Lithium-drifted silicon detectors as low-energy photon spectrometers
Fabrication and testing of lithium-drifted detectors as low energy photon spectrometers
SEARCH · Search NASA
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Fabrication and testing of lithium-drifted detectors as low energy photon spectrometers
Response of lithium-drifted silicon detectors for radiobiologic applications
Response of lithium-drifted silicon detectors to high energy alpha and proton beam and radiobiologic application
Electron irradiation effect on resolution of lithium-drifted silicon semiconductor detectors
Theory, characteristics, and fabrication of lithium-drifted silicon detectors
By making use of the signature of a gamma ray event as it appears in N = 5 to 20 lithium-drifted silicon detectors and applying smart selection algorithms, gamma rays in the energy range of 1 to 8 MeV can be detected with good efficiency and selectivity. Examples of the types of algorithms used for different energy regions include the simple sum mode, the sum-coincidence mode used in segmented detectors, unique variations on sum-coincidence for an N-dimensional vector event, and a new and extremely useful mode for double escape peak spectroscopy at pair-production energies. The latter algorithm yields a spectrum similar to that of the pair spectrometer, but without the need of the dual external segments for double escape coincidence, and without the large loss in efficiency of double escape events. Background events due to Compton scattering are largely suppressed. Monte Carlo calculations were used to model the gamma ray interactions in the silicon, in order to enable testing of a wide array of different algorithms on the event N-vectors for a large-N stack.
We present Monte Carlo analysis and experimental data from a novel lithium-drifted silicon detector stack for gamma ray spectroscopy instrumentation in future Mars surface landers and other planetary missions. The Monte Carlo analysis shows full energy photopeaks even in the range of about 100 keV to 2 MeV where, in Si, Compton scattering dominates the absorption processes. Laboratory data is shown for an experimental detector stack of four planar Si(Li) devices, each 5 mm thick with an active area 2 cm in diameter. All the experimental data were collected with maximum temperature of the stack at 175 K. Background reduction is achieved by using the detector of the stack closest to the source in anticoincidence. We present a comparison of experimental data from the stack with the Monte Carlo model for Cs-137 (662 keV). Agreement is shown to be good, with a full energy photopeak clearly seen (FWHM about 10 keV). Experimental stack data is also shown for multiple peaks at 511 keV (Na-22) and 662 keV (Cs-137). The peaks are clearly resolved (FWHM 10 keV), and are compared with the results obtained using a 8 percent resolution, 3 in. x 3 in. NaI(TI) device (FWHM about 50 keV).
Activities directed toward the development of methods of measurement for semiconductor materials, process control, and devices are described. Topics investigated include: measurements of transistor delay time; application of the infrared response technique to the study of radiation-damaged, lithium-drifted silicon detectors; and identification of a condition that minimizes wire flexure and reduces the failure rate of wire bonds in transistors and integrated circuits under slow thermal cycling conditions. Supplementary data concerning staff, standards committee activities, technical services, and publications are included as appendixes.
A technique was developed for preparing solid state, lithium-drifted silicon detectors. Hollow cylindrical detectors were built and tested for possible use as anticoincidence shields to replace conventional plastic scintillators and photomultipliers. A fission cell was developed for the Pioneer F/G instruments and the IMP I subsystem. An electron current detector was developed for Jovian belt measurements of electron flux. A number of circuits and semiconductor devices was also developed.
A soft X-ray, 0.3-1.0 keV spectrum from a 1 sr region which includes a portion of the North Polar Spur, obtained by three rocketborne lithium-drifted silicon detectors, shows the C V, C VI, O VII and O VIII emission lines. The spectrum is well fitted by a two-component, modified Kato (1976) model, where the coronal emission is in collisional equilibrium, with interstellar medium and North Polar Spur temperatures of 1.1 and 3.8 million K, respectively.
