Laser calibration system for time of flight scintillator arrays
Not provided.
SEARCH · Search NASA
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Not provided.
This article reports the laser calibration of the hadronic Tile Calorimeter of the ATLAS experiment in the LHC Run 2 data campaign. The upgraded Laser II calibration system is described. The system was commissioned during the first LHC Long Shutdown, exhibiting a stability better than 0.8% for the laser light monitoring. The methods employed to derive the detector calibration factors with data from the laser calibration runs are also detailed. These allowed to correct for the response fluctuations of the 9852 photomultiplier tubes of the Tile Calorimeter with a total uncertainty of 0.5% plus a luminosity-dependent sub-dominant term. Finally, we report the regular monitoring and performance studies using laser events in both standalone runs and during proton collisions. These studies include channel timing and quality inspection, and photomultiplier linearity and response dependence on anode current.
The present invention comprises an approach for calibrating the sensitivity to polarization, optics degradation, spectral and stray light response functions of instruments on orbit. The concept is based on using an accurate ground-based laser system, Ground-to-Space Laser Calibration (GSLC), transmitting laser light to instrument on orbit during nighttime substantially clear-sky conditions. To minimize atmospheric contribution to the calibration uncertainty the calibration cycles should be performed in short time intervals, and all required measurements are designed to be relative. The calibration cycles involve ground operations with laser beam polarization and wavelength changes.
The present invention comprises an approach for calibrating the sensitivity to polarization, optics degradation, spectral and stray light response functions of instruments on orbit. The concept is based on using an accurate ground-based laser system, Ground-to-Space Laser Calibration (GSLC), transmitting laser light to instrument on orbit during nighttime substantially clear-sky conditions. To minimize atmospheric contribution to the calibration uncertainty the calibration cycles should be performed in short time intervals, and all required measurements are designed to be relative. The calibration cycles involve ground operations with laser beam polarization and wavelength changes.
The Deep Underground Neutrino Experiment (DUNE) is a full experiment consisting of multiple detectors separated by a near and far site. DUNE will study long-baseline neutrino oscillations, which will provide insight into CP-violation, neutrino mass ordering, and the matter/antimatter asymmetry. Additionally, DUNE will search for nucleon decay and observe neutrinos from supernovae. DUNE relies on liquid argon time projection chambers (LAr TPCs), an excellent technology for tracking particles and reconstructing their interactions with high precision. To achieve its goals, DUNE is supported by the ProtoDUNE experiments at CERN, which serve as large-scale prototypes to validate detector technologies and calibration systems. The precise calibration of the electric field within the detector is vital for accurate 3D reconstruction of particle tracks, particularly in maintaining the consistency of charge measurements along the drift path. This work presents the development and implementation of a laser calibration system designed for ProtoDUNE-II. This poster involved the physical installation and commissioning of the laser system. The commissioning process included extensive testing to ensure alignment and operational efficiency, such as rotating the laser to observe behavior of tracks. The groundwork established during these steps is crucial for future data analysis, aiming to measure the electron lifetime (in the active volume) and map the electric field inside the detector with high precision.
The Muon g-2 experiment at Fermilab has the main goal to measure the muon anomalous magnetic moment $a_{µ}$ = ($g$ − 2)/2 to a precision of 0.14 parts per million (ppm), which means 4 times improvement in precision with respect to the final result from BNL: $a_{µ}$ (expt. BNL) = 11659208.0(6.3) × 10$^{−10}$ (0.54 ppm) In this report I summarize the work done at the $g$-2 experiment during my summer internship at Fermilab. In the first two weeks my first task has been to replace the NIM logic used in the Laser Calibration System with a new FPGA. Then, I was involved in the Lost Muons analysis studying both real data and MonteCarlo simulations.
The Air Force Research Laboratory/Directed Energy Directorate (AFRL/DE) and the NASA/Marshall Space Flight Center are planning a joint laser space calibration experiments using the HI-CLASS ladar system and the Advanced Electro-Optical System (AEOS) located at Maui Space Surveillance System (MSSS). These experiments will use ladar data to provide accurate range and signature measurements of calibration spheres with known sizes. Ancillary experiment benefits could include calibrating operational sensors, analyzing effects of orbital perturbations on micro-satellites, and correlating radar and optical signatures. In the first experiment, a GPS/laser beacon instrumented micro-satellite about 20 cm in diameter would be deployed from a Space Shuttle Hitchhiker canister. Orbiting in LEO, the micro-satellite would pass over MSSS on the average of two times per 24 hour period. A timing circuit would activate the GPS unit that would in turn activate the laser beacon at the appropriate time. The HI-CLASS/AEOS system will detect and acquire the micro-sat as it rises above the horizon and demonstrate that continuous track can be maintained throughout the pass. Orbital parameters will be obtained. This operational approach should maximize visibility to the ground-based laser while allowing battery life to be conserved thus extending the lifetime of the satellite. GPS data will be transmitted to the ground, providing independent location information down to cm accuracies for comparison and evaluation purposes.
