Standoff analysis of laser-produced plasmas using laser-induced fluorescence
Not Available
SEARCH · Search NASA
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Not Available
Planar laser induced fluorescence (PLIF) imaging can potentially assess ion distributions and coupling in the context of super-Alfvenic ablation plasma expansions into magnetized background plasmas. In this feasibility study, we consider the application of PLIF to rapidly expanding carbon plasmas generated via energetic laser ablation of graphite. By utilizing hydrodynamic and collisional-radiative simulations, we identify schemes accessible to commercially available tunable lasers for the C I atom, the C II ion, and the C V ion. We then estimate the signal-to-noise ratios yielded by the schemes under reasonable experimental configurations.
Direct laser induced fluorescence measurements are shown of cross-field ion flows normal to an absorbing boundary that is aligned parallel to the axial magnetic field in a helicon plasma. We show Langmuir and emissive probe measurements of local density and plasma potential in the same region, as well as floating probe spectra near the boundary. With these measurements, we investigate the influence of ion-neutral collisionality on radial ion transport by varying the ratio of the ion gyro-radius, ρ{sub i}, to the ion-neutral collision length, λ, over the range 0.34 ≤ ρ{sub i}λ{sup −1} ≤ 1.60. Classical drift-diffusion transport along density and potential gradients is sufficient to describe flow profiles for most cases. For two parameter regimes (ρ{sub i}λ{sup −1} = 0.65 and 0.44), low-frequency electrostatic fluctuations (f < 10 kHz) and enhanced cross-field bulk ion flow to the boundary are observed.
We present a new approach to measure population densities of Ar I metastable and resonant excited states in low temperature Ar plasmas at pressures higher than 1 Torr. This approach combines the time resolved laser induced fluorescence technique with the kinetic model of Ar. The kinetic model of Ar is based on calculating the population rates of metastable and resonant levels by including contributions from the processes that affect population densities of Ar I excited states. In particular, we included collisional quenching processes between atoms in the ground state and excited states, since we are investigating plasma at higher pressures. We also determined time resolved population densities of Ar I 2 p excited states by employing optical emission spectroscopy technique. Time resolved Ar I excited state populations are presented for the case of the post-discharge of the supersonic flowing microwave discharge at pressures of 1.7 and 2.3 Torr. The experimental set-up consists of a pulsed tunable dye laser operating in the near infrared region and a cylindrical resonance cavity operating in TE{sub 111} mode at 2.45 GHz. Results show that time resolved population densities of Ar I metastable and resonant states oscillate with twice the frequency of the discharge.
Laser-induced fluorescence (LIF) of high-purity fused silica irradiated by ArF excimer laser is studied experimentally. LIF bands of the fused silica centered at 281 nm, 478 nm, and 650 nm are observed simultaneously. Furthermore, the angular distribution of the three fluorescence peaks is examined. Microscopic image of the laser modified fused silica indicates that scattering of the generated fluorescence by laser-induced damage sites is the main reason for the angular distribution of LIF signals. Finally, the dependence of LIF signals intensities of the fused silica on laser power densities is presented. LIF signals show a squared power density dependence, which indicates that laser-induced defects are formed mainly via two-photon absorption processes.
The Bohm sheath criterion is studied with laser-induced fluorescence in three ion species plasmas using two tunable diode lasers. Krypton is added to a low pressure unmagnetized DC hot filament discharge in a mixture of argon and xenon gas confined by surface multi-dipole magnetic fields. The argon and xenon ion velocity distribution functions are measured at the sheath-presheath boundary near a negatively biased boundary plate. The potential structures of the plasma sheath and presheath are measured by an emissive probe. Results are compared with previous experiments with Ar–Xe plasmas, where the two ion species were observed to reach the sheath edge at nearly the same speed. This speed was the ion sound speed of the system, which is consistent with the generalized Bohm criterion. In such two ion species plasmas, instability enhanced collisional friction was demonstrated [Hershkowitz et al., Phys. Plasmas 18(5), 057102 (2011).] to exist which accounted for the observed results. When three ion species are present, it is demonstrated under most circumstances the ions do not fall out of the plasma at their individual Bohm velocities. It is also shown that under most circumstances the ions do not fall out of the plasma at the system sound speed. These observations are also consistent with the presence of the instabilities.
We have proposed Laser Induced Fluorescence analysis using Doppler Shift of laser ablated atoms for Isotope Analysis (LIF-DS-IA). This isotope analysis is expected to have a small mass discrimination effect because the detection target is fluorescence photons instead of ions, which distort the measured isotope ratio by the space charge effect. We demonstrate this technique to be feasible through the model calculations. We experimentally confirmed the fundamental behavior in LIF-DS-IA that the shift in the irradiating laser frequency corresponds to that of peak position in the time domain LIF spectra. The reason of poor mass resolution in the present system was considered to be inadequate definition in the field of view of the fluorescence detector.
