Search NASA⌕ Search

SEARCH · Search NASA

Results for “LSO”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Spectroscopic refractive indices of monoclinic single crystal and ceramic Lutetium oxyorthosilicate (LSO) from 200 to 850 nm

The four real values of the dielectric function tensor of the monoclinic crystal Lu2SiO5 or lutetium oxyorthosilicate (LSO) have been determined using generalized ellipsometry from 200 to 850 nm. The three principal values are fit to the Sellmeier model, and they indicate that the band gap of LSO is less than ~9 eV. The off-diagonal element 12 is non-zero over the entire spectrum, but it is very close to zero for wavelengths longer than ~400 nm, indicating that structurally monoclinic LSO is nearly optically orthorhombic in this wavelength region. The spectroscopic dielectric functions of three isotropic ceramic LSO samples are presented, which are consistent with the dielectric functions of single-crystal LSO when the effects of porosity are included. As a comparison, the dielectric functions are also determined using relativistic electronic structure and optical calculations based on the recently developed potential functional of Tran and Blaha (Phys. Rev. Lett. 102, 226401 (2009).)

Jellison, Jr, Gerald Earle↗

Growth and characterization of new semiorganic nonlinear optical and piezoelectric lithium sulfate monohydrate oxalate single crystals

Highlights: • A new semiorganic single crystal of LSO grown by slow evaporation technique. • Morphological studies of the LSO crystal deduced by BFDH law. • In the UV–vis spectrum wide transparent region and large band gap were found. • SHG is equal to KDP crystal and d{sub 33} was found to be equal to 6pC/N. • Grown crystal belongs to softer category. - Abstract: New semiorganic crystal of lithium sulfate monohydrate oxalate (LSO) for nonlinear application was synthesized by controlled slow evaporation method. The growth rate of various planes of the grown crystal was estimated by morphological study. Single crystal XRD analysis confirmed that the crystal belongs to triclinic lattice with space group P1. High transparency (∼95%) with large band gap (4.57 eV) was analyzed by UV–vis studies. FTIR and Raman spectroscopy were used to identify various functional groups present in the LSO crystal. SHG efficiency was found to be equal to the KDP crystal. Thermal stability (up to 117.54 °C) and melting point (242 °C) of the crystal were studied by TG-DTA. In dielectric measurements, the value of dielectric constant decreases with increase in frequency. Hardness studies confirmed soft nature of crystals. The piezoelectric coefficient was found to be 6pC/N along [0 0 1].

36 MATERIALS SCIENCE↗

Effects of reflector and crystal surface on the performance of a depth-encoding PET detector with dual-ended readout

Purpose: Depth encoding detectors are required to improve the spatial resolution and spatial resolution uniformity of small animal positron emission tomography (PET) scanners, as well as dedicated breast and brain scanners. Depth of interaction (DOI) can be measured by using dual-ended readout of lutetium oxyorthosilicate (LSO) scintillator arrays with position-sensitive avalanche photodiodes. Inter-crystal reflectors and crystal surface treatments play important roles in determining the performance of dual-ended detectors. In this paper, the authors evaluated five LSO arrays made with three different intercrystal reflectors and with either polished or unpolished crystal surfaces. Methods: The crystal size in all arrays was 1.5 mm, which is typical of the detector size used in small animal and dedicated breast scanners. The LSO arrays were measured with dual-ended readout and were compared in terms of flood histogram, energy resolution, and DOI resolution performance. Results: The four arrays using enhanced specular reflector (ESR) and Toray reflector provided similar quality flood histograms and the array using Crystal Wrap reflector gave the worst flood histogram. The two arrays using ESR reflector provided the best energy resolution and the array using Crystal Wrap reflector yielded the worst energy resolution. All arrays except the polished ESR array provided good DOI resolution ranging from 1.9 mm to 2.9 mm. DOI resolution improved as the gradient in light collection efficiency with depth (GLCED) increased. The geometric mean energies were also calculated for these dual-ended readout detectors as an alternative to the conventional summed total energy. It was shown that the geometric mean energy is advantageous in that it provides more uniform photopeak amplitude at different depths for arrays with high GLCED, and is beneficial in event selection by allowing a fixed energy window independent of depth. A new method of DOI calculation that improved the linearity of DOI ratio vs depth and simplifies the DOI calibration procedure also was developed and tested. Conclusions: The results of these studies provide useful guidance in selecting the proper reflectors and crystal surface treatments when LSO arrays are used for high-resolution PET applications in small animal scanners or dedicated breast and brain scanners.

