Search NASA⌕ Search

SEARCH · Search NASA

Results for “LOCK-IN AMPLIFIERS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

SILIA: software implementation of a multi-channel, multi-frequency lock-in amplifier for spectroscopy and imaging applications

In this work, we describe a software implementation of a multi-channel, multi-frequency Lock-in Amplifier (SILIA) to extract modulated signals from noisy data distributed over multiple channels of arbitrary number and size. This software implementation emulates the functionality of a multi-channel, multi-frequency lock-in amplifier in a post-processing step following data acquisition. Unlike most traditional lock-in amplifiers, SILIA can work with any number of input channels and is especially useful to analyze data distributed over many channels. We demonstrate the versatility and performance for extracting weak signals in spectroscopy and fluorescence microscopy. We also discuss more general applications and exhibit a method to automatically estimate error from a lock-in result.

47 OTHER INSTRUMENTATION↗

A 3D-Printed Microresonator Based on the Quartz-Enhanced Photoacoustic Spectroscopy Sensor for Methane Detection

A 3D-printed microresonator based on a quartz tuning fork has been developed. The sensor performance is evaluated by detection of methane with a fiber-coupled distributed feedback diode laser. In combination with wavelength modulation spectroscopy, a minimum detectable concentration of 15.6 ppb by volume is achieved at atmospheric pressure with an 8-mW average optical excitation power and a lock-in amplifier time constant of 1 s, which corresponds to a 1σ normalized noise equivalent absorption coefficient of 5·10{sup –9} cm{sup –1}·W/Hz{sup 1/2}. An Allan variance analysis shows that the system has long-term stability and can serve as the basis for a portable gas analyzer. Approaches to improve the current sensor performance are also discussed. This design greatly reduces the time of manufacturing the microresonator.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Determining moisture content of Traditional Chinese Medicines using a near-infrared LED-based moisture content sensor with spectrum analysis

In Traditional Chinese Medicine (TCM), moisture content (MC) inspection using voltage level or a lock-in amplifier, with a features-based near-infrared light-emitting diode sensor is possible. Abundant absorption response in a wide frequency range and information in both the time-domain and frequency-domain can be obtained, with the square excitation method. However, planeness, heterogeneous particle sizes, and measurement noise negatively affect the time-domain feature during MC inspection. In this work, spectrum analysis (SA) for feature extraction is investigated, to precisely measure the MC of Dutong pills. The principal components for low and high frequencies, are aimed at counteracting the dimensional methods, which are used for supplying the lower dimensional features. The SA experimental results demonstrate that the low frequency components, ranging from the base to the 3rd harmonic components, have a high linear correlation with the MC. The calibration and validation experimental results reveal that the MC can be a monotonic function about the SA amplitudes or first principal component (PC1), with the proposed sensor. This method has the potential to be used for gauging automatic, in situ MCs, particularly for quality control and Process Analytical Technology in TCM. Future research opportunities include improving accuracy and application of the method under field conditions.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Improved motional Stark effect signal processing using fast Fourier transform spectral analysis

A Fast Fourier Transform (FFT) based method has been developed, which improves the frequency response of the Motional Stark Effect (MSE) system by about a factor of 10 over the conventional analog lock-in method. The method uses fits to rigorously derived analytic expressions for the FFT spectral components of the MSE signal to accurately obtain the amplitudes and phases of the 2f1 and 2f2 photo-elastic modulator (PEM) frequencies that encode the polarization angle. Since no frequency filtering is used in the FFT method, the frequency response is limited by fundamental measurement properties: the frequency response of the detector, photon statistics, sample rate, and the ability to resolve the spectral components. In contrast, the frequency response of the analog lock-in is limited by a low pass filter with a cutoff of around 500 Hz. In the case of the DIII-D MSE system, the output of the photo-multiplier tube detector was sampled at 500 kHz and FFTs with as few as 100 points were used to obtain the amplitudes of the 2f1 and 2f2 PEM frequency components. This corresponds to a frequency response of 5 kHz, about ten times faster than the analog lock-in amplifier system. Details of the FFT method will be presented and compared to those of the analog lock-in system.

