Search NASA⌕ Search

SEARCH · Search NASA

Results for “Laser lamp”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Local Resistance Profiling of Ultra-Shallow Junction with Spike Lamp and Laser Annealing Using Scanning Spreading Resistance Microscopy

Local resistance profiles of ultra-shallow arsenic implanted into silicon with an energy of 3.5 keV and a dose of 1.2x10{sup 15} ions/cm{sup 2} activated by conventional spike lamp and laser annealing were measured by SSRM in a nitrogen atmosphere with a depth resolution of less than 10 nm for investigating the combination of the conventional spike lamp and laser annealing. Spike lamp annealing at 1050 deg. C followed by laser annealing at a power density of 0.42 kW/mm{sup 2} was found to give the lowest sheet resistance. The resistance profiles obtained by SSRM also indicated the lowest resistance for the sample after spike lamp annealing at 1050 deg. C followed by laser annealing with a power density of 0.42 kW/mm{sup 2}. Laser annealing alone with a power density of 0.42 kW/mm{sup 2} resulted in the higher sheet resistance, though the shallower resistance profile could be obtained. Spike lamp annealing followed by laser annealing procedures are effective in activating shallow arsenic profiles.

36 MATERIALS SCIENCE↗

Laser radar for spacecraft guidance applications

A flight qualified laser radar called LAMP (LAser MaPper) is under development at JPL. LAMP is a guidance and control sensor that can form 3 dimensional images of its field of regard. This paper describes the detailed design of the LAMP sensor.

LAMP laser radar laser range finder↗

Local Resistance Profiling of Ultra Shallow Junction Annealed with Combination of Spike Lamp and Laser Annealing Processes using Scanning Spreading Resistance Microscope

Local resistance profiles of ultra shallow boron and arsenic implanted into silicon with energies of 2.0 and 4.0 keV and doses of 2.0x10{sup 15} and 1.0x10{sup 15} ions/cm{sup 2} activated by a combination of conventional spike lamp and laser annealing processes were measured by scanning spreading resistance microscope (SSRM) with a depth resolution of less than 10 nm. The lowest local resistance at the low resistance region in 2.0 keV boron implanted silicon with 1050 deg. C spike lamp annealing followed by 0.35 kW/mm{sup 2} laser annealing was half of that without laser annealing. The lowest local resistance at the low resistance region in the arsenic implanted silicon activated by 1050 deg. C spike lamp annealing followed by 0.39 kW/mm{sup 2} laser annealing was 74% lower than that followed by 0.36 kW/mm{sup 2} laser annealing. The lowest local resistances at the low resistance regions in the arsenic implanted silicon with 0.36 and 0.39 kW/mm{sup 2} laser annealing followed by 1050 deg. C spike lamp annealing were 41 and 33% lower than those with spike lamp annealing followed by laser annealing. Laser annealing followed by spike lamp annealing could suppress the diffusion of the impurities and was suitable for making the ultra shallow and low resistance regions.

36 MATERIALS SCIENCE↗

Blackbody absorption efficiencies for six lamp pumped Nd laser materials

Utilizing high resolution spectra, the absorption efficiencies for six Nd laser materials were calculated as functions of the effective blackbody temperature of the lamp and laser crystal size. The six materials were Nd:YAG, Nd:YLF, Nd:Q-98 Glass, Nd:YVO4, Nd:BEL, and Nd:Cr:GSGG. Under the guidelines of this study, Nd:Cr:GSGG's absorption efficiency is twice the absorption efficiency of any of the other laser materials.

Cross, Patricia L.↗

Efficient wide-aperture neodymium glass rod amplifiers

Amplifiers based on neodymium phosphate glass rods 60 - 100 mm in diameter are experimentally studied. The amplifiers are pumped by INP-16/250 tubular flash lamps placed in a universal pump cavity with a two-section mirror reflector. A compact high-voltage capacitive energy storage with a preionisation circuit was developed to supply the lamps. (lasers)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Lidar for Guidance of a Spacecraft or Exploratory Robot

A report describes the Laser Mapper (LAMP) -- a lightweight, compact, low-power lidar system under development for guidance of a spacecraft or exploratory robotic vehicle (rover) at Mars or another planet. The LAMP is intended especially for use during rendezvous of two spacecraft in orbit, for mapping terrain during descent and landing of a spacecraft, for capturing a sample that has been launched into orbit, or navigation and avoidance of obstacles by a rover traversing terrain. The LAMP includes a laser that emits high-power, short light pulses. The laser beam is aimed in azimuth and elevation by use of a mirror on a two-axis gimbal, which scans the beam across a field of regard. Light reflected by a target is collected by a telescope, and the distance to the target is determined by measuring the round-trip travel time for reflected light pulses. The distance information is combined with directional information to construct a three-dimensional map of targets in the field of regard.