We report experimental observation of ion heating and subsequent development of a prominent ion temperature gradient in the core of a linear magnetized plasma device, and the controlled shear de-correlation experiment. Simultaneously, we also observe the development of strong sheared flows at the edge of the device. Both the ion temperature and the azimuthal velocity profiles are quite flat at low magnetic fields. As the magnetic field is increased, the core ion temperature increases, producing centrally peaked ion temperature profiles and therefore strong radial gradients in the ion temperature. Similarly, we observe the development of large azimuthal flows at the edge, with increasing magnetic field, leading to strong radially sheared plasma flows. The ion velocities and temperatures are derived from laser induced fluorescence measurements of Doppler resolved velocity distribution functions of argon ions. These features are consistent with the previous observations of simultaneously existing radially separated multiple plasma instabilities that exhibit complex plasma dynamics in a very simple plasma system. The ion temperature gradients in the core and the radially sheared azimuthal velocities at the edge point to mechanisms that can drive the multiple plasma instabilities, that were reported earlier.
Laser-Induced Fluorescence (LIF) spectroscopy is an essential tool for probing ion and atom velocity distribution functions (VDFs) in complex plasmas. VDFs carry information about the kinetic properties of species that is critical for plasma characterization. Accurate interpretation of these functions is challenging due to factors such as multicomponent distributions, broadening effects, and background emissions. Our research investigates the use of Wavelength Modulation (WM) LIF to enhance the sensitivity of VDF measurements. Unlike standard Amplitude Modulation (AM) methods, WM–LIF measures the derivative of the LIF signal. This approach makes variations in VDF shape more pronounced. VDF measurements with WM–LIF were investigated with both numerical modeling and experimental measurements. The developed model enables the generation of both WM and AM signals, facilitating comparative analysis of fitting outcomes. Experiments were conducted in a weakly collisional argon plasma with magnetized electrons and non-magnetized ions. Measurements of the argon ion VDFs employed a narrow-band tunable diode laser, which scanned the 4p 4 D 7/2 –3d 4 F 9/2 transition centered at 664.553 nm in vacuum. A lock-in amplifier detected the second harmonic WM signal, which was generated by modulating the laser wavelength with an externally controlled piezo-driven mirror of the diode laser. Finally, our findings indicate that the WM–LIF signal is more sensitive to fitting parameters, allowing for better identification of VDF parameters such as the number of distribution components, their temperatures, and velocities. In addition, WM–LIF can serve as an independent method to verify AM measurements and is particularly beneficial in environments with substantial light noise or background emissions, such as those involving thermionic cathodes and reflective surfaces.
Here, in this work, we report an annular beam confocal laser-induced fluorescence (LIF) configuration, which allows for high spatial resolution measurements of plasma properties in plasma setups and sources with limited optical access. The proposed LIF configuration utilizes the annular laser beam generated by a pair of diffractive axicons. The LIF signal is collected along the main optical axis within the ring region. It is shown experimentally that at a focal distance of 300 mm, a spatial resolution of ~5.3 mm can be achieved. Using geometric optics estimations, we showed that ~1 mm resolution at the same focal distance could potentially be achieved by modifying laser beam parameters. This approaches the localization accuracy of conventional LIF collection methods (with crossing laser beam injection and fluorescence collection optical paths). Measurements of the ion velocity distribution function in an argon plasma using both the confocal LIF with an annular laser beam and conventional LIF demonstrate a satisfactory agreement. The proposed LIF setup has potential applications for diagnostics in various plasma processing equipment and plasma sources, such as hollow cathodes, microplasmas, electric propulsion, etc.
We present measurements of ion velocity distribution profiles obtained by laser induced fluorescence (LIF) on an explosive laser produced plasma. The spatiotemporal evolution of the resulting carbon ion velocity distribution was mapped by scanning through the Doppler-shifted absorption wavelengths using a tunable, diode-pumped laser. The acquisition of these data was facilitated by the high repetition rate capability of the ablation laser (1 Hz), which allowed for the accumulation of thousands of laser shots in short experimental times. By varying the intensity of the LIF beam, we were able to explore the effects of fluorescence power against the laser irradiance in the context of evaluating the saturation vs the non-saturation regime. The small size of the LIF beam led to high spatial resolution of the measurement compared to other ion velocity distribution measurement techniques, while the fast-gate operation mode of the camera detector enabled the measurement of the relevant electron transitions.