60 APPLIED LIFE SCIENCES↗

An Investigation of X-ray Luminosity versus Crystalline Powder Granularity

At the High-throughput Discovery of Scintillator Materials Facility at Lawrence Berkeley National Laboratory, scintillators are synthesized by solid-state reaction or melt mixing, forming crystalline powders. These powders are formed in various granularity and the crystal grain size affects the apparent luminosity of the scintillator. To accurately predict a "full-size" scintillator's crystal luminosity, the crystal luminosity as a function of crystal granularity size has to be known. In this study, we examine Bi{sub 4}Ge{sub 3}O{sub 12} (BGO), Lu{sub 2}SiO{sub 5}:Ce (LSO), YAlO{sub 3}:Ce (YAP:Ce), and CsBa{sub 2}I{sub 5}:Eu{sup 2+} (CBI) luminosities as a function of crystalline grain size. The highest luminosities were measured for 600- to 1000-{micro}m crystal grain sizes for BGO and LSO, for 310- to 600-{micro}m crystal grain sizes for CBI, and for crystal grains larger than 165{micro}m for YAP:Ce. Crystal grains that were larger than 1 mm had a lower packing fraction, and smaller grains were affected by internal scattering. We measured a 34% decrease in luminosity for BGO when decreasing from the 600- to 1000- {micro}m crystal grain size range down to the 20- to 36-{micro}m range. The corresponding luminosity decrease for LSO was 44% for the same grain size decrease. YAP:Ce exhibited a luminosity decrease of 47% when the grain size decreased from the 165- to 310-{micro}m crystal grains to the 20- to 36-{micro}m range, and CBI exhibited a luminosity decrease of 98% when the grain size decreased from the 310- to 600-{micro}m crystal grain range to the 36- to 50-{micro}m range. We were able to very accurately estimate full-size crystal luminosities from crystalline grains that are larger than 90 {micro}m.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Monte Carlo calculations of PET coincidence timing: single and double-ended readout

We present Monte Carlo computational methods for estimating the coincidence resolving time (CRT) of scintillator detector pairs in positron emission tomography (PET) and present results for Lu 2 SiO 5 : Ce (LSO), LaBr 3 : Ce, and a hypothetical ultra-fast scintillator with a 1 ns decay time. The calculations were applied to both single-ended and double-ended photodetector readout with constant-fraction triggering. They explicitly include (1) the intrinsic scintillator properties (luminosity, rise time, decay time, and index of refraction), (2) the exponentially distributed depths of interaction, (3) the optical photon transport efficiency, delay, and time dispersion, (4) the photodetector properties (fill factor, quantum efficiency, transit time jitter, and single electron response), and (5) the determination of the constant fraction trigger level that minimizes the CRT. The calculations for single-ended readout include the delayed photons from the opposite reflective surface. The calculations for double-ended readout include (1) the simple average of the two photodetector trigger times, (2) more accurate estimators of the annihilation photon entrance time using the pulse height ratio to estimate the depth of interaction and correct for annihilation photon, optical photon, and trigger delays, and (3) the statistical lower bound for interactions at the center of the crystal. For time-of-flight (TOF) PET we combine stopping power and TOF information in a figure of merit equal to the sensitivity gain relative to whole-body non-TOF PET using LSO. For LSO crystals 3 mm × 3 mm × 30 mm, a decay time of 37 ns, a total photoelectron count of 4000, and a photodetector with 0.2 ns full-width at half-maximum (fwhm) timing jitter, single-ended readout has a CRT of 0.16 ns fwhm and double-ended readout has a CRT of 0.111 ns fwhm. For LaBr 3 : Ce crystals 3 mm × 3 mm × 30 mm, a rise time of 0.2 ns, a decay time of 18 ns, and a total of 7600 photoelectrons the CRT numbers are 0.14 ns and 0.072 ns fwhm, respectively. For a hypothetical ultra-fast scintillator 3 mm × 3 mm × 30 mm, a decay time of 1 ns, and a total of 4000 photoelectrons, the CRT numbers are 0.070 and 0.020 ns fwhm, respectively. Over a range of examples, values for double-ended readout are about 10% larger than the statistical lower bound.