Fluctuations of energy loss by charged particles in lithium-drifted silicon semiconductor detectors
In this study, a new conversion electron detector has been commissioned at the ATLAS/ CARIBU facility at Argonne National Laboratory. The LSU-Argonne Conversion Electron Spectrometer (LACES) is a LN 2 -cooled Si(Li) detector system designed to be incorporated into a decay station that comprises the dedicated HPGe clover array with a box geometry (X -Array) and the Scintillator and Tape Using Radioactive Nuclei (SATURN) device. This integration enables simultaneous measurements of conversion electrons and gamma-rays in decay experiments, yielding novel information on transition multipolarities, electric monopole transitions, and isomeric states that decay mostly via conversion electrons. A measurement of the energy resolution of LACES yielded 2.3-keV FWHM at 975 keV for electrons and 1.3-keV FWHM at 75 keV for X-rays. A detailed study of the absolute detection efficiency (at 5 mm from the source) was performed, where this quantity was determined experimentally in the range of electron transition energies between 25.5 keV and 1047.8 keV and subsequently simulated using the GEANT4 code. Measurement and simulations are found to be in excellent agreement. A precise characterization, for this type of detector system, of the absolute detection efficiency for such a wide energy range is reported for the first time.
This work describes the experimental results obtained from the characterization of a 32-channels readout ASIC that is the core of a module composed by 4 Lithium-drifted Silicon, Si(Li), detectors. The module is the building block of a tracker in an upcoming balloon experiment. The activity is carried out within the General AntiParticle Spectrometer (GAPS) international collaboration, whose objective is the indirect detection of dark matter through the detection of antiparticles present in cosmic rays at low energies. The balloon flight is foreseen in 2024 from the McMurdo station in Antarctica. The ASIC is designed in a 180 nm CMOS technology and has 32 low-noise analog readout channels featuring a dynamic compression of the signal, an 11-bit SAR ADC, and a digital back-end section responsible for channel setting and for sending digital information to the data acquisition system of the tracker. This work has a twofold goal: it intends on the one hand to verify the performance of the circuit, on the other to select at least 300 good samples to be used for the assembly of the GAPS Si(Li) tracker.
Here this work describes the architecture and the experimental results from the characterization of a 32-channels mixed-signal Application-Specific Integrated Circuit (ASIC) developed for the readout of the lithium-drifted silicon, Si(Li), detectors of the General AntiParticle Spectrometer (GAPS) experiment dedicated to searching for dark matter. The instrument is designed for the identification of antiprotons, antideuterons and antihelium nuclei from cosmic rays during an Antarctic balloon mission scheduled for late 2024. A full custom integrated circuit, named SLIDER32 (32-channels Si-LI DEtector Readout) ASIC, has been produced in a commercial 180 nm CMOS technology. The ASIC is comprised of 32 low-noise analog readout channels featuring dynamic signal compression to comply with the wide input range, an 11-bit SAR ADC and a digital back-end section which is responsible for channel setting and for sending digital information to the data acquisition system (DAQ). The circuit design criteria and the experimental results are discussed in the paper.
Here, this work describes the architecture and the experimental results from the characterization of the lithium-drifted silicon (Si(Li)) detector module, which constitutes the building block of the tracker in the general antiparticle spectrometer (GAPS) experiment to search for dark matter. The instrument is designed for the identification of low-energy cosmic anti-nuclei (antiprotons, antideuterons, and antihelium) to be performed during an Antarctic long-duration balloon flight scheduled for late 2025. The GAPS Si(Li) tracker, that is the core of the instrument, is the assembly of 252 modules, each comprised of four Si(Li) detectors and a full custom-integrated circuit designed for detector readout and produced in a commercial 180-nm planar CMOS technology. A general overview of the detector module architecture and its components is provided, together with a description of the test setup and the experimental results obtained from the characterization of the low-noise analog readout channel. In order to verify the effective operation of the entire module, results concerning the detection of X-rays from a 241Am source and cosmic muons are also provided.
High-resolution lithium-drifted silicon and germanium detectors for measuring line widths of 2p-1s transitions in low-Z pionic atoms
We report on extensive tests of large-area (10cm diameter) high-purity ion-implanted silicon detectors for th Solar Isotope Spectrometer (SIS), and lithium-drifted silicon detetors for the Cosmic Ray Isotope Spectrometer (CRIS), which are under development for launch on the Advanced Composition Explorer (ACE) mission.
The research to define an energetic particle experiment for the OPTGT-MJS missions is reported. The studies reported include: (1) the use of silicon dectectors for low energy, low flux level measurements in the presence of RTG radiation and trapped electrons, (2) high energy proton damage of lithium-drifted and surface barrier silicon detectors, (3) the gas Cerenkov counter, (4) systems for detection of trapped high-energy protons in the presence of trapped electrons, and (5) reliability and redundancy.