Search NASA⌕ Search

SEARCH · Search NASA

Results for “Light guides”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Adiabatic light guide with S-shaped strips

A light guide is an essential part of many scintillator counters and light collection systems. Our main interest is a light guide for a thin, wide scintillator that has high light transmission while converting the area of the light source to the shape of a photo-detector. Here, we propose a variation of the light guide that avoids a 90° twist of the strips, reduces the length of the light pipe, and reduces the complexity of production. Detailed Monte Carlo simulation studies have been performed for a three-strip S-shaped light-guide system.

47 OTHER INSTRUMENTATION↗

Differences in the response of two light guide technologies and two readout technologies after an exchange of liquid argon in the dewar

In this investigation the response to the scintillation light generated by through-going cosmic muons in liquid argon (LAr) was measured by two light guide technologies and two readout technologies after five weeks of running in the TallBo dewar at Fermilab. The response was remeasured after the dewar was drained of LAr, refilled, and then run again for an additional four weeks. After the dewar was refilled, there was clear evidence that the scintillation signal had dropped significantly. The two light guide technologies were developed at Indiana University and MIT/Fermilab. The two readout technologies were boards that passively or actively ganged 12 Hamamatsu MPPCs. Two possible explanations were identified for the degraded signal: the response of the two light guide technologies degraded due to damage caused by thermal cycling, and/or unknown differences in the trace residual Xe contamination in the fills of LAr led to the observed drop in scintillation light. Neither absorption nor quenching by N 2 , O 2 , and H 2 O contamination can account for the degradation. Neither the individual Hamamatsu MPPCs nor the passive/active ganging boards appear to have been affected by the thermal cycling. The path length distributions of the cosmics traversing the dewar appear quite similar in both event samples.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A 90 ° bend curved light-guide for TOF scintillating detectors

We report here a bench study of TOF resolution using a 90° bend curved solid light-guide (LG) used to transport the light from a plastic scintillator counter to a photomultiplier (PMT). The 90° LG allows the rotation of the PMT axis to be vertical to the detector axis, in an environment featured by a strong magnetic field along the detector surface, or other geometrical constrains. We show that with a TOF counter of 2000 x 100 x 60 mm 3 and light read-out by PMTs at its two 100 × 60 mm 2 sides, when 90° LG benders are used between the scintillating bar and the PMTs on both sides, the TOF resolution is worsen, by 5–10%.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Mutually guided light and particle beam propagation

The polarizability of atoms and molecules gives rise to optical forces that trap particles and a refractive index that guides light beams, potentially leading to a self-guided laser and particle beam propagation. In this paper, the mutual interactions between an expanding particle beam and a diffracting light beam are investigated using an axisymmetric particle-light coupled simulation. The nonlinear coupling between particles and photons is dependent on the particle beam radius, particle density, particle velocity and temperature, polarizability, light beam waist, light frequency (with respect to the resonance frequency), and light intensity. The computational results show that the maximum propagation distance is achieved when the waveguiding effect is optimized to single-mode operation. The application of the coupled beam propagation as a space propulsion system is discussed.

42 ENGINEERING↗

Guiding light via slippery liquid-infused porous surfaces

Slippery liquid-infused porous surfaces (SLIPSs) have been explored for many applications, taking advantage of their highly non-wetting property. In this work, we explore the SLIPS as a cladding material for waveguiding. SLIPSs are prepared by infusing perfluoropolyether oil to hydrophobized nanoporous surfaces of silicon. Power loss and transmission efficiency of an HeNe laser (1.82 mW and 632.8 nm) with varying incident angles were measured through microchannels consisting of the SLIPSs as cladding layers (noil = 1.30) and water (nwater = 1.33) as a core, compared to other cladding types including a planar silicon surface and the nanoporous surfaces in hydrophilic (Wenzel state) and hydrophobic (Cassie–Baxter state) conditions with no oil infused. Agreeing with Snell's law, a total internal reflection occurs at the incident angle as high as 14° for the SLIPSs. The waveguide loss at 14° is only 1.8 dB/cm for the SLIPSs, while those for planar silicon, hydrophilic nanoporous, and hydrophobic nanoporous surfaces are 5.9, 7.4, and 4.9 dB/cm, respectively. The power transmission efficiency of the SLIPSs is independent of the porosity because the surfaces are fully covered with the oil layer, whereas those of hydrophilic and hydrophobic nanoporous surfaces, whose pores are filled with water and air, respectively, depend on the porosity. The significantly lower power loss and the insensitivity to the surface porosity are advantages of the SLIPSs over the other surfaces and can benefit in waveguiding applications such as optofluidics.

