Search NASA⌕ Search

SEARCH · Search NASA

Results for “LIQUID SCINTILLATION DETECTORS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Event Reconstruction for Water-based Liquid Scintillator Detectors

Water Cherenkov and liquid scintillator detectors represent two complementary approaches in neutrino physics. Water Cherenkov detectors provide particle track direction and particle identification (PID) through Cherenkov ring topology, while liquid scintillator detectors offer higher light yield and lower energy thresholds. Water-based liquid scintillator (WbLS) is designed to combine the advantages of both technologies. However, the simultaneous detection of Cherenkov and scintillation light by photosensors introduces significant challenges for event reconstruction. This poster presents event reconstruction studies for WbLS detectors. A likelihood-based reconstruction framework, fiTQun, has been successfully used in Super-Kamiokande to reconstruct water Cherenkov events in cylindrical detectors. We extend and improve this framework to demonstrate event reconstruction in WbLS detectors, enabling the concurrent reconstruction of particle energy, PID, vertex, and direction. The results demonstrate competitive performance in energy resolution, PID separation, and vertex and direction reconstruction, highlighting the strong potential of WbLS for next-generation neutrino experiments.

Xie, Zhenxiong [Minnesota U.] (ORCID:0009000301442↗

A liquid scintillation detector for radioassay of gadolinium-loaded liquid scintillator for the LZ Outer Detector

© 2019 Elsevier B.V. We report on the design and performance of the LUX-ZEPLIN (LZ) “Screener”, a small liquid scintillator detector consisting of ≈23 kg of LAB-based gadolinium-loaded liquid scintillator (GdLS) to be used in the LZ Outer Detector. The Outer Detector will be filled with 17.3 tonnes of GdLS and will surround the central liquid xenon time projection chamber of LZ. Its primary function will be to tag neutron events in the liquid xenon which could mimic a WIMP dark matter signal. To meet the deadtime requirements for the Outer Detector, the radioimpurity levels in the GdLS must be kept below ≲0.07 mBq/kg. This background level corresponds to a rate of ≈50Hz above an energy threshold of 100 keV. The Screener was operated in the ultra-low-background environment of the former LUX water shield in the Davis Laboratory at the Sanford Underground Research Facility for radioassay of the GdLS. Careful selection of detector materials and use of ultra-low-background PMTs allows the measurement of a variety of radioimpurities. The 14C/12C ratio in the scintillator is measured to be (2.83±0.06(stat.)±0.01(sys.))×10 -17 . Use of pulse shape discrimination allows the concentration of isotopes throughout the 238U, 235U, and 232Th chains to be measured by fitting the collected spectra from α and β events. We find that equilibrium is broken in the 238U and 232Th chains and that a significant portion of the contamination in the GdLS results from decays in the 227Ac subchain of the 235U series. Predictions for the singles rate in the Outer Detector are presented. The rate from radioimpurities above 100 keV in the GdLS is estimated to be 97.9±6.4Hz, with 65.5±1.9Hz resulting from α-decays.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Organic liquid scintillation detector shape and volume impact on radiation portal monitors

We have developed and tested a radiation portal monitor using organic liquid scintillation detectors. In order to optimize our system designs, neutron measurements were carried out with three organic liquid scintillation detectors of different shapes and sizes, along with a 3 He radiation portal monitor (RPM) as a reference. The three liquids tested were a 7.62 cm diameter by 7.62 cm length cylindrical active volume organic liquid scintillation detector, a 12.7 cm diameter by 12.7 cm length cylindrical active volume organic liquid scintillation detector, and a 25 cm by 25 cm by 10 cm “paddle” shaped organic liquid scintillation detector. Background and Cf-252 neutron measurements were recorded to allow for a comparison of neutron intrinsic efficiencies as well as receiver operating characteristics (ROC) curves between detectors. The 12.7 cm diameter cylindrical active volume organic liquid scintillation detector exhibited the highest intrinsic neutron efficiency (54%) of all three liquid scintillators. An ROC curve analysis for a heavily moderated Cf-252 measurement showed that using the 12.7 cm diameter by 12.7 cm length cylindrical active volume Eljen EJ309 organic liquid scintillation detector would result in the fewest needed detector units in order to achieve a near 100% positive neutron alarm rate while maintaining a better than 1 in 10,000 false alarm rate on natural neutron background. As a result, a small number of organic liquid scintillation detectors could therefore be a valid alternative to 3 He in some RPM applications.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Performance of a ton-scale water-based liquid scintillator detector

