Numerical Study of Near-Isothermal Liquid Piston Compression with a Liquid Droplet Injection Using Unsteady Reynolds-Averaged Navier-Stokes Coupled with Lagrangian-Eulerian Model
Explore the source record for details and available documents.
SEARCH · Search NASA
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Explore the source record for details and available documents.
This study investigates the use of an ejector in a transcritical CO2 cycle employing a near-isothermal liquid piston compressor, with the objective of mitigating refrigerant degassing in mineral oil. While the liquid piston compressor demonstrated high isothermal efficiency (˜90%), overall cycle performance was limited by CO2 degassing during chamber pressure fluctuations. A thermodynamic model was developed to compare baseline and ejector-assisted cycles, incorporating solubility correlations, entrainment ratio characteristics, and a degassing correction factor. Results indicate that the ejector increased suction pressure and reduced CO2–oil solubility variation, which improved refrigerant intake and reduced degassing losses. Despite these benefits, the ejector-assisted cycle showed a lower coefficient of performance (COP) than the baseline. Possible contributing factors include the limited marginal benefit of pressure reduction in a highly efficient isothermal compressor, reduced effectiveness of the separator due to the use of a suction-line heat exchanger in both cycles, and uncertainties in the solubility data under transient conditions. These findings suggest that degassing mitigation is essential for realizing the potential of liquid piston compression, but ejector integration alone is unlikely to enhance COP. Future work should focus on ejector optimization, improved oil–refrigerant management, introducing less-soluble working liquids, and experimental validation under realistic operating conditions.
Compressors are critical components in vapor compression cycle systems, significantly contributing to energy consumption. As global demand for HVAC&R systems rises, enhancing compressor efficiency becomes increasingly vital. This paper introduces a novel liquid piston compressor integrated with a gas cooler for the transcritical CO 2 refrigeration cycle. The liquid piston enables CO 2 refrigerant compression within various types of heat exchangers, facilitating the transfer of compression heat to the heat transfer fluid. By releasing significant heat, this compressor allows for removing or downsizing the traditional gas cooler in the refrigeration system. This paper presents the experimental performance of the first near-isothermal compressor utilizing a liquid piston in a vapor compression cycle. The critical parameters affecting heat transfer are analyzed by using a 1-D simulation model to achieve a near-isothermal compression process. The results show that the developed prototype successfully reduced the compression temperature increase from 95 K to 10 K, achieving 90 % isothermal efficiency. Furthermore, the 1-D simulation results suggest the smaller internal diameter tubes benefit the isothermal efficiency the most.
This report outlines the development of a near-isothermal liquid piston compressor. Initially, a proof-of-concept experiment was conducted to validate the feasibility and potential of near-isothermal compression. A first-of-its-kind near-isothermal liquid piston compressor was then successfully built and tested. Additionally, a Matlab-based transient model was developed to capture performance trends accurately. These efforts laid the groundwork for developing a second-generation prototype with enhanced efficiency and design. Subsequent field tests at the Helix Innovation Center in Ohio demonstrated a cooling capacity of 2 kW with a COP of 1.64 at an ambient temperature of 25°C. An improved model was also created to suggest different heat exchanger geometries for better compression efficiency.
