Search NASA⌕ Search

SEARCH · Search NASA

Results for “Level Control”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Calibration of V-Notch and Compound Weirs for Subsurface Drainage Water Level Control Structures

Highlights Accurate discharge estimation is important when evaluating edge-of-field conservation practices. V-notch weir equations were developed for three sizes of subsurface drainage water level control structures. Compound weir equations were developed for subsurface drainage water level control structures. The compound weir equation accurately estimates discharge for flows within and overtopping the V-notch. Abstract.Numerous edge-of-field conservation practices use subsurface drainage water level control structures to monitor water levels and estimate discharge. In a control structure, procedures for calculating discharge when flow depth (head) exceeds the V-notch depth and overflows in the rectangular portion of the compound weir (CW) are ambiguous. In this study, we developed calibration equations for V-notch weirs in Agri Drain inline water level control structures of different sizes for flows within the V-notch and overtopping flow events. The discharge equation for overtopping events (Q CW , L s -1 ) was determined as: Q CW = a 1 (h b1 -h 1 b1 )+a 2 (W e -W v )h 1 b2 , where h and h 1 are heads above vertex/bottom and top of V-notch (cm), respectively, W is the effective crest width of rectangular weir (cm), W v is the top width of V-notch (cm), a 1 and b 1 are parameters for V-notch weir obtained by calibration, and a 2 and b 2 are calibration parameters for rectangular weir obtained from literature. Results were compared with a weir equation available in the literature (Q V+R ), which combines a V-notch equation with a head equal to V-depth and a rectangular weir equation for flow above V-depth. Discharge at overflow was estimated with high accuracy with Q CW, whereas Q V+R underestimated discharge (e.g., PBIAS of 0.67% vs. 17.82% for a 15.2 cm structure). An example using Q V+R resulted in a 14% lower annual estimation of nitrate-N load diverted to a saturated buffer than Q CW due to underestimation of drainage discharge during overflow events. Results suggest that the developed equation (Q CW ) accurately estimates discharge and will thus improve the estimated N load compared to Q V+R . Keywords: Compound weir, Flow monitoring, Subsurface drainage, V-notch weir, Water level control structure, Weir calibration.

Agriculture↗

Supervisory-level control system demand control of an HVAC system

A supervisory-level control system is provided and includes a summation unit receptive of first and second signals, an HVAC system to generate the second signal according to first set-point signals and to a second set-point signal and a supervisory controller. The supervisory controller includes a control unit, a set-point scheduler and a zone level set-point distribution unit. The control unit is receptive of an error signal representing a difference between the first and second signals from the summation unit. The set-point scheduler is receptive of a demand signal generated by the control unit according to the error signal. The set-point scheduler generates a set-point command signal and the second set-point signal according to the demand signal. The zone level set-point distribution unit is configured to generate the first set-point signals in accordance with the set-point command signal.

Adetola, Veronica↗

Warrick Conductivity Level Controllers Series 3H

This is my internship poster. In the poster I talk about the level controllers that I wired together and installed to support electrolysis testing systems in efforts to make the systems more efficient and run based on the communication between devices to ensure a closed loop system that can run on its own in a safe and controlled manner. I included pictures of some of the wiring as well as the level sensor devices and relays. I also included pictures of the tanks that will be filled at different heights with deionized water based on where the level sensors are.

08 HYDROGEN↗

Control of passivation and compensation in Mg-doped GaN by defect quasi Fermi level control

A defect quasi Fermi level (dQFL) control process based on above bandgap illumination was applied to control H and V N -complexes, which are the main contributors to the passivation and self-compensation, respectively, in Mg:GaN grown via metalorganic chemical vapor deposition. Secondary ion mass spectrometry measurements confirmed that the total Mg incorporation was unaffected by the process. However, the total H concentration was reduced to similar levels obtained by post-growth thermal activation prior to any annealing treatment. Similarly, the 2.8 eV emission in the photoluminescence spectra, attributed to compensating V N and its complexes, was reduced for the dQFL-process samples. After thermal activation and Ni/Au contact deposition, Hall effect measurements revealed lower resistivities (increased mobilities and free hole concentrations) for dQFL-grown samples with Mg doping concentrations above and below 2 × 10 19 cm -3 . All these results demonstrate that the dQFL process can effectively reduce the H-passivation and self-compensation of the Mg:GaN films.

36 MATERIALS SCIENCE↗

Within-Host Phenotypic Evolution and the Population-Level Control of Chronic Viral Infections by Treatment and Prophylaxis

Chronic viral infections can persist for decades spanning thousands of viral generations, leading to a highly diverse population of viruses with its own complex evolutionary history. We propose an expandable mathematical framework for understanding how the emergence of genetic and phenotypic diversity affects the population-level control of those infections by both non-curative treatment and chemo-prophylactic measures. Our frameworks allows both neutral and phenotypic evolution, and we consider the specific evolution of contagiousness, resistance to therapy, and efficacy of prophylaxis. We compute both the controlled and uncontrolled, population-level basic reproduction number accounting for the within-host evolutionary process where new phenotypes emerge and are lost in infected persons, which we also extend to include both treatment and prophylactic control efforts. We used these results to discuss the conditions under which the relative efficacy of prophylactic versus therapeutic methods of control are superior. Finally, we give expressions for the endemic equilibrium of these models for certain constrained versions of the within-host evolutionary model providing a potential method for estimating within-host evolutionary parameters from population-level genetic sequence data.

sensitivity analysis↗

Increased Reliability for Near-Term Quantum Computers via Low-Level Control (CRADA Final Report)

This project helped narrow the gap between near-term hardware and practical applications of quantum computing through the development and implementation of optimized compilation and error mitigation techniques. These advances were enabled by low-level control available on the Advanced Quantum Testbed, and led to methods that characterized and improved the platform’s performance on quantum algorithms. Results of this work were published in the scientific literature and used to inform internal software development of partner Super.tech.

97 MATHEMATICS AND COMPUTING↗

Error-Level-Controlled Synthetic Forecasts for Renewable Generation

Renewable energy resources, including solar and wind energy, play a significant role in sustainable energy systems. However, the inherent uncertainty and intermittency of renewable generation pose challenges to the safe and efficient operation of power systems. Recognizing the importance of short-term (hours ahead) renewable generation forecasting in power systems operation, it becomes crucial to address the potential inaccuracies in these forecasts. To systematically evaluate the performance of controllers in the presence of imperfect forecasts, we generate synthetic forecasts using actual renewable generation profiles (one from solar and one from wind). These synthetic forecasts incorporate different levels of statistical error, allowing us to control and manipulate the accuracy of the predictions. The primary objective is to employ synthetic forecasts with controlled yet realistic error levels to systematically investigate how controllers adapt to variations in forecast accuracy, providing valuable insights into their robustness and effectiveness under real-world conditions.

Array↗

Investigation of Abnormal Level Control Oscillations in a BWR Feedwater System

In the long-term operation of nuclear power plants, the aging of systems, structures, and components can lead to maintenance issues that must be dealt with to maintain cost-effective plant operations. One common issue affecting the currently operated boiling water reactors is the onset of unexpected level oscillations in feedwater heaters. This phenomenon can cause excessive cycling of drain valves and lead to premature failures. In this work, we develop a dynamic model of a set of feedwater heaters to determine the root cause of oscillations observed in an operating plant. Simulation results of various transient scenarios were used to investigate the effects of the controller parameters, boundary conditions, and possible valve and instrument issues. The analysis led to the conclusion that the most likely causes of the observed self-sustained oscillations in the system are the nonlinear behaviors of the drain valve and the level transmitter induced by degraded equipment condition. In conclusion, a partial plug of the pressure line used for level sensing in the system can account for a significant deadtime in the level transmitter, a nonlinear effect shown to induce self-sustained oscillatory behaviors.

Boiling water reactors↗

Understanding Catalyst ‘Volcano’ Dependence Through Fermi-Level Controlled Kinetics Using Electronic Theory

The ubiquitous two-step Michaelis–Menten and Temkin–Boudart reaction mechanisms are extended to include the influence of the catalyst electronic subsystem in a 5-step mechanism. The resulting kinetic equation provides an alternative explanation for the well-known volcano-shaped dependence found in catalysis. The equilibrium constants of fast electronic steps are highlighted for their influence on adsorption and desorption through the relative concentration of charged versus neutral intermediates. This generalized concept can be widely applied to determine the optimal catalyst, based on the Fermi level of the material, for reactions proceeding via this universal reaction.

25 ENERGY STORAGE↗

Molecular-Level Control over Ionic Conduction and Ionic Current Direction by Designing Macrocycle-Based Ionomers

Poor ionic conductivity of the catalyst-binding, submicrometer- thick ionomer layers in energy conversion and storage devices is a huge challenge. However, ionomers are rarely designed keeping in mind the specific issues associated with nanoconfinement. Here, we designed nature-inspired ionomers (calix-2) having hollow, macrocyclic, calix[4]arene-based repeat units with precise, sub-nanometer diameter. In ≤100 nm-thick films, the in-plane proton conductivity of calix-2 was up to 8 times higher than the current benchmark ionomer Nafion at 85% relative humidity (RH), while it was 1-2 orders of magnitude higher than Nafion at 20-25% RH. Confocal laser scanning microscopy and other synthetic techniques allowed us to demonstrate the role of macrocyclic cavities in boosting the proton conductivity. The systematic self-assembly of calix-2 chains into ellipsoids in thin films was evidenced from atomic force microscopy and grazing incidence small-angle X-ray scattering measurements. Moreover, the likelihood of alignment and stacking of macrocyclic units, the presence of one-dimensional water wires across this macrocycle stacks, and thus the formation of long-range proton conduction pathways were suggested by atomistic simulations. We not only did see an unprecedented improvement in thin-film proton conductivity but also saw an improvement in proton conductivity of bulk membranes when calix-2 was added to the Nafion matrices. Nafion-calix-2 composite membranes also took advantage of the asymmetric charge distribution across calix[4]arene repeat units collectively and exhibited voltage-gating behavior. The inclusion of molecular macrocyclic cavities into the ionomer chemical structure can thus emerge as a promising design concept for highly efficient ion-conducting and ion-permselective materials for sustainable energy applications.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Population-level control of two manganese oxidases expands the niche for bacterial manganese biomineralization

Abstract The enzymatic oxidation of aqueous divalent manganese (Mn) is a widespread microbial trait that produces reactive Mn(III, IV) oxide minerals. These biominerals drive carbon, nutrient, and trace metal cycles, thus playing important environmental and ecological roles. However, the regulatory mechanisms and physiological functions of Mn biomineralization are unknown. This challenge arises from the common occurrence of multiple Mn oxidases within the same organism and the use of Mn oxides as indicators of combined gene activity. Through the detection of gene activation in individual cells, we discover that expression ofmnxGandmcoA, two Mn oxidase-encoding genes inPseudomonas putidaGB-1, is confined to subsets of cells within the population, with each gene showing distinct spatiotemporal patterns that reflect local microenvironments. These coordinated intra-population dynamics control Mn biomineralization and illuminate the strategies used by microbial communities to dictate the extent, location, and timing of biogeochemical transformations.

Biotechnology & Applied Microbiology↗

Solar PV and BESS Plant-Level Voltage Control and Interactions: Experiments and Analysis

In real world operation, low-frequency oscillations associated with plant-level voltage control of inverter-based resources (IBRs) have been a concern of grid operators. Here, this research aims to demonstrate and analyze the effect of plant-level voltage control on system stability and potential interactions among IBRs. The experiment results of a 13.2-kV system interconnected with two IBRs—a 1-MW battery energy storage system (BESS) and a 430-kW solar photovoltaic (PV) plant—are presented. Both 0.5-Hz and 3-Hz oscillations become visible at certain conditions. The phenomenon is further explained by use of a feedback system consisting of the plant-level droop control and the effect of reactive power or var injection on voltage. The main components of the block diagram are obtained via frequency scan measurements. The analysis offers an understanding of the main contributors and other influencing factors of the 3-Hz and 0.5-Hz modes. It also reveals the role of the volt-var droop gain, the low-pass filter time constant, and the system impedance in stability.

14 SOLAR ENERGY↗

A bi-level advanced control framework for large-scale control of buildings with system-level impact

Increased electricity consumption combined with new forms of generation is testing the reliability of our grid infrastructure. This work describes a method to improve the reliability of the grid through large-scale advanced building control. This paper develops a bi-level distributed control framework to shift the load of 153 buildings to achieve a system-level objective of tracking a power reference signal. This bi-level control is based on the previously-developed ANPV-MPC, a predictive controller that uses a Bayesian neural network to generate an accurate control model and adapt to changing conditions over time. By shifting the building electricity demand to better match the available power, the grid system supplying the buildings is more reliable as evidenced by the analysis of node voltages across an IEEE 13-bus distribution system. The proposed bi-level control framework tracks the system-level power reference with enough accuracy to regulate node voltages across the IEEE 13-bus distribution system within ANSI limits of ±5%. Additionally, the adaptive nature of ANPV-MPC allows each building across the system to adapt to changing conditions, further amplifying the system-level reliability.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Wood‐density has no effect on stomatal control of leaf‐level water use efficiency in an Amazonian forest

Forest disturbances increase the proportion of fast-growing tree species compared to slow-growing ones. To understand their relative capacity for carbon uptake and their vulnerability to climate change, and to represent those differences in Earth system models, it is necessary to characterise the physiological differences in their leaf-level control of water use efficiency and carbon assimilation. We used wood density as a proxy for the fast-slow growth spectrum and tested the assumption that trees with a low wood density (LWD) have a lower water-use efficiency than trees with a high wood density (HWD). We selected 5 LWD tree species and 5 HWD tree species growing in the same location in an Amazonian tropical forest and measured in situ steady-state gas exchange on top-of-canopy leaves with parallel sampling and measurement of leaf mass area and leaf nitrogen content. We found that LWD species invested more nitrogen in photosynthetic capacity than HWD species, had higher photosynthetic rates and higher stomatal conductance. Furthermore, contrary to expectations, we showed that the stomatal control of the balance between transpiration and carbon assimilation was similar in LWD and HWD species and that they had the same dark respiration rates.

54 ENVIRONMENTAL SCIENCES↗

Precise Motion Control of Hybrid Hydraulic Electric Architecture (HHEA)

Off-highway heavy-duty vehicles have been long-standing users of hydraulic systems for power transmission and control. However, traditional hydraulic systems suffer from significant energy losses which lead to increased operating costs and a larger carbon footprint due to higher CO2 emissions. Improving the efficiency of these mobile machines is crucial not only for reducing their environmental impact but also for saving billions of dollars in operating costs. Currently, the state-of-the-art Load Sensing Architecture uses throttling valves for control, which significantly reduces its efficiency and does not recuperate energy from over-running loads. Researchers have developed several architectures such as Common Pressure Rail systems, Displacement Control, STEAM, and Electrohydraulic Architecture to improve the efficiency of off-road mobile machines. However, each of these architectures has its drawbacks. To increase system efficiency and take advantage of electrification benefits, our research group has developed a novel Hybrid Hydraulic-Electric Architecture (HHEA). The HHEA can significantly improve efficiency, decrease the size of electrical components, and maintain control performance. This new architecture has the potential to revolutionize the off-highway mobile machine industry and lead to a more sustainable future. The HHEA uses a set of common pressure rails to provide the majority of power to the actuators via power-dense hydraulics and uses electric motors for precise control and power modulation. In the context of off-road mobile machines, energy savings are undoubtedly important but it is equally important to consider the machines’ ability to perform tasks with precision and accuracy according to given commands. Therefore, precise motion control is of utmost importance to maintain the utility of Hybrid Hydraulic-Electric Architecture (HHEA). The HHEA presents a unique challenge to motion control due to the discrete pressure changes that occur when the system switches between selected pressure rails. These changes are made to minimize system inefficiencies or to keep the system within the torque capability of the electric motor. Hence, it is important to solve the motion control challenges for HHEA. This thesis aims at developing an effective motion control strategy for HHEA. The dissertation presents a two-tiered control strategy for HHEA, comprising a high-level and a low-level controller. The primary responsibility of the high- level controller is to optimize energy efficiency by making informed pressure rail selections. On the other hand, the low-level controller is focused on achieving precise motion control of the HHEA, which is crucial for realizing the desired reference trajectories. To achieve this, the low-level controller utilizes a passivity-based backstepping integral controller as the nominal control, which handles the motion control between two pressure rail switches. Additionally, a separate least norm controller is utilized as a transition controller to manage motion control during pressure rail transitions. The effectiveness of the combined control strategy is demonstrated through experiments conducted on two hardware-in-the-loop testbeds. Furthermore, the HHEA is installed on the boom and stick actuators of a backhoe arm to build a Human-in-the-Loop system that a human operator can control. A real-time rail switching algorithm is developed to determine pressure rail switching based on present duty cycle information from the operator. Modifications have been made to the human-machine interface to achieve more intuitive control. Modifications include performing control in the task-oriented coordinates, incorporating pressure feedback to enhance control with physical interaction, and using velocity field control to simplify multi-degree-of-freedom tasks and to enable novice operators to perform them with reduced risk, improved efficiency, and productivity. The research in this dissertation makes significant contributions to the field of off-road mobile machine control, providing a novel and effective control strategy for the HHEA, and demonstrating the potential for simplified machine operation.

24 POWER TRANSMISSION AND DISTRIBUTION↗