Search NASA⌕ Search

SEARCH · Search NASA

Results for “LN2”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Investigation of upconversion and downconversion fluorescence emissions from β-NaLn1F{sub 4}:Yb{sup 3+}, Ln2{sup 3+} (Ln1 = Y, Lu; Ln2 = Er, Ho, Tm, Eu) hexagonal disk system

Graphical abstract: Well-defined β-NaLn1F4:Yb{sup 3+}, Ln2{sup 3+} (Ln1 = Y, Lu; Ln2 = Er, Ho, Tm, Eu) hexagonal thin disks with a simple and user-friendly hydrothermal approach by using sodium citrate as a shape modifier. Much stronger UC and DC fluorescence emissions were observed in NaLuF{sub 4}-based hexagonal disks than that for NaYF{sub 4} counterparts. The strength of hypersensitive transitions is mainly attributed to the decrease of local symmetry Ln-F bond lengths in β-NaLuF{sub 4}. It will show a great potential in improving near-infrared conversion efficiency of silicon solar cells and removable sub-micro luminescent platforms. - Highlights: • Regular hexagonal disks (NaLnF{sub 4}) were synthesized by a simple hydrothermal method. • Much stronger UC and DC emissions were observed in NaLuF{sub 4}-based disks. • Stronger fluorescence emissions in NaLuF{sub 4}-based disks were explained reasonably. • NaLuF{sub 4}-based disks can act as a removable luminescent platform for nano-assembly. • NaLuF{sub 4}-based disks can be applied in improving efficiency of solar cells. - Abstract: Uniform hexagonal β-NaLn1F{sub 4}:Yb{sup 3+}, Ln2{sup 3+} (Ln1 = Y, Lu; Ln2 = Er, Ho, Tm, Eu) disks were synthesized with hydrothermal method in which the sodium citrate was used as a shape modifier. The experimental observation indicated that both upconversion and downconversion fluorescence emissions were significantly stronger in β-NaLuF{sub 4} than that for β-NaYF{sub 4}. It was found that the stronger hypersensitive transitions were mainly due to the increase of J–O parameter (Ω{sub 2}) in β-NaLuF{sub 4} host, while the stronger insensitive transitions were mainly caused by the stronger overlap of electron cloud that was induced by the decrease of Ln-F bond lengths. Additionally, the larger absorption strength in the near-infrared region is another important factor for the stronger fluorescence emissions. The current research has a great potential in improving near-infrared conversion efficiency of silicon solar cells.

36 MATERIALS SCIENCE↗

Effect of LN2 injection station location on the drive fan power and LN2 requirements of a cryogenic wind tunnel

A theoretical analysis comparing the fan power and coolant (LN2) flow rates resulting from injection of the LN2 either upstream or downstream of the drive fan of a closed circuit transonic cryogenic tunnel is presented. The analysis is restricted to steady state tunnel operation and to the condition that the tunnel walls are adiabatic. The stagnation pressure and temperature range of the tunnel is from 1.0 to 8.8 atm and from 300 K to liquefaction temperature, respectively. Calculations are made using real gas properties of nitrogen. Results show that the fan power and LN2 flow rates are lower if the LN2 is injected upstream of the fan. The lower fan inlet temperature resulting from injecting upstream of the fan has a greater influence on the power than does the additional mass flow going through the fan.

Adcock, J. B.↗

High Specific Power Motors in LN2 and LH2

A switched reluctance motor has been operated in liquid nitrogen (LN2) with a power density as high as that reported for any motor or generator. The high performance stems from the low resistivity of Cu at LN2 temperature and from the geometry of the windings, the combination of which permits steady-state rms current density up to 7000 A/cm2, about 10 times that possible in coils cooled by natural convection at room temperature. The Joule heating in the coils is conducted to the end turns for rejection to the LN2 bath. Minimal heat rejection occurs in the motor slots, preserving that region for conductor. In the end turns, the conductor layers are spaced to form a heat-exchanger-like structure that permits nucleate boiling over a large surface area. Although tests were performed in LN2 for convenience, this motor was designed as a prototype for use with liquid hydrogen (LH2) as the coolant. End-cooled coils would perform even better in LH2 because of further increases in copper electrical and thermal conductivities. Thermal analyses comparing LN2 and LH2 cooling are presented verifying that end-cooled coils in LH2 could be either much longer or could operate at higher current density without thermal runaway than in LN2.

