Search NASA⌕ Search

SEARCH · Search NASA

Results for “Liquid Argon Detector”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Thermodynamic stability of xenon-doped liquid argon detectors

Liquid argon detectors are employed in a wide variety of nuclear and particle physics experiments. The addition of small quantities of xenon to argon modifies its scintillation, ionization, and electroluminescence properties and can improve its performance as a detection medium. However, a liquid argon-xenon mixture can develop instabilities, especially in systems that require phase transitions or that utilize high xenon concentrations. In this work, we analyze the causes of these instabilities and describe a small (liter-scale) apparatus with a unique cryogenic circuit specifically designed to handle argon-xenon mixtures. The system is capable of condensing argon gas mixed with $\mathscr{O}$ (1%) xenon by volume and maintains a stable liquid mixture near the xenon saturation limit while actively circulating it in the gas phase. We also demonstrate control over instabilities that develop when the detector condition is allowed to deviate from optimized settings. This progress enables future liquid argon detectors to benefit from the effects of high concentrations of xenon doping, such as more efficient detection of low-energy ionization signals. In conclusion, this work also develops tools to study and mitigate instabilities in large argon detectors that use low concentration xenon doping.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Performance and Technical Challenges of Liquid Argon Detectors

Liquid argon time projection chambers offer the possibility of incredible resolution of particle interactions. This review outlines the ongoing research and development towards the realization of a multi-kiloton scale detector. The ICARUS and ArgoNeuT experiments which make use of liquid argon time projection chamber technology are also described.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Atmospheric tau neutrinos in a multikiloton liquid argon detector

An ultralarge liquid argon time projection chamber based neutrino detector will have the uncommon ability to detect atmospheric {nu}{sub {tau}}/{nu}{tau} events. This paper discusses the most promising modes for identifying charged current {nu}{sub {tau}}/{nu}{tau}, and shows that, with simple kinematic cuts, {approx}30 {nu}{sub {tau}}+{nu}{tau} interactions can be isolated in a 100 kt{center_dot}yr exposure, with greater than 4{sigma} significance. This sample is sufficient to perform flux-averaged total cross-section and cross-section shape parametrization measurements--the first steps toward using {nu}{sub {tau}}/{nu}{tau} to search for physics beyond the standard model.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Modeling impurity concentrations in liquid argon detectors

Impurities in noble liquid detectors used for neutrino and dark matter experiments can significantly impact the quality of data. We present an experimentally verified model for describing the dynamics of impurity distributions in liquid argon (LAr) detectors. The model considers sources, sinks, and transport of impurities within and between the gas and liquid argon phases. Measurements of oxygen concentrations in a 20-L LAr multi-purpose test stand are compared to calculations made with this model to show that an accurate description of the concentrations under various operational conditions can be obtained. A result of this analysis is a determination of Henry’s coefficient for oxygen in LAr. Additionally, these calculations also show that some processes have small effects on the impurity dynamics and excluding them yields a solution as a sum of two exponential terms. This solution provides a simple way to extract Henry’s coefficient with negligible approximation error. It is applied to the data and the Henry’s coefficient for oxygen in LAr is obtained as 0.84 +0.09 -0.05 , consistent with literature results. Finally, based on the analysis of the data with the model, we further suggest that, for a large liquid argon detector, barriers to flow (“baffles”) installed in the gas phase to restrict flow can help reduce the ultimate impurity concentration in the LAr.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Resolving the mass hierarchy with atmospheric neutrinos using a liquid argon detector

We explore the potential offered by large-mass liquid argon detectors for determination of the sign of {delta}m{sub 31}{sup 2}, or the neutrino mass hierarchy, through interactions of atmospheric neutrinos. We give results for a 100 kT sized magnetized detector which provides separate sensitivity to {nu}{sub {mu}}, {nu}{sub {mu}} and, over a limited energy range, to {nu}{sub e}, {nu}{sub e}. We also discuss the sensitivity for the unmagnetized version of such a detector. After including the effect of smearing in neutrino energy and direction and incorporating the relevant statistical, theoretical, and systematic errors, we perform a binned {chi}{sup 2} analysis of simulated data. The {chi}{sup 2} is marginalized over the presently allowed ranges of neutrino parameters and determined as a function of {theta}{sub 13}. We find that such a detector offers superior capabilities for hierarchy resolution, allowing a >4{sigma} determination for a 100 kT detector over a 10-year running period for values of sin{sup 2}2{theta}{sub 13}{>=}0.05. For an unmagnetized detector, a 2.5{sigma} hierarchy sensitivity is possible for sin{sup 2}2{theta}{sub 13}=0.04.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

A novel use of light guides and wavelength shifting plates for the detection of scintillation photons in large liquid argon detectors

