Search NASA⌕ Search

SEARCH · Search NASA

Results for “LOCK-IN AMPLIFIERS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Deriving Material Properties from Feedback Error Signals in Scanning Tunneling Microscopy

Imperfections in measurements, e.g., deviations and broadening, are not devoid of information; rather, they can reveal valuable physical properties and processes. Scanning tunneling microscopy leverages a negative feedback loop to regulate the tunneling current. Practically, current fluctuates around its set point, and such deviations are considered insignificant and ignored. Here, in this study, we investigate the information embedded in these deviations. In the constant-current mode with an active feedback loop, we observe an unexpected persistent DC current offset from its set point when the tunneling junction is periodically perturbed. We demonstrate both experimentally and theoretically that such error signals encode local tunneling barrier heights and the square of local differential conductance as a consequence of the interplay between rectification and active feedback compensation. We provide evidence on the generalizability of this phenomenology to other negative feedback systems. This new approach has the potential to broadly impact physical sciences by allowing rapid measurements without lock-in amplifiers.

36 MATERIALS SCIENCE↗

AC electrical transport detection of magnetic properties of small, granular, and heterogeneous samples

Experimental constraints and sample limitations can preclude ideal measurements of electrical transport properties of materials. In such situations, AC electrical transport methods are often employed due to a significant increase in signal-to-noise ratio they can provide. However, dynamic effects that are not often accounted for may be present that may modify the signals in these measurements. In particular, dynamic filtering effects are prominent in small, granular, and heterogeneous materials. We demonstrate that a lock-in amplifier based circuit can distinguish between these DC transport and AC filtering effects. Here, we further demonstrate that this filtering can reveal distinct signatures of magnetic transitions while providing a measure of sample quality.

47 OTHER INSTRUMENTATION↗

Compact carbon monoxide sensor utilizing a confocal optical cavity.

The carbon monoxide sensor discussed in this paper utilizes a unique confocal cavity which allows the complete system to be packaged in a small volume suitable for hand-held use. The optical system is the heart of the instrument with equal emphasis placed on the electronics support circuitry, consisting essentially of a thermal infrared pyroelectric detector and lock-in amplifier. The pyroelectric detector offers a major advantage over other thermal detectors, providing a signal-to-noise ratio and detectivity that remain nearly constant over the frequency range from dc to 2000 Hz. Since bias voltage is not required, low frequency noise is not generated in the detector.

Scott, B.↗

Photoelectron spectrometer with means for stabilizing sample surface potential

An improved X-ray photoelectron spectrometer is disclosed, which includes circuit means to determine the surface potential of a sample, e.g., an insulator. The circuit means comprise an electron gun, whose potential is modulated at a preselected frequency above and below a selected potential with respect to the spectrometer common potential, e.g., ground. The beam of electrons is directed to the sample surface. The sample's surface potential is offset by an offset power supply with respect to the spectrometer common potential until the ac current which flows through the sample reaches a peak amplitude. A lock-in amplifier is included to measure the ac current in phase with the modulating frequency.

Grunthaner, F. J.↗

Laser optogalvanic spectroscopy of molecules

In laser optogalvanic (LOG) spectroscopy, a tunable laser is used to probe the spectral characteristics of atomic or molecular species within an electrical discharge in a low pressure gas. Optogalvanic signals arise when the impedance of the discharge changes in response to the absorption of laser radiation. The technique may, therefore, be referred to as impedance spectroscopy. This change in impedance may be monitored as a change in the voltage across the discharge tube. LOG spectra are recorded by scanning the wavelength of a chopped CW dye laser while monitoring the discharge voltage with a lock-in amplifier. LOG signals are obtained if the laser wavelength matches a transition in a species present in the discharge (or flame), and if the absorption of energy in the laser beam alters the impedance of the discharge. Infrared LOG spectroscopy of molecules has been demonstrated and may prove to be the most productive application in the field of optogalvanic techniques.

Webster, C. R.↗

Measurement of the J = 0-1 rotational transitions of three isotopes of ArD(+)

The rotational transitions of all three isotopic species of ArD(+) in samples containing the Ar isotopes in their natural abundances have been measured by means of millimeter and submillimeter techniques that employ a magnetically enhanced abnormal glow discharge. All three transition frequency measurements were made from digitally averaged signals detected through a lock-in amplifier with a 10-msec time constant. The Ar-4OD(+) transition was easily visible in real time on an oscilloscope with SNR of about 15. It is noted that the observed transition of Ar-38D(+) is more than five orders of magnitude weaker than that due to HCO(+).

Bowman, W. C.↗

Spectrophone stabilized laser with line center offset frequency control

Continuous offset tuning of a frequency stabilized CW gas laser is achieved by using a spectrophone filled with the same gas as the laser for sensing a dither modulation, detecting a first or second derivative of the spectrophone output with a lock-in amplifier, the detected output of which is integrated, and applying the integrator output as a correction signal through a circuit which adds to the dither signal from an oscillator a dc offset that is adjusted with a potentiometer to a frequency offset from the absorption line center of the gas, but within the spectral linewidth of the gas. Tuning about that offset frequency is achieved by adding a dc value to the detected output of the dither modulation before integration using a potentiometer.

