Exploration of polar direct drive wetted foam concepts for neutron sources on the National Ignition Facility laser
Explore the source record for details and available documents.
SEARCH · Search NASA
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Explore the source record for details and available documents.
In this study, we present the absolute calibration of the conical crystal for the zinc spectrometer (ZSPEC), an x-ray spectrometer at the OMEGA laser facility at the Laboratory for Laser Energetics. The ZSPEC was originally designed to measure x-ray Thomson scattering using flat or cylindrically curved highly oriented pyrolytic graphite crystals centered around Zn He-alpha emission at 9 keV. To improve the useful spectral range and collection efficiency of the ZSPEC, a conical highly annealed pyrolytic graphite crystal was fabricated for the ZSPEC. The conically bent crystal in the Hall geometry produces a line focus perpendicular to the spectrometer axis, corresponding to the detector plane of electronic detectors at large scale laser facilities such as OMEGA, extending the useful range of the spectrometer to 7–11 keV. Further, using data collected using a microfocus Mo x-ray source, we determine important characteristics of ZSPEC such as the dispersion, spatial resolution, and absolute sensitivity of the instrument. A ray-trace model of ZSPEC provides another point of agreement in calculations of the ZSPEC dispersion and crystal response.
Here we present a design and first use of a kJ level laser facility for research of non-local thermodynamic equilibrium atomic physics using the buried layer target method. The target design included a metal layer buried inside a plastic tamper with thicknesses tailored to the expected laser intensities. The target was illuminated from each side by two laser beams with intensities of 0.5–5 × 10 14 W/cm 2 . The advanced diagnostic suite included static and time-resolved imagers and spectrometers with various spectral resolutions. A 3D printed dual elliptically curved spectrometer is presented, and its results are compared to a traditional crystal spectrometer. Experimental results and radiation hydrodynamic simulations demonstrate that the target achieved the desired thermodynamic conditions of n e ≈ 10 21 –10 22 cm -3 and T e ≈ 1–2 keV.
Explore the source record for details and available documents.
The next generation of high-power lasers enables repetition of experiments at orders of magnitude higher frequency than what was possible using the prior generation. Facilities requiring human intervention between laser repetitions need to adapt in order to keep pace with the new laser technology. A distributed networked control system can enable laboratory-wide automation and feedback control loops. These higher-repetition-rate experiments will create enormous quantities of data. A consistent approach to managing data can increase data accessibility, reduce repetitive data-software development and mitigate poorly organized metadata. An opportunity arises to share knowledge of improvements to control and data infrastructure currently being undertaken. We compare platforms and approaches to state-of-the-art control systems and data management at high-power laser facilities, and we illustrate these topics with case studies from our community
Nuclear activation is a well-established technique for inferring neutron yields in laser direct-drive deuterium–tritium (DT) and deuterium–deuterium (D 2 ) implosions at the OMEGA Laser Facility. Zirconium has long been considered an excellent candidate for measuring DT neutron fusion yields by observing decays of the 90 Zr(n,2n) 89 Zr ground-state reaction. As it has a higher energy threshold than present activation detectors utilizing copper, zirconium provides a means to infer primary neutron yields that are less susceptible to being skewed due to neutron scattering within the experimental environment. However, with a 78.41-h half-life, it is not operationally practical to utilize this reaction for OMEGA experiments, which have a 1-h shot cycle. Zirconium’s 90 Zr(n,2n) 89 mZr reaction presents itself as a viable candidate to infer neutron yields within a shot cycle, given its half-life of 4.16 min. Here, we present an overview of the approach and methodology, utilizing first principles techniques, to infer the primary neutron yields from OMEGA DT fusion experiments by using both the isomeric and the ground-state reaction. Yields inferred from both reactions are compared, which are in good agreement between the two.
