The Low-Yield Nuclear Monitoring (LYNM) Experimental Science Plan

The Low-Yield Nuclear Monitoring (LYNM) Program is a long-term NNSA research and development effort designed to improve the United States’ explosion monitoring capabilities, particularly with respect to low-yield and potentially evasive underground nuclear testing. The LYNM Program focuses on researching, discovering, and exploiting unique and useful signatures, from all available technologies and sensors (e.g., seismic, acoustic, electromagnetic, gases, and particulates (both stable and radioactive)). Four Department of Energy laboratories participate in LYNM and together are referred to as the ‘quad-lab’. The R&D program execution is performed under NNSA defined structures known as “ventures”. Four science ventures were established: 1) Explosion Source Functions; 2) Containment of Low-Yield Underground Tests; 3) Local Signatures; 4) Dynamic Monitoring Networks. To organize and execute the large field scale experiment a fifth venture was established: 5) Physics Experiment One (PE-1). As part of the LYNM Program, a series of experiments are planned at various scales and levels of venture involvement. These vary from those that involve a subset of labs and/or LYNM ventures (e.g., small experiments), to full quad-lab LYNM Program field-scale integrated experiments. Such experiments may involve chemical explosions with tracer materials or other means of simulating the expected signals from a nuclear explosion. The LYNM Program does not conduct actual nuclear explosions. Since 1992, the U.S. has observed a moratorium on underground nuclear explosions. This document is intended to provide the underlying scientific basis for the LYNM planned experimental work. Each specific LYNM experiment will develop a goals, objectives, and requirements (GOR) plan following the guidance in this document. The LYNM technical staff will define the numbers and types of experiments required over the course of the Program based on technical needs and within funding constraints. As with any scientific experiment series, the number and types of experiments may change based upon the experimental results obtained. An experiment that agrees with models/codes/software signature predictions may need fewer repetitions/variations, depending upon the level of statistical rigor desired, as compared to one in which the predictions and experimental data do not match. The large LYNM field-scale integrated experiments require the longest lead-time for planning, and these are discussed in more detail near the end of this document.

58 GEOSCIENCES↗

A flow-through gamma detection system for sub-surface radioxenon tracer measurements in LYNM PE1

A continuous flow-through, real-time radioxenon sensor array has been designed to monitor either 127 Xe or 133 Xe tracer gas as part of a series of underground chemical explosions in the Low-Yield Nuclear Monitoring (LYNM) Physics Experiment 1 (PE1). The sensors are pairs of shielded thallium-doped sodium iodide gamma-ray detectors that surround a gas measurement chamber. Each measurement chamber is connected to a sampling location in the geology surrounding the chemical explosion or in the access tunnel. The first experiment in the series, PE1 A, occurred in 2023 and the system quantified the 127 Xe tracer gas in the gas sampling lines for four weeks following the experiment execution. The array generated a set of radioxenon concentration time series with a 15-minute resolution that will be used to refine subsurface gas transport models.

Gamma-ray coincidence detection↗

LYNM PE1 Pre-Experiment A Site Characterization Report

Underground chemical explosive experiments such as LYNM PE1 generate large multiphenomenological datasets, require complex site preparation and build out, and utilize cutting edge models and analysis techniques to analyze and simulate the explosion-induced signals. This wide range of outcomes makes it a necessity to thoroughly characterize the testbed in advance of experiments in a way that complements the wide suite of data being generated. Here, we present a broad overview of the site characterization work and data collection that was conducted before Experiment A, which is the first in a series of three PE1 experiments. This work includes, but is not limited to, geologic mapping, physical sample collection, analysis of material properties, geophysical borehole logging, and in-situ measurements. This information was collected by a large, dedicated team and was used to inform site construction, finalize instrumentation placement, generate Geologic Framework Models, feed pre-experiment predictions, and facilitate post-experiment data analysis

58 GEOSCIENCES↗

LYNM-PE1 Seismic Parameters from Borehole Log, Laboratory, and Tabletop Measurements

The goal of this work is to provide a database of quality-checked seismic parameters that can be integrated with the Geologic Framework Model (GFM) for the LYNM-PE1 (Low Yield Nuclear Monitoring – Physical Experiment 1) testbed. We integrated data from geophysical borehole logs, tabletop measurements on collected core, and laboratory measurements. We reviewed for internal consistency among each measurement type, documented the caveats of measurement conditions, and integrated lithologic logs to check the validity of outlier values. The resulting consolidated parameter tables can be used as inputs for modeling and analysis codes and are designed to interface with the GFM, which is being actively developed.

