Search NASA⌕ Search

SEARCH · Search NASA

Results for “Large Scale Heating Test”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Proportional and Integral Thermal Control System for Large Scale Heating Tests

The National Aeronautics and Space Administration Armstrong Flight Research Center (Edwards, California) Flight Loads Laboratory is a unique national laboratory that supports thermal, mechanical, thermal/mechanical, and structural dynamics research and testing. A Proportional Integral thermal control system was designed and implemented to support thermal tests. A thermal control algorithm supporting a quartz lamp heater was developed based on the Proportional Integral control concept and a linearized heating process. The thermal control equations were derived and expressed in terms of power levels, integral gain, proportional gain, and differences between thermal setpoints and skin temperatures. Besides the derived equations, user's predefined thermal test information generated in the form of thermal maps was used to implement the thermal control system capabilities. Graphite heater closed-loop thermal control and graphite heater open-loop power level were added later to fulfill the demand for higher temperature tests. Verification and validation tests were performed to ensure that the thermal control system requirements were achieved. This thermal control system has successfully supported many milestone thermal and thermal/mechanical tests for almost a decade with temperatures ranging from 50 F to 3000 F and temperature rise rates from -10 F/s to 70 F/s for a variety of test articles having unique thermal profiles and test setups.

Thermal Control System↗

A radiant heating test facility for space shuttle orbiter thermal protection system certification

A large scale radiant heating test facility was constructed so that thermal certification tests can be performed on the new generation of thermal protection systems developed for the space shuttle orbiter. This facility simulates surface thermal gradients, onorbit cold-soak temperatures down to 200 K, entry heating temperatures to 1710 K in an oxidizing environment, and the dynamic entry pressure environment. The capabilities of the facility and the development of new test equipment are presented.

Sherborne, W. D.↗

A technique for scale model rocket base heating tests in a very large vacuum chamber

A series of tests was performed with a 0.040 scale Shuttle Orbiter Base Heating Model in a large vacuum chamber to determine the thermal effects of engine plume recirculation and direct engine plume impingement. The oxygen- and hydrogen-fueled model was fired through a range of simulated altitudes and configurations with varied engine gimbal angles and 'engine-out' combinations. Some of the special problems associated with conducting tests of this type related primarily to obtaining valid temperature and pressure data in the extremely short run times available. Run time is limited by the reflection of shock waves from the chamber wall, propellant charge-tube wave times, the time required to reach steady-state conditions for the engines, and model heating limitations. The 'data window' for potentially valid data usually begins with stabilized engine conditions and terminates with pressure perturbations from either of the aforementioned shock waves. The general approach for coping with these limitations and the method used to obtain valid data during the short data window (of the order of thirty milliseconds) are discussed.

Williams, F. U.↗

The 60-MW Shuttle Interaction Heating Facility

An arc-heated wind-tunnel system described in the present paper will simulate aerodynamic heating in large-scale tests of the thermal protection system of the Shuttle Orbiter Vehicle during entry. The system provides for large-scale subsystem tests in high-enthalpy streams with boundary layer flows at high Reynolds numbers and for large test-body sizes in stagnation flows. The discussion covers the design concept of the arc-jet systems, the extensive hardware developments of the arc heater to provide reliable operation, and verification and performance measurements of the system's operating envelopes.

W Winovich↗

Technology Demonstration Mission (TDM) Evolvable Cryogenics (eCryo) Project: Structural Heat Intercept, Insulation, and Vibration Evaluation Rig (SHIIVER) - Test Plan

The initial test of the SHIIVER system includes multilayer insulation and vapor cooled structure. Testing will occur in the In-Space Propulsion Facility (thermal/vacuum) and RATF (acoustic) facilities at Plum Brook Station in Sandusky Ohio. The testing will demonstrate the performance benefits of multilayer insulation and vapor based heat intercept on a “large scale” test article in a manner befitting large upper stages.