Monte Carlo↗

General-Surrogate Adaptive Sampling Using Interquartile Range for Design Space Exploration

Abstract A surrogate model is a common tool to approximate system response at untested points for design space exploration. Adaptive sampling has been studied for improving the accuracy of surrogates iteratively by introducing additional samples (simulations and experiments). New samples are often selected based on the estimated uncertainty in the design space. While some surrogates such as kriging have readily available uncertainty models for their predictions, other surrogates do not. Consequently, there have been studies of using the process of leaving-samples-out (LSO) used in cross-validation tools to estimate prediction uncertainty, such as the universal prediction distribution (UPD). In this paper, an adaptive sampling scheme for general surrogates is proposed based on LSO, similar to cross-validation and interquartile range (IQR). Multiple submodels are first developed from LSO. The uncertainty is then estimated from the IQR of these surrogates at a given point. New samples are added iteratively at the point with maximum IQR for design space exploration. The proposed scheme is illustrated using kriging, radial basis function, and neural network surrogates. The proposed scheme is evaluated using four algebraic test functions. Multiple sets of initial samples were produced to account for randomness. For these test functions, the proposed scheme was found to be more accurate and robust than kriging with its own uncertainty model. The proposed scheme was more accurate than the UPD for three out of the four test functions. For a fixed number of samples, the IQR-based adaptive sampling also proved to be more accurate than all-at-once sampling in most cases even when the estimated uncertainty was only mildly correlated with prediction errors.

Engineering↗

Reflector coatings development (FY2020 End of Year Report)

X-ray detection instrumentation has been developed and manufactured at LANL for various DOE programs. One way to improve light collection efficiency, for a scintillator type detector, is to apply suitable reflectors. The coating capability and fabrication procedure for Al reflective coatings was established in FY19 at MST-7. Al reflective coatings with good stability, good adhesion to LSO, and reflectivity (R) up to 78% were fabricated. Materials with higher diffuse reflectivity (such as Teflon tape R=99%) are desirable. A literature search revealed a number of materials in the form of paint or free standing tape with diffuse R = 98- 99%. However, for the intended application such reflectors have to be applied in the form of a coating with strong adhesion to LSO crystals. The purpose of the FY20 project was to develop thin film coating techniques for PTFE (known as Teflon) reflectors and fabricate reflective coatings on provided LSO crystals.

36 MATERIALS SCIENCE↗

Detection of high energy muons with sub-20 ps timing resolution using L(Y)SO crystals and SiPM readout

Precise timing capability will be a key aspect of particle detectors at future high energy colliders, as the time information can help in the reconstruction of physics events at the high collision rate expected there. Other than being used in detectors for PET, fast scintillating crystals coupled to compact Silicon Photomultipliers (SiPMs) constitute a versatile system that can be exploited to realize an ad-hoc timing device to be hosted in a larger high energy physics detector. In this paper, we present the timing performance of LYSO:Ce and LSO:Ce codoped 0.4% Ca crystals coupled to SiPMs, as measured with 150 GeV muons at the CERN SPS H2 extraction line. Small crystals, with lengths ranging from 5 mm up to 30 mm and transverse size of 2×2mm 2 or 3×3mm 2 , were exposed to a 150 GeV muon beam. SiPMs from two different companies (Hamamatsu and FBK) were used to detect the light produced in the crystals. The best coincidence time resolution value of (14.5±0.5)ps , corresponding to a single-detector time resolution of about 10 ps, is demonstrated for 5 mm long LSO:Ce,Ca crystals coupled to FBK SiPMs, when time walk corrections are applied.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Glutamate co-transmission from developing medial nucleus of the trapezoid body - Lateral superior olive synapses is cochlear dependent in kanamycin-treated rats