58 GEOSCIENCES↗

LYNM PE1 Pre-Experiment A Site Characterization Report

Underground chemical explosive experiments such as LYNM PE1 generate large multi-phenomenological datasets, require complex site preparation and build out, and utilize cutting edge models and analysis techniques to analyze and simulate the explosion-induced signals. This wide range of outcomes makes it a necessity to thoroughly characterize the testbed in advance of experiments in a way that complements the wide suite of data being generated. Here, we present a broad overview of the site characterization work and data collection that was conducted before Experiment A, which is the first in a series of three PE1 experiments. This work includes, but is not limited to, geologic mapping, physical sample collection, analysis of material properties, geophysical borehole logging, and in-situ measurements. This information was collected by a large, dedicated team and was used to inform site construction, finalize instrumentation placement, generate Geologic Framework Models, feed pre-experiment predictions, and facilitate post-experiment data analysis.

45 MILITARY TECHNOLOGY, WEAPONRY, AND NATIONAL DEF↗

LYNM PE1 Shot A Meteorology Team Technical Report

Weather support for Shot A was done by NOAA’s Air Resources Laboratory (ARL) / Special Operations and Research Division (SORD) and Lawrence Livermore National Laboratory (LLNL). Weather support activities included wind and precipitation forecasting, maintaining and monitoring PE1 meteorology towers MT02-11, maintaining and monitoring the ARL/SORD tower on Aqueduct Mesa (A12AI, also called MT01), maintaining and monitoring the Blackbrush energy flux tower, radiosonde preparation and launch, providing weather conditions on shot day for go/no-go criteria, and quality control and submission of the datasets. ARL/SORD additionally maintains and monitors the meteorological tower network (Mesonet) and sodar (at Desert Rock) for NNSS.

54 ENVIRONMENTAL SCIENCES↗

Description of the Gas Sampling and Circulation System for the LYNM PE1-A Experiment

A series of multiphysics experiments, referred to as Physics Experiment 1 (PE1) is underway at the U.S. Nevada National Security Site. The PE1 series includes detonations of three underground chemical explosions. As the name implies, there are a number of experiments investigating the signals generated by the explosion. The experiment series objectives are outlined in a report from Lawrence Livermore National Laboratory.1 One of the experiments is a gas migration experiment. Gas tracers were imbedded in the explosives and gas sampling boreholes were installed in the formation in the test bed. Connected to the monitoring points is a circulation system that moves gas to a central measurement location. This report does not describe the gas analysis or collection systems, but rather the circulation system that provides the gas for measurement. Here, we have combined four project documents into a single report that describes the design, build, installation, testing, and operation of the gas sampling network.

42 ENGINEERING↗

Temperature and Pressure Instrumentation for LYNM PE1 Chemical Explosive Testing

Underground chemical explosive testing has been conducted at the Nevada National Security Site under the Physics Experiment 1 (PE1) to validate explosive computer modeling and, ultimately, improve the accuracy of subsurface explosive detection. This SAND Report describes the dynamic temperature and pressure measurements within the chamber induced by the chemical explosive for the first of three experiments, PE1-A. The report details the instrumentation used for the experiment, the emplacement of the hardware, and the measured results. Dynamic temperature measurements were accomplished with the use of optical spectrometers and dynamic pressure was measured with a series of high-rated pressure transducers. This report includes details of the design and results of four cavity sensor systems used to measure early-time temperature, early-time pressure, late-time temperature, and late time pressure. The outcomes of PE1-A were used to inform the design of the remaining PE1 series experiments, PE1-B and PE1-DL.

45 MILITARY TECHNOLOGY, WEAPONRY, AND NATIONAL DEF↗

LYNM Containment Hydrogeology Data Update for FY25

This report presents new two-phase flow parameters measured in samples of vitric tuff units located stratigraphically above the PE1 A chamber, which intersect or are near the top of the B and DL chambers. These two-phase flow data show the permeability, porosity, and mean pore size of these units to be higher than the stratigraphic units below them. These data indicate the rocks support fast gas transport (high porosity and permeability) across these units, depending on their water content.