Asawa, Kaustubh (ORCID:0000000197142555)↗

Multiple layer optics for light collecting and emitting apparatus

A light guide includes a light guide layer having a transversely oriented side-end surface that forms a primary output aperture (exit) for light traveling in a forward propagation direction out of the end surface of the light guide (for, e.g., CPV applications) and, which forms a primary input aperture (entrance) for light traveling in a rearward propagation direction into the end surface of the light guide (for, e.g., illuminator applications). A light collection and concentration system includes a light guide apparatus, a light-transmitting medium layer disposed immediately adjacent the single light guide apparatus, and a light concentrator component of multiple optical array layers disposed adjacent the light transmitting medium layer, which is in optical registration with a light injection layer of the light guide apparatus.

14 SOLAR ENERGY↗

Photonic Luminescent Solar Concentrator Design for High Efficiency, Low Cost Multijunction Photovoltaics

Despite the extraordinary advances in solar cell efficiency in laboratory settings, the deployment of solar cells continues to be limited to low efficiency (<25%) silicon cells because of cost. In this work, we take advantage of the extraordinary optical properties afforded by nanophotonic structures to create a photonic luminescent solar concentrator for an InGaP-Si multijunction concentrator cell. Finite difference time domain (FDTD) simulations demonstrated a concentrator that could effectively capture, downconvert, and guide concentrated light to an InGaP subcell while still transmitting longer wavelengths to a Si subcell. We fabricated the photonic luminescent solar concentrator, which was comprised of CdSe/CdS quantum dots embedded within alternating layers of Si 3 N 4 and SiO 2 , and experimentally verified the optical performance, showing a 40% increase in light guiding and a significant reduction in reabsorption losses in the plane of the luminescent concentrator as compared to traditional designs. Finally, we utilized modified detailed balance calculations that accounted for cell and optical losses and showed >30% efficiencies are possible with this design, demonstrating the potential to meet the demands for high efficiency, inexpensive solar modules.

Eisler, Carissa N.↗

System and method for portable multi-band black body simulator

The present disclosure relates to an apparatus for simulating a black body spectrum. The apparatus makes use of a broadband light source and a light guide configured to receive light generated by the light source and to generate first and second optical signals. A first signal processing subsystem may be used to enable adjustment of both a signal spectrum and an intensity of the first optical signal. A second signal processing subsystem may be used to enable adjustment of both a signal spectrum and an intensity of the second optical signal. A beam cube may be used to combine the first and second optical signals to produce a final light output signal having a desired signal spectrum and a desired intensity.

42 ENGINEERING↗

Design and implementation of the cosmic ray tagger system for the ICARUS detector at FNAL

The ICARUS-T600 Liquid Argon Time Projection Chamber is operating at Fermilab at shallow depth and thus exposed to a high flux of cosmic rays that can fake neutrino interactions. A cosmic ray tagging (CRT) system (∼ 1100 m 2 ), surrounding the cryostat with two layers of fiber embedded plastic scintillators, was developed to mitigate the cosmic ray induced background. Using nanosecond-level timing information, the CRT can distinguish incoming cosmic rays from outgoing particles from neutrino interactions in the TPC. In this paper an overview of the CRT system, its installation and commissioning at Fermilab, and its performance are discussed.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Development and validation of a gamma-ray detection response model for neutron-diagnosed subcritical experiments

In a neutron-diagnosed subcritical experiment, a highly sensitive and fast detector is required to accurately determine the true fission γ-ray emission rate from an object composed of special nuclear material under interrogation, in addition to a proper detector response model for use in forward modeling. We present the development of a detector response model that is based in GEANT4 and uses post-processing techniques to include photomultiplier tube time and pulse height response effects. We also define a set of detector performance evaluation metrics that emphasized our experimental objectives. A suite of time and pulse height response measurements for several diverse detector assemblies are described. These assemblies were simulated with this response model and benchmarked against the laboratory measurements. This response model reproduces the pulse height curve shapes and performance hierarchy of the measured detectors well. Additionally, the simulated time response curves exhibit reasonable agreement with counterpart measurements. These measurements and simulation results together suggest that a large volume EJ-299-49 plastic scintillator that is mated to an ultraviolet transmitting plastic light guide and relies on total internal reflection for light transport to the photocathode will provide significantly faster timing, increase pulse height by a factor of 3, and require 25% less γ rays to meet experimental needs, compared to the candidate detector design developed prior to the availability of this response model. Application of this response model and associated performance metrics in the context of large-scale design sensitivity studies is also discussed.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Bragg grating inscription in photosensitive materials by an optical replication process