Scintillation light generated as charged particles traverse large liquid argon detectors adds valuable information to studies of weakly-interacting particles. This paper uses both laboratory measurements and cosmic ray data from the Blanche dewar facility at Fermilab to characterize the efficiency of the photon detector technology developed at Indiana University for the single phase far detector of DUNE. The efficiency of this technology was found to be 0.48% at the readout end when the detector components were characterized with laboratory measurements. A second determination of the efficiency using cosmic ray tracks is in reasonable agreement with the laboratory determination. In conclusion, the agreement of these two efficiency determinations supports the result that minimum ionizing muons generate ${\mathcal N}_{phot} = 40,000$ photons/MeV as they cross the LAr volume.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A hybrid 3D/2D field response calculation for liquid argon detectors with PCB based anode plane

Liquid Argon Time Projection Chamber (LArTPC) technology is commonly utilized in neutrino detector designs. It enables detailed reconstruction of neutrino events with high spatial precision and low energy threshold. Its field response (FR) model describes the time-dependent electric currents induced in the anode-plane electrodes when ionization electrons drift nearby. An accurate and precise FR is a crucial input to LArTPC detector simulations and charge reconstruction. Established LArTPC designs have been based on parallel wire planes. It allows accurate and computationally economic two-dimensional (2D) FR models utilizing the translational symmetry along the direction of the wires. Recently, novel LArTPC designs utilize electrodes formed on printed circuit board (PCB) in the shape of strips with through holes. The translational symmetry is no longer a good approximation near the electrodes and a new FR calculation that employs regions with three dimensions (3D) has been developed. Extending the 2D models to 3D would be computationally expensive. Fortuitously, the nature of strips with through holes allows for a computationally economic approach based on the finite-difference method (FDM). In this paper, we present a new software package pochoir that calculates LArTPC field response for these new strip-based anode designs. This package combines 3D calculations in the volume near the electrodes with 2D far-field solutions to achieve fast and precise field response computation. We apply the resulting FR to simulate and reconstruct samples of cosmic-ray muons and 39 Ar decays from a Vertical Drift (VD) detector prototype operated at CERN. We find the difference between real and simulated data within 5%. Current state-of-the-art LArTPC software requires a 2D FR which we provide by averaging over one dimension and estimate that variations lost in this average are smaller than 7%.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Characterization of the scintillation time response of liquid argon detectors for dark matter search

The scintillation time response of liquid argon has a key role in the discrimination of electronic backgrounds in dark matter search experiments. However, its extraordinary rejection power can be affected by various detector effects such as the delayed light emission of TetraPhenyl Butadiene, the most commonly used wavelength shifter, and the electric drift field applied in Time Projection Chambers. Herein, we characterized the TetraPhenyl Butadiene delayed response and the dependence of the pulse shape discrimination on the electric field, exploiting the data acquired with the ARIS, a small-scale single-phase liquid argon detector exposed to monochromatic neutron and gamma sources at the ALTO facility of IJC Lab in Orsay.

47 OTHER INSTRUMENTATION↗

Development of a 83 mKr source for the calibration of the CENNS-10 liquid argon detector

We report on the preparation of and calibration measurements with a 83 mKr source for the CENNS-10 liquid argon detector. 83 mKr atoms generated in the decay of a 83 Rb source were introduced into the detector via injection into the Ar circulation loop. Scintillation light arising from the 9.4 keV and 32.1 keV conversion electrons in the decay of 83 mKr in the detector volume were then observed. This calibration source allows the characterization of the low-energy response of the CENNS-10 detector and is applicable to other low-energy-threshold detectors. The energy resolution of the detector was measured to be 9% at the total 83 mKr decay energy of 41.5 keV. Lastly, we performed an analysis to separately calibrate the detector using the two conversion electrons at 9.4 keV and 32.1 keV.

47 OTHER INSTRUMENTATION↗

R and D towards huge liquid argon detectors for nucleon decay, neutrino astrophysics and CP-violation in the lepton sector

There are several R and D efforts around the world working toward huge liquid argon detectors for nucleon decay, neutrino astrophysics and CP-violation in the lepton sector. In this proceedings, we describe several R and D tasks. Some of the differences between those techniques will be covered, as well as the current status of those efforts. We will describe a recently developed technique called the double phase detector.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Large area liquid argon detectors for interrogation systems