Makowski, M. A.↗

A versatile X-ray phase retarder for lock-in XMCD measurements

X-ray magnetic circular dichroism (XMCD) is a technique commonly used to probe magnetic properties of materials with element and orbital selectivity, which requires the use of circularly polarized (CP) X-rays. It is possible to accomplish XMCD experiments with fixed CP and alternating the magnetic field orientation, but most reliable data are obtained when alternating the magnetization orientation and the polarization between right and left helicities. A versatile strategy has been developed to perform XMCD experiments using a hard X-ray quarter-wave plate, at both polychromatic dispersive and conventional monochromatic optics, in combination with synchronous data acquisition. The switching frequency waveform is fed into a lock-in amplifier to detect and amplify the XMCD signal. The results on a reference sample demonstrate an improvement in data quality and acquisition time. The instrumentation successfully generated 98% of CP X-rays switching the beam helicity at 13 Hz, with the possibility of faster helicity switching once it is installed at the new Brazilian fourth-generation source, SIRIUS.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Deriving Material Properties from Feedback Error Signals in Scanning Tunneling Microscopy

Imperfections in measurements, e.g., deviations and broadening, are not devoid of information; rather, they can reveal valuable physical properties and processes. Scanning tunneling microscopy leverages a negative feedback loop to regulate the tunneling current. Practically, current fluctuates around its set point, and such deviations are considered insignificant and ignored. Here, in this study, we investigate the information embedded in these deviations. In the constant-current mode with an active feedback loop, we observe an unexpected persistent DC current offset from its set point when the tunneling junction is periodically perturbed. We demonstrate both experimentally and theoretically that such error signals encode local tunneling barrier heights and the square of local differential conductance as a consequence of the interplay between rectification and active feedback compensation. We provide evidence on the generalizability of this phenomenology to other negative feedback systems. This new approach has the potential to broadly impact physical sciences by allowing rapid measurements without lock-in amplifiers.

36 MATERIALS SCIENCE↗

Å-Indentation for non-destructive elastic moduli measurements of supported ultra-hard ultra-thin films and nanostructures

During conventional nanoindentation measurements, the indentation depths are usually larger than 1–10 nm, which hinders the ability to study ultra-thin films (<10 nm) and supported atomically thin two-dimensional (2D) materials. Here, we discuss the development of modulated Å-indentation to achieve sub-Å indentations depths during force-indentation measurements while also imaging materials with nanoscale resolution. Modulated nanoindentation (MoNI) was originally invented to measure the radial elasticity of multi-walled nanotubes. Now, by using extremely small amplitude oscillations (<<1 Å) at high frequency, and stiff cantilevers, we show how modulated nano/Å-indentation (MoNI/ÅI) enables non-destructive measurements of the contact stiffness and indentation modulus of ultra-thin ultra-stiff films, including CVD diamond films (~1000 GPa stiffness), as well as the transverse modulus of 2D materials. Our analysis demonstrates that in presence of a standard laboratory noise floor, the signal to noise ratio of MoNI/ÅI implemented with a commercial atomic force microscope (AFM) is such that a dynamic range of 80 dB –– achievable with commercial Lock-in amplifiers –– is sufficient to observe superior indentation curves, having indentation depths as small as 0.3 Å, resolution in indentation <0.05 Å, and in normal load <0.5 nN. Being implemented on a standard AFM, this method has the potential for a broad applicability.

36 MATERIALS SCIENCE↗

DR-RINS: Digital real-time relative intensity noise suppressor for pump–probe spectroscopy and microscopy

Relative intensity noise (RIN) inherent in fiber lasers poses a serious obstacle to their use in pump–probe spectroscopy and imaging. RIN can be removed through an analog balanced detector, or, as we have previously shown, software adaptive noise cancellation (ANC) on digitized signals. One major drawback to software ANC is the added time required for digitizing and post-processing. In this article, we describe a design for ANC on a field-programmable gate array (FPGA), making use of high-level synthesis tools and fixed-point arithmetic to achieve real-time laser RIN suppression at 25 MHz sample rates. Unlike the software-ANC approach, the FPGA-ANC device can serve as a dedicated drop-in denoiser, placed between the detectors and a commercial lock-in amplifier. We demonstrate its application to transient absorption spectroscopy and microscopy, lowering the noise floor to ~17 dB above the shot noise limit. Furthermore, we demonstrate a dramatic improvement in data acquisition time from ~6 h to ~5 min in a real-time imaging scenario.