This study reports the performance and light yield of 1% concentration water-based liquid scintillator (WbLS) deployed in a 1000-liter detector. A light yield of 99± 15 photons per MeV is determined by comparing data with simulation. This result aligns with our previous light yield determination using smaller detectors, thus establishing a solid foundation for the ongoing development and deployment of WbLS in larger-scale detectors. In conclusion, the feasibility of in situ preparation and the stability of light yield in WbLS are demonstrated, reinforcing its suitability for long-term experimental endeavors.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

A spectrometric approach to measuring the Rayleigh scattering length for liquid scintillator detectors

Good optical transparency is a fundamental requirement of liquid scintillator (LS) detectors. Characterizing the transparency of a liquid scintillator to its own emitted light is a key parameter to determine the overall sensitivity of a large-volume detector. The attenuation of light in an optical-pure LS is dominated by Rayleigh scattering, which poses an intrinsic limit to the transparency of LS. This work presents a spectrometric approach of measuring the wavelength-dependent scattering length of liquids by applying the Einstein-Smoluchowski theory to a measurement of scattered light intensity. The scattering lengths of linear alkyl benzene (LAB) and EJ309-base (Di-isopropylnaphthalene, DIN) were measured and are reported in the wavelength range of 410–520 nm. The spectral peak of scintillation light emitted by a nominal LS is around 430 nm at which the scattering lengths for LAB and EJ-309-base were determined to be 27.9 ± 2.3 m and 6.1 ± 0.6 m.

47 OTHER INSTRUMENTATION↗

Results of low energy background measurements with the Liquid Scintillation Detector (LSD) of the Mont Blanc Laboratory

The 90 tons liquid scintillation detector (LSD) is fully running since October 1984, at a depth of 5,200 hg/sq cm of standard rock underground. The main goal is to search for neutrino bursts from collapsing stars. The experiment is very sensitive to detect low energy particles and has a very good signature to gamma-rays from (n,p) reaction which follows the upsilon e + p yields n + e sup + neutrino capture. The analysis of data is presented and the preliminary results on low energy measurements are discussed.

Aglietta, M.↗

The research program of the Liquid Scintillation Detector (LSD) in the Mont Blanc Laboratory

A massive (90 tons) liquid scintillation detector (LSD) has been running since October 1984 in the Mont Blanc Laboratory at a depth of 5,200 hg/sq cm of standard rock. The research program of the experiment covers a variety of topics in particle physics and astrophysics. The performance of the detector, the main fields of research are presented and the preliminary results are discussed.

Dadykin, V. L.↗

Performance of a segmented 6 Li-loaded liquid scintillator detector for the PROSPECT experiment

This study describes the design and performance of a 50 liter, two-segment 6 Li-loaded liquid scintillator detector that was designed and operated as prototype for the PROSPECT (Precision Reactor Oscillation and Spectrum) Experiment. The two-segment detector was constructed according to the design specifications of the experiment. It features low-mass optical separators, an integrated source and optical calibration system, and materials that are compatible with the 6 Li-doped scintillator developed by PROSPECT. We demonstrate a high light collection of 850±20 PE/MeV, an energy resolution of σ = 4.0±0.2% at 1 MeV, and efficient pulse-shape discrimination of low dE/dx (electronic recoil) and high dE/dx (nuclear recoil) energy depositions. An effective scintillation attenuation length of 85±3 cm is measured in each segment. The 0.1% by mass concentration of 6 Li in the scintillator results in a measured neutron capture time of τ = 42.8±0.2 μs. The long-term stability of the scintillator is also discussed. Finally, the detector response meets the criteria necessary for achieving the PROSPECT physics goals and demonstrates features that may find application in fast neutron detection.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Atmospheric charged $$K/\pi $$ ratio and measurement of muon annual modulation with a liquid scintillation detector at Soudan