This paper examines the feasibility of producing multiplexed Bragg gratings for use as diffractive optical elements (DOEs) by coherent optical replication of a surface-relief phase grating into thick-film photosensitive materials. The use of such DOEs in light guide plates (LGPs) for optical imaging systems ensures energy-efficient light input into and output from LGPs and allows one to minimise their weight and size. We present simulation results for the interference structure fabrication process and recording of a series of multiplexed diffraction gratings in photosensitive materials. (paper)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Multi-modality deep learning for pulse prediction in homogeneous nonlinear systems via parametric conversion

In this Letter, we introduce FusionNet, a multi-modality deep learning framework designed to predict and analyze output pulses in high-power rare-earth-doped laser systems driving parametric conversion in homogeneous guided nonlinear media. FusionNet integrates temporal, spectral, and physical experimental conditions to model ultrafast nonlinear phenomena, including parametric nonlinear frequency conversion, self-phase modulation, and cross-phase modulation in homogeneous guided systems such as gas-filled hollow-core fibers. These systems bridge physical models with experimental data, advancing our understanding of light-guiding principles and nonlinear interactions while expediting the design and optimization of on-demand high-power, high-brightness systems. Our results demonstrate a 73% reduction in prediction error and an 83% improvement in computational efficiency compared to conventional neural networks. This work establishes a new paradigm for accelerating parametric simulations and optimizing experimental designs in high-power laser systems, with further implications for high-precision spectroscopy, quantum information science, and distributed entangled interconnects.

47 OTHER INSTRUMENTATION↗

Photo-scanning Electrochemical Microscopy Observation of Overall Water Splitting at a Single Aluminum-Doped Strontium Titanium Oxide Microcrystal

Particulate photocatalysts for the overall water-splitting (OWS) reaction offer promise as devices for hydrogen fuel generation. Even though such photocatalysts have been studied for nearly five decades, much of the understanding of their function is derived from observations of catalyst ensembles and macroscopic photoelectrodes. This is because the sub-micrometer size of most OWS photocatalysts makes spatially resolved measurements of their local reactivity very difficult. Here we employ photo-scanning electrochemical microscopy (photo-SECM) to quantitatively measure hydrogen and oxygen evolution at individual OWS photocatalyst particles for the first time. Micrometer-sized Al-doped SrTiO 3 /Rh 2-y Cr y O 3 photocatalyst particles were immobilized on a glass substrate and interrogated with a chemically modified SECM nanotip. The tip simultaneously served as a light guide to illuminate the photocatalyst and as an electrochemical nanoprobe to observe oxygen and hydrogen fluxes from OWS. Local O 2 and H 2 fluxes obtained from chopped light experiments and photo-SECM approach curves using a COMSOL Multiphysics finite-element model confirmed stoichiometric H 2 /O 2 evolution of 9.3/4.6 μmol cm -2 h -1 with no observable lag during chopped illumination cycles. Additionally, photoelectrochemical experiments on a single microcrystal attached to a nanoelectrode tip revealed a strong light intensity dependence of the OWS reaction. Here these results provide the first confirmation of OWS at single micrometer-sized photocatalyst particles. The developed experimental approach is an important step towards assessing the activity of photocatalyst particles at the nanometer scale.

25 ENERGY STORAGE↗

Topological photonic crystal fiber

Photonic crystal fibers (PCFs) provide a versatile platform for various applications, thanks to the flexibility with which light guiding can be customized by modifying the fiber geometry. We realize a PCF with guided modes produced by photonic band structure topology rather than conventional mode-trapping mechanisms. The design, which is compatible with the stack-and-draw fabrication process, consists of a cross-sectional photonic topological crystalline insulator with a disclination. A bulk-defect correspondence produces degenerate topological modes, lying below the cladding light line. We use various theoretical methods to confirm their topological origins, including a spectral localizer that makes minimal assumptions about the band structure. Our experiments on the fabricated fiber show it transmitting visible to near-infrared light with low losses of 10 to 20 decibels per kilometer, which do not increase substantially when the fiber is bent. A comparable solid-core PCF of conventional design exhibits substantially higher bending losses. Optical fibers based on topological modes hold promise for improved performance and versatile functionalities.