The results of the operation of a wavefront correction system based on a deformable bimorph mirror of the PEARL subpetawatt laser facility are presented. An improvement in the quality of focusing of laser radiation, which led to an increase in the Strehl ratio from 0.3 to 0.6, is demonstrated. The features of the compensation for phase distortions of the wavefront in the case of a low pulse repetition rate, as well as the correct allowance for the noise of the CCD camera when calculating the Strehl ratio are investigated. (paper)
The 1 page briefing on the dynamic materials campaigns in FY20 at the Omega Laser Facility is provided. This was published in the LLE Review, Volume 157.
The goal of this project is to provide operational support to run the Jupiter Laser Facility within the LaserNetUS network to achieve the following four objectives: • Develop new science, techniques, and platforms for discovery science and IFE research, in partnership with academia, other LaserNetUS nodes, and the greater community. • Advance the development of secondary sources of photons and particles for applications relevant to discovery science and IFE; • Serve as a testbed for new laser, optical, target, and diagnostic capabilities that will advance IFE; • Attract, train, and retain talent in high-energy-density and laser science that will be essential in furthering development of IFE, and help build new collaborations between national laboratory and academic researchers. We have accomplished our four objectives by: • Providing access to the three JLF platforms (Titan, Janus, and COMET) to LaserNetUS users after their proposals have been independently reviewed and ranked by the LaserNetUS PRP; • Providing expertise and technical capabilities to support focused science research thrusts at the facility; • Promoting and maintaining technical relationships and collaborations with other members of the LaserNetUS community to nurture and grow the discovery science and IFE workforce— especially students and early career scientists—on LaserNetUS facilities. • Augmenting JLF with specific improvements while coordinating efforts with LLNL organizations and collaborators to provide users with optimal laser, target, and diagnostic resources to help them maximize technical impact.
Driving of the nuclear fusion reaction p + 11 B → 3α + 8.7 MeV under laboratory conditions by interaction between high-power laser pulses and matter has become a popular field of research, owing to its numerous potential applications: as an alternative to deuterium–tritium for fusion energy production, astrophysics studies, and alpha-particle generation for medical treatment. One possible scheme for laser-driven p– 11 B reactions is to direct a beam of laser-accelerated protons onto a boron (B) sample (the so-called “pitcher-catcher” scheme). This technique has been successfully implemented on large high-energy lasers, yielding hundreds of joules per shot at low repetition. We present here a complementary approach, exploiting the high repetition rate of the VEGA III petawatt laser at CLPU (Spain), aiming at accumulating results from many interactions at much lower energy, to provide better control of the parameters and the statistics of the measurements. Despite a moderate energy per pulse, our experiment allowed exploration of the laser-driven fusion process with tens (up to hundreds) of laser shots. The experiment provided a clear signature of the reactions involved and of the fusion products, accumulated over many shots, leading to an improved optimization of the diagnostics for experimental campaigns of this type. In this paper, we discuss the effectiveness of laser-driven p– 11 B fusion in the pitcher–catcher scheme, at a high repetition rate, addressing the challenges of this experimental scheme and highlighting its critical aspects. Our proposed methodology allows evaluation of the performance of this scheme for laser-driven alpha particle production and can be adapted to high-repetition-rate laser facilities with higher energy and intensity.