Large Scale Hydrogen Testing, Cryogenics, Multilay↗

Evaluation of Heating Methods for Thermal Structural Testing of Large Structures

An experimental study was conducted to evaluate different heating methods for thermal structural testing of large scale structures at temperatures up to 350 F as part of the High Speed Research program. The heating techniques evaluated included: radiative/convective, forced convective, and conductive. The radiative/convective heaters included finned strip heaters, and clear and frosted quartz lamps. The forced convective heating was accomplished by closed loop circulation of heated air. The conductive heater consisted of heating blankets. The tests were conducted on an 1/8 inch thick stainless steel plate in a custom-built oven. The criteria used for comparing the different heating methods included test specimen temperature uniformity, heater response time, and consumed power. The parameters investigated included air circulation in the oven, reflectance of oven walls, and the orientation of the test specimen and heaters (vertical and horizontal). It was found that reflectance of oven walls was not an important parameter. Air circulation was necessary to obtain uniform temperatures only for the vertically oriented specimen. Heating blankets provided unacceptably high temperature non-uniformities. Quartz lamps with internal air circulation had the lowest power consumption levels. Using frosted quartz lamps with closed loop circulation of cool air, and closed loop circulation of heated air provided the fastest response time.

Daryabeigi, Kamran↗

Development of fire test methods for airplane interior materials

Fire tests were conducted in a 737 airplane fuselage at NASA-JSC to characterize jet fuel fires in open steel pans (simulating post-crash fire sources and a ruptured airplane fuselage) and to characterize fires in some common combustibles (simulating in-flight fire sources). Design post-crash and in-flight fire source selections were based on these data. Large panels of airplane interior materials were exposed to closely-controlled large scale heating simulations of the two design fire sources in a Boeing fire test facility utilizing a surplused 707 fuselage section. Small samples of the same airplane materials were tested by several laboratory fire test methods. Large scale and laboratory scale data were examined for correlative factors. Published data for dangerous hazard levels in a fire environment were used as the basis for developing a method to select the most desirable material where trade-offs in heat, smoke and gaseous toxicant evolution must be considered.

Tustin, E. A.↗

Demonstration of Multilayer Insulation, Vapor Cooling of Structure, and Mass Gauging for Large Scale Upper Stages: Structural Heat Intercept, Insulation, and Vibration Evaluation Rig (SHIIVER) Final Report

Testing was completed on the Structural Heat Intercept, Insulation, and Vibration Evaluation Rig (SHIIVER) between August 2019 and January 2020. SHIIVER was designed to be a test bed for the scaling of cryogenic fluid management technologies as applied to large upper stages and long duration in-space stages. The hardware consists of a 4 meter diameter stainless steel tank, structural skirts supporting the tank in the aft direction, and an aluminum forward skirt with vapor cooling channels bolted to it. The initial testing of the SHIIVER hardware was with liquid hydrogen and liquid nitrogen (as a substitute fluid for liquid oxygen and liquid methane) and sought to demonstrate the use of boil-off vapor to intercept heat on a structural skirt, multilayer insulation (MLI) on the tank domes, and the radio frequency mass gauge (RFMG). Testing was completed in four stages: a baseline thermal vacuum test prior to installation of the MLI, a thermal vacuum test after the MLI installation, a reverberant acoustic test, and a subsequent thermal vacuum test to verify that no damage occurred during the reverberant acoustic testing. Each thermal vacuum test with chamber wall at ambient temperature and vacuum level in the 10-6 torr range was conducted continuously between approximately 90% full and 25% full. Test results showed that the vapor cooling reduced the heat load to the tank by approximately 10%, but the boil-off by less than 3% at 50% full with no MLI on the domes. It reduced the heat load to the tank by approximately 10%, but the boil-off was essentially unchanged at 50% full whether or not vapor cooling was operational with MLI on the domes. The MLI reduced the heat load to the tank by approximately 40% at all fill levels, but the boil-off by approximately 25% at 90% full and 45% below 65% full. The RFMG performed well over all fill ranges, and several RF tank modes were used to gauge the mass of fluid in the tank. SHIIVER was then exposed to an acoustic environment of 147 dB OASPL (overall sound pressure level) in a reverberant chamber. The acoustic environment and profile envelopes the upper stage internal acoustic level of several different modern launch vehicles. No structural or thermal performance changes were observed as a result of acoustic testing. Final thermal vacuum testing after the acoustic testing showed no degradation to the MLI due to the acoustic environment as measured via system heat loads.