The goal of this project was to prototype and characterize the performance of a liquid-piston spray-cooled gas compressor. The working principle of the compressor enables optimized high-efficiency operation over a very wide range of operating conditions, unlike conventional compressors that are optimized for a narrow range of operating conditions. The compressor technology is suitable for many applications, such as gas pipeline transport, gas storage, and commercial and residential heat pumps. Both physical testing and computational fluid dynamics (CFD) modeling of the processes using the Oak Ridge National Laboratory high-performance computing center were completed. The experimental and CFD studies focused on a near-isothermal liquid-piston compressor (LPC) that uses propylene glycol to compress CO 2 . The first prototype demonstrated isothermal operation during several sequentially executed cycles of CO 2 compression and raised the temperature of the compressed CO 2 by only 2 K, compared with approximately 6 K when the gas was compressed non-isothermally. Isothermal operation was demonstrated at CO 2 flow rates of up to 2 L/min. The second prototype was designed with two compression chambers to allow continuous flow of high-pressure CO 2 . However, the design of the valve train to direct flow between the compression chambers was not sufficient to allow demonstration of CO 2 compression. Numerical simulations of the LPC in which the compression chamber was filled with propylene glycol injected from the bottom inlet were performed using large eddy simulation (LES) with the wall-adapting local eddy-viscosity subgrid-scale model coupled with the multiphase volume of fluid (VOF) model to simulate the transient interface between gas and liquid and to capture the heat and mass transfers within the compression chamber. In this effort, the effects of boundary conditions applied to the LES-VOF calculations (i.e., no wall, an adiabatic wall, and a wall with a heat flux subscribed) on the overall pressure and temperature of the CO 2 gas as well as the transient evolution of flow and heat transfer within the compression chamber were investigated and are discussed in this report. The LES calculation with no wall showed no dynamical flow patterns, and the volume-averaged temperature of CO 2 increased from 305 to 392.7 K, whereas LES calculations with a constant wall temperature or a wall heat flux had similar increases of CO 2 temperatures. The results of the LES simulation using a wall heat flux showed different stages in the compression process and revealed dynamical formation and interaction of CO 2 gas layers and circulation flow patterns within the chamber that contributed to the overall heat transfer between the solid wall, gas, and liquid surface in the compressor. Though an industrial partnership for commercializing the compressor was not secured, the technology was attractive for an industrial partner to use in two research proposals in response to US Department of Energy funding opportunity announcements.
Efforts to increase the efficiency of residential and commercial air conditioners and heat pumps have demonstrated that the compressor accounts for most of the system’s electrical energy usage. Therefore, the efficiency of this component should be improved to reduce its energy usage. The US Department of Energy’s Oak Ridge National Laboratory developed a near-isothermal liquid piston compressor (LPC) that uses propylene glycol (PG) to compress CO2. This report presents numerical studies of the LPC in which the compression chamber fills with injected PG from the bottom inlet. Numerical simulations were performed using the large-eddy simulation (LES) with the wall-adapting local eddy-viscosity (WALE) subgrid-scale model coupled with the multiphase volume-of-fluid (VOF) model to simulate the transient interface between gas and liquid and to capture the heat and mass transfer within the compression chamber. In this effort, effects of boundary conditions applied to the LES-VOF calculations (e.g., no wall, an adiabatic wall, and a wall with a heat flux subscribed) to the overall pressure and temperature of CO2 gas as well as the transient evolution of flow and heat transfer evolution within the compression chamber are investigated and discussed. It was found that the LES calculation with no wall have shown no dynamical flow patterns and the volume-averaged temperature of CO2 increased from 305 to 392.7 K, while LES calculations with a constant wall temperature or a wall heat flux had similar increases of CO2 temperatures. Results of LES simulation using a wall heat flux showed different stages in the compression process and revealed dynamical formation and interaction of CO2 gas layers and circulation flow patterns within the chamber that contribute to the overall heat transfer between the solid wall, gas, and liquid surface in the compressor.
Magnetohydrodynamic generator uses a slug or piston of liquid potassium as the working fluid. An expanding vapor of the metal is allowed to reciprocate the liquid-metal-piston through a magnetic field and the expansion energy is converted directly into electrical energy.
Compressors are the primary components of energy consumption in vapor compression systems, drawing considerable research effort to reduce carbon emissions and improve energy efficiency. This work presents an isothermal compressor that integrates the compression chamber with the gas cooler to achieve near-isothermal compression, resulting in up to 30% energy reduction compared to traditional isentropic compression, according to the experiment results. A detailed dynamic model for the isothermal compression cycle of carbon dioxide (CO 2 ) is first presented, coupled with a liquid-piston model for chamber design. The model is experimentally validated on a 3.5 kW prototype, yielding a 6.2% relative error in chamber pressure and a 0.5 K deviation in chamber temperature. The liquid piston exhibits reduced frictional heating and geometric adaptability relative to the mechanical piston. Leveraging these attributes, the study further evaluates approaches that enhance the heat transfer to achieve isothermal compression by increasing the effective heat transfer area during compression. As a result, simulations demonstrated up to a 5% improvement in the coefficient of performance over the baseline case through chamber design, providing guidelines for design of isothermal compression cycle.
