A load factor formula

The ultimate test of a load factor formula is experience. The chief advantages of a semi rational formula over arbitrary factors are that it fairs in between points of experience and it differentiates according to variables within a type. Structural failure of an airplane apparently safe according to the formula would call for a specific change in the formula. The best class of airplanes with which to check a load factor formula seems to be those which have experienced structural failure. Table I comprises a list of the airplanes which have experienced failure in flight traceable to the wing structure. The load factor by formula is observed to be greater than the designed strength in each case, without a single exception. Table II comprises the load factor by formula with the designed strength of a number of well-known service types. The formula indicates that by far the majority of these have ample structural strength. One case considered here in deriving a suitable formula is that of a heavy load carrier of large size and practically no reserve power.

Miller, Roy G↗

A piloted simulation investigation of the normal load factor and longitudinal thrust required for air-to-air acquisition and tracking

A piloted simulation study was performed by the U.S. Army Aeroflighydynamics Directorate to develop insight into the maneuverability requirements for aggressive helicopter maneuvering tasks such as air-to-air combat. Both a conventional helicopter and a helicopter with auxiliary thrust were examined. The aircraft parameters of interest were the normal and longitudinal load factor envelopes. Of particular interest were the mission performance and handling qualities tradeoffs with the parameters of interest. Two air-to-air acquisition and tracking tasks and a return-to-cover task were performed to assess mission performance. Results indicate that without auxiliary thrust, the ownship normal load factor capability needs to match that of the adversary in order to provide satisfactory handling qualities. Auxiliary thrust provides significant handling qualities advantages and can be substituted to some extent for normal load factor capability. Auxiliary thrust levels as low as 0.2 thrust/weight can provide significant handling qualities advantages.

Whalley, Matthew S.↗

Calculated Normal Load Factors on Light Airplanes Traversing the Trailing Vortices of Heavy Transport Airplanes

Results are presented of normal-load-factor calculations made for a lightnormal-category airplane and a light transport-category airplane traversing the trailing vortices generated by each of three heavy transport airplanes. With each light airplane, the normal load factors were determined for several penetration paths lying i n a plane perpendicular to the trailing vortices and for three center-of-gravity locations and velocities. Also determined for the light normal-category airplane were the elevator deflections required to maintain 1 g flight and the vertical displacements of the airplane from the prescribed penetration paths while transversing the vortices.

McGowan, William A.↗

Cold-air investigation of first stage of 4-1/2-stage, fan drive turbine with average stage-loading factor of 4.66

The design procedure and the development of the blading geometry for the 4 and 1/2 stage turbine are discussed. Results obtained with the first stage, operated as a single stage turbine, are presented. A free vortex design meets the design requirements without incurring problems such as excessive turning, negative reaction, or high Mach number. Cold air tests of the single stage turbine showed that the turbine developed design work (stage loading factor of 5.26) at an efficiency of 0.86, which was the efficiency predicted by a reference method. The mass flow at this condition was 0.88, which occurred at design speed and a pressure ratio of 1.407, corresponding to a stage loading factor of 4.35. The efficiency at this condition was 0.003 higher than that predicted by the reference method.

Whitney, W. J.↗

Experimental investigation of a 4 and 1/2 stage turbine with very high stage loading factor. 2: Turbine performance

The experimental test program results of a 4 1/2-stage turbine with a very high stage loading factor are presented. A four-stage turbine was tested with and without outlet turning vanes. The 4 1/2-stage turbine achieved a design point total-to-total efficiency of 0.853. The outlet turning vane design point performance was 0.4 percent of the overall 4 1/2-stage turbine efficiency. Tests were conducted at various levels of Reynolds number and indicated decreases in turbine efficiency and equivalent weight flow with decreasing Reynolds number.

Walker, N. D.↗

Cold-air investigation of a 4 1/2 stage turbine with stage-loading factor of 4.66 and high specific work output. 2: Stage group performance

The stage group performance of a 4 1/2 stage turbine with an average stage loading factor of 4.66 and high specific work output was determined in cold air at design equivalent speed. The four stage turbine configuration produced design equivalent work output with an efficiency of 0.856; a barely discernible difference from the 0.855 obtained for the complete 4 1/2 stage turbine in a previous investigation. The turbine was designed and the procedure embodied the following design features: (1) controlled vortex flow, (2) tailored radial work distribution, and (3) control of the location of the boundary-layer transition point on the airfoil suction surface. The efficiency forecast for the 4 1/2 stage turbine was 0.886, and the value predicted using a reference method was 0.862. The stage group performance results were used to determine the individual stage efficiencies for the condition at which design 4 1/2 stage work output was obtained. The efficiencies of stages one and four were about 0.020 lower than the predicted value, that of stage two was 0.014 lower, and that of stage three was about equal to the predicted value. Thus all the stages operated reasonably close to their expected performance levels, and the overall (4 1/2 stage) performance was not degraded by any particularly inefficient component.

Whitney, W. J.↗

Preliminary Study of Applied Load Factors in Bumpy Air

Theoretical relations involved in the study are reviewed to furnish a basis upon which experimental data can be properly analyzed. The structure of the atmosphere in relation to the load-factor problem is briefly discussed, and the acceleration data obtained on a number of flights with various airplanes are presented and analyzed to the extent that the results are applicable to n=any airplane.

Rhode, Richard V↗

Cold-air investigation of a 3 1/2-stage fan-drive turbine with a stage loading factor of 4 designed for an integral lift engine. 1: Turbine design and performance of first stage

The design of the 3 1/2-stage turbine is described, and the cold-air performance of the first stage, modified for axial inlet conditions, is presented. The performance of the modified single-stage turbine and of two comtemporary high-stage-loading-factor turbines is compared with that estimated with a reference prediction method.

Whitney, W. J.↗

Cold-air investigation of a 31/2-stage fan-drive turbine with a stage loading factor of 4 designed for an integral lift engine. 2: Performance of 2-, 3- and 3 1/2-stage configurations

The stage work distribution among the three stages was very close to the design value. The specific work output-mass flow characteristics of the three stages were closely matched. The efficiency of the 3 1/2 stage turbine at design specific work output and design speed was within 0.008 of the estimated value, and this agreement was felt to demonstrate the adequacy of the prediction method in the high stage loading factor regime.

Whitney, W. J.↗

Cold air investigation of 4 1/2-stage turbine with stage loading factor of 4.66 and high specific work output. 1: Overall performance

The turbine developed design specific work output at design speed at a total pressure ratio of 6.745 with a corresponding efficiency of 0.855. The efficiency (0.855)was 3.1 points lower than the estimated efficiency quoted by the contractor in the design report and 0.7 of a point lower than that determined by a reference prediction method. The performance of the turbine, which was a forced vortex design, agreed with the performance determined by the prediction method to about the same extent as did the performance of three reference high stage loading factor turbines, which were free vortex designs.

Whitney, W. J.↗