Research highlights: {yields} Glutamate co-transmission is enhanced in kanamycin-treated rats. {yields} VGLUT3 expression is increased in kanamycin-treated rats. {yields} GlyR expression is decreased in kanamycin-treated rats. {yields} GlyR, VGLUT3 expression patterns are asymmetric in unilaterally cochlear ablated rat. -- Abstract: Cochlear dependency of glutamate co-transmission at the medial nucleus of the trapezoid body (MNTB) - the lateral superior olive (LSO) synapses was investigated using developing rats treated with high dose kanamycin. Rats were treated with kanamycin from postnatal day (P) 3 to P8. A scanning electron microscopic study on P9 demonstrated partial cochlear hair cell damage. A whole cell voltage clamp experiment demonstrated the increased glutamatergic portion of postsynaptic currents (PSCs) elicited by MNTB stimulation in P9-P11 kanamycin-treated rats. The enhanced VGLUT3 immunoreactivities (IRs) in kanamycin-treated rats and asymmetric VGLUT3 IRs in the LSO of unilaterally cochlear ablated rats supported the electrophysiologic data. Taken together, it is concluded that glutamate co-transmission is cochlear-dependent and enhanced glutamate co-transmission in kanamycin-treated rats is induced by partial cochlear damage.

60 APPLIED LIFE SCIENCES↗

Constructing stable interface layer for boosting high-voltage cycling performance of single-crystal Ni-rich cathodes

Increasing demand for electric vehicles (EVs) worldwide and the requirements for environmental protection have greatly promoted the development of low-Co, Ni-rich layered cathodes due to their high energy density, reasonable cost, and less environmental pollution. Nevertheless, serious performance degradation and safety concerns resulting from structural/interfacial instability under high operating voltages (≥4.3 V) have greatly hindered its commercialization. Herein, we propose a feasible surface modification strategy by introducing a multifunctional Li 2 SiO 3 (LSO) coating layer onto the surface of Co less single-crystalline LiNi 0.63 Co 0.07 Mn 0.3 O 2 (NCM) to solve the above challenges. Additionally, the uniform Li 2 SiO 3 coating layer has a unique three-dimensional (3D) ion diffusion channel, which greatly promotes the transmission of Li + and alleviates interfacial stress accumulation. Equally important, the electrochemically inert Li 2 SiO 3 coating layer has a stable structure framework with strong Si-O bonds, which inhibit anisotropic particle volume expansion and the occurrence of side reactions during long-term cycling. As a consequence, LSO modified NCM exhibits greatly improved electrochemical properties even at harsh testing conditions and achieves capacity retention of 79.1% after 200 cycles at 25°C within 2.95-4.5 V in half cells. Furthermore, it provides an outstanding capacity retention of 94.7% after 300 cycles at 25°C within 2.95-4.4 V when tested in pouch full cells.

25 ENERGY STORAGE↗

Growth conditions, structure, Raman characterization and optical properties of Sm-doped (Lu{sub x}Gd{sub 1-x}){sub 2}SiO{sub 5} single crystals grown by the Czochralski method

The (Lu{sub x}Gd{sub 0.995-x}Sm{sub 0.005}){sub 2}SiO{sub 5} single crystals with x=0.095, 0.11, 0.15, 0.17, 0.19 0.35 and 0.5 were grown by the Czochralski method. Structural properties were investigated by X-ray diffraction measurements. Unit cell parameters and cell volume were determined by the Rietveld refinement of the collected X-ray powder spectra. The segregation features between Gd and Lu were estimated and analyzed. Vibrational properties of the solid solutions were analyzed on the basis of polarized Raman spectra acquired at 300-875 K temperature range. Absorption and emission spectra of Sm{sup 3+} ion in the crystals with different composition were analyzed in the terms of dopant energy levels, oscillator strengths of transitions and spectral features of luminescence bands in the visible range. Both structural and optical investigations revealed that change of Lu{sup 3+} content in (Lu{sub x}Gd{sub 0.995-x}Sm{sub 0.005}){sub 2}SiO{sub 5} solid solution crystals induces the phase transition from C2/c (Lu{sub 2}SiO{sub 5}) to P2{sub 1}/c (Gd{sub 2}SiO{sub 5}) structure. It was found that the break of LSO to GSO-type structure occurs at 0.15<x<0.17. - Graphical abstract: Single crystals of Sm{sup 3+}-doped (Lu{sub x}Gd{sub 1-x}){sub 2}SiO{sub 5} solid solutions have been grown by Czochralski method and characterized by various techniques. Crystal structure changes from C2/c to P2{sub 1}/c for composition with 0.15<x<0.17. Change of crystal structure causes changes in emission spectra. Highlights: Black-Right-Pointing-Pointer The (Lu{sub x}Gd{sub 1-x}){sub 2}SiO{sub 5} crystals are an alternative to LSO and GSO hosts for applications. Black-Right-Pointing-Pointer The break of the P2{sub 1}/c to C2/c structure in (Lu{sub x}Gd{sub 1-x}){sub 2}SiO{sub 5}:Sm occurs for 0.15<x<0.17. Black-Right-Pointing-Pointer Temperature-induced phase transition from C2/c to P2{sub 1}/c up to 875 K was not observed. Black-Right-Pointing-Pointer Observed significant changes of emission spectra caused by P2{sub 1}/c to C2/c structural transition.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