We report a measurement of muon annual modulation in a 12-l liquid scintillation detector with a live-time of more than 4 years at the Soudan Underground Laboratory. Muon minimum ionization in the detector is identified by its observed pulse shape and large energy deposition. The measured muon rate in the detector is $$28.69\pm 2.09$$ 28.69 ± 2.09 muons per day with a modulation amplitude of ( $$2.64\pm 0.07$$ 2.64 ± 0.07 )% and a phase at Jul $$22 \pm 36.2$$ 22 ± 36.2 days. This annual modulation is correlated with the variation of the effective atmospheric temperature in the stratosphere. The correlation coefficient, $$\alpha _{T}$$ α T , is determined to be $$0.898 \pm 0.025$$ 0.898 ± 0.025 . This can be interpreted as a measurement of the atmospheric charged kaon to pion ( $$K/\pi $$ K / π ) ratio of $$0.094^{+0.044}_{-0.061}$$ 0 . 094 - 0.061 + 0.044 for $$E_{p} > 7$$ E p > 7 TeV, consistent with the measurement from the MINOS far detector. To further constrain the value of $$K/\pi $$ K / π ratio, a Geant4 simulation of the primary cosmic-ray protons with energy up to 100 TeV is implemented to study the correlation of $$K/\pi $$ K / π ratio and the muon annual modulation for muon energy greater than 0.5 TeV. We find out that a charged $$K/\pi $$ K / π ratio of 0.1598, greater than the upper bound (0.138) from this work at the production point 30 km above the Earth surface in the stratosphere cannot induce muon annual modulation at the depth of Soudan.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Design, construction, and operation of a 1-ton Water-based Liquid scintillator detector at Brookhaven National Laboratory

Water-based liquid scintillators (WbLS) are a new class of detector materials that provide efficient and tunable detection of both Cherenkov and scintillation light. A massive WbLS neutrino detector with suitable photosensor coverage for low intensity light detection could therefore reconstruct the momentum of an energetic charged particle and also have enhanced low-energy sensitivity. These materials are also better suited for metal doping broadening the potential scientific utility. Here, we recently constructed and commissioned a 1-ton WbLS detector with good photosensor coverage and a capable data acquisition and calibration system. We intend to use this flexible detector system as a testbed for WbLS R&D. In this paper we give an overview of the 1-ton system and provide some early results.

47 OTHER INSTRUMENTATION↗

MeV-scale performance of water-based and pure liquid scintillator detectors

This paper presents studies of the performance of water-based liquid scintillators (WbLS) in both 1-kt and 50-kt detectors. In this work, performance is evaluated in comparison to both pure water Cherenkov detectors and a nominal model for pure scintillator detectors. Performance metrics include energy, vertex, and angular resolution, along with a metric for the ability to separate the Cherenkov from the scintillation signal as being representative of various particle identification capabilities that depend on the Cherenkov/scintillation ratio. We also modify the time profile of scintillation light to study the same performance metrics as a function of rise and decay time. We go on to interpret these results in terms of their impact on certain physics goals, such as solar neutrinos and the search for Majorana neutrinos. This work supports and validates previous results, and the assumptions made therein, and serves as a significant stepping stone to complete detector design studies by using a more detailed detector model and full reconstruction, with a primarily data-driven optical model, and fewer model assumptions. With this model, a high-coverage 50-kt detector achieves better than 10 (1)% precision on the flux of neutrinos from the Carbon-Nitrogen-Oxygen cycle with a water-based liquid scintillator (pure LS) target in five years of data taking. A 1-kt LS detector, with a conservative 50% fiducial volume of 0.5 kt, can achieve better than 5% detection. A liquid scintillator detector has sensitivity into the normal hierarchy region for Majorana neutrinos with half-life sensitivity of $T^{0νββ}_{1/2}$ > 1.4 × 10 28 years at 90% C.L. for 10 years of data taking with a Te-loaded target.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Low energy neutrino detection with a compact water-based liquid scintillator detector