Kavaya, M. J.↗

Development of an apparatus for obtaining molecular beams in the energy range from 2 to 200 eV

The formation and detection of molecular beams obtained by charge exchange from a low-energy ion source is discussed. Dispersion in energy of the ion source was measured and problems concerning detection of neutral beams were studied. Various methods were used, specifically secondary electron emissivity of a metallic surface and ionization of a gas target with a low ionization voltage. The intensities of neutral beams as low as 10 eV are measured by a tubular electron multiplier and a lock-in amplifier.

Clapier, R.↗

Carbon monoxide production in low energy oxygen ion bombardment of pyrolytic graphite and Kapton surfaces

The results of an investigtion of the interaction of low energy oxygen ions with pyrolytic graphite and Kapton surface are reported. CO molecules emitted from the surface as a result of the ion bombardment were detected by a mass spectrometer. Because the ion-induced signals were small compared to that arising from the CO background pressure in the vacuum system, the ion beam was modulated and the modulated component of the CO signal measured with a lock-in amplifier. The quantum yield (CO molecules emitted per incident oxygen ion) for graphite rose from 1.9 at 4.5 eV ion energy to 6.6 at 465 eV. Comparable yields were obtained for Kapton. The large size of the yields suggests contributions to the reaction process from the background O2 molecules in the vacuum system.

Horton, C. C.↗

Investigation of hard targets for calibration of a coherent Doppler lidar system

The bihemispherical reflectance has been measured for a diffuse gold surface the same as the coating on the integrating sphere, flowers of sulfur, sandblasted aluminum, and 120 grade aluminum oxide sandpaper. The sandpaper measurements indicate that materials with low reflectance cannot be measured until more sensitive detection techniques are found. The sphere had to be used without a detector baffle so an unusual geometry was needed that led to a loss of intensity. Further, it is estimated that some first-strike light entered the detector and the readings could be 1 to 1.5% too low. A limited number of normal incident directional-hemispherical reflectance measurements were made on aluminum and sandpaper. Several recommendations are made: (1) the proper baffle placement; (2) improve lock-in detection using a PAR lock-in amplifier or the heterodyne technique; (3) modification of the sphere so the sample may be mounted at the cell center on a graduate, rotatable table for measurement of directional-hemispherical reflectance; (4) the purchase of additional diffuse gold samples with coatings like the sphere; and (5) better laser temperature control to improve intensity stability.

Anderson, Richard↗

Chopping-Wheel Optical Attenuator

Star-shaped rotating chopping wheel provides adjustable time-averaged attenuation of narrow beam of light without changing length of optical path or spectral distribution of light. Duty cycle or attenuation factor of chopped beam controlled by adjusting radius at which beam intersects wheel. Attenuation factor independent of wavelength. Useful in systems in which chopping frequency above frequency-response limits of photodetectors receiving chopped light. Used in systems using synchronous detection with lock-in amplifiers.

Leviton, Douglas B.↗

Steady-state evoked potentials possibilities for mental-state estimation

The use of the human steady-state evoked potential (SSEP) as a possible measure of mental-state estimation is explored. A method for evoking a visual response to a sum-of-ten sine waves is presented. This approach provides simultaneous multiple frequency measurements of the human EEG to the evoking stimulus in terms of describing functions (gain and phase) and remnant spectra. Ways in which these quantities vary with the addition of performance tasks (manual tracking, grammatical reasoning, and decision making) are presented. Models of the describing function measures can be formulated using systems engineering technology. Relationships between model parameters and performance scores during manual tracking are discussed. Problems of unresponsiveness and lack of repeatability of subject responses are addressed in terms of a need for loop closure of the SSEP. A technique to achieve loop closure using a lock-in amplifier approach is presented. Results of a study designed to test the effectiveness of using feedback to consciously connect humans to their evoked response are presented. Findings indicate that conscious control of EEG is possible. Implications of these results in terms of secondary tasks for mental-state estimation and brain actuated control are addressed.

Junker, Andrew M.↗

Integrated Solar Disk Oscillation Measurements Using the Magneto-Optical Filter: Tests with a Two Station Network

The magneto-optical filter (MOF) was used to get high and intermediate l-modes of solar oscillations. For very low l-modes the imaging capability of the MOF is still attractive since it allows a pixel by pixel intensity normalization. However, a crude attempt to get very low l power spectra from Dopplergrams obtained at Mt. Wilson gave noisy results. This means that a careful analysis of all the factors potentially affecting high resolution Dopplergrams should be accomplished. In order to better investigate this problem, a nonimaging channel using the lock-in amplifier technique was considered. Two systems are now operational, one at JPL and the other at University of Rome. Observations in progress are used to discuss the MOF stability, the noise level, and the possible application in asteroseismology.