LONG-TERM EVOLUTION OF SLOWLY ROTATING COLLAPSAR IN SPECIAL RELATIVISTIC MAGNETOHYDRODYNAMICS

We present our numerical results of two-dimensional magnetohydrodynamic (MHD) simulations of the collapse of rotating massive stars in light of the collapsar model of gamma-ray bursts (GRBs). Pushed by recent evolution calculations of GRB progenitors, we focus on lower angular momentum of the central core than those taken mostly in previous studies. By performing special relativistic simulations including both realistic equation of state and neutrino cooling, we follow a long-term evolution of the slowly rotating collapsars up to approx10 s, accompanied by the formation of jets and accretion disks. Our results show that for the GRB progenitors to function as collapsars, there is a critical initial angular momentum, below which matter is quickly swallowed to the central objects, no accretion disks and no MHD outflows are formed. When larger than the criteria, we find the launch of the MHD jets in the following two ways. For models with stronger initial magnetic fields, the magnetic pressure amplified inside the accretion disk can drive the MHD outflows, which makes the strong magnetic explosions like a 'magnetic tower'. For models with weaker initial magnetic fields, the magnetic tower stalls first and the subsequent MHD outflows are produced by the magnetic twisting of the turbulent inflows of the accreting material from the equatorial to the polar regions. Regardless of the difference in the formation, the jets can attain only mildly relativistic speeds with the explosion energy less than 10{sup 49} erg. To obtain stronger neutrino energy depositions in the polar funnel regions heated from the accretion disk, we find that smaller initial angular momentum is favorable. This is because the gravitational compression makes the temperature of the disk higher. Due to high neutrino opacity inside the disk, we find that the luminosities of nu {sub e} and nu-bar {sub e} become almost comparable, which is advantageous for making the energy deposition rate larger. We discuss how the energy deposition can be as efficient as the magnetically driven processes for energetizing jets. Among the computed models, we suggest that the model with the initial angular momentum of j approx 1.5j {sub lso} (j {sub lso}: the angular momentum of the last stable orbit) and with initial magnetic field strength of approx10{sup 10} G, provides a most plausible condition for making fireballs for GRBs, because such model is appropriate not only for producing the MHD outflows quickly by the magnetic towers, but also for obtaining the stronger neutrino heating in the evacuated polar funnel.

79 ASTRONOMY AND ASTROPHYSICS↗

Monte Carlo simulations of time-of-flight PET with double-ended readout: calibration, coincidence resolving times and statistical lower bounds

Here, this paper demonstrates through Monte Carlo simulations that a practical positron emission tomograph with (1) deep scintillators for efficient detection, (2) double-ended readout for depth-of-interaction information, (3) fixed-level analog triggering, and (4) accurate calibration and timing data corrections can achieve a coincidence resolving time (CRT) that is not far above the statistical lower bound. One Monte Carlo algorithm simulates a calibration procedure that uses data from a positron point source. Annihilation events with an interaction near the entrance surface of one scintillator are selected, and data from the two photodetectors on the other scintillator provide depth-dependent timing corrections. Another Monte Carlo algorithm simulates normal operation using these corrections and determines the CRT. A third Monte Carlo algorithm determines the CRT statistical lower bound by generating a series of random interaction depths, and for each interaction a set of random photoelectron times for each of the two photodetectors. The most likely interaction times are determined by shifting the depth-dependent probability density function to maximize the joint likelihood for all the photoelectron times in each set. Example calculations are tabulated for different numbers of photoelectrons and photodetector time jitters for three 3 × 3 × 30 mm 3 scintillators: Lu 2 SiO 5 :Ce,Ca (LSO), LaBr 3 :Ce, and a hypothetical ultra-fast scintillator. To isolate the factors that depend on the scintillator length and the ability to estimate the DOI, CRT values are tabulated for perfect scintillator-photodetectors. For LSO with 4000 photoelectrons and single photoelectron time jitter of the photodetector J = 0.2 ns (FWHM), the CRT value using the statistically weighted average of corrected trigger times is 0.098 ns FWHM and the statistical lower bound is 0.091 ns FWHM. For LaBr 3 :Ce with 8000 photoelectrons and J = 0.2 ns FWHM, the CRT values are 0.070 and 0.063 ns FWHM, respectively. For the ultra-fast scintillator with 1 ns decay time, 4000 photoelectrons, and J = 0.2 ns FWHM, the CRT values are 0.021 and 0.017 ns FWHM, respectively. Lastly, the examples also show that calibration and correction for depth-dependent variations in pulse height and in annihilation and optical photon transit times are necessary to achieve these CRT values.