Zhu, Bofeng [Nanyang Technological Univ. (Singapor↗

Design and Construction of a High-Resolution Hodoscope for the GlueX Experiment with High-Statistics Analysis of the p0, ¿, and ¿1 Photoproduction Cross Sections from the RadPhi Experiment

Differential cross sections for forward-angle photoproduction of p0, ¿, and ¿ 1 pseudoscalar mesons were measured using data from the RadPhi experiment conducted in Hall B at Jef ferson Lab. RadPhi utilized a tagged bremsstrahlung photon beam incident on a stationary 9Be target, with a detector system configured to trigger on a recoil proton in coincidence with multiple neutral showers in the calorimeter. Events were reconstructed and subjected to kinematic constraints, with background suppressed via sideband subtraction guided by Monte Carlo modeling of background contributions. Cross sections were extracted over the photon energy range 4.4– 5.4 GeV and binned in invariant momentum transfer t, providing measurements from one of the first high-statistics experiments of forward ¿ and ¿1 pro duction from a nuclear target at these energies. Acceptance corrections were applied using a detailed GEANT-based simulation of the detector geometry and response. The resulting cross sections are consistent with 2020 CLAS results, when scaled by the number of protons in beryllium, and show broad agreement with other data and theoretical models. In parallel, a high-resolution photon tagger detector, the Tagger Microscope (TAGM), was designed, constructed, and commissioned for the GlueX experiment in Hall D at Jefferson Lab. The TAGM was developed to provide high-rate tagging capability in the coherent bremsstrahlung peak by detecting post-bremsstrahlung electrons across a one GeV range along the focal plane of the tagging spectrometer. The detector consists of a 5ˆ102 array of 2ˆ2 mm2 square BCF-20 plastic scintillating fibers thermally fused to BCF-98 light guide fibers optically coupled to silicon photomultipliers. These fibers are mounted in a precision machined framework enabling fine positional adjustments to maintain precise alignment with post-bremsstrahlung electron trajectories, while ensuring mechanical rigidity, thermal stability, optical isolation, minimal inactive area, and radiation shielding for electronics. The construction effort involved extensive testing of fiber quality, light transmission, thermal fusing, radiation hardness, and defect analysis using SEM and EDX techniques. Following its installation and commissioning, the TAGM became a critical component of the GlueX beamline, enabling high-rate tagging essential for studies of hybrid mesons and gluonic ex citations.

McIntyre, James [Univ. of Connecticut, Storrs, CT ↗

Light-Controlled Nanoparticle Collision Experiments

Electrochemical monitoring of catalytically amplified collisions of individual metal nanoparticles (NP) with ultramicroelectrodes (UME) has been extensively used to study electrocatalysis, mass-transport, and charge-transfer processes at the single NP level. More recently, photoelectrochemical collision experiments were carried out with semiconductive NPs. Here we introduce two new types of light-controlled nano-impact experiments. The first experiment involves localized photodeposition of catalyst (Pt) on TiO 2 NPs with a glass-sheathed carbon fiber simultaneously serving as the light guide and collector UME. The collisions of in situ prepared Pt@TiO 2 NPs with the carbon surface produced blips of water oxidation current, while the activity of pristine TiO 2 NPs was too low to yield measurable signal. In another experiment, collisions of catalytic (Ir oxide) NPs with the semiconductor (Nb doped n-type TiO 2 rutile single crystal) electrode are monitored by measuring the photocurrent of water oxidation.

14 SOLAR ENERGY↗

The CLAS12 Central Time-of-Flight system

The Central Time-of-Flight system for the large-acceptance CLAS12 spectrometer in Hall B at the Thomas Jefferson National Accelerator Facility is described. The system consists of a hermetic barrel of 48 scintillation counters at a radius of 25 cm from the beamline. The wedge-shaped counters are 3.4 cm wide, 3.0 cm thick, and 90 cm long, and span a range of polar angles relative to the center of the nominal target location from roughly 35° to 125°. The counters reside in the 5-T field of the CLAS12 superconducting solenoid. The bars are read out via bent light guides 1 m long on the upstream end of the counters and 1.6 m long on the downstream end. The phototubes are shielded by a multi-layer dynamical magnetic shield system to reduce the local fringe fields in the range from 400 G to 1000 G down to the level of 0.2 G at the location of the photocathodes. The average effective time resolution of the counters is 80 ps.

47 OTHER INSTRUMENTATION↗