47 OTHER INSTRUMENTATION↗

Piezoelectric property of PZT nanofibers characterized by resonant piezo-force microscopy

Nano-piezoelectric materials have drawn tremendous research interest. However, characterization of their piezoelectric properties, especially measuring the piezoelectric strain coefficients, remains a challenge. Normally, researchers use an AFM-based method to directly measure nano-materials’ piezoelectric strain coefficients. But, the extremely small piezoelectric deformation, the influence from the parasitic electrostatic force, and the environmental noise make the measurement results questionable. In this paper, a resonant piezo-force microscopy method was used to accurately measure the piezoelectric deformation from 1D piezoelectric nanofibers. During the experiment, the AFM tip was brought into contact with the piezoelectric sample and set to work at close to its first resonant frequency. A lock-in amplifier was used to pick up the sample’s deformation signal at the testing frequency. By using this technique, the piezoelectric strain constant d 33 of the Lead Zirconate Titanate (PZT) nanofiber with a diameter of 76 nm was measured. The result showed that d 33 of this PZT nanofiber was around 387 pm/V. Meanwhile, by tracking the piezoelectric deformation phase image, domain structures inside PZT nanofibers were identified.

36 MATERIALS SCIENCE↗

Electrical, optical, and magnetic properties of amorphous yttrium iron oxide thin films and consequences for non-local resistance measurements

We present magnetic characterization, charge resistivity, and optical photoluminescence measurements on amorphous yttrium iron oxide thin films ( ⁠a-Y–Fe–O), with supporting comparisons to amorphous germanium (⁠ a-Ge) films. We measured magnetic properties with both SQUID magnetometry and polarized neutron reflectometry. These results not only confirm that a-Y–Fe–O is a disordered magnetic material with strong predominantly antiferromagnetic exchange interactions and a high degree of frustration, but also that it is best understood electrically as a disordered semiconductor. As with amorphous germanium, a-Y–Fe–O obeys expectations for variable-range hopping through localized electron states over a wide range of temperature. We also clarify the consequences of charge transport through such a semiconducting medium for non-local voltage measurements intended to probe spin transport in nominally insulating magnetic materials. We further compare non-local resistance measurements made with “quasi-dc” automated current reversal to ac measurements made with a lock-in amplifier. These show that the “quasi-dc” measurement has an effective ac current excitation with frequency up to approximately 22 Hz, and that this effective ac excitation can cause artifacts in these measurements including incorrect sign of the non-local resistance. Here, this comprehensive investigation of non-local resistance measurements in a-Y–Fe–O shows no evidence of spin transport on micrometer length scales, which is contrary to our original work, and in line with more recent investigations by other groups.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Wavelength modulation laser-induced fluorescence for plasma characterization

Laser-Induced Fluorescence (LIF) spectroscopy is an essential tool for probing ion and atom velocity distribution functions (VDFs) in complex plasmas. VDFs carry information about the kinetic properties of species that is critical for plasma characterization. Accurate interpretation of these functions is challenging due to factors such as multicomponent distributions, broadening effects, and background emissions. Our research investigates the use of Wavelength Modulation (WM) LIF to enhance the sensitivity of VDF measurements. Unlike standard Amplitude Modulation (AM) methods, WM–LIF measures the derivative of the LIF signal. This approach makes variations in VDF shape more pronounced. VDF measurements with WM–LIF were investigated with both numerical modeling and experimental measurements. The developed model enables the generation of both WM and AM signals, facilitating comparative analysis of fitting outcomes. Experiments were conducted in a weakly collisional argon plasma with magnetized electrons and non-magnetized ions. Measurements of the argon ion VDFs employed a narrow-band tunable diode laser, which scanned the 4p 4 D 7/2 –3d 4 F 9/2 transition centered at 664.553 nm in vacuum. A lock-in amplifier detected the second harmonic WM signal, which was generated by modulating the laser wavelength with an externally controlled piezo-driven mirror of the diode laser. Finally, our findings indicate that the WM–LIF signal is more sensitive to fitting parameters, allowing for better identification of VDF parameters such as the number of distribution components, their temperatures, and velocities. In addition, WM–LIF can serve as an independent method to verify AM measurements and is particularly beneficial in environments with substantial light noise or background emissions, such as those involving thermionic cathodes and reflective surfaces.