60 APPLIED LIFE SCIENCES↗

Performance of the Tachyon Time-of-Flight PET Camera

We have constructed and characterized a time-of-flight Positron Emission Tomography (TOF PET) camera called the Tachyon. The Tachyon is a single-ring Lutetium Oxyorthosilicate (LSO) based camera designed to obtain significantly better timing resolution than the ~ 550 ps found in present commercial TOF cameras, in order to quantify the benefit of improved TOF resolution for clinically relevant tasks. The Tachyon's detector module is optimized for timing by coupling the 6.15 ×25 mm 2 side of 6.15 ×6.15 ×25 mm 3 LSO scintillator crystals onto a 1-inch diameter Hamamatsu R-9800 PMT with a super-bialkali photocathode. We characterized the camera according to the NEMA NU 2-2012 standard, measuring the energy resolution, timing resolution, spatial resolution, noise equivalent count rates and sensitivity. The Tachyon achieved a coincidence timing resolution of 314 ps +/- 20 ps FWHM over all crystal-crystal combinations. Experiments were performed with the NEMA body phantom to assess the imaging performance improvement over non-TOF PET. We find that the results show that at a matched contrast, incorporating 314 ps TOF reduces the standard deviation of the contrast by a factor of about 2.3.

47 OTHER INSTRUMENTATION↗

Investigating the limits of PET/CT imaging at very low true count rates and high random fractions in ion-beam therapy monitoring

Purpose: External beam radiotherapy with protons and heavier ions enables a tighter conformation of the applied dose to arbitrarily shaped tumor volumes with respect to photons, but is more sensitive to uncertainties in the radiotherapeutic treatment chain. Consequently, an independent verification of the applied treatment is highly desirable. For this purpose, the irradiation-induced β{sup +}-emitter distribution within the patient is detected shortly after irradiation by a commercial full-ring positron emission tomography/x-ray computed tomography (PET/CT) scanner installed next to the treatment rooms at the Heidelberg Ion-Beam Therapy Center (HIT). A major challenge to this approach is posed by the small number of detected coincidences. This contribution aims at characterizing the performance of the used PET/CT device and identifying the best-performing reconstruction algorithm under the particular statistical conditions of PET-based treatment monitoring. Moreover, this study addresses the impact of radiation background from the intrinsically radioactive lutetium-oxyorthosilicate (LSO)-based detectors at low counts. Methods: The authors have acquired 30 subsequent PET scans of a cylindrical phantom emulating a patientlike activity pattern and spanning the entire patient counting regime in terms of true coincidences and random fractions (RFs). Accuracy and precision of activity quantification, image noise, and geometrical fidelity of the scanner have been investigated for various reconstruction algorithms and settings in order to identify a practical, well-suited reconstruction scheme for PET-based treatment verification. Truncated listmode data have been utilized for separating the effects of small true count numbers and high RFs on the reconstructed images. A corresponding simulation study enabled extending the results to an even wider range of counting statistics and to additionally investigate the impact of scatter coincidences. Eventually, the recommended reconstruction scheme has been applied to exemplary postirradiation patient data-sets. Results: Among the investigated reconstruction options, the overall best results in terms of image noise, activity quantification, and accurate geometrical recovery were achieved using the ordered subset expectation maximization reconstruction algorithm with time-of-flight (TOF) and point-spread function (PSF) information. For this algorithm, reasonably accurate (better than 5%) and precise (uncertainty of the mean activity below 10%) imaging can be provided down to 80 000 true coincidences at 96% RF. Image noise and geometrical fidelity are generally improved for fewer iterations. The main limitation for PET-based treatment monitoring has been identified in the small number of true coincidences, rather than the high intrinsic random background. Application of the optimized reconstruction scheme to patient data-sets results in a 25% − 50% reduced image noise at a comparable activity quantification accuracy and an improved geometrical performance with respect to the formerly used reconstruction scheme at HIT, adopted from nuclear medicine applications. Conclusions: Under the poor statistical conditions in PET-based treatment monitoring, improved results can be achieved by considering PSF and TOF information during image reconstruction and by applying less iterations than in conventional nuclear medicine imaging. Geometrical fidelity and image noise are mainly limited by the low number of true coincidences, not the high LSO-related random background. The retrieved results might also impact other emerging PET applications at low counting statistics.