Brown, Gerald V.↗

High Specific Power Motors in LN2 and LH2

A switched reluctance motor has been operated in liquid nitrogen (LN2) with a power density as high as that reported for any motor or generator. The high performance stems from the low resistivity of Cu at LN2 temperature and from the geometry of the windings, the combination of which permits steady-state rms current density up to 7000 A/sq cm, about 10 times that possible in coils cooled by natural convection at room temperature. The Joule heating in the coils is conducted to the end turns for rejection to the LN2 bath. Minimal heat rejection occurs in the motor slots, preserving that region for conductor. In the end turns, the conductor layers are spaced to form a heat-exchanger-like structure that permits nucleate boiling over a large surface area. Although tests were performed in LN2 for convenience, this motor was designed as a prototype for use with liquid hydrogen (LH2) as the coolant. End-cooled coils would perform even better in LH2 because of further increases in copper electrical and thermal conductivities. Thermal analyses comparing LN2 and LH2 cooling are presented verifying that end-cooled coils in LH2 could be either much longer or could operate at higher current density without thermal runaway than in LN2.

Brown, Gerald V.↗

Infrared detector Dewars - Increased LN2 hold time and vacuum jacket life spans

IR detector Dewars commonly suffer from shorter than desired LN2 hold times and insulation jacket vacuum corruption over relatively short time periods. In an attempt to solve this problem for a 9144 detector Dewar, small 1 liter/s appendage ion pumps were selected for continuous pumping of the vacuum jackets. This procedure extended LN2 hold times from 20 to 60 h and virtually eliminated vacuum jacket corruption. Thus the detector systems are usable continuously over periods of 6 months or more.

Jennings, D. E.↗

Brush Seals for Cryogenic Applications: Performance, Stage Effects, and Preliminary Wear Results in LN2 and LH2

Brush seals are compliant contacting seals and have significantly lower leakage than labyrinth seals in gas turbine applications. Their long life and low leakage make them candidates for use in rocket engine turbopumps. Brush seals, 50.8 mm (2 in.) in diameter with a nominal 127-micron (0.005-in.) radial interference, were tested in liquid nitrogen (LN2) and liquid hydrogen (LH2) at shaft speeds up to 35,000 and 65,000 rpm, respectively, and at pressure drops up to 1.21 MPa (175 psid) per brush. A labyrinth seal was also tested in liquid nitrogen to provide a baseline. The LN2 leakage rate of a single brush seal with an initial radial shaft interference of 127 micron (0.005 in.) measured one-half to one-third the leakage rate of a 12-tooth labyrinth seal with a radial clearance of 127 micron (0.005 in.). Two brushes spaced 7.21 micron (0.248 in.) apart leaked about one-half as much as a single brush, and two brushes tightly packed together leaked about three-fourths as much as a single brush. The maximum measured groove depth on the Inconel 718 rotor with a surface finish of 0.81 micron (32 microinch) was 25 micron (0.0010 in.) after 4.3 hr of shaft rotation in liquid nitrogen. The Haynes-25 bristles wore approximately 25 to 76 micron (0.001 to 0.003 in.) under the same conditions. Wear results in liquid hydrogen were significantly different. In liquid hydrogen the rotor did not wear, but the bristle material transferred onto the rotor and the initial 127 micron (0.005 in.) radial interference was consumed. Relatively high leakage rates were measured in liquid hydrogen. More testing is required to verify the leakage performance, to validate and calibrate analysis techniques, and to determine the wear mechanisms. Performance, staging effects, and preliminary wear results are presented.

