Search NASASearch

SEARCH · Search NASA

Results for “Leak Test”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

NASA-STD-7012 Leak Test Requirements: Potential Reference for ASNT Nondestructive Testing Handbook for Leak Testing

Developed in 2018-2019, NASA-STD-7012 Leak Test Requirements, has been drafted based mostly on the NASA technical requirement documents applicable to the International Space Station (ISS) hardware and payloads that were developed over the years taking into consideration many known references such as Leakage Testing Handbook prepared by General Electric for the Jet Propulsion Laboratory, the ASTM International standards for leak testing, and last, but not least, the ASNT Nondestructive Testing Handbook for Leak Testing. Thus, NASA-STD-7012 has a reference to the above-mentioned handbook in the leak test method/technique descriptions. However, there are some technical details that are described differently in NASA standard and ASNT Handbook. Those technical details are mostly related to the classification of the leak test methods/techniques, and also to tracer gas to working fluid (gas or liquid) leakage rate conversion methodology, and to some definitions used in the text of both NASA standard and ASNT Handbook. Those differences are going to be briefly described in this paper to let ASNT leak test experts decide if they want to refer to NASA-STD-7012 while working on the next edition of the ASNT Handbook, Volume 2 for Leak Testing.

Lvovsky, Oleg M.

Fitting Leak Test Report: Ground-Based Cryogenic Leak Test of Fittings for Cryogenic Fluid Management

EXECUTIVE SUMMARY Mechanically connected joints used in cryogenic fluid lines as part of space flight elements need to survive launch vibrations and remain leak-free to minimize the loss of on-board commodity and hazardous gas accumulation. In 2020, a cryogenic test apparatus was developed which can evaluate the leak performance of pressurized threaded fluid fittings. The fittings were mounted in the TVAC and cooled to cryogenic test temperature and pressurized with helium while the leak rate was measured using a calibrated GHe leak detector. The test articles for the initial proof of concept testing were ¼ and 1 inch Swagelok VCR fittings with three different types of seal rings copper, nickel, and Ni. Each fitting configuration (size/seal material) was subjected to two consecutive cryogenic thermal cycles, followed by exposure to a launch vibration profile at ambient temperature, after which two additional TVAC cycle tests were performed. The testing reported here is a continuation of the 2020 tests with a statistically significant large number of samples and test runs. Three Swagelok VCR fitting sizes were tested ¼, ½ and 1 inch, and five (5) samples of each fitting size, each sample was tested with SST and Ni seal rings (Total of 30 unique test articles). Each test article was subjected to four (4) thermal cycles. Half of these cycles were performed before vibration testing and half were performed after vibration testing. The vibration testing was performed to evaluate the ability of the fittings to survive launch-type vibration profiles and remain leak-free. Leak checking of each fitting was completed at temperatures between 20K – 30K. The test procedure in Section 8.0 was designed to facilitate a qualification test program by allowing a higher test throughput rate coupled with repeatable test profiles. Results were very positive and show that out of the 30 samples they all passed with leak rates a factor of 2-3 lower than the established 10-6sccs GHe leak threshold. The result showed the Ni seals had lower leak rate, but the SST was more rugged. There were two deviations where damage to the Ni seal ring during assembly resulted in a leaky fitting, this is discussed in Section 10.7 Test Deviations. These fittings show great promise for space flight use and further testing is recommended to fully qualify the fittings per the ASTM F1387-19 and/or other relevant NASA specifications. The test equipment hardware and software capability developed for this testing is generic and not restricted to VCR fittings. It can be employed to evaluate/qualify the leak performance of other types of fittings and a wide range of other cryogenic fluid components such as valves, gages, connectors, etc.

Cryogenic

Leak testing

Leak-testing methods for gas and liquid systems are described. The physical principles of molecular, liquid, and gas flow; relations of leak-testing methods and instrumentation; and tracer gases used in testing vacuum systems are discussed.

Engelhardt, R. E.

Orifice leak test

Orifice leak test for electronic components hermeticity

Altshuler, T. L.

Mass-Flow-Meter Leak-Testing System

Improved leak-testing system incorporates mass-flow meter as primary sensor for measurement of leakage rate. System easier to use and more reliable and enables leak tests to be completed in less time. Produces test data more plentiful, more accurate, and better suited to leak detection and diagnosis. Operates over range of test conditions, including pressures from atmospheric to 1,000 psi, temperatures from 50 to 120 degrees F and volumes from less than 1 in.(sup3) to 22 in.(sup3). Sensitive enough to measure absorbed gas seeping from O-ring seals after test pressure released.