47 OTHER INSTRUMENTATION↗

AC electrical transport detection of magnetic properties of small, granular, and heterogeneous samples

Experimental constraints and sample limitations can preclude ideal measurements of electrical transport properties of materials. In such situations, AC electrical transport methods are often employed due to a significant increase in signal-to-noise ratio they can provide. However, dynamic effects that are not often accounted for may be present that may modify the signals in these measurements. In particular, dynamic filtering effects are prominent in small, granular, and heterogeneous materials. We demonstrate that a lock-in amplifier based circuit can distinguish between these DC transport and AC filtering effects. Here, we further demonstrate that this filtering can reveal distinct signatures of magnetic transitions while providing a measure of sample quality.

47 OTHER INSTRUMENTATION↗

Light transport with weak angular dependence in fog

Random scattering and absorption of light by tiny particles in aerosols, like fog, reduce situational awareness and cause unacceptable down-time for critical systems or operations. Computationally efficient light transport models are desired for computational imaging to improve remote sensing capabilities in degraded optical environments. To this end, we have developed a model based on a weak angular dependence approximation to the Boltzmann or radiative transfer equation that appears to be applicable in both the moderate and highly scattering regimes, thereby covering the applicability domain of both the small angle and diffusion approximations. An analytic solution was derived and validated using experimental data acquired at the Sandia National Laboratory Fog Chamber facility. The evolution of the fog particle density and size distribution were measured and used to determine macroscopic absorption and scattering properties using Mie theory. A three-band (0.532, 1.55, and 9.68 µ m) transmissometer with lock-in amplifiers enabled changes in fog density of over an order of magnitude to be measured due to the increased transmission at higher wavelengths, covering both the moderate and highly scattering regimes. The meteorological optical range parameter is shown to be about 0.6 times the transport mean free path length, suggesting an improved physical interpretation of this parameter.

74 ATOMIC AND MOLECULAR PHYSICS↗

Synthesis and Characterization of Superconductor Diodes

In the era of modern computing, quantum bits (or qubits) are extensively researched due to their ability to perform computations exponentially faster than classical computers. One promising method for synthesizing qubits on a macroscopic scale is through superconductor diodes (SDs). Unfortunately, SDs are currently limited by their dependence on extremely low temperatures (T ≈ 0K), which restricts their practical usability at larger scales. To address this limitation, researchers are exploring new materials and methods to identify superconductors with higher critical temperatures. My research at the Lawrence Livermore National Laboratory (LLNL) focuses on synthesizing and characterizing superconductor diodes to determine their efficiency for quantum computing applications. Bismuth thin films were synthesized with magnetron sputtering with separate thicknesses which provides information on methods to alter their resistivity. Bismuth was characterized as the topological insulator used in the diode, and its resistivity was measured using a standard four-point probe technique with 1 mA current. Bismuth (99.99% pure) was then purified in a tubular furnace at 400C to use within a Josephson junction as a topological insulator. Niobium and Tantalum Josephson junctions were then synthesized, and they were characterized using a lock-in amplifier four-point probe technique. Materials such as niobium and tantalum are used in high-entropy alloy research, which is a relatively new class of material that has little research within the superconductor diode community, yet the current research shows promise. We anticipate that testing high-entropy superconductors will reveal crucial factors, potentially leading to the development of high-temperature superconductors in the future.

36 MATERIALS SCIENCE↗

A Python Instrument Control and Data Acquisition Suite for Reproducible Research

Tools that standardize and automate experimental data collection are needed for greater confidence in research results. The National Synchrotron Light Source-II (NSLS-II) has generated an open-source Python data acquisition, management, and analysis software suite that automates X-ray experiments and collects an experimental record that facilitates complete reproducibility. Here, we show that the NSLS-II tools are not only useful for X-ray science at large-scale facilities by presenting an add-on package that adapts these tools for use in a small laboratory with common physics and electrical engineering instruments. The composite software suite eases and automates the execution of experiments, records extensive metadata, stores data in portable containers, and speeds up the analysis through tools for comprehensive searches. In total, this software suite increases the reproducibility of laboratory experiments. We demonstrate the software via the evaluation of two lock-in amplifiers-the miniature ADA2200 and the ubiquitous Stanford Research Systems (SRS) SR810. The frequency resolution, signal-to-noise ratio, and dynamic reserve of the lock-in amplifiers are measured and presented. The usage of the software suite is described throughout these measurements so that the reader can implement the tools in their lab.