SHIIVER↗

Thermally-Conductive Metallic Coatings and Applications for Heat Removal on In-Space Cryogenic Vehicles

For large in-space cryogenic upper stages, substantial axial heat removal from a forward skirt by vapor-based heat interception may not be achieved by simple attachment methods unless sufficient thermal conductance from the skirt to the cooling fluid can be achieved. Preferable methods would allow for the addition of the cooling system to existing structure with minimal impact on the structure. Otherwise, significant modification to the basic structural design andor novel and complex attachment mechanisms with high effective thermal conductance are likely to be required. The approach being pursued by evolvable Cryogenics (eCryo) is to increase the thermal performance of a relatively simple attachment system by applying metallic or other thermally conductive material coatings to the mating surface area of the fluid channel where it is attached the skirt wall. The expectation of candidate materials is that the dramatic increase in conductivity of pure metals at temperatures close to liquid hydrogen vapor temperature will compensate for the reduced actual contact area typical of mechanical joints. Basic contact conductance data at low temperatures for candidate interface materials is required to enable the test approach. A test rig was designed at NASA Glenn Research Center to provide thermal contact resistance testing between small sample coupons coated with conductive material via electron beam evaporation, a low-temperature option that will not affect physical properties of base materials. Average coating thicknesses were 10 k. The test fixture was designed to mount directly to a cryocooler cold head within a vacuum test chamber. The purpose of this test was to determine qualitative contact conductance between various test samples. Results from this effort will be implemented in a sub-scale vapor-based heat interception test, where the applicability for increased heat removal on large structural skirts will be considered.

small scale testing↗

An investigation of the energy balance of solar active regions using the ACRIM irradiance data

The correlation between the irradiance (as measured by the Active Cavity Radiometer Irradiance Monitor and the Earth Radiation Budget) as corrected for sunspot flux deficit (which is responsible for most of the variance of the uncorrected signal) and both the 205 nm flux (as measured by Nimbus 7) and a photometric facular index is discussed. The computer program which simulates two-dimensional convection in a compressible, stratified medium is described. Equipment which was acquired to perform high precision, white-light observations of sunspot areas, and procedures were tested. Analysis of observations of large scale convective heat inhomogeneities which were obtained in May 1985 was begun.

Petro, L. D.↗

Results of Use of Heat Flux Sensors on Liquid Hydrogen Tanks

Heat flux sensors were used to characterize the performance of insulation on the Structural Heat Intercept, Insulation, and Vibration Evaluation Rig (SHIIVER), a large-scale test article designed to simulate upper stage cryogenic propellant tank thermal performance in simulated space environments. Usually, the insulation heat loads are derived from calculations removing all other heat sources and attributing the residual heat load to the insulation system. Testing for SHIIVER included the tank being just insulated with spray-on-foam insulation as well as covering the domes with multilayer insulation while leaving the barrel section insulated with spray-on-foam. Heat flux sensors were located at multiple locations on both domes as well as on the barrel section of the tank. Results from the SHIIVER testing using the heat flux sensors are compared to other calculated heat inputs for both liquid nitrogen and liquid hydrogen testing as a function of tank fill level. Further investigation into the transient nature of the SHIIVER testing including the heat flux sensors provided insight into heat flow patterns that may not have been otherwise seen using temperature sensors and calculated insulation heat loads. While the demonstrated uncertainties in the absolute values in the heat flux sensors are high, the values and the trends match well with other calculation methods. The results of SHIIVER allow for the use of heat flux sensors for measurements of insulation performance and dynamic system thermal response for future applications.