Sorensen, Eric B.

Filter Efficiency and Leak Testing of Returned ISS Bacterial Filter Elements After 2.5 Years of Continuous Operation

The atmosphere revitalization equipment aboard the International Space Station (ISS) and future deep space exploration vehicles provides the vital functions of maintaining a habitable environment for the crew as well as protecting the hardware from fouling by suspended particulate matter. Providing these functions are challenging in pressurized spacecraft cabins because no outside air ventilation is possible and a larger particulate load is imposed on the filtration system due to lack of sedimentation in reduced gravity conditions. The ISS Environmental Control and Life Support (ECLS) system architecture in the U.S. Segment uses a distributed particulate filtration approach consisting of traditional High-Efficiency Particulate Adsorption (HEPA) filters deployed at multiple locations in each module. These filters are referred to as Bacteria Filter Elements (BFEs). As more experience has been gained with ISS operations, the BFE service life, which was initially one year, has been extended to two to five years, dependent on the location in the U.S. Segment. In previous work we developed a test facility and test protocol for leak testing the ISS BFEs. For this work, we present results of leak testing a sample set of returned BFEs with a service life of 2.5 years, along with particulate removal efficiency and pressure drop measurements. The results can potentially be utilized by the ISS Program to ascertain whether the present replacement interval can be maintained or extended to balance the on-ground filter inventory with extension of the lifetime of ISS to 2024. These results can also provide meaningful guidance for particulate filter designs under consideration for future deep space exploration missions.

ISS Air Quality

Temporary Sealing of Cavities for Leak Testing

Wax Seals cavity openings to permit helium leak test of cavity welds. Technique facilitates leak testing of cavities in components of larger systems not otherwise sealed off at time leak testing done.

Little, J.

Cryogenic leak testing of tube fittings/valves

A high pressure and variable temperature cryogenic leak testing system was conceived and designed in order to conduct leakage testing of pipe fittings/valves in liquid hydrogen supply lines of the Space Shuttle. The system can create a continuous testing environment of variable temperature, 5.5 to about 300 K, and variable pressure, 0.01 to about 70 x 10 exp 5 Pa, with a large sample space, 90 mm diameter x 228 mm length, and at low operating cost. In terms of cryogenic leak testing the system has a special capability for extensive applications. The system comprised a variable temperature cryostat, a high pressure sample chamber, a vacuum pumping station, gas flow control system, pressure and temperature control systems, and leak detecting and measuring systems. A general discussion of cryogenic leak testing methods is also presented.

Jia, L. X.

HELIUM LEAK TEST MODELING OF A SPENT NUCLEAR FUEL CANISTER

The U.S. Department of Energy (DOE) is considering the development of one or more federal consolidated interim storage facilities (CISFs) to be used to store commercial spent nuclear fuel (SNF) at locations in the U.S. One of the first technical challenges of a CISF is performing an inspection of SNF canisters upon their receipt to confirm they can be placed into the CISF’s licensed storage configuration. The canister receipt inspection is critical to CISF site operations. The test is conceived as being a helium (He) leak check, intended to confirm that the confinement boundary of a SNF canister is intact. SNF canisters are filled with He when they are sealed, so detection of a He leak indicates that a through-wall flaw has occurred in the canister confinement boundary. Other measurements are planned to occur upon canister receipt in addition to the He leak check such as krypton-85 measurements, which would indicate confinement breaches of one or more fuel rods in addition to a breach of the SNF canister. However, the He leak check has been identified as one of such high importance and has such significant technical challenges that a full-scale demonstration is needed to confirm the He leak test’s viability and to assist in planning relative to its operational requirements. A modeling methodology for simulating the He detection test was developed to help inform the test plan and the design of the test vessels. To develop the modeling methodology a detailed computational fluid dynamics (CFD) benchmark model was constructed to compare against leak rate test data from a transportation package for radioactive material. This report is focused on modeling efforts to simulate the benchmark leak test.

Suffield, Sarah R.