97 MATHEMATICS AND COMPUTING↗

In Situ Exploration of Dipole Field Effects on Weak Hysteresis in 3D/2D Perovskites

This research delves into the effects of 2D layers on the functionality of 3D perovskite using lock-in amplifier-based in situ surface photovoltage (SPV) and its phase spectroscopy, with an emphasis on elucidating the connection between the tuning of dipole moments and the photocurrent hysteresis. Conventionally, the SPV of a perovskite/hole transport layer is observed to diminish as positive bias escalates. However, this trend is reversed in the case of 3D perovskite samples, where an augmentation in SPV is noted under positive bias. Notably, 3D/2D perovskite structures initially show a decrease, then an increase in SPV as bias intensifies, a phenomenon more pronounced with larger dipole moments in 2D. However, there is no linear relationship between the dipole moment and the hysteresis factor. Furthermore, using in situ light-chopping-frequency-modulated SPV and Kelvin Probe Force Microscopy, it is revealed that the dipole fields of 2D layers can hinder ion migration. This leads to efficient hole transfer and minimal photocurrent hysteresis in 3D/2D perovskites, providing strong evidence for the underlying cause of hysteresis. Additionally, these findings suggest intricate interplays among the external electric field, interface dipole moments, and surface photovoltaics, offering significant insights into perovskite optoelectronics.

3D/2D perovskite↗

X-ray Beam Induced Current Measurements for Multi-Modal X-ray Microscopy of Solar Cells

X-ray beam induced current (XBIC) measurements allow mapping of the nanoscale performance of electronic devices such as solar cells. Ideally, XBIC is employed simultaneously with other techniques within a multi-modal X-ray microscopy approach. An example is given herein combining XBIC with X-ray fluorescence to enable point-by-point correlations of the electrical performance with chemical composition. For the highest signal-to-noise ratio in XBIC measurements, lock-in amplification plays a crucial role. By this approach, the X-ray beam is modulated by an optical chopper upstream of the sample. The modulated X-ray beam induced electrical signal is amplified and demodulated to the chopper frequency using a lock-in amplifier. By optimizing low-pass filter settings, modulation frequency, and amplification amplitudes, noise can efficiently be suppressed for the extraction of a clear XBIC signal. A similar setup can be used to measure the X-ray beam induced voltage (XBIV). Beyond standard XBIC/XBIV measurements, XBIC can be measured with bias light or bias voltage applied such that outdoor working conditions of solar cells can be reproduced during in-situ and operando measurements. Ultimately, the multi-modal and multi-dimensional evaluation of electronic devices at the nanoscale enables new insights into the complex dependencies between composition, structure, and performance, which is an important step towards solving the materials' paradigm.

14 SOLAR ENERGY↗

Feedback lock-in: A versatile multi-terminal measurement system for electrical transport devices

Here, we present the design and implementation of a measurement system that enables parallel drive and detection of small currents and voltages at numerous electrical contacts to a multi-terminal electrical device. This system, which we term a feedback lock-in, combines digital control-loop feedback with software-defined lock-in measurements to dynamically source currents and measure small, pre-amplified potentials. The effective input impedance of each current/voltage probe can be set via software, permitting any given contact to behave as an open-circuit voltage lead or as a virtually grounded current source/sink. This enables programmatic switching of measurement configurations and permits measurement of currents at multiple drain contacts without the use of current preamplifiers. Our 32-channel implementation relies on commercially available digital input/output boards, home-built voltage preamplifiers, and custom open-source software. With our feedback lock-in, we demonstrate differential measurement sensitivity comparable to a widely used commercially available lock-in amplifier and perform efficient multi-terminal electrical transport measurements on twisted bilayer graphene and SrTiO 3 quantum point contacts. The feedback lock-in also enables a new style of measurement using multiple current probes, which we demonstrate on a ballistic graphene device.

47 OTHER INSTRUMENTATION↗