Dear JLF community, I cannot believe I am now entering my third year as JLF director — time definitely flies when you are having fun! FY25 was another pivotal year for the Jupiter Laser Facility, marked by both scientific achievement and growing visibility for our community. Building on the successful reopening and refurbishment of the facility, we continued to demonstrate how JLF drives innovation in high energy density and fusion energy science, laser technology, and workforce development. Across Janus, Titan, and COMET, users executed a diverse portfolio of experiments, from dynamic compression and opacity measurements to laser plasma interactions, laboratory astrophysics, and advanced diagnostics. These efforts are highlighted in this report, including the development of new probes that capture the time evolution of plasmas on a single shot, and diagnostics and platforms that are already impacting experiments at NIF and other large facilities. JLF continues to serve as both a testbed for new ideas and a bridge to larger scale campaigns. FY25 also showcased the broader role of JLF within the Laboratory and the national HED science ecosystem. The NIF JLF User Groups Meeting in February brought nearly 180 participants to Livermore and highlighted the scientific progress made during JLF’s first full year of renewed operations. JLF research and users were recognized with Director’s Institutional Awards and Early and Mid Career awards, underscoring the quality and impact of the work performed here. Our team also contributed prominently to national conversations about laser safety, plasma physics, and inertial fusion energy through invited talks, conferences, and professional society leadership. JLF’s integration with LaserNetUS deepened this year as well. We launched a new technical exchange program across LaserNetUS facilities and kicked it off with a JLF team visit to the BELLA Center at Lawrence Berkeley National Laboratory. These exchanges are strengthening operations, sharing best practices, and improving the user experience across the network. Filming for the LaserNetUS “Behind the Scenes” series and participation in the annual LaserNetUS meeting further increased the visibility of our facility and our users. At the same time, JLF continues to play a central role in ambitious new programs, such as the Big Aperture Thulium laser effort funded through one of the DOE Office of Science Microelectronics Science Research Centers, which will use JLF infrastructure to explore next generation high rep rate lasers for EUV and x-ray source development. A core part of our mission remains training the next generation of scientists. In FY25, we welcomed another cohort of summer students, who joined experimental teams on Titan and presented their research at LLNL’s student poster symposium and national inertial fusion energy meetings. JLF users and early career scientists showcased their work at conferences across the country, highlighting experiments performed at the facility. These hands on experiences, and the mentoring provided by our staff and user teams, are central to JLF’s identity as a true user facility. Finally, FY25 reinforced JLF’s role as a focal point for partnerships and outreach. We hosted visits from international collaborators, science leaders, and we shared the story of the facility through venues such as the Big Ideas Lab podcast. These interactions help connect our work to a broader scientific and policy audience and open new pathways for collaboration. As we look ahead, the combination of refurbished hardware, new capabilities like STILETTO and enhanced short pulse performance on Titan, strong partnerships across LLNL and LaserNetUS, and a growing user community positions JLF for an even more ambitious program in the coming years. I am deeply grateful to our technical and operations staff for their dedication, to our LLNL partners for their continued support, and to our users for bringing bold, creative ideas to the facility. I look forward to more experiments, capabilities, partnerships, and groundbreaking science in the years to come! With brightest regards, Félicie Albert, JLF Director.
Our research focuses on designing all-reflective phase retarders (RPRs) to generate and maintain circularly polarized (CP) light for NSF OPAL and other multipetawatt laser facilities. Assuming that the input polarization is either s- or p-polarized, RPRs need to be used in an out-of-plane configuration. Here, we will discuss the impact of transporting and focusing optics on CP light.
A new neutron time-of-flight (nTOF) detector for deuterium–deuterium (DD)-fusion yield and ion-temperature measurements was designed, installed, and calibrated for the OMEGA Laser Facility. This detector provides an additional line of sight for DD neutron yield and ion-temperature measurements for yields exceeding 1 × 10 10 with higher precision than existing detectors. The nTOF detector consists of a 90-mm-diam, 20-mm-thick BC-422 scintillator and a gated Photek photomultiplier tube (PMT240). The PMT collects scintillating light through the 20-mm side of the scintillator without the use of a light guide. There is no lead shielding from hard x rays in order to allow the x-ray instrument response function of the detector to be measured easily. Instead, hard x-ray signals generated in implosion experiments are gated out by the PMT. The design provides a place for glass neutral-density filters between the scintillator and the PMT to avoid PMT saturation at high yields. The nTOF detector is installed in the OMEGA Target Bay along the P8A sub-port line of sight at a distance of 5.3 m from the target chamber center. In addition to DD measurements, the same detector can be used to measure the neutron yield and ion temperature from deuterium–tritium (DT) implosion targets in the 5 × 10 10 to 2 × 10 12 yield range. Here, the design details and the calibration results of this nTOF detector for both D 2 and DT implosions on OMEGA will be presented.