Compressors are the major energy consumption components in vapor compression systems, drawing much research effort in reducing carbon emissions. The isothermal compressor integrates the compressor chamber and gas cooler to achieve near isothermal compression, reaching up to 30% energy reduction compared to the traditional isentropic compression work. This paper presents a detailed isothermal compressor model combined with a generalized liquid piston model to account for the carbon dioxide (CO2) isothermal compression process. The model is established based on MATLAB environment. The model uses the real experimental data as boundary conditions and initial settings, which also considers the CO2 solubility in liquid piston (mineral oil) for designing, optimizing and customizing the compression chambers. The validation was carried out with experimental data using a prototype with 3.5 kW capacity. The results have demonstrated the accuracy of the dynamic model (6.2% relative error for chamber pressure and 0.5 K deviation for chamber temperature), which provide a guideline for designing and customizing the isothermal compression cycle.
The compressor holds great promise for enhanced energy efficiency over a wide range of vapor compression systems (VCS). However, the majority of them focused on liquid refrigerant injection or inter-stage cooling technologies to improve heat transfer. Increasing the heat transfer area provides another perspective to promote heat dissipation, which commonly involves shape optimization whilst bringing some limitations, mainly from the manufacturing side. To fill the research gap, this paper compares the performance of isothermal compressors under different compression chamber shapes and chamber connection configurations. Additionally, the fluid control of the liquid piston was combined with shape optimization to explore the potential for further heat transfer enhancement. The simulation results have demonstrated that the COP improvements can reach up to 9% compared with the baseline case by optimizing the chamber shape and properly controlling the liquid piston speed, which provides a guideline for designing and customizing the isothermal compression chamber.
Compressors can be described as the heart of a vapor compression refrigeration system, circulating the working fluid in the system. Significant benefits can be gained from improving its efficiency since energy consumption is responsible for almost the entire system's power input. An effort has been made to achieve isothermal compression through liquid refrigerant injection or inter-stage cooling in refrigeration systems. In recent years, much effort has been invested into isothermal compression technology for air compressors or compressed air energy storage systems with the rise of renewable energy. Here, this work has explored the advancements made in this area and categorized them to discuss the benefits, limitations, and tradeoffs. Evidently, increasing heat transfer area is a significant aid in improving heat transfer, resulting in better isothermal compression. However, liquid pistons open more avenues for this to be pursued, and therefore, are limited to air compression applications. In addition, water injection proved to be the most effective among the methods. Finally, there is a need for more experimental research on refrigeration applications and the field is still in its infancy.
In efforts to increase the efficiency of residential and commercial air conditioners and heat pumps, it is found that the compressor has the highest electrical energy usage of the system. Therefore, it is appropriate to try to increase the efficiency of this component to reduce its energy usage. Another challenge with heat pump design is that some compressor types have drawbacks that make modulation difficult. To answer these challenges, we are developing an isothermal liquid compressor. The compressor uses propylene glycol to compress carbon dioxide. In the compression chamber the propylene glycol can enter either from the bottom to create a liquid piston for compression or it can enter through a spray nozzle at the top of the chamber. In the latter case, heat transfer from the gas to be compressed to the liquid droplets is high. This allows near isothermal operation of the compressor, which increases the efficiency by 17% to 30%, compared to adiabatic compression. In addition, the isothermal liquid compressor enables very efficient and simple part load modulation.Experimental results demonstrating the operation of the liquid compressor are presented. Initial data demonstrated a temperature rise of 7 K at pressure ratios of almost 4. For comparison at the same initial pressure, temperature, and pressure ratio, adiabatic compression would result in a temperature increase of approximately 70 K. Plotting data on a P-h diagram demonstrates that the compression started at superheated state and ended in supercritical state. Testing was later performed with repeated compressions in the superheated region of the P-h diagram at liquid flow rates of 2 x 10-3 m3/min and 2 x 10-3 m3/min to understand the limitations of the prototype for use with an actual heat pump system. This work demonstrated a novel cycle on a T-s diagram. Results from this work will be used to develop a second-generation prototype where more rapid cycling is possible.
