Search NASA⌕ Search

SEARCH · Search NASA

Results for “Light guides”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Adiabatic light guide with S-shaped strips

A light guide is an essential part of many scintillator counters and light collection systems. Our main interest is a light guide for a thin, wide scintillator that has high light transmission while converting the area of the light source to the shape of a photo-detector. Here, we propose a variation of the light guide that avoids a 90° twist of the strips, reduces the length of the light pipe, and reduces the complexity of production. Detailed Monte Carlo simulation studies have been performed for a three-strip S-shaped light-guide system.

47 OTHER INSTRUMENTATION↗

Differences in the response of two light guide technologies and two readout technologies after an exchange of liquid argon in the dewar

In this investigation the response to the scintillation light generated by through-going cosmic muons in liquid argon (LAr) was measured by two light guide technologies and two readout technologies after five weeks of running in the TallBo dewar at Fermilab. The response was remeasured after the dewar was drained of LAr, refilled, and then run again for an additional four weeks. After the dewar was refilled, there was clear evidence that the scintillation signal had dropped significantly. The two light guide technologies were developed at Indiana University and MIT/Fermilab. The two readout technologies were boards that passively or actively ganged 12 Hamamatsu MPPCs. Two possible explanations were identified for the degraded signal: the response of the two light guide technologies degraded due to damage caused by thermal cycling, and/or unknown differences in the trace residual Xe contamination in the fills of LAr led to the observed drop in scintillation light. Neither absorption nor quenching by N 2 , O 2 , and H 2 O contamination can account for the degradation. Neither the individual Hamamatsu MPPCs nor the passive/active ganging boards appear to have been affected by the thermal cycling. The path length distributions of the cosmics traversing the dewar appear quite similar in both event samples.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A 90 ° bend curved light-guide for TOF scintillating detectors

We report here a bench study of TOF resolution using a 90° bend curved solid light-guide (LG) used to transport the light from a plastic scintillator counter to a photomultiplier (PMT). The 90° LG allows the rotation of the PMT axis to be vertical to the detector axis, in an environment featured by a strong magnetic field along the detector surface, or other geometrical constrains. We show that with a TOF counter of 2000 x 100 x 60 mm 3 and light read-out by PMTs at its two 100 × 60 mm 2 sides, when 90° LG benders are used between the scintillating bar and the PMTs on both sides, the TOF resolution is worsen, by 5–10%.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Mutually guided light and particle beam propagation

The polarizability of atoms and molecules gives rise to optical forces that trap particles and a refractive index that guides light beams, potentially leading to a self-guided laser and particle beam propagation. In this paper, the mutual interactions between an expanding particle beam and a diffracting light beam are investigated using an axisymmetric particle-light coupled simulation. The nonlinear coupling between particles and photons is dependent on the particle beam radius, particle density, particle velocity and temperature, polarizability, light beam waist, light frequency (with respect to the resonance frequency), and light intensity. The computational results show that the maximum propagation distance is achieved when the waveguiding effect is optimized to single-mode operation. The application of the coupled beam propagation as a space propulsion system is discussed.

42 ENGINEERING↗

Guiding light via slippery liquid-infused porous surfaces

Slippery liquid-infused porous surfaces (SLIPSs) have been explored for many applications, taking advantage of their highly non-wetting property. In this work, we explore the SLIPS as a cladding material for waveguiding. SLIPSs are prepared by infusing perfluoropolyether oil to hydrophobized nanoporous surfaces of silicon. Power loss and transmission efficiency of an HeNe laser (1.82 mW and 632.8 nm) with varying incident angles were measured through microchannels consisting of the SLIPSs as cladding layers (noil = 1.30) and water (nwater = 1.33) as a core, compared to other cladding types including a planar silicon surface and the nanoporous surfaces in hydrophilic (Wenzel state) and hydrophobic (Cassie–Baxter state) conditions with no oil infused. Agreeing with Snell's law, a total internal reflection occurs at the incident angle as high as 14° for the SLIPSs. The waveguide loss at 14° is only 1.8 dB/cm for the SLIPSs, while those for planar silicon, hydrophilic nanoporous, and hydrophobic nanoporous surfaces are 5.9, 7.4, and 4.9 dB/cm, respectively. The power transmission efficiency of the SLIPSs is independent of the porosity because the surfaces are fully covered with the oil layer, whereas those of hydrophilic and hydrophobic nanoporous surfaces, whose pores are filled with water and air, respectively, depend on the porosity. The significantly lower power loss and the insensitivity to the surface porosity are advantages of the SLIPSs over the other surfaces and can benefit in waveguiding applications such as optofluidics.