60 APPLIED LIFE SCIENCES↗

WE-EF-303-03: A New Aperture-Based Imaging System for Prompt-Gamma Range Verification of Proton Beam Therapy

Purpose: To develop and characterize a novel aperture-based imaging system for high-energy gamma-rays. This collimated system will provide 2-dimensional imaging capability for verification of proton beam range and Bragg peak dose via prompt-gamma detection. Methods: A multi-knife-edge slit collimator has been designed, constructed, and characterized via simulations and experimental measurements. The 20×20×7.5 cm{sup 3} tungsten collimator and accompanying LSO scintillation detector were simulated using the TOPAS Geant4 -based Monte Carlo package. Iterative reconstruction methods were combined with point response functions to characterize the imaging performance of the system. The response of the system has begun to be characterized experimentally as well, using 2.6 MeV gamma-rays from Th-228. Results: Both simulation and experimental results indicate that this collimated system provides 2-D imaging capability in the energy range of interest for prompt-gamma dose verification. In the current configuration, with collimator to source distance of 13 cm, image reconstruction of point sources resulted in spatial resolution (FWHM) of approximately 4 mm in both x-and y-directions in the imaging plane. The accuracy of positioning the point sources is less than 1 mm. Conclusion: This work has characterized, via simulation and measurements, a novel multi-knife-edge slit collimator in front of a more conventional position-sensitive LSO scintillator detector. The multi-slit pattern is designed to increase detection efficiency and provide spatial information in 2-dimensions -- an improvement over a single-slit collimator design. The thickness and density of the collimator will allow this detection system to perform well in an environment with high gamma flux, while ultimately providing peak determination accuracy on the order of 1 mm. This material is based upon work supported by the Department of Energy National Nuclear Security Administration under Award Number: DE-NA0000979 through the Nuclear Science and Security Consortium.

60 APPLIED LIFE SCIENCES↗

Sci-Fri PM: Radiation Therapy, Planning, Imaging, and Special Techniques - 01: On the use of proton radiography to reduce beam range uncertainties and improve patient positioning accuracy in proton therapy

To present two related developments of proton radiography (pRad) to minimize range uncertainty in proton therapy. The first combines a pRad with an X-ray CT to produce a patient-specific relative stopping power (RSP) map. The second aims to improve the pRad spatial resolution for accurate registration prior to the first. The enhanced-pRad can also be used in a novel proton-CT reconstruction algorithm. Monte Carlo pRad were computed from three phantoms; the Gammex, the Catphan and an anthropomorphic head. An optimized cubic-spline estimator derives the most likely path. The length crossed by the protons voxel-by-voxel was calculated by combining their estimated paths with the CT. The difference between the theoretical (length×RSP) and measured energy loss was minimized through a least squares optimization (LSO) algorithm yielding the RSP map. To increase pRad spatial resolution for registration with the CT, the phantom was discretized into voxels columns. The average column RSP was optimized to maximize the proton energy loss likelihood (MLE). Simulations showed precise RSP (<0.75%) for Gammex materials except low-density lung (<1.2%). For the head, accurate RSP were obtained (µ=−0.10%1.5σ=1.12%) and the range precision was improved (ΔR80 of −0.20±0.35%). Spatial resolution was increased in pRad (2.75 to 6.71 lp/cm) and pCT from MLE-enhanced pRad (2.83 to 5.86 lp/cm). The LSO decreases the range uncertainty (R80σ<1.0%) while the MLE-enhanced pRad spatial resolution (+244%) and is a great candidate for pCT reconstruction.

60 APPLIED LIFE SCIENCES↗