Liebe, Carl Christian↗

Lamp pumped Nd:YAG laser. Space-qualifiable Nd:YAG laser for optical communications

Results are given of a program concerned with the design, fabrication, and evaluation of alkali pump lamps for eventual use in a space qualified Nd:YAG laser system. The study included evaluation of 2mm through 6mm bore devices. Primary emphasis was placed upon the optimization of the 4mm bore lamp and later on the 6mm bore lamp. As part of this effort, reference was made to the Sylvania work concerned with the theoretical modeling of the Nd:YAG laser. With the knowledge gained, a projection of laser performance was made based upon realistic lamp parameters which should easily be achieved during following developmental efforts. Measurements were made on the lamp performance both in and out of the cavity configuration. One significant observation was that for a constant vapor pressure device, the spectral and fluorescent output did not vary for vacuum or argon environment. Therefore, the laser can be operated in an inert environment (eg. argon) with no degradation in output. Laser output of 3.26 watts at 430 watts input was obtained for an optimized 4mm bore lamp.

Ward, K. B.↗

Laser head for simultaneous optical pumping of several dye lasers

The invention is a laser head for simultaneous pumping several dye lasers with a single flash lamp. The laser head includes primarily a multi-elliptical cylinder cavity with a single flash lamp placed along the common focal axis of the cavity and with capillary tube dye cells placed along each of the other focal axes of the cavity. The inside surface of the cavity is polished. Hence, the single flash lamp supplies the energy to the several dye cells.

Mumola, P. B.↗

Investigation of light source and scattering medium related to vapor-screen flow visualization in a supersonic wind tunnel

Methods for increasing the radiant in light sheets used for vapor screen set-ups were investigated. Both high-pressure mercury arc lamps and lasers were considered. Pulsed operation of the air-cooled 1-kW lamps increased the light output but decreased reliability. An ellipsoidal mirror improved the output of the air-cooled lamps by concentrating the light but increased the complexity of the housing. Water-cooled-4-kW lamps coupled with high-aperture Fresnel lenses provided reasonable improvements over the air-cooled lamps. Fanned laser beams measurements of scattered light versus dew point made in conjunction with successful attempts to control the fluid injection. A number of smoke generators are described and test results comparing smoke and vapor screens are shown. Finally, one test included a periscope system to relay the image to a camera outside the flow.

Snow, W. L.↗

High-sensitivity electronic Stark spectrometer featuring a laser-driven light source

We report developmental details of a high-sensitivity Stark absorption spectrometer featuring a laser-driven light source. The light source exhibits intensity fluctuations of ~0.3% over timescales ranging from 1 min to 12 h, minimal drift (≤0.1%/h), and very little 1/f noise at frequencies greater than 200 Hz, which are comparable to or better than an arc-driven light source. Additional features of the spectrometer include balanced detection with multiplex sampling, which yielded lower noise in A, and constant wavelength or wavenumber (energy) spectral bandpass modes. We achieve noise amplitudes of ~7 × 10 –4 and ~6 × 10 –6 in measurements of single A and ΔA spectra (with 92 data points) taking ~7 and ~19 min, respectively.

47 OTHER INSTRUMENTATION↗

APT Flash Lamps for a New Laser at LLNL Memo

Each flashlamp is supported coaxially within a pyrex water-jacket tube by two identical connector assemblies, one at each end. These connector assemblies not only support the flashlamp mechanically, but also provide source and return pathways for flashlamp DI cooling water and for electrical current. At each end of the flashlamp, the (presumably) tungsten feed-through rod that supports the electrode is attached to a connector assembly through a Multilam fitting. O rings seated on the outside of each connector assembly form a water-tight seal between the connector assembly and the inside of the pyrex water-jacket tube. During operation, DI cooling water enters the tube located at the end of one of the connectors, flows over that connector’s Multilam fitting, flows through a ring of holes in the connector assembly and then flows into the 1-mm gap between the flashlamp and the pyrex water-jacket tube. After passing over the length of the flashlamp, the water flows through the connector assembly at the opposite end of the flashlamp and exits through that connector assembly’s end tube. Electrical pulses are delivered to the flashlamp through the tubes coming out of the connector assemblies.

42 ENGINEERING↗

Diode laser-pumped solid-state lasers

An evaluation is made of the consequences for solid-state lasers of novel diode laser-pumping technology. Diode laser-pumped neodymium lasers have operated at an electrical-to-optical efficiency of 10 percent in a single spatial mode, with linewidths of less than 10 kHz, and with a spectral power brightness sufficiently great to allow frequency extension by harmonic generation in nonlinear crystals; this has yielded green and blue sources of coherent radiation. Q-switched operation with kW peak powers and mode-locked operation with 10-picosec pulse widths have also been demonstrated. All-solid-state lasers at prices comparable to those of current flash-lamp-pumped laser systems are foreseen, as are power levels exceeding 1 kW, for coherent radar, global satellite sensing, and micromachining.