The Thermal Energy Conversion Branch (5490) leads the way in designing, conducting, and implementing research for the newest thermal systems used in space applications at the NASA Glenn Research Center. Specifically some of the most advanced technologies developed in this branch can be broken down into four main areas: Dynamic Power Systems, Primary Solar Concentrators, Secondary Solar Concentrators, and Thermal Management. Work was performed in the Dynamic Power Systems area, specifically the Stirling Engine subdivision. Today, the main focus of the 5490 branch is free-piston Stirling cycle converters, Brayton cycle nuclear reactors, and heat rejection systems for long duration mission spacecraft. All space exploring devices need electricity to operate. In most space applications, heat energy from radioisotopes is converted to electrical power. The Radioisotope Thermoelectric Generator (RTG) already supplies electricity for missions such as the Cassini Spacecraft. The focus of today's Stirling research at GRC is aimed at creating an engine that can replace the RTG. The primary appeal of the Stirling engine is its high system efficiency. Because it is so efficient, the Stirling engine will significantly reduce the plutonium fuel mission requirements compared to the RTG. Stirling is also being considered for missions such as the lunar/Mars bases and rovers. This project has focused largely on Stirling Engines of all types, particularly the fluidyne liquid piston engine. The fluidyne was developed by Colin D. West. This engine uses the same concepts found in any type of Stirling engine, with the exception of missing mechanical components. All the working components are fluid. One goal was to develop and demonstrate a working Stirling Fluidyne Engine at the 2nd Annual International Energy Conversion Engineering Conference in Providence, Rhode Island.
Energy storage is essential for cost-effective integration of variable renewable energy sources to support a low-carbon grid. It is also a key enabler of a modern grid infrastructure for demand management. However, several main challenges remain for different kind of energy storage technologies in grid scale deployment. Currently, the largest source of utility-scale storage and long-duration storage in the US is pumped storage hydropower (PSH). Prospect of growth in conventional PSH faces challenges that have limited its deployment over the last three decades, including high capital costs and long deployment timelines. Batteries have high energy densities and are the primary technology of choice for small-scale energy storage. Compressed air energy storage (CAES) is another large-scale energy storage technology, but there are few plants deployed worldwide. They suffer from their low round trip efficiency (RTE) due to the use of high-pressure air compressors. To address some of the challenges associated with these various storage technologies, the Ground-Level Integrated Diverse Energy Storage (GLIDES) is a modular PSH technology that was invented in 2015 at Oak Ridge National Laboratory. It utilizes gas compression to store electric energy. GLIDES stores energy by compressing gas using a liquid piston in high-pressure vessels. In doing so the vessels act as the upper reservoir in conventional PSH. Initially, the vessels are filled with gas to a prescribed pressure. To store energy, GLIDES uses a hydraulic piston pump to pump water into the pressurized vessels. As the water volume increases inside the vessels, water acts as a hydraulic piston compressing the gas on top of it. This process can be thought of as pumping water from the lower reservoir to the higher reservoir in PSH, increasing the water head. To dispatch the stored energy, the high-head water in the vessel is discharge through a high head Pelton hydraulic turbine that is connected to an electric generator. Employing high-pressure vessels enables GLIDES to reach water heads ~10-80 times higher than conventional PSH, achieving ~40 times higher energy densities, and overcomes the geographic limitation of conventional PSH. Although its energy density is much lower than that of batteries, GLIDES holds the potential advantages of having long service life, ease of system integration and being less hazardous over batteries. GLIDES prospective scalability could make it suitable for wide range of applications from behind the meter storage in buildings to grid-scale storage. It also makes it suitable for installations in densely populated urban areas where energy storage is most needed and real estate is limited. Over the last 5 years, work has focused on increasing GLIDES’ energy density, decreasing its initial capital cost of the system, and increasing its revenue potential. Several designs were developed and prototyped to verify and demonstrate the improvement in energy density. The latest prototype achieved energy density of 1.21 kWh/m 3 . Our analysis showed that it could achieve up to 1.7 kWh/m 3 with a mixture of air and carbon dioxide as the gas being compressed.