Cacciani, Alessandro↗

Preparation of a second station for the measurement of solar oscillations of low degree 'l'

An observing station to detect low-degree global solar oscillations is already operational at the Jet Propulsion Laboratory. A second station for continuative measurements of such oscillations has recently been installed and successfully tested in Rome. The high transmission and stability of the magneto-optical filter (MOF) coupled with the lock-in amplifier technique allow analog and real-time detection of oscillation modes with a noise level of only a few cm/s. Observing runs and estimates of the signal-to-noise ratio are shown in time and frequency domains. Routine observations will establish whether the MOF sensitivity and stability are suitable for the detection of stellar oscillations.

Cacciani, A.↗

Double-modulation spectroscopy of molecular ions - Eliminating the background in velocity-modulation spectroscopy

Velocity-modulation spectroscopy is an established technique for performing laser absorption spectroscopy of molecular ions in a discharge. However, such experiments are often plagued by a coherent background signal arising from emission from the discharge or from electronic pickup. Fluctuations in the background can obscure the desired signal. A simple technique using amplitude modulation of the laser and two lock-in amplifiers in series to detect the signal is demonstrated. The background and background fluctuations are thereby eliminated, facilitating the detection of molecular ions.

Lan, Guang↗

Measurement of the temperature coefficient of ratio transformers

We have measured the temperature coefficient of the output of several ratio transformers at ratios near 0.500,000 using an ac bridge and a dual-phase, lock-in amplifier. The two orthogonal output components were each resolved to +/- ppb of the bridge drive signal. The results for three commercial ratio transformers between 20 and 50 C range from 0.5 to 100 ppb/K for the signal component in phase with the bridge drive, and from 4 to 300 ppb/K for the quadrature component.

Briggs, Matthew E.↗

Stress Tuning of Laser Crystals

The topic of stress tunable laser crystals is addressed in this study with the purpose of determining the piezo-optic coefficients of a new laser material. This data was collected using a quadruple pass birefringence technique because of its high degree of sensitivity relative to the other methods examined including fringe shift analysis using a Mach-Zender interferometer. A green He-Ne laser was passed through a light chopper and Glan-Thompson prism before entering a crystal of Erbium doped Yttrium Aluminum Garnet (Er:YAG) (used in order to validate the experimental technique). The Er:YAG crystal is mounted in a press mechanism and the laser is quadruple passed through test specimen before being returned through the prism and the orthogonally polarized portion of the beam measured with a optical sensor. At a later stage, the Er:YAG crystal was replaced with a new crystal in order to determine the piezo-optic coefficients of this uncharacterized material. The applied load was monitored with the use of a 50 lb. load cell placed in line with the press. Light transmission readings were taken using a lock-in amplifier while load cell measurements were taken with a voltmeter from a 5 volt, 0.5 amp power supply. Despite the fact that an effective crystal press damping system was developed, size limitations precluded the use of the complete system. For this reason, data points were taken only once per full turn so as to minimize the effect of non uniform load application on the collected data. Good correlation was found in the transmission data between the experimentally determined Er:YAG and the previously known peizo-optic constants of non-doped crystal with which it was compared. The variation which was found between the two could be accounted for by the aforementioned presence of Erbium in the experimental sample (for which exact empirical data was not known). The same test procedure was then carried out on a Yttrium Gallium Aluminum garnet (YGAG) for the purpose of establishing values of its unknown piezo-optic constant tensor using experimentally collected transmission data. Significant variation between the piezo-optic constants of YAG and YGAG crystals was found however, the excellent data correlation of separate experimental runs carried out on the YGAG sample demonstrates the validity of these results. The data collected during the stressing of the YGAG was of high quality, however the amount of data collected was somewhat limited by a fracture of YGAG specimen which undoubted altered the crystalline lattice structure and hence precluded any further testing.

Carty, Atherton A.↗

Diode Laser Velocity Measurements by Modulated Filtered Rayleigh Scattering

The ability of solid-state lasers to be tuned in operating frequency at MHz rates by input current modulation, while maintaining a relatively narrow line-width, has made them useful for spectroscopic measurements. Their other advantages include low cost, reliability, durability, compact size, and modest power requirements, making them a good choice for a laser source in micro-gravity experiments in drop-towers and in flight. For their size, they are also very bright. In a filtered Rayleigh scattering (FRS) experiment, a diode laser can be used to scan across an atomic or molecular absorption line, generating large changes in transmission at the resonances for very small changes in frequency. The hyperfine structure components of atomic lines of alkali metal vapors are closely spaced and very strong, which makes such atomic filters excellent candidates for sensitive Doppler shift detection and therefore for high-resolution velocimetry. In the work we describe here we use a Rubidium vapor filter, and work with the strong D(sub 2) transitions at 780 nm that are conveniently accessed by near infrared diode lasers. The low power output of infrared laser diodes is their primary drawback relative to other laser systems commonly used for velocimetry. However, the capability to modulate the laser frequency rapidly and continuously helps mitigate this. Using modulation spectroscopy and a heterodyne detection scheme with a lock-in amplifier, one can extract sub-microvolt signals occurring at a specific frequency from a background that is orders of magnitude stronger. The diode laser modulation is simply achieved by adding a small current modulation to the laser bias current. It may also be swept repetitively in wavelength using an additional lower frequency current ramp.

Mach, J. J.↗