Byer, Robert L.↗

Improvement in Suppression of Pulsed Nd:YAG Laser Light With Iodine Absorption Cells for Filtered Rayleigh Scattering Measurements

Filtered Rayleigh scattering using iodine absorption cells is an effective technique for obtaining density, temperature, and velocity measurements in high speed confined flows. By tuning a single frequency laser to a strong iodine absorption line, stray scattered laser light can be greatly suppressed. For example, the minimum transmission predicted by an iodine absorption model calculation is less than 10(exp -5) at the 18788.44/cm line using a 200 mm absorption cell containing iodine vapor at 0.46 T. Measurements obtained by other researches using a CW Nd:YAG laser agree with the model calculations. However, measurements made by us and by others using Q-switched, injection-seeded, frequency doubled Nd:YAG lasers only show minimum transmission of about 3 x 10(exp -3). This greatly reduces the applicability of the filtered Rayleigh scattering technique using these lasers in experiments having large amounts of stray scattered laser light. The purposes of the present study are to characterize the spectrum of the excess light transmitted by the iodine cell and to make changes to the laser to reduce the transmitted laser light. Transmission data as a function of laser frequency for the iodine absorption line at 18788.44/cm are presented. A planar mirror Fabry-Perot interferometer was used to characterize the frequency spectrum of the light passed through the cell. Measurements taken with the laser tuned to the center of the iodine absorption line show the light transmitted through the iodine cell to have a component with a bandwidth of about 40 GHz. This is probably caused by other modes in the laser that exist in spite of the single frequency injection beam. A second broadband component was also observed, possibly caused by the laser flash lamps or by fluorescence. An intracavity etalon was installed in the laser oscillator cavity to suppress the 40 GHz component. Measurements taken with the etalon tuned to the injection frequency showed a reduction in the transmitted laser light. This improvement allows the iodine cell to block significantly more of the stray laser light in filtered Rayleigh scattering experiments. Examples are given of filtered Rayleigh scattering measurements showing the effect of the etalon on measurements taken in a Mach 3 flow in the NASA Lewis 4 inch by 10 inch supersonic wind tunnel.

Seasholtz, Richard G.↗

Global Light System for JEM-EUSO

The Global Light System (GLS) is a network of ground-based Xenon flash lamps and steered UV lasers to validate the key functions of the JEM-EUSO instrument. These functions include triggering efficiency, the accuracy of intrinsic luminosity measurements, and the reconstructed pointing direction accuracy. GLS units will generate benchmark optical signatures in the atmosphere with similar characteristics to the optical signals of cosmic ray EASs. The lasers will generate tracks and the flashers will generate point flashes. But unlike air showers, the number, energy, precise time, direction (lasers) can be specified. JEM-EUSO will reconstruct the pointing directions of the lasers and the energy of the lasers and flash lamps to monitor the detector's triggers, and accuracy of energy and direction reconstruction. 12 GLS units will be deployed at selected sites around the globe. The JEM-EUSO footprint will pass over a GLS unit on average once per (near) moonless night under clear conditions for appropriately selected sites. The 12 units will be supplemented by campaign style measurements with an airborne unit that will be flown over the open ocean at selected altitudes under JEM-EUSO. A GLS prototype in an airplane will support a high-altitude balloon flight in 2014 of a proto-type JEM-EUSO telescope. We will describe the concept and system design and report on the status of prototyping and the selection process for candidates sites.

Christl, Mark↗

First results on Ge resonant laser photoionization in hollow cathode lamp

In the framework of the research and development activities of the SPES project regarding the optimization of the radioactive beam production, a dedicated experimental study has been recently started in order to investigate the possibility of in-source ionization of germanium using a set of tunable dye lasers. Germanium is one of the beams to be accelerated by the SPES ISOL facility, which is under construction at Legnaro INFN Laboratories. The three-step, two color ionization schemes have been tested using a Ge hollow cathode lamp. The slow and the fast optogalvanic signals were detected and averaged by an oscilloscope as a proof of the laser ionization inside the lamp. As a result, several wavelength scans across the resonances of ionization schemes were collected with the fast optogalvanic signal. Some comparisons of ionization efficiency for different ionization schemes were made. Furthermore, saturation curves of the first excitation transitions have been obtained. This investigation method and the setup built in the laser laboratory of the SPES project can be applied for the photo-ionization scheme studies also for the other possible radioactive elements.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Dye laser traveling wave amplifier

A flash lamp pumped dye laser suitable for use as an amplifier stage was developed. The desired output laser pulses are of nanosecond duration, tunable in center frequency, and of good optical quality. Its usefulness as a laser oscillator is emphasized, because it constitutes a compact, relatively efficient source of tunable dye laser light.

Davidson, F.↗

Determination of particle size using measurement of scatter

Scatter from glass beads placed on a mirror was measured using a quartz lamp and laser. Data were obtained in the plane containing the normal to the surface and the incident beam. For the quartz lamp the best correlation can be obtained for data measured at a zenith of 55 deg and 180 deg from the incident beam. The best correlation when the laser is used is obtained at about the same position. However, the correlation variables are angular spacing of the minimums of the data versus the size. Whereas, with the quartz lamp the correlation variables are the amount of scattered energy versus size.

Scott, R. L., Jr.↗