In this study, the conceptual design and physics simulations of a near-field Water-based Liquid Scintillator (WbLS) detector placed 100 m from the Akkuyu Nuclear Power Plant (ANPP), currently under construction and aiming at being Turkey’s first nuclear power plant, is presented. The ANPP is an excellent opportunity for neutrino studies and the development of an R &D program for neutrino detectors in Turkey. The Reactor Neutrino Experiments of Turkey (RNET) program includes a compact detector with a 2.5-ton volume of WbLS and a ~ 30% photo-coverage, and the program is planned to be expanded with a medium-size 30-ton detector that will be an international testbed for WbLS and new detector technologies through low energy neutrino studies. In the following, the focus will be on the smaller ~2.5 ton detector, instrumented with 8-in. high quantum efficiency PMTs and two layers of cosmic veto paddles, covering all sides of the detector, to track and veto cosmic particles. Inverse Beta Decay (IBD) events from electron anti-neutrinos generated in the reactor core are simulated using the RAT-PAC simulation package and several liquids with different percentages of Liquid Scintillator (LS) and Gadolinium (Gd) are investigated.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Light yield quenching and quenching remediation in liquid scintillator detectors

Quenching of light emission from an LAB based scintillator by the addition of organic amines and carboxylic acids is examined. Chemical functional groups of the quenching agents play an important role in this reduction. It is shown that "salt" formation at a 1:1 mole ratio in a mixed amine-acid system, reduces quenching by a factor of ~ 2. Supporting NMR spectra are presented. Finally, this "quenching neutralization" has the potential to reduce the light loss incurred when metals complexed with quenching agents are loaded into organic scintillators.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Water-based Liquid Scintillator detector as a new technology testbed for neutrino studies in Turkey

This study investigates the deployment of a medium-scale neutrino detector near Turkey's rst nuclear power plant, the Akkuyu Nuclear Power Plant. The aim of this detector is to become a modular testbed for new technologies in the elds of new detection media and innovative photosensors. Such technologies include Water-based Liquid Scintillator (WbLS), Large Area Picosecond Photo- Detectors (LAPPDs), dichroic Winston cones, and large area silicon photomul- tiplier modules. Here, the detector could be used for instantaneous monitoring of the Akkuyu Nuclear Power Plant via its antineutrino ux. In addition to its physics and technological goals, it would be an invaluable opportunity for the nuclear and particle physics community in Turkey to play a role in the development of next generation of particle detectors in the eld of neutrino physics.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Deadtime Calculations of Liquid Scintillator Neutron Detector Using Attenuation Law

Scientists have been working on deadtime problems for radiation detectors since 1940's. In detector systems, a minimum time must separate two different events before they can be measured individually. That minimum time interval is called to be deadtime of detector system. There are two commonly deadtime models: the paralyzing and the non-paralyzing models. Paralyzing model assumes that each event during the deadtime will reset the deadtime and deadtime extension will depend on the count rate. According to the non-paralyzing model, deadtime is fixed after each detected event and all events occurring during deadtime are lost. In this study, deadtime measurements have been obtained for an N-Probe fast neutron (NE-213 Liquid Scintillation) detector manufactured by BTI (Bubble Technology Industries) using a combination of the attenuation law and the assumption of ideal paralyzing and non-paralyzing method. Bubble Technology Industries (BTI) has manufactured a portable neutron scintillation spectrometer (N-Probe) with potential applications at nuclear reactor facilities, waste processing operations, and spent fuel storage areas. The deadtime of the N-Probe detector is not provided by the manufacturer; BTI, and there is no other study published on the N-Probe detector' deadtime. Since the detector will be used in future nuclear fuel investigations, it is important to determine the detector' deadtime for accurate nuclear fuel analysis. The deadtime of the BTI N-Probe was examined using different thicknesses of Plexiglas at the Missouri University of Science and Technology Reactor (MSTR) using attenuation law and average macroscopic cross-section of Plexiglas defined by both paralyzing and non-paralyzing model. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