Search NASA⌕ Search

SEARCH · Search NASA

Results for “LPTN model”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

Flow Assisted Evaporative Cooling for Electric Motor

This paper examines a novel concept of flow assisted latent heat driven two-phase evaporative cooling (EC) confined in-between slot liner and active-winding of electric motor. Wicking micro-structure enhanced PDMS liner axially sucks coolant in the form of thin film between the PDMS liner and active-winding and eventually enables thin film evaporation on the outer surface of the active-winding. Therefore, EC based thermal management eliminates contact resistance between the winding and slot-liner and, enhances the heat extraction from the winding without compromising the electro-magnetic performance. Two-way coupled electro-magnetic (EM) – computational fluid dynamics/heat transfer (CFD/HT) and EM - lumped parameter thermal network (LPTN) models have been developed to assess the electro-thermal performance of the EC under steady and transient conditions. Taking a case study of a 125 kW jacket cooled BMW i3 motor and dielectric coolant FC-84, EC is shown to be capable of handling a maximum steady state rms current density of 26 A/mm2 at a evaporative heat transfer coefficient of 5,000 W/m2.K, which is about 78.7% higher compared to the traditional jacket cooling (JC). In case of EC, a maximum steady state and transient rms current density of 30 A/mm2 (106.2% higher compared to the JC), and 40.8 A/mm2 have been realized by using high thermal conductivity epoxy (1.9 W/m.K) impregnation material. Thermal performance of the EC is also assessed and compared with JC over a dynamic drive cycle. Lastly, a motorette testing has been performed to demonstrate the applicability of the proposed EC method and to validate the developed modeling framework.

42 ENGINEERING↗

Validation and Parametric Investigations of an Internal Permanent Magnet Motor Using a Lumped Parameter Thermal Model

One of the key challenges for the electric vehicle industry is to develop high-power-density electric motors. Achieving higher power density requires efficient heat removal from inside the motor. In order to improve thermal management, a multiphysics modeling framework that is able to accurately predict the behavior of the motor, while being computationally efficient, is essential. This paper first presents a detailed validation of a lumped parameter thermal network (LPTN) model of an Internal Permanent Magnet synchronous motor within the commercially available MOTOR-CAD modeling environment. The validation is based on temperature comparison with experimental data and with more detailed finite element analysis (FEA). All critical input parameters of the LPTN are considered in detail for each layer of the stator, especially the contact resistances between the impregnation, liner, laminations, and housing. Finally, a sensitivity analysis for each of the critical input parameters is provided. A maximum difference of 4% - for the highest temperature in the slot-winding and the end-winding - was found between the LPTN and the experimental data. Comparing the results from the LPTN and the FEA model, the maximum difference was 2% for the highest temperature in the slot-winding and end-winding. As for the LPTN sensitivity analysis, the thermal parameter with the highest sensitivity was found to be the liner-to-lamination contact resistance.

42 ENGINEERING↗

Greybox Thermal Parameter Identification of Electric Machine Stators

The parameters of electric machine thermal equivalent circuit networks are difficult to predict due to material and manufacturing uncertainties. In this paper, a Greybox system identification approach is used to identify parameters of electric machine stator lumped parameter thermal networks (LPTNs). LPTNs provide a low order, computationally efficient, dynamic model of temperatures at specific locations. Second and third order LPTN model structures are defined as state space equations with stator thermal parameters to be identified. To test the Greybox electric machine stator thermal system identification, five stator motorette prototypes were constructed with controlled variations in slot fill and slot liner thickness. The variation in the motorette thermal parameters and thermal time constants are detected using the Greybox identification. Special attention is given to the impact of sampling rate and Greybox data record length on parameter estimation accuracy.

33 ADVANCED PROPULSION SYSTEMS↗

Validation and Parametric Investigations Using a Lumped Thermal Parameter Model of an Internal Permanent Magnet Motor

One of the key challenges for the electric vehicle industry is to develop high-power-density electric motors. Achieving higher power density requires efficient heat removal from inside the motor. In order to improve thermal management, a multi-physics modeling framework that is able to accurately predict the behavior of the motor, while being computationally efficient, is essential. This paper first presents a detailed validation of a Lumped Parameter Thermal Network (LPTN) model of an Internal Permanent Magnet (IPM) synchronous motor within the commercially available Motor-CAD® modeling environment. The IPM motor’s stator is studied at steady state, and winding losses are generated by a constant DC current. The validation is based on temperature comparison with experimental data and with more detailed Finite Element Analysis (FEA). All critical input parameters of the LPTN are considered in detail for each layer of the stator, especially the contact resistances between the impregnation, liner, laminations and housing. Finally, a sensitivity analysis for each of the critical input parameters is provided. A maximum difference of 4% — for the highest temperature in the slot windings and the end windings — was found between the LPTN and the experimental data. Comparing the results from the LPTN and the FEA model, the maximum difference was 2% for the highest temperature in the slot windings and end windings. As for the LTPN sensitivity analysis, the thermal parameter with the highest sensitivity was found to be the liner-to-lamination contact resistance. The latter is often ignored in the literature, whereas its impact on temperature rise was found to be more significant than any other contact resistance within the stator.

47 OTHER INSTRUMENTATION↗

Validation and Parametric Investigations Using a Lumped Thermal Parameter Model of an Internal Permanent Magnet Motor: Preprint

One of the key challenges for the electric vehicle industry is to develop high-power-density electric motors. Achieving higher power density requires efficient heat removal from inside the motor. In order to improve thermal management, a multi-physics modeling framework that is able to accurately predict the behavior of the motor, while being computationally efficient, is essential. This paper first presents a detailed validation of a Lumped Parameter Thermal Network (LPTN) model of an Internal Permanent Magnet (IPM) synchronous motor within the commercially available Motor-CAD® modeling environment. The IPM motor’s stator is studied at steady state, and winding losses are generated by a constant DC current. The validation is based on temperature comparison with experimental data and with more detailed Finite Element Analysis (FEA). All critical input parameters of the LPTN are considered in detail for each layer of the stator, especially the contact resistances between the impregnation, liner, laminations and housing. Finally, a sensitivity analysis for each of the critical input parameters is provided. A maximum difference of 4% - for the highest temperature in the slot windings and the end windings - was found between the LPTN and the experimental data. Comparing the results from the LPTN and the FEA model, the maximum difference was 2% for the highest temperature in the slot windings and end windings. As for the LTPN sensitivity analysis, the thermal parameter with the highest sensitivity was found to be the liner-to-lamination contact resistance. The latter is often ignored in the literature, whereas its impact on temperature rise was found to be more significant than any other contact resistance within the stator.

ADVANCED PROPULSION SYSTEMS↗