Search NASA⌕ Search

SEARCH · Search NASA

Results for “Load Data”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Load Profile Inpainting for Missing Load Data Restoration and Baseline Estimation

This paper introduces a Generative Adversarial Nets (GAN) based, Load Profile Inpainting Network (Load-PIN) for restoring missing load data segments and estimating the baseline for a demand response event. The inputs are time series load data before and after the inpainting period together with explanatory variables (e.g., weather data). Here, we propose a Generator structure consisting of a coarse network and a fine-tuning network. The coarse network provides an initial estimation of the data segment in the inpainting period. The fine-tuning network consists of self-attention blocks and gated convolution layers for adjusting the initial estimations. Loss functions are specially designed for the fine-tuning and the discriminator networks to enhance both the point-to-point accuracy and realisticness of the results. We test the Load-PIN on three real-world data sets for two applications: patching missing data and deriving baselines of conservation voltage reduction (CVR) events. We benchmark the performance of Load-PIN with five existing deep-learning methods. Our simulation results show that, compared with the state-of-the-art methods, Load-PIN can handle varying-length missing data events and achieve 15-30% accuracy improvement.

14 SOLAR ENERGY↗

Using Utility Load Data to Estimate Demand for Space Cooling and Potential for Shiftable Loads

This paper describes a simple method to estimate hourly cooling demand from historical utility load data. It compares total hourly demand to demand on cool days and compares these estimates of total cooling demand to previous regional and national estimates. Load profiles generated from this method may be used to estimate the potential for aggregated demand response or load shifting via coldstorage.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Trend of tunnel magnetoresistance and variation in threshold voltage for keeping data load robustness of metal–oxide–semiconductor/magnetic tunnel junction hybrid latches

The robustness of data load of metal–oxide–semiconductor/magnetic tunnel junction (MOS/MTJ) hybrid latches at power-on is examined by using Monte Carlo simulation with the variations in magnetoresistances for MTJs and in threshold voltages for MOSFETs involved in 90 nm technology node. Three differential pair type spin-transfer-torque-magnetic random access memory cells (4T2MTJ, 6T2MTJ, and 8T2MTJ) are compared for their successful data load at power-on. It is found that the 4T2MTJ cell has the largest pass area in the shmoo plot in TMR ratio (tunnel magnetoresistance ratio) and V{sub dd} in which a whole 256 kb cell array can be powered-on successfully. The minimum TMR ratio for the 4T2MTJ in 0.9 V < V{sub dd} < 1.9 V is 140%, while the 6T2MTJ and the 8T2MTJ cells require TMR ratio larger than 170%.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Improving the Accuracy of Clustering Electric Utility Net Load Data using Dynamic Time Warping

Identifying patterns in electric utility net load data in a time-series format is very useful in preparing the operation for next day. Machine learning algorithms have been used in other domains and those concepts are applied in this paper on real-world net load measurement data. Clustering is the practice of grouping data with similar characteristics as determined by the distance measure. The K-means clustering algorithm is utilized here with actual electric utility data. The paper uses the standard distance measure, Euclidean distance (ED), and compares its performance against the dynamic time warping (DTW) measure. An actual case study with real data is presented, and DTW distance measure-based method observed to result better accuracy compared to the ED based method for substation net load measurements predominantly with residential customers.

clustering↗

Extracting Operating Modes from Building Electrical Load Data: Preprint

Empirical techniques for characterizing electrical energy use now play a key role in reducing electricity consumption, particularly miscellaneous electrical loads, in buildings. Identifying device operating modes (mode extraction) creates a better understanding of both device and system behaviors. Using clustering to extract operating modes from electrical load data can provide valuable insightsinto device behavior and identify opportunities for energy savings. We present a fast and effective heuristic clustering method to identify and extract operating modes in electrical load data.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Enriching Load Data Using Micro-PMUs and Smart Meters

In modern distribution systems, load uncertainty can be fully captured by micro-PMUs, which can record high-resolution data; however, in practice, micro-PMUs are installed at limited locations in distribution networks due to budgetary constraints. In contrast, smart meters are widely deployed but can only measure relatively low-resolution energy consumption, which cannot sufficiently reflect the actual instantaneous load volatility within each sampling interval. In this paper, we have proposed a novel approach for enriching load data for service transformers that only have low-resolution smart meters. The key to our approach is to statistically recover the high-resolution load data, which is masked by the low-resolution data, using trained probabilistic models of service transformers that have both high- and low-resolution data sources, i.e., micro-PMUs and smart meters. The overall framework consists of two steps: first, for the transformers with micro-PMUs, a Gaussian Process is leveraged to capture the relationship between the maximum/minimum load and average load within each low-resolution sampling interval of smart meters; a Markov chain model is employed to characterize the transition probability of known high-resolution load. Next, the trained models are used as teachers for the transformers with only smart meters to decompose known low-resolution load data into targeted high-resolution load data. The enriched data can recover instantaneous load uncertainty and significantly enhance distribution system observability and situational awareness. Here, we have verified the proposed approach using real high- and low-resolution load data.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Wind and structural loads data measured on parabolic trough solar collectors at an operational power plant

Abstract Wind loading is a primary contributor to structural design costs of concentrating solar-thermal power collectors, such as heliostats and parabolic troughs. These structures must resist the mechanical forces generated by turbulent wind, while the reflector surfaces must maintain optimal optical performance. Studying wind-driven loads at a full-scale, operational concentrating solar-thermal power plant provides insights into the wind impact on the solar collector field beyond the capabilities of wind tunnel tests or state-of-the-art simulations. We conducted comprehensive field measurements of the atmospheric turbulent wind conditions and the resulting structural wind loads on parabolic troughs at the