To determine the effect of piston-head temperature on knock-limited power. Tests were made in a supercharged CFR engine over a range of fuel-air ratios from 0.055 to 0.120, using S-3 reference fuel, AN-F-28, Amendment-2, aviation gasoline, and AN-F-28 plus 2 percent xylidines by weight. Tests were run at a compression ratio of 7.0 with inlet-air temperatures of 150 F and 250 F and at a compression ratio of 8.0 with an inlet-air temperature of 250 F. All other engine conditions were held constant. The piston-head temperature was varied by circulation of oil through passages in the crown of a liquid-cooled piston. This method of piston cooling decreased the piston-head temperature about 80 F. The data are not intended to constitute a recommendation as to the advisability of piston cooling in practice.
The NASA Engineering and Safety Center (NESC) has developed an analytical model that predicts diffusion between two gases during piston purging of liquid hydrogen (LH2) tanks. This model helps explain dramatic helium savings seen in a recent Kennedy Space Center (KSC) purge, shows that undesired turbulent mixing occurred in Space Shuttle External Tank purges, and is applicable to future helium purges of the Space Launch System Core Stage LH2 tanks.
General Fusion (GF) is developing an adaptable, commercial fusion power plant based on magnetized target fusion (MTF). The GF approach involves forming a spherical torus of deuterium-tritium plasma in a large (~4 m diameter) cavity formed in liquid metal, and then collapsing that cavity with an array of pneumatic piston drivers. The liquid metal is constantly flowing through the fusion chamber and out to processing systems where tritium and heat will be extracted using tritium extraction technologies and heat exchangers, respectively. Here, this study focuses on two candidate designs for the liquid metal blanket and first wall material for the General Fusion Magnetized Target Fusion (GF MTF) power plant and assesses their impact on the tritium fuel cycle. The first candidate is the lead lithium eutectic (LLE) and the second candidate is pure lithium (Li). It was found that the main differences between LLE and Li designs are the extraction technologies required to remove tritium from the blanket and the amount of tritium and its distribution within the facility. More than 80% of the in-process tritium inventory for the LLE design is contained in the isotope separation system, while for the Li design, over 60% of the in-process tritium inventory is contained within the blanket material. This is due to significant tritium retention by Li. For the Li blanket, the burden of tritium processing rests on the blanket extraction technology rather than the traditional exhaust processing route. Thus, the blanket extraction technology is a main driver of tritium inventory in the Li system and determines the subsequent interface with the tritium processing plant.
An apparatus denoted a swab device has been developed as a convenient means of acquiring samples of contaminants from surfaces and suspending the samples in liquids. (Thereafter, the liquids can be dispensed, in controlled volumes, into scientific instruments for analysis of the contaminants.) The swab device is designed so as not to introduce additional contamination and to facilitate, simplify, and systematize the dispensing of controlled volumes of liquid into analytical instruments. The swab device is a single apparatus into which are combined all the equipment and materials needed for sampling surface contamination. The swab device contains disposable components stacked together on a nondisposable dispensing head. One of the disposable components is a supply cartridge holding a sufficient volume of liquid for one complete set of samples. (The liquid could be clean water or another suitable solvent, depending on the application.) This supply of liquid is sealed by Luer valves. At the beginning of a sampling process, the user tears open a sealed bag containing the supply cartridge. A tip on the nondisposable dispensing head is engaged with a Luer valve on one end of the supply cartridge and rotated, locking the supply cartridge on the dispensing head and opening the valve. The swab tip includes a fabric swab that is wiped across the surface of interest to acquire a sample. A sealed bag containing a disposable dispensing tip is then opened, and the swab tip is pushed into the dispensing tip until seated. The dispensing head contains a piston that passes through a spring-loaded lip seal. The air volume displaced by this piston forces the liquid out of the supply cartridge, over the swab, and into the dispensing tip. The piston is manually cycled to enforce oscillation of the air volume and thereby to cause water to flow to wash contaminants from the swab and cause the resulting liquid suspension of contaminants to flow into the dispensing tip. After several cycles to ensure adequate mixing, liquid containing the suspended contaminant sample is dispensed. The disposable components are then removed from the dispensing head, which may then be reused with a fresh set of disposable components.