Charged particle spectrometry is a critical diagnostic to study inertial-confinement-fusion plasmas and high energy density plasmas. The OMEGA Laser Facility has two fixed magnetic charged particle spectrometers (CPSs) to measure MeV-ions. In situ calibration of these spectrometers was carried out using 241 Am and 226 Ra alpha emitters. The alpha emission spectrum from the sources was measured independently using surface-barrier detectors (SBDs). The energy dispersion and broadening of the CPS systems were determined by comparing the CPS measured alpha spectrum to that of the SBD. The calibration method significantly constrains the energy dispersion, which was previously obtained through the measurement of charged particle fusion products. Overall, a small shift of 100 keV was observed between previous and the calibration done in this work.
Extended x-ray absorption fine structure (EXAFS) measurements require a bright and continuous x-ray source and a detection system with high spectral resolution to capture the modulations of the absorption coefficient above the material absorption edge. When performing EXAFS measurements under laser-driven dynamic compression, it is hence critical to optimize the backlighter x-ray emission. In this study, a series of experiments has been conducted at the OMEGA laser facility to characterize titanium (Z = 22), iron (Z = 26), germanium (Z = 32), molybdenum (Z = 42), silver (Z = 47), and gold (Z = 79) foil backlighters irradiated with 3 kJ–12 kJ of laser energy. The spectra have been recorded using a dual crystal spectrometer (DCS), a two-channel transmission spectrometer covering 11 keV–45 keV and 19 keV–90 keV energy bands. The DCS has been calibrated so that the spectral intensities can be compared between different campaigns.
The rich and complex physics of inertial confinement fusion provides a unique and challenging space for high-fidelity first-principles modeling. Consequently, simulation codes that are used to design experiments are computationally expensive and lack the predictive capability required for extensive parameter exploration in search of a high-performing design for laser direct drive. In this article, we present two deep-learning-based predictive models intended to address these difficulties. The first model (TL DNN) acts as a fast emulator of simulations as well as experiments at the Omega Laser Facility. This model is trained on a simulation database and subsequently calibrated on experimental data using transfer learning. To facilitate the development of this model, an autoencoder is developed to reduce the dimensionality of the input space by compressing the laser pulse input. The model predicts key experimental scalar observables of Omega experiments with high accuracy and minimal computational cost. This deep neural net enables rapid exploration of a high-dimensional input parameter space for an optimal implosion design. The second model (DNN SM+) aims to extend the statistical modeling work of Lees et al. [Phys. Rev. Lett. 127, 105001 (2021)], by increasing the complexity of the model space and allowing for coupling between degradation terms. Since the model capacity of DNN SM+ is higher than the model of Lees et al., DNN SM+ can potentially provide an improvement in predictive capability, and we use this model to provide insight into complicated degradation dependencies.
Millimeter-sized CD foils fielded close (order mm) to inertial confinement fusion (ICF) implosions have been proposed as a game-changer for improving energy resolution and allowing time-resolution in neutron spectrum measurements using the magnetic recoil technique. This paper presents results from initial experiments testing this concept for direct drive ICF at the OMEGA Laser Facility. Additionally, while the foils are shown to produce reasonable signals, inferred spectral broadening is seen to be high (~5 keV) and signal levels are low (by ~20%) compared to expectation. Before this type of foil is used for precision experiments, the foil mount must be improved, oxygen uptake in the foils must be better characterized, and impact of uncontrolled foil motion prior to detection must be investigated.
Millimeter-sized CD foils fielded close (order mm) to inertial confinement fusion (ICF) implosions have been proposed as a game-changer for improving energy resolution and allowing time-resolution in neutron spectrum measurements using the magnetic recoil technique. This paper presents results from initial experiments testing this concept for direct drive ICF at the OMEGA laser facility. While the foils are shown to produce reasonable signals, inferred spectral broadening is seen to be high (~5 keV) and signal levels low (by ~20%) compared to expectation. Before this type of foil is used for precision experiments, the foil mount must be improved, oxygen uptake in the foils better characterized, and impact of uncontrolled foil motion prior to detection investigated.