Cryogenic Fluid Management↗

Results of Use of Heat Flux Sensors on Liquid Hydrogen Tanks

ABSTRACT: Heat flux sensors were used to characterize the performance of insulation on the Structural Heat Intercept, Insulation, and Vibration Evaluation Rig (SHIIVER), a large-scale test article designed to simulate upper stage cryogenic propellant tank thermal performance in simulated space environments. Usually, the insulation heat loads are derived from calculations removing all other heat sources and attributing the residual heat load to the insulation system. Testing for SHIIVER included the tank being just insulated with spray-on-foam insulation as well as covering the domes with multilayer insulation while leaving the barrel section insulated with spray-on-foam. Heat flux sensors were located at multiple locations on both domes as well as on the barrel section of the tank. Results from the SHIIVER testing using the heat flux sensors are compared to other calculated heat inputs for both liquid nitrogen and liquid hydrogen testing as a function of tank fill level. Further investigation into the transient nature of the SHIIVER testing including the heat flux sensors provided insight into heat flow patterns that may not have been otherwise seen using temperature sensors and calculated insulation heat loads. While the demonstrated uncertainties in the absolute values in the heat flux sensors are high, the values and the trends match well with other calculation methods. The results of SHIIVER allow for the use of heat flux sensors for measurements of insulation performance and dynamic system thermal response for future applications.

Cryogenic Fluid Management↗

STE thrust chamber technology: Main injector technology program and nozzle Advanced Development Program (ADP)

The purpose of the STME Main Injector Program was to enhance the technology base for the large-scale main injector-combustor system of oxygen-hydrogen booster engines in the areas of combustion efficiency, chamber heating rates, and combustion stability. The initial task of the Main Injector Program, focused on analysis and theoretical predictions using existing models, was complemented by the design, fabrication, and test at MSFC of a subscale calorimetric, 40,000-pound thrust class, axisymmetric thrust chamber operating at approximately 2,250 psi and a 7:1 expansion ratio. Test results were used to further define combustion stability bounds, combustion efficiency, and heating rates using a large injector scale similar to the Pratt & Whitney (P&W) STME main injector design configuration including the tangential entry swirl coaxial injection elements. The subscale combustion data was used to verify and refine analytical modeling simulation and extend the database range to guide the design of the large-scale system main injector. The subscale injector design incorporated fuel and oxidizer flow area control features which could be varied; this allowed testing of several design points so that the STME conditions could be bracketed. The subscale injector design also incorporated high-reliability and low-cost fabrication techniques such as a one-piece electrical discharged machined (EDMed) interpropellant plate. Both subscale and large-scale injectors incorporated outer row injector elements with scarfed tip features to allow evaluation of reduced heating rates to the combustion chamber.

Source record↗

Zero-Boiloff Cryogenic Storage Cryocooler Integration Test

Developments in NASA Glenn Research Center's Centaur work have led to an exciting new cryogenic storage concept being considered for future NASA space missions. With long-duration cryogenic storage, propellants will boil off because of the environmental heating of the tank. To accommodate these losses, extra propellant is required along with larger propellant tanks. Analyses of space transportation concepts show that spacetransfer cryogenic stages with the zero boiloff (ZBO) cryogenic storage concept reduce the stage mass for missions longer than approximately 45 days in low Earth orbit. The ZBO system consists of an active cryocooling system using a cryocooler in addition to traditional passive thermal insulation. Engineers at Glenn analyzed, designed, built, and bench tested a heat exchanger and integration hardware for a large-scale ZBO demonstration for the NASA Marshall Space Flight Center. The heat exchanger, which transfers the heat that enters the tank from the fluid to the cryocooler, must limit the temperature difference across it to limit the cryocooler size and power requirements. With a low temperature difference, the system efficiency is improved. For that temperature difference to be reduced, the thermal conductivity must be as high as possible at liquid hydrogen temperatures, around 25 K (-248 C). In addition, it is important for the heat exchanger to be welded to a stainless steel flange and have enough strength to accommodate piping stress. High-conductivity copper was selected and fabricated, then integrated with the stainless steel piping tee as shown in the cutaway representation. Literature showed that this conductivity might range from 2 to 100 W/cm/K but that is was likely to be around 13 W/cm/K. Unexpectedly, this conductivity was measured to be 23 W/cm/K, which limited the temperature increase along the heat exchanger to just 2 K. This limited temperature increase, compared with the predicted difference of 3.5 K, improves the overall system efficiency by 7.4 percent and limits the expected integration losses to a projected 4 percent with a flight design for liquid hydrogen storage. These results improve the cryocooler integration concept by allowing the cryocooler to operate at a lower input power, or by potentially permitting a smaller cryocooler to be selected.