Proctor, Margaret P.↗

Case Study of Using Flocad to Model a Ground Test Station Ln2 Heat Exchanger

This paper presents a case study of using FLOCAD to model the heat transfer and boiling flow behavior of a Liquid Nitrogen (LN2) ground station equipment heat exchanger. The unique aspect of this work is that is one of very few studies documenting the use of FLOCAD in the spacecraft thermal control community. The results of the simulations described herein were used to guide and plan the execution of thermal vacuum testing spacecraft hardware using a ground test heat exchanger such as the one modeled herein. The paper will review the theory of two-phase boiling flow and correlations used by SINDA/FLUINT as well as the terminology and nomenclature used within Thermal Desktop / FLOCAD regarding two-phase boiling flow heat transfer modeling and simulation. Results for using the ground station heat exchanger as a heat sink in a thermal vacuum test set up are shown in order to demonstrate the set-up and execution of a typical FLOCAD model. Results indicate that properly modeling of the two-phase behavior is critical in order to ascertain the time constant associated with the heat exchanger, as well as understanding the temperature distribution across the test equipment and prediction of required LN2 flowrates to be used during testing. The paper is meant to augment the FLOCAD user’s manual and serve as a tutorial for thermal engineers and analysts wishing to learn and apply FLOCAD to industrial problems.

Anderson, Kevin R.↗

Modeling and control of a LN2-GN2 operated closed circuit cryogenic wind tunnel

An explicit but simple lumped parameter nonlinear multivariable model of a LN2-GN2-operated closed circuit cryogenic wind tunnel has been developed and its basic features have been experimentally validated. The model describes the mass-energy interaction involved in the cryogenic tunnel process and includes the real gas properties of nitrogen gas.

Balakrishna, S.↗

Predictions of Line Chilldown Boiling Regime Transitions by a Coupled CFD-Sub-Grid Boiling Model Validated against 1G LN2 Experiments

Propellant storage and transfer during future long-duration missions will involve fuel depot operations in which a donor depot tank is used to fill a receiver spacecraft tank with a cryogenic propellant. Prior to the on-Orbit filling operation both the receiver tank and the transfer line must be cooled. The line chilldown process involves transition between boiling regimes in microgravity that will be quite different from their 1g ground-based counterparts. Since the cryogenic propellant itself will be used to perform the chilldown process, the time constants to cool the wall and the amount of fuel that will be used become important design considerations. In this light, the focus of the present work is to capture the flow boiling characteristics of a cryogenic fluid, namely, liquid nitrogen, during the chill-down of a transfer line using CFD modelling and simulations. The cryogenic chill-down process involves different flow boiling regimes: film boiling, transition boiling and nucleate boiling. The prediction of transition between these regimes in a CFD framework is new and challenging. The present work addresses this challenge by employing a volume-of-fluid (VOF) based methodology with Lee phase change model to predict the film boiling regime of the chill-down process in ANSYS Fluent®. The transition and nucleate boiling regimes are predicted by incorporating a sub-grid model that accounts for bubble nucleation, growth, shedding frequency, and departure diameter. The sub-grid model is implemented into Fluent via a user-defined function for wall-fluid heat flux calculations. The sub-grid model is similar in formulation to the well-known Rensselaer Polytechnic Institute (RPI) boiling model. The CFD model is validated against published experimental data for liquid nitrogen chill-down of a heated stainless-steel pipe in 1g. Predicted results shows good agreement of wall temperature, rewetting temperature, and transition between film and nucleate boiling with the experimental measurements for several different LN2 flowrates in the vertical orientation. The strengths and weaknesses of this modeling approach are presented and discussed.