Laser-induced fluorescence (LIF) and attenuated total reflectance Fourier transform infrared (ATR-FTIR) spectroscopy has been applied for the nondestructive, label free, and rapid analyses of the impact of copper (25, 50, and 75 μM) on maize seedlings at an early stage before the changes appear visually on the plant. The LIF measurement has been used to detect the signs of stress in the photosynthetic pigment. The integrated areal intensity and increasing fluorescence intensity ratios indicate decrease in the photosynthetic pigments in the leaves of maize plants stressed with copper. The ATR-FTIR technique has been utilized to estimate the changes arising in the cell wall polysaccharides, amino acid, secondary structure of protein and lipid content of the leaves of control and copper-treated maize seedlings. The second derivative and curve fitting analyses have been applied for the enhancement of the spectral variations and quantitative estimation of the changes arising in the biochemical profile. The result shows an increase in the pectin, lignin, amino acid, and protein content and reduction in the amount of cellulose and lipid in the leaves of maize seedlings due to the treatment of copper. This study indicates the toxic response of copper by hampering the growth and reduction in the photosynthetic pigments and biochemical content of the maize seedlings. This study also demonstrates the feasibility of the spectroscopic techniques (LIF and ATRFTIR) as a rapid, label free, and nondestructive probe for the assessment of stress and monitoring of crops.
Laser-induced fluorescence (LIF) measurements have been performed for the first time in a low temperature (T{sub e}{approx_equal}0.6 eV) Xe plasma using a tunable diode laser in the visible range of wavelengths. The transition in Xe II involved the ({sup 3}P{sub 1})5d[3]{sub 7/2} metastable state and the excitation wavelength was found to be 680.570{+-}0.001 nm (air). LIF measurements of I{sub 2} in a room temperature iodine gas cell were used to monitor the wavelength of the laser during the measurements.
The first laser-induced fluorescence measurements of ion acoustic wave reflection are presented. The experiment is performed in a multi-pole cylindrical chamber using a singly ionized argon (ArII) plasma produced by means of a hot cathode. Ion-acoustic waves are launched from a mesh antenna and reflected/absorbed by a biased, solid boundary (electrode). A comparison between the Langmuir probe and laser-induced fluorescence diagnostics is presented, with complementary Electric-field probe measurements.
Self-guided ultrafast laser filaments are a promising method for laser beam delivery and plasma generation for standoff and remote detection of elements and isotopes via filament-induced breakdown spectroscopy (FIBS). Yet, there are several challenges associated with the practical application of FIBS, including delivery of sufficient laser energy at the target for generating plasma with a copious amount of emission signals for obtaining a high signal-to-noise ratio. Here, in this study, we use laser-induced fluorescence (LIF) to boost the emission signal and reduce self-reversal in the spectral profiles. Ultrafast laser filaments were used to produce plasmas from an Al 6061 alloy target at various standoff distances from 1 to 10 m. For LIF emission enhancement, a narrow linewidth continuous-wave laser was used in resonance with a 394.40 nm Al I resonant transition, and the emission signal was monitored from the directly coupled transition at 396.15 nm. Emission signal features of Al I are significantly enhanced by resonant excitation. In addition, LIF of filament ablation plumes reduces the self-reversal features seen in the thermally excited spectral profiles. Time-resolved two-dimensional fluorescence spectroscopy was performed for evaluating the optical saturation effects, which are found to be non-negligible due to high Al atomic densities in the filament-produced plasmas.
We performed simultaneous measurement of absorption, emission, and laser-induced fluorescence spectroscopic signatures for determining nanosecond and femtosecond laser-produced plasma’s physical properties throughout its lifecycle. Plasmas are produced by focusing either ~6 ns, 1064 nm pulses from an Nd:YAG or ~35 fs, ~800 nm pulses from a Ti:Sapphire laser on an Inconel target that contains Al as a minor alloying addition. A continuous-wave narrowband tunable laser was used for performing absorption and fluorescence spectroscopy while a fast-gated detection system was used for emission spectroscopy. The temporal evolution of emission, fluorescence, and absorbance of Al transitions are compared for both ns and fs laser-produced plasms. Time-resolved absorbance was also used for evaluating linewidth, lineshape, temperature, and column-averaged atomic number density at late times of ns and fs plasma evolution. Our results demonstrate that lower and excited-state populations of fs laser produced plasmas are short-lived in comparison to those in ns plasmas. The lower state population is observed to reach a maximum value earlier in time for the fs plasma versus the ns plasma, while the kinetic temperature for the ns plasma was higher than for the fs plasma at most times of the plasma evolution.