Plachta, David W.↗

Flowfield Analysis of a Small Entry Probe (SPRITE) Tested in an Arc Jet

A novel concept of small size (diameter less than 15 inches) entry probes named SPRITE (Small Probe Re-entry Investigation for TPS Engineering) has been developed at NASA Ames Research Center (ARC). These flight probes have on-board data acquisition systems that have also been developed in parallel at NASA ARC by Greg Swanson1. Flight probes of this size facilitate testing over a wide range of conditions in arc jets available at NASA ARC, thereby fulfilling a 'test what you fly' paradigm. As indicated by the acronym, these probes, with suitably tailored trajectories, are primarily meant to be robotic flight test beds for TPS materials, although the design is flexible enough to accommodate additional objectives of flight-testing other vehicle subsystems. A first step towards establishing the feasibility of the SPRITE concept is to arc-jet test fully instrumented models at flight scale. In a follow-on to the Large-Scale Article Tests (LSAT2) performed in the 60 MW Interaction Heating Facility (IHF) in late 2008/early 2009, a full-scale model of Deep Space-2 (DS23) made of red oak was tested in the 20 MW Aerodynamic Heating Facility (AHF). There were no issues with mass capture by the diffuser for blunt bodies of roughly 15 inches diameter tested in the 18-inch nozzle of the AHF. Building on this initial success, two identical test articles - SPRITE-T1-1 and SPRITE-T1-2 (T1 indicating the choice of back shell geometry) - were fabricated, and one of them, SPRITE-T1-1, was tested in the AHF recently. Both these test articles, 14 inches in diameter, have a 45deg sphere-cone (like DS2) made of PICA bonded on to a 1/8th inch thick aluminum shell using RTV. The aft portion of the test article is a conical frustum (15deg cone angle) with LI-2200 bonded on to the aluminum shell. Each model is fully instrumented with: (a) thermocouples imbedded in plugs in the heat shield, (b) thermocouples bonded to the aluminum substructure; the thermocouples are distributed over the entire shell, and (c) a few strain gages. Data from some of the thermocouples and gages are acquired by the on-board data acquisition system (DAS), while data from the others are routed to the facility-provided DAS, thereby enabling a cross check on the in situ measurement capability. as inputs to v2.6.1 of the in-house materials thermal response code, FIAT

atmospheric entry↗

Experimental program for real gas flow code validation at NASA Ames Research Center

The experimental program for validating real gas hypersonic flow codes at NASA Ames is described. Ground based test facilities used include ballistic ranges, shock tubes and shock tunnels, arcjet facilities and heated air hypersonic wind tunnels. Also included are large scale computer systems for kinetic theory simulations and benchmark code solutions. Flight tests consist of the Aeroassist Flight Experiment, the Space Shuttle, Project Fire 2, and planetary probes such as Galileo, Pioneer Venus and PAET.

Deiwert, George S.↗

CFD Simulations of the IHF 13-Inch Nozzle Flow: 55° Sphere-Cone Model, Manufactured Fences and Gaps

Introduction to Arc-Jets and Testing - Arc-jets are primary facilities to test the performance of thermal protection systems (TPS) in an aerothermodynamic heating environment - Free jet test configuration with stagnation coupon or wedge models—conical nozzles - Semi-free jet test configuration with panel test articles—semi-elliptical nozzles A large-scale sphere-cone model, though similar to stagnation models, enables testing TPS materials in combinations of heat flux, pressure and shear different from those accessible in various stagnation and wedge tests

Arc-jets↗

Large-scale pool fire test recommendations

The important aspects of external pool fires are outlined. The research objectives are: (1) determine heat flux to surfaces as a function of pool size (convective and radiative heat flux); (2) obtain information that can be compared with theoretical models for radiative flux in the near field; and (3) predict radiative heat flux for arbitrary pool size. The measurements and instrumentation (calorimeters and thermocouples) used for pool fires are outlined.

Bankston, C. P.↗