Cryogenic Fluid Management↗

CFD Predictions of Boiling Regime Transitions during Line Chilldown validated against a 1G LN2 Experiment

Introduction Before filling a propellant tank on the ground or in Space, the transfer line between the donor and receiver tanks must be cooled down preferably by sacrificing a minimum amount of the cryogenic fluid. The cryogenic line chill-down process involves a transition between different flow boiling regimes, namely, film boiling, transition film boiling, and nucleate boiling which are complex and may be quite gravity-dependent. Capturing these boiling phenomena and predicting the transition between them in a CFD framework is new and challenging both for 1g and microgravity applications. Materials & Methods The present work addresses this challenge by employing a two-phase Eulerian approach in the context of a homogeneous fluid mixture together with the Lee phase change model to capture the film boiling regime of the chill-down process using ANSYS Fluent®. The nucleate boiling regime is predicted by incorporating an in-house developed sub-grid model that accounts for bubble nucleation, bubble growth, bubble departure diameter, and their shedding frequency. The sub-grid model is encoded and implemented into Fluent via a user-defined function for the wall-fluid heat flux calculations. The mathematical formulation and numerical implementation of the CFD model are described in detail. The coupled CFD-Subgrid model is validated against published experimental data for liquid nitrogen chill-down of a heated stainless-steel pipe in 1g. Results Numerical simulation results show good agreements between the CFD predictions of the wall temperature evolution, rewetting temperature, and transition between film and nucleate boiling, with the experimental measurements published by Darr et al [2] for several different LN2 flowrates in the vertical pipe orientation. The CFD predictions for the wall temperature distribution indicate a rapid quenching of the wall at two upstream and downstream temperature sensing locations as compared to the experimental measurement. The only tuning parameter in the CFD model is the Lee mass transfer coefficient. The CFD Model predicts the Liedenfrost rewetting temperature in close agreement with the experiment. This marks a transition between stable and transitionary flow boiling regimes. The CFD-predicted boiling curve for the downstream sensor location is also compared against its experimental counterpart and indicates that the model is able to predict all the key temperature and heat flux parameters during the transitions from stable to transitionary film boiling to nucleate boiling in close agreement with the experiment. A sequence of predicted volume fraction, and temperature contours depicting these transitions will be presented.

Evaporation Condensation↗

Improved Performance of a Temperature Compensated LN2 Cooled Sapphire Oscillator

We report on improved stability in a whispering gallery sapphire resonator for which the dominant WGHn11 microwave mode family shows frequency-stable, compensated operation for temperatures above 77K. Several modifications during the past year have led to significant improvements in performance. Current tests with improved thermal stability provide Allan Deviation of frequency of 2.6 - 4 ? 10-13 for measurement times of 1#t#100 seconds. We project a frequency stability of 1014 for this resonator with stabilized housing temperature and with a mode Q of 107.!.

Temperature Compensated LN2 Cooled Sapphire Oscill↗

Boiling heat transfer to LN2 and LH2 - Influence of surface orientation and reduced body forces

The quantitative determination of the influence of heater surface orientation and gravity on nucleate pool boiling of liquid nitrogen and liquid hydrogen is described. A transient calorimeter technique, well suited for obtaining pool boiling data under reduced gravity and used earlier by Clark and Merte (1963), was employed after being adapted to flat a surface whose orientation could be varied. The obtained determination results are reviewed.

Merte, H., Jr.↗

The effects of exposure to LN2 temperatures and 2.5 suns solar radiation on 30-cm ion thruster performance

An experimental test program was developed to demonstrate all 30 cm Hg-ion bombardment thruster functions over the thermal environment of several proposed missions. A 30 cm thruster with grids dished 1.25 cm and instrumented with 31 thermocouples, was placed in a vacuum tank equipped with minus 196 C walls. Cold storage of a thruster was simulated and temperatures as low as minus 100 C were attained on the thruster. The thruster started successfully from these cold conditions. The thruster operating at both half and full beam power was exposed to 2.5 suns on axis solar simulation. Various thruster thermal configurations, used to simulate multiple thruster operation, were tested at the above conditions. The results of these tests are reported herein.

Mirtich, M. J.↗

The effects of exposure to LN2 temperatures and 2.5 suns solar radiation on 30-cm ion thruster performance

An experimental test program was developed to demonstrate all 30 cm Hg-ion bombardment thruster functions over the thermal environment of several proposed missions. A 30 cm thruster with grids dished 1.25 cm and instrumented with 31 thermocouples, was placed in a vacuum tank equipped with -196 C walls. Cold storage of a thruster was simulated and temperatures as low as -100 C were attained on the thruster. The thruster started successfully from these cold conditions. The thruster operating at both half and full beam power was exposed to 2.5 suns on axis solar simulation. Various thruster thermal configurations, used to simulate multiple thruster operation, were tested at the above conditions. The results of these tests are reported herein.