The Air Force Research Laboratory/Directed Energy Directorate (AFRL/DE) and NASA/Marshall Space Flight Center (MSFC) are looking at a series of joint laser space calibration experiments using the 12J 15Hz CO2 High Performance CO2 Ladar Surveillance Sensor (FU-CLASS) system on the 3.67 meter aperture Advanced Electro-Optics System (AEOS). The objectives of these experiments are to provide accurate range and signature measurements of calibration spheres, demonstrate high resolution tracking capability of small objects, and support NASA in technology development and tracking projects. Ancillary benefits include calibrating radar and optical sites, completing satellite conjunction analyses, supporting orbital perturbations analyses, and comparing radar and optical signatures. In the first experiment, a Global Positioning System (GPS)/laser beacon instrumented microsatellite about 25 cm in diameter will be deployed from a Space Shuttle Hitchhiker canister or other suitable launch means. Orbiting in low earth orbit, the microsatellite will pass over AEOS on the average of two times per 24-hour period. An onboard orbit propagator will activate the GPS unit and a visible laser beacon at the appropriate times. The HI-CLASS/AEOS system will detect the microsatellite as it rises above the horizon, using GPS-generated acquisition vectors. The visible laser beacon will be used to fine-tune the tracking parameters for continuous ladar data measurements throughout the pass. This operational approach should maximize visibility to the ground-based laser while allowing battery life to be conserved, thus extending the lifetime of the satellite. GPS data will be transmitted to the ground providing independent location information for the microsatellite down to sub-meter accuracies.
An improved method of calibration has been devised for instruments that utilize tunable lasers to measure the absorption spectra of atmospheric gases in order to determine the relative abundances of the gases. In this method, CO2 in the atmosphere is used as a natural calibration standard. Unlike in one prior calibration method, it is not necessary to perform calibration measurements in advance of use of the instrument and to risk deterioration of accuracy with time during use. Unlike in another prior calibration method, it is not necessary to include a calibration gas standard (and the attendant additional hardware) in the instrument and to interrupt the acquisition of atmospheric data to perform calibration measurements. In the operation of an instrument of this type, the beam from a tunable diode laser or a tunable quantum-cascade laser is directed along a path through the atmosphere, the laser is made to scan in wavelength over an infrared spectral region that contains one or two absorption spectral lines of a gas of interest, and the transmission (and, thereby, the absorption) of the beam is measured. The concentration of the gas of interest can then be calculated from the observed depth of the absorption line(s), given the temperature, pressure, and path length. CO2 is nearly ideal as a natural calibration gas for the following reasons: CO2 has numerous rotation/vibration infrared spectral lines, many of which are near absorption lines of other gases. The concentration of CO2 relative to the concentrations of the major constituents of the atmosphere is well known and varies slowly and by a small enough amount to be considered constant for calibration in the present context. Hence, absorption-spectral measurements of the concentrations of gases of interest can be normalized to the concentrations of CO2. Because at least one CO2 calibration line is present in every spectral scan of the laser during absorption measurements, the atmospheric CO2 serves continuously as a calibration standard for every measurement point. Figure 1 depicts simulated spectral transmission measurements in a wavenumber range that contains two absorption lines of N2O and one of CO2. The simulations were performed for two different upper-atmospheric pressures for an airborne instrument that has a path length of 80 m. The relative abundance of CO2 in air was assumed to be 360 parts per million by volume (approximately its natural level in terrestrial air). In applying the present method to measurements like these, one could average the signals from the two N2O absorption lines and normalize their magnitudes to that of the CO2 absorption line. Other gases with which this calibration method can be used include H2O, CH4, CO, NO, NO2, HOCl, C2H2, NH3, O3, and HCN. One can also take advantage of this method to eliminate an atmospheric-pressure gauge and thereby reduce the mass of the instrument: The atmospheric pressure can be calculated from the temperature, the known relative abundance of CO2, and the concentration of CO2 as measured by spectral absorption. Natural CO2 levels on Mars provide an ideal calibration standard. Figure 2 shows a second example of the application of this method to Mars atmospheric gas measurements. For sticky gases like H2O, the method is particularly powerful, since water is notoriously difficult to handle at low concentrations in pre-flight calibration procedures.
Calibrator for measuring and modulating or demodulating laser outputs
A practical approach to developing an operational low-cost disdrometer hinges on implementing an effective in situ adaptive calibration strategy. This calibration strategy lowers the cost of the device and provides a method to guarantee continued automatic calibration. In previous work, a collocated tipping bucket rain gauge was utilized to provide a calibration signal to the disdrometer's digital signal processing software. Rainfall rate is proportional to the 11/3 moment of the drop size distribution (a 7/2 moment can also be assumed, depending on the choice of terminal velocity relationship). In the previous case, the disdrometer calibration was characterized and weighted to the 11/3 moment of the drop size distribution (DSD). Optical extinction by rainfall is proportional to the 2nd moment of the DSD. Using visible laser light as a means to focus and generate an auxiliary calibration signal, the adaptive calibration processing is significantly improved.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Explore the source record for details and available documents.