58 GEOSCIENCES↗

Codes for "Shallow Soil Response to a Buried Chemical Explosion with Geophones and Distributed Acoustic Sensing" DAG - 01101646

The codes reproduce the figures of the manuscript entitled "Shallow Soil Response to a Buried Chemical Explosion with Geophones and Distributed Acoustic Sensing" submitted to Journal of Geophysical Research - Solid Earth. Geophone data and Distributed acoustic sensing (DAS) data recorded during the Phase II of the The Source Physics Experiment (SPE) along a fiber-optic cable offshore were processed to understand the response of the shallow subsurface to an explosion. This Ground-based Nuclear Detonation Detection (GNDD), Low Yield Nuclear Monitoring (LYNM), and Source Physics Experiment (SPE) research was funded by the National Nuclear Security Administration, Defense Nuclear Nonproliferation Research and Development (NNSA DNN R&D).

Viens, Loic↗

Waveform Data Quality Assessment

Healthy seismoacoustic sensors and accurate metadata are critical to all the science objectives of both the Source Physics Experiment (SPE) Rock Valley Direct Comparison (RV/DC) and LowYield Physics Experiment-1 (LYNM PE-1). Both projects share similar seismoacoustic stations. We provide a plan on how to move forward with waveform data quality assessments (QA) to the working groups. The identification of stations with instrument response errors will be useful to researchers using amplitudes to study source effects and Earth attenuation. The data QA can also be useful for field technicians to help identify and correct problem sites.

47 OTHER INSTRUMENTATION↗

Standoff Detection of Chemical Plumes Using Swept-ECQCL Remote Detection Technology: Results from EMRTC Complex Terrain Dual Tracer Experiment

As part of the Complex Terrain Dual Tracer Experiments performed in support of the LYNM program, a swept-wavelength external cavity quantum cascade laser (swept-ECQCL) remote detection system was deployed to measure chemical plume propagation with high temporal resolution. The swept-ECQCL remote detection technology was initially developed at PNNL, and is now under further development at Opticslah, LLC under SBIR funding from DOE (DOE SBIR Phase I Project DE-SC0019855, Remote Detection Technologies, Program Manager Chris Ramos). The swept-ECQCL technology provides a single-frequency infrared laser source which is rapidly scanned over a large wavelength range to measure the infrared absorption of gases, liquids, or solids. Analysis of the measured infrared absorption spectrum is used to detect, identify, and quantify the chemical species which are present. While most previous laser-based techniques used small wavelength tuning ranges to measure only a few isolated spectral lines of a few species, the swept-ECQCL provides the large tuning range needed to measure multiple species simultaneously, and to detect broad absorption features from large molecules or condensed phase materials. In addition, the swept-ECQCL systems have high enough spectral resolution and sensitivity to measure narrow lines of small molecules and determine isotope ratios. The remote detection system for gas plumes is based on the swept-ECQCL technology, and consists of a swept-ECQCL source, infrared detector, control electronics, and beam transmitting and alignment optics. The remote detection system directs the infrared output of the swept-ECQCL to a target retro reflector typically located at ~10-10,000 m distance. The swept-ECQCL wavelength is varied continuously over a large wavelength range (>1000 nm) at rates up to 1000 Hz. The swept ECQCL light reflected from the remote target is collected and focused onto an infrared photodetector. By measuring the detector signal continuously as the swept-ECQCL wavelength is varied, a time-series of absorption spectra are measured for the gases along the beam line of-sight. Based on analysis and fitting of the measured absorption spectra, the time-dependent chemical concentrations of species are determined. Multiple species and mixtures can be detected simultaneously, for all species with absorption features above the sensor noise floor. The sensor output is thus a continuous, high-speed record of identified chemicals along with their concentrations and isotope ratios of interest. The high-speed operation enables low-noise operation in conditions of atmospheric turbulence and allows tracking of fluctuating concentrations in transient chemical plumes as needed for reliable remote detection applications. All components operate with minimal cooling requirements and no cryogens are needed. In addition, the output infrared light is invisible with an intensity below the maximum permissible exposure (MPE) threshold of 100 mW/cm2 for these infrared wavelengths and thus eye safe. The measurement concept for plume detection using the swept-ECQCL remote detection system is as follows. The ECQCL beam is directed toward a remote retro-reflector, which reflects the beam back to the ECQCL system where it is focused onto an infrared photodetector. The line-of-sight from the ECQCL system to the retro-reflector defines the measurement path. The detected infrared signal is recorded continuously and detects the absorption of molecular species along the measurement path. Before a plume release, the system measures absorption from atmospheric constituents, which in this LWIR band consist primarily of lines from H 2 O and CO 2 , with additional weaker absorption from N 2 O, NH 3 , and O 3 possibly contributing. The system then measures any changes in absorption due to the tracer compounds when they enter the measurement path. The shape of absorption features is used to distinguish and identify the different tracer compounds, and the strength of the absorption is used to determine the path-integrated concentration – also called the column density.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Low Yield Nuclear Monitoring Physics Experiment 1 – Integrated Data Acquisition System Design and Initial Observations