Implementation of Leak Test Methods for the International Space Station (ISS) Elements, Systems and Components

The International Space Station (ISS has Qualification and Acceptance Environmental Test Requirements document, SSP 41172 that includes many environmental tests such as Thermal vacuum & Cycling, Depress/Repress, Sinusoidal, Random, and Acoustic Vibration, Pyro Shock, Acceleration, Humidity, Pressure, Electromatic Interference (EMI)/Electromagnetic Compatibility (EMCO), etc. This document also includes (13) leak test methods for Pressure Integrity Verification of the ISS Elements, Systems, and Components. These leak test methods are well known, however, the test procedure for specific leak test method shall be written and implemented paying attention to the important procedural steps/details that, if omitted or deviated, could impact the quality of the final product and affect the crew safety. Such procedural steps/details for different methods include, but not limited to: - Sequence of testing, f or example, pressurization and submersion steps for Method I (Immersion); - Stabilization of the mass spectrometer leak detector outputs fo r Method II (vacuum Chamber or Bell jar); - Proper data processing an d taking a conservative approach while making predictions for on-orbit leakage rate for Method III(Pressure Change); - Proper Calibration o f the mass spectrometer leak detector for all the tracer gas (mostly Helium) Methods such as Method V (Detector Probe), Method VI (Hood), Method VII (Tracer Probe), Method VIII(Accumulation); - Usage of visibl ility aides for Method I (Immersion), Method IV (Chemical Indicator), Method XII (Foam/Liquid Application), and Method XIII (Hydrostatic/Visual Inspection); While some methods could be used for the total leaka ge (either internal-to-external or external-to-internal) rate requirement verification (Vacuum Chamber, Pressure Decay, Hood, Accumulation), other methods shall be used only as a pass/fail test for individual joints (e.g., welds, fittings, and plugs) or for troubleshooting purposes (Chemical Indicator, Detector Probe, Tracer Probe, Local Vacuum Chamber, Foam/Liquid Application, and Hydrostatic/Visual Inspection). Any isolation of SSP 41172 requirements have led to either retesting of hardware or accepting a risk associated with the potential system or component pressure integrity problem during flight.

Underwood, Steve

Apparatus for Leak Testing Pressurized Hoses

A hose-attaching apparatus for leak-testing a pressurized hose may include a hose-attaching member. A bore may extend through the hose-attaching member. An internal annular cavity may extend coaxially around the bore. At least one of a detector probe hole and a detector probe may be connected to the internal annular cavity. At least a portion of the bore may have a diameter which is at least one of substantially equal to and less than a diameter of a hose to be leak-tested.

Underwood, Steve D.

Aerospace Payloads Leak Test Methodology

Pressurized and sealed aerospace payloads can leak on orbit. When dealing with toxic or hazardous materials, requirements for fluid and gas leakage rates have to be properly established, and most importantly, reliably verified using the best Nondestructive Test (NDT) method available. Such verification can be implemented through application of various leak test methods that will be the subject of this paper, with a purpose to show what approach to payload leakage rate requirement verification is taken by the National Aeronautics and Space Administration (NASA). The scope of this paper will be mostly a detailed description of 14 leak test methods recommended.

Lvovsky, Oleg

Fitting Leak Test Report

Many Human Landing System flight elements are anticipated to implement mechanically connected joints in cryogenic fluid lines to simplify system assembly. These joints will need to survive launch vibration, while cold, and remain as leak‐free as possible to minimize commodity loss. Threaded fluid fittings should be qualified for use in their expected environments to reduce risk and ensure mission success. A new ground‐based test apparatus was developed and validated to obtain quantifiable low leak rate test data for a small component, such as a pressurized threaded fluid fitting, while in the temperature range of liquid hydrogen. A cryocooler is used to attain the cold test temperature and helium leakage from a pressurized fitting mounted within a vacuum test chamber is measured using a mass spectrometer leak detector. Two different sizes of Swagelok VCR fittings with three different types of seal rings were selected as the test articles for the initial proof of concept testing. Each fitting configuration was subjected to two consecutive cryogenic thermal cycles and cold leak measurement tests, followed by exposure to a high vibration test profile at ambient temperature on a shaker table, and then two additional cold leak measurement tests. Very low leak rates, below the acceptable leak rate threshold, were measured at the pressures tested. Several enhancements to the test hardware are discussed that would facilitate a comprehensive fitting qualification test campaign by enabling a higher test throughput rate and ensuring a repeatable test profile.

Cryogenic Fluid Management

Leak test system

System for quantitative determination of leak rates in large pressurized compartments is described. Method uses pressure reference cylinder placed in thermal contact with internal environment of compartment. Construction of equipment and details of operational procedure are reported. Illustration of equipment is included.

Morris, R. G.