated Refrigeration and Storage (IRAS) system for liquid hydrogen has proven that next generation cryogenic storage operations such as zero boil-off and densification are feasible on a large scale. This IRAS system married an 850 Watt at 20 Kelvin reverse-Brayton cycle commercial cryogenic refrigerator with a 125,000 liter LH2 storage tank via and internal tubular heat exchanger. This allowed heat to be removed directly from the hydrogen, and by extension, provided a means to control the bulk thermodynamic state. Zero boil-off, in-situ liquefaction, and densification down to the triple point was performed during testing, and data such as fluid temperature profiles and tank pressure were gathered. Details regarding the design, setup, and testing of the IRAS system are discussed herein, and the data used to anchor various physics models created to predict the behavior of the system during transient and steady state operation. It is hoped that these efforts will provide a useful basis for the design and implementation of future large scale IRAS systems across numerous industries.
The XENON100 Dark Matter Experiment
The XENON100 experiment is searching for WIMPs, which are particles that may consist dark matter. It is located in the underground laboratory of Gran Sasso (LNGS) in Italy at a depth of {approx}3600 m.w.e.. The experiment description, its performance and the expected background based on Monte Carlo simulations and material screening along with the projected sensitivities of the experiment are presented. In addition, a brief description of the upgrade XENON100 detector is given.
THE LIQUID NITROGEN SYSTEM FOR CHAMBER A; A CHANGE FROM ORIGINAL FORCED FLOW DESIGN TO A NATURAL FLOW (THERMO SIPHON) SYSTEM
NASA at the Johnson Space Center (JSC) in Houston is presently working toward modifying the original forced flow liquid nitrogen cooling system for the thermal shield in the space simulation chamber-A in Building 32 to work as a natural flow (thermo siphon) system. Chamber A is 19.8 m (65 ft) in diameter and 35.66 m (117 ft) high. The LN{sub 2} shroud environment within the chamber is approximately 17.4 m (57 ft) in diameter and 28 m (92 ft) high. The new thermo siphon system will improve the reliability, stability of the system. Also it will reduce the operating temperature and the liquid nitrogen use to operate the system. This paper will present the requirements for the various operating modes. System level thermodynamic comparisons of the existing system to the various options studied and the final option selected will be outlined. A thermal and hydraulic analysis to validate the selected option for the conversion of the current forced flow to natural flow design will be discussed. The proposed modifications to existing system to convert to natural circulation (thermo siphon) system and the design features to help improve the operations, and maintenance of the system will be presented.
Helium Refrigerator Liquid Nitrogen Pre-Cooler Component Parameter Sensitivity Analysis
For helium refrigerators using liquid nitrogen (LN) pre-cooling it is not uncommon for the ambient helium refrigeration return stream(s) exiting the cold box to be significantly colder and for the cycle to use more nitrogen than estimated by the process studies. Often there is an emphasis on the length of 300 to 80-K helium-nitrogen heat exchangers to ensure the exiting nitrogen is as close to ambient as possible. However, it is really the size and flow distribution of the 300 to 80-K helium-helium heat exchangers which are the dominate influence of the nitrogen consumption. As such, an analysis was done to identify and quantify the sensitivity the key parameters in the refrigerator LN pre-cooler section affecting the LN consumption.
Results from phase I of the GERDA experiment
The GERmanium Detector Array Gerda at the Laboratori Nazionali del Gran Sasso of the INFN in Italy is an experiment dedicated to the search for the neutrinoless double beta (0νββ) decay in {sup 76}Ge. The experiment employs high purity germanium detectors enriched in {sup 76}Ge inside a 64 m{sup 3} cryostat filled with liquid argon. Gerda was planned in two phases of data taking with the goal to reach a half-life sensitivity in the order of 10{sup 26} yr. Phase I of Gerda was running from November 2011 until May 2013. With about 18 kg total detector mass, data with an exposure of 21.6 kg·yr was collected and a background index of 0.01 cts/(keV·kg·yr) was achieved in the region of interest. No signal was found for the 0νββ decay and a new limit of T{sub 1/2} > 2.1 · 10{sup 25} yr (90% C.L.) was obtained, strongly disfavoring the previous claim of observation. Furthermore, the 2νββ decay half-life of {sup 76}Ge was measured with unprecedented precision. Other results include new half-life limits of the order of 10{sup 23} yr for Majoron emitting double beta decay modes with spectral indices n = 1, 2, 3, 7 and new limits in the order of 10{sup 23} yr for 2νββ decays to the first 3 excited states of {sup 76}Se. In Phase II, currently in preparation, the detector mass will be doubled while reducing the background index by a factor of 10.
2D/3D cryo x-ray fluorescence imaging at the bionanoprobe at the advanced photon source
Trace elements, particularly metals, play very important roles in biological systems. Synchrotron-based hard X-ray fluorescence microscopy offers the most suitable capabilities to quantitatively study trace metals in thick biological samples, such as whole cells and tissues. In this manuscript, we have demonstrated X-ray fluorescence imaging of frozen-hydrated whole cells using the recent developed Bionanoprobe (BNP). The BNP provides spatial resolution down to 30 nm and cryogenic capabilities. Frozen-hydrated biological cells have been directly examined on a sub-cellular level at liquid nitrogen temperatures with minimal sample preparation.
Magnetic x-ray microscopy at low temperatures – Visualization of flux distributions in superconductors
X-ray Magnetic Circular Dichroism (XMCD) microscopy at liquid nitrogen temperature has been performed on bilayers of high-T{sub c} superconducting YBCO (YBa{sub 2}Cu{sub 3}O{sub 7-δ}) and soft-magnetic Co{sub 40}Fe{sub 40}B{sub 20}. This should allow us to map the magnetic flux density distribution in the current-carrying state of the superconductor with high spatial resolution. For that purpose the UHV scanning X-ray microscope MAXYMUS has been upgraded by a MMR Micro Miniature Joule-Thompson cryostat capable of temperatures between 75 K and 580 K. Resulting XMCD images of the magnetic flux density in the superconductor with a field of view ranging from millimeters to micrometers are presented. The microscope’s unique combination of total electron yield (TEY) measurements together with low temperatures offers novel possibilities concerning the current transport in superconductors on small length scales.
Deformation microstructure and positive temperature dependence of flow stress in Ni{sub 3}Ge
Single crystalline specimens of Ni{sub 3}Ge were compressed along [0 0 1] at different temperatures. Temperature dependence of the critical resolved shear stress (τ{sub 0}(T)) has been obtained. Detailed measurements at cryogen temperatures (4.2-77 K temperature interval) showed that the increase of the yield stress with temperature starts at liquid helium temperature. The values of the apparent activation volume (V*) have been obtained as a result of stress relaxation tests repeated along the stress-strain curve at different stress levels at seven temperatures (77, 293, 373, 473, 573, 673, 773 K). Transmission electron microscopy (TEM) methods were used to analyze the evolution of dislocation structure with temperature and strain. The measurements of the straight dislocations fraction determined as δ = ρ{sub sd} / ρ, (ρ{sub sd} is the straight dislocation density, ρ is a total dislocation density) have been performed. The experimental data obtained in different tests in Ni{sub 3}Ge confirm two-stage nature of the positive temperature dependence of the flow stress of alloys with the L1{sub 2} structure. The model of thermal strengthening considering two different types of mechanisms, first acting at low temperatures and second at high has been proposed. Using this model the temperature dependence of the critical resolved shear stress has been approximated and the activation parameters of thermal strengthening of Ni{sub 3}Ge have been obtained.