The report documents the design of the Integrated Data AcQuisition (IDAQ) system and observations recorded during the first in a series of underground chemical explosions conducted on the Nevada National Security Site (NNSS) in southern Nevada. Experiments are funded as part of Low Yield Nuclear Monitoring (LYNM) research and development within the United States National Nuclear Security Administration NA-22 nuclear non-proliferation program. The series is part of the broader Physical Experiment 1 (PE1) being conducted in and around the P-tunnel facility on the NNSS. Each explosive experiment utilizes several tons of comp-B to generate signals recorded by a broad suite of instrumentation. The IDAQ serves as the backbone for all subsurface instrumentation providing precise time synchronization, remote control, data exfiltration and backup, along with recording several sensing modalities throughout the underground complex that includes ground motion, environmental conditions, and electromagnetic signals.

45 MILITARY TECHNOLOGY, WEAPONRY, AND NATIONAL DEF↗

Measurement of Close-in Ground Motion from an Underground Chemical Explosion

Understanding the geophysical response near an underground explosion is crucial for generating insights into the source and emplacement conditions that produce distinct observations in monitoring scenarios occurring at greater distances. Recently, Shot A of the Low Yield Nuclear Monitoring (LYNM) Physics Experiment 1 (PE1) series was conducted at the Nevada National Security Site to provide ground truth for subsurface explosion signal models. This experiment resulted in measuring near-source ground motion at distances ranging from 70 to 1000 m/kt with a 99% success rate, yielding high-fidelity knowledge of the near-field response that can serve as benchmarks for future numerical modeling and experiment planning. However, technical challenges exist in observing near-source phenomena while safeguarding sensitive data acquisition components from the detrimental effects of ground motion in the subsurface. This report outlines tools and techniques to address challenges associated with observing near-source accelerations and within the tunnel drift of the PE1 test bed. Additionally, we describe key systems designed with both modern advancements and legacy guidance to maximize the collection of high-quality ground motion data, which may be applied to constitutive and computational models, leading to new or improved understanding of the near- and far-field signals produced by underground explosions.

45 MILITARY TECHNOLOGY, WEAPONRY, AND NATIONAL DEF↗

Dynamic Networks Experiment 2

Item Purpose: Presentation of LYNM DN DNE2 at the AFRL TIM. Internal Peer Review Status: This item has completed internal peer review. HQ review status: This item has been reviewed and approved by HQ.

Berg, Elizabeth Mary [Sandia National Laboratories↗

Event Classifications on DNE2 Main Experiment Data using a Convolutional Neural Network Ensemble

The Dynamic Networks (DN) Experiment for FY24 (DNE2) is an experiment within DN with the goal of quantitatively evaluating the effectiveness of solutions developed so far by various researchers under the Low Yield Nuclear Monitoring (LYNM) program using a shared set of metrics and datasets. A key component of this experiment is the mimicking of a signature processing pipeline, and comparing currently accepted and standard-use processing methods to more state-of-the-art processes developed under DN. In this work, we focus specifically on the Event Characterization (EC) Focus Area (FA) of the pipeline, where a seismic event’s magnitude, yield and class are identified. We use Deep Learning (DL) to classify the type of events being processed as either earthquakes (EQs) or explosions (EXs) for three iterations of experiment datasets. The model is noticeably more confident and accurate in classifying explosions than earthquakes, reflecting a known shortcoming of the model, that being of a bias towards predicting explosions over earthquakes in the west coast due to training data biases.

97 MATHEMATICS AND COMPUTING↗