Measurements of the efficiency, pulse shape, and energy and time resolution of liquid argon (LAr) detectors are presented. Liquefied noble gas-based (LNbG) detectors have been developed for the detection of dark matter and neutrinoless double-beta decay. However, the same qualities that make LNbG detectors ideal for these applications, namely their size, cost, efficiency, pulse shape discrimination and resolution, make them promising for portal screening and the detection of Special Nuclear Materials (SNM). Two 18-liter prototype detectors were designed, fabricated, and tested, one with pure LAr and the other doped with liquid Xe (LArXe). The LArXe detector presented the better time and energy resolution of 3.3 ns and 20% at 662 KeV, respectively. The total efficiency of the detector was measured to be 35% with 4.5% of the total photons detected in the photopeak.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Probing mass orderings in presence of a very light sterile neutrino in a liquid argon detector

Results from experiments like LSND and MiniBooNE hint towards the possible presence of an extra eV scale sterile neutrino. The addition of such a neutrino will significantly impact the standard three flavor neutrino oscillations. In particular, it can give rise to additional degeneracies due to additional sterile parameters. For an eV scale sterile neutrino, the cosmological constraints dictate that the sterile state is heavier than the three active states. However, for lower masses of sterile neutrinos, the sterile state can be lighter than one and/or more of the three states. In such cases, the mass ordering of the sterile neutrinos also becomes unknown, along with the mass ordering of the active states. In this paper, we explore the mass ordering sensitivity in the presence of a sterile neutrino assuming the mass squared difference |Δ 41 | to be in the range 10 –4 –1 eV 2 . We study (i) how the ordering of the active states, i.e. the determination of the sign of Δ 31 gets affected by the presence of a sterile neutrino in the above mass range, (ii) the possible determination of the sign of Δ 41 for Δ 41 in the range 10 –4 –0.1 eV 2 . This analysis is done in the context of a liquid argon detector using beam neutrinos traveling a distance of 1300 km and atmospheric neutrinos that propagate through a distance ranging from 10 – 10000 km, allowing resonant matter effects. Apart from presenting separate results from these sources, we also do a combined study and probe the synergy between these two in giving an enhanced sensitivity.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

First Leptophobic Dark Matter Search from the Coherent–CAPTAIN-Mills Liquid Argon Detector

We report the first results of a search for leptophobic dark matter (DM) from the Coherent–CAPTAIN-Mills (CCM) liquid argon (LAr) detector. An engineering run with 120 photomultiplier tubes (PMTs) and 17.9 × 10 20 protons on target (POT) was performed in fall 2019 to study the characteristics of the CCM detector. The operation of this 10-ton detector was strictly light based with a threshold of 50 keV and used coherent elastic scattering off argon nuclei to detect DM. Despite only 1.5 months of accumulated luminosity, contaminated LAr, and nonoptimized shielding, CCM’s first engineering run has already achieved sensitivity to previously unexplored parameter space of light dark matter models with a baryonic vector portal. With an expected background of 115 005 events, we observe 115 005 + 16.5 events which is compatible with background expectations. For a benchmark mediator-to-DM mass ratio of m V B =m χ = 2.1, DM masses within the range 9 MeV ≲ m χ ≲ 50 MeV are excluded at 90% C. L. in the leptophobic model after applying the Feldman-Cousins test statistic. CCM’s upgraded run with 200 PMTs, filtered LAr, improved shielding, and 10 times more POT will be able to exclude the remaining thermal relic density parameter space of this model, as well as probe new parameter space of other leptophobic DM models.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Intelligent Triggers for Rare Event Detection in Liquid Argon Detectors

Next-generation neutrino experiments like SBND and DUNE rely on Liquid Argon Time Projection Chambers (LArTPCs), which produce exceptionally detailed data at high volume. Capturing rare or unexpected events in real-time is a major challenge. Our project explores the use of machine learning, specifically autoencoder-based anomaly detection, to identify unusual activity directly from raw detector signals. Inspired by successes at the CMS experiment, we demonstrate that such methods can be adapted to LArTPCs and show promising results in both simulated studies and early steps toward real-time hardware deployment. This approach could open new avenues for detecting signals from physics beyond the Standard Model.

Chung, Seokju [Columbia U. (main)]↗

GLADE Global Liquid Argon Detector Experiment: A Letter of Intent to FNAL

The recent measurements of the θ 13 mixing angle, which controls the observable size of any CP violation effects, open a window of opportunity to take advantage of the world's most powerful existing neutrino beam together with recent successes in development of the ultimate detector technology for the detection of electron neutrinos : a liquid argon (LAr) time projection chamber. During this proposed project a 5kt LAr detector (GLADE) will be developed by European groups to be put in a cryostat in the NuMI neutrino beam at Fermi National Accelerator Laboratory in the US and will start taking data in 3-5 years time to address the neutrino mass ordering. The successful fruition of this project, along with nominal exposure at NOυA and T2K, together with information from double beta decay experiments could ascertain that neutrinos are Dirac particles in the next decade.

43 PARTICLE ACCELERATORS↗