Mirtich, M. J.↗

LN2 spray droplet size measurement via ensemble diffraction technique

The size of subcooled liquified nitrogen droplets are measured with a 5 mW He-Ne laser as a function of pressure difference (delta P) across flat spray and full cone pressure atomizing nozzles. For delta P's of 3 to 30 psid, the spray sauter mean diameter (SMD) ranged between 250 to 50 microns. The pressure range tested is representative of those expected during cryogenic fluid transfer operations in space. The droplet sizes from the flat spray nozzles were greater than those from the full cone nozzle. A power function of the form, SMD varies as delta P(exp a), describes the spray SMD as a function of the delta P very well. The values of a were -0.36 for the flat spray and -0.87 for the full cone. The reduced dependence of the flat spray SMD on the delta P was probably because of: (1) the absence of a swirler that generates turbulence within the nozzle to enhance atomization, and (2) a possible increase in shearing stress resulting from the delayed atomization due to the absence of turbulence. The nitrogen quality, up to 1.5 percent is based on isenthalpic expansion, did not have a distinct and measurable effect on the spray SMD. Both bimodal and monomodal droplet size population distributions were measured. In the bimodal distribution, the frequency of the first mode was much greater than the frequency of the second mode. Also, the frequency of the second mode was low enough such that a monomodal approximation probably would give reasonable results.

Saiyed, N. H.↗

LN2 spray droplet size measurement via ensemble diffraction technique

The size of subcooled liquified nitrogen droplets are measured with a 5 mW He-Ne laser as a function of pressure difference (delta P) across flat spray and full cone pressure atomizing nozzles. For delta P's of 3 to 30 psid, the spray sauter mean diameter (SMD) ranged between 250 to 50 microns. The pressure range tested is representative of those expected during cryogenic fluid transfer operations in space. The droplet sizes from the flat spray nozzles were greater than those from the full cone nozzle. A power function of the form, SMD varies as delta P(exp a), describes the spray SMD as a function of the delta P very well. The values of a were -0.36 for the flat spray and -0.87 for the full cone. The reduced dependence of the flat spray SMD on the delta P was probably because of: (1) the absence of a swirler that generates a turbulence within the nozzle to enhance atomization, and (2) a possible increase in shearing stress resulting from the delayed atomization due to the absence of turbulence. The nitrogen quality, up to 1.5 percent is based on isenthalpic expansion, did not have a distinct and measurable effect on the spray SMD. Both bimodal and monomodal droplet size population distributions were measured. In the bimodal distribution, the frequency of the first mode was much greater than the frequency of the second mode. Also, the frequency of the second mode was low enough such that a monomodal approximation probably would give reasonable results.

Saiyed, N. H.↗

Dynamic Mechanical Properties and Fracture Surface Morphologies of Core-Shell Rubber (CSR) Toughened Epoxy at Liquid Nitrogen (Ln2) Temperatures

The dynamic mechanical properties and fracture surface morphologies were evaluated for a commercial epoxy resin toughened with two types of core-shell rubber (CSR) toughening agents (Kane Ace(Registered TradeMark) MX130 and MX960). The impact resistance (R) was evaluated by the resulting breaking energy measured in Charpy impact tests conducted on an instrumented drop tower. The resulting fracture surface morphologies were examined using Scanning Electron Microscopy (SEM). Fractographic observations of the CSR toughened epoxy tested at ambient temperature, showed a fracture as characterized by slender dendrite textures with large voids. The increasing number of dendrites and decreasing size of scale-like texture with more CSR particles corresponded with increased R. As the temperature decreased to Liquid Nitrogen (LN 2), the fracture surfaces showed a fracture characterized by a rough, torn texture containing many river markings and deep furrows.

Wang, J.↗