Asawa, Kaustubh (ORCID:0000000197142555)↗

Multiple layer optics for light collecting and emitting apparatus

A light guide includes a light guide layer having a transversely oriented side-end surface that forms a primary output aperture (exit) for light traveling in a forward propagation direction out of the end surface of the light guide (for, e.g., CPV applications) and, which forms a primary input aperture (entrance) for light traveling in a rearward propagation direction into the end surface of the light guide (for, e.g., illuminator applications). A light collection and concentration system includes a light guide apparatus, a light-transmitting medium layer disposed immediately adjacent the single light guide apparatus, and a light concentrator component of multiple optical array layers disposed adjacent the light transmitting medium layer, which is in optical registration with a light injection layer of the light guide apparatus.

14 SOLAR ENERGY↗

Photonic Luminescent Solar Concentrator Design for High Efficiency, Low Cost Multijunction Photovoltaics

Despite the extraordinary advances in solar cell efficiency in laboratory settings, the deployment of solar cells continues to be limited to low efficiency (<25%) silicon cells because of cost. In this work, we take advantage of the extraordinary optical properties afforded by nanophotonic structures to create a photonic luminescent solar concentrator for an InGaP-Si multijunction concentrator cell. Finite difference time domain (FDTD) simulations demonstrated a concentrator that could effectively capture, downconvert, and guide concentrated light to an InGaP subcell while still transmitting longer wavelengths to a Si subcell. We fabricated the photonic luminescent solar concentrator, which was comprised of CdSe/CdS quantum dots embedded within alternating layers of Si 3 N 4 and SiO 2 , and experimentally verified the optical performance, showing a 40% increase in light guiding and a significant reduction in reabsorption losses in the plane of the luminescent concentrator as compared to traditional designs. Finally, we utilized modified detailed balance calculations that accounted for cell and optical losses and showed >30% efficiencies are possible with this design, demonstrating the potential to meet the demands for high efficiency, inexpensive solar modules.

Eisler, Carissa N.↗

Spacecraft Lighting to Mitigate Microbial Growth

In this innovation project, we investigated the usage of narrow band violet light (408 nm) to attenuate the growth of bacteria typically found on ISS. Violet light is less hazardous than UV light and it can transmit through plastics, such as clear acrylics, making it possible to incorporate into large surface lamps and acrylic or polycarbonate based optical light guides. This study built a custom LED surface panel that was edge lit by an array of 408 nm violet LEDS. The optical light guide technology used in the lamp and the 408 nm violet LEDs are available on the market from multiple vendors. The application of the concept of using violet light driven LED panels and optical light guides is to integrate the paneling into spacecraft architectural surfaces for the automation of a light based microbial countermeasure that could enhance current cleaning methods used in areas on spacecraft prone to microbial growth.

Clark, Toni A.↗

System and method for portable multi-band black body simulator

The present disclosure relates to an apparatus for simulating a black body spectrum. The apparatus makes use of a broadband light source and a light guide configured to receive light generated by the light source and to generate first and second optical signals. A first signal processing subsystem may be used to enable adjustment of both a signal spectrum and an intensity of the first optical signal. A second signal processing subsystem may be used to enable adjustment of both a signal spectrum and an intensity of the second optical signal. A beam cube may be used to combine the first and second optical signals to produce a final light output signal having a desired signal spectrum and a desired intensity.

42 ENGINEERING↗

Use of prismatic films to control light distribution

Piping light for illumination purposes is a concept which has been around for a long time. In fact, it was the subject of an 1881 United States patent which proposed the use of mirrors inside a tube to reflect light from wall to wall down the tube. The use of conventional mirrors for this purpose, however, has not worked because mirrors do not reflect well enough. On the other hand, optical fibers composed of certain glasses or plastics are known to transport light much more efficiently. The light that enters is reflected back and forth within the walls of the fiber until it reaches the other end. This is possible by means of a principle known as 'total internal reflection'. No light escapes through the walls and very little is absorbed in the bulk of the fiber. However, while optical fibers are very efficient in transporting light, they are impractical for transporting large quantities of light. Lorne Whitehead, as a student at the University of British Columbia, recognized that prismatic materials could be used to create a 'prism light guide', a hollow structure that can efficiently transport large quantities of light. This invention is a pipe whose transparent walls are formed on the outside into precise prismatic facets. The facets are efficient total internal reflection mirrors which prevent light travelling down the guide from escaping. Very little light is absorbed by the pipe because light travels primarily in the air space within the hollow guide. And, because the guide is hollow, weight and cost factors are much more favorable than would be the case with very large solid fibers. Recent advances in precision micromachining, polymer processing, and certain other manufacturing technologies have made the development of OLF (Optical Lighting Film) possible. The process is referred to as 'microreplication' and has been found to have broad applicability in a number of diverse product areas.

Kneipp, K. G.↗

High-Temperature Thermometer Using Cr-Doped GdAlO3 Broadband Luminescence

A new concept has been developed for a high-temperature luminescence-based optical thermometer that both shows the desired temperature sensitivity in the upper temperature range of present state-of-the-art luminescence thermometers (above 1,300 C), while maintaining substantial stronger luminescence signal intensity that will allow these optical thermometers to operate in the presence of the high thermal background radiation typical of industrial applications. This objective is attained by using a Cr-doped GdAlO3 (Cr:GdAlO3) sensor with an orthorhombic perovskite structure, resulting in broadband luminescence that remains strong at high temperature due to the favorable electron energy level spacing of Cr:GdAlO3. The Cr:GdAlO3 temperature (and pressure) sensor can be incorporated into, or applied onto, a component s surface when a non-contact surface temperature measurement is desired, or alternatively, the temperature sensor can be attached to the end of a fiber-optic probe that can then be positioned at the location where the temperature measurement is desired. In the case of the fiber-optic probe, both the pulsed excitation and the luminescence emission travel through the fiber-optic light guide. In either case, a pulsed light source provides excitation of the luminescence, and the broadband luminescence emission is collected. Real-time temperature measurements are obtain ed using a least-squares fitting algorithm that determines the luminescence decay time, which has a known temperature dependence established by calibration. Due to the broad absorption and emission bands for Cr:GdAlO3, there is considerable flexibility in the choice of excitation wavelength and emission wavelength detection bands. The strategic choice of the GdAlO3 host is based on its high crystal field, phase stability, and distorted symmetry at the Cr3+ occupation sites. The use of the broadband emission for temperature sensing at high temperatures is a key feature of the invention and is novel since broadband luminescence emission normally shows severe thermal quenching. The tightly bound AlO6 octahedra in GdAlO3 results in a larger energy barrier to nonradiative decays than in other materials and therefore makes using broadband emission for temperature sensing possible at high temperatures. This approach results in a substantial increase in temperature capability. For example, the most commonly used Cr-doped crystal used for luminescence-based temperature measurements, ruby, has only been demonstrated up to 600 C, whereas the Cr:GdAlO3 optical thermometer under development has already been shown to exhibit useful luminescence up to 1,300 C. Because GdAlO3 is non-reactive and is stable in harsh, high-temperature environments, sensors composed of Cr:GdAlO3 will be very well suited for remote high-temperature measurements in engine or industrial environments where its intense high-temperature luminescence will stand out above significant thermal radiation background levels.

Eldridge, Jeffrey↗

Design and implementation of the cosmic ray tagger system for the ICARUS detector at FNAL

The ICARUS-T600 Liquid Argon Time Projection Chamber is operating at Fermilab at shallow depth and thus exposed to a high flux of cosmic rays that can fake neutrino interactions. A cosmic ray tagging (CRT) system (∼ 1100 m 2 ), surrounding the cryostat with two layers of fiber embedded plastic scintillators, was developed to mitigate the cosmic ray induced background. Using nanosecond-level timing information, the CRT can distinguish incoming cosmic rays from outgoing particles from neutrino interactions in the TPC. In this paper an overview of the CRT system, its installation and commissioning at Fermilab, and its performance are discussed.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Development and validation of a gamma-ray detection response model for neutron-diagnosed subcritical experiments

In a neutron-diagnosed subcritical experiment, a highly sensitive and fast detector is required to accurately determine the true fission γ-ray emission rate from an object composed of special nuclear material under interrogation, in addition to a proper detector response model for use in forward modeling. We present the development of a detector response model that is based in GEANT4 and uses post-processing techniques to include photomultiplier tube time and pulse height response effects. We also define a set of detector performance evaluation metrics that emphasized our experimental objectives. A suite of time and pulse height response measurements for several diverse detector assemblies are described. These assemblies were simulated with this response model and benchmarked against the laboratory measurements. This response model reproduces the pulse height curve shapes and performance hierarchy of the measured detectors well. Additionally, the simulated time response curves exhibit reasonable agreement with counterpart measurements. These measurements and simulation results together suggest that a large volume EJ-299-49 plastic scintillator that is mated to an ultraviolet transmitting plastic light guide and relies on total internal reflection for light transport to the photocathode will provide significantly faster timing, increase pulse height by a factor of 3, and require 25% less γ rays to meet experimental needs, compared to the candidate detector design developed prior to the availability of this response model. Application of this response model and associated performance metrics in the context of large-scale design sensitivity studies is also discussed.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A procedure for determining the optical characteristics of a device for measuring illumination in the atmosphere of Venus

A procedure is described for obtaining the calibration, angular and spectral characteristics of a broad band photometer used on Venera 9 and 10 spacecraft to measure the illuminance regime in five spectral intervals with respect to three directions. The photometer has three identical groups of photoreceivers on which light falls through fiber light guides. Each group contains three cadmium sulfide photoresistors with light filters, a cadmium selenide photoresistor and a silicon photodiode. The temperature of the photoreceivers is measured by thermistors installed in series with the receivers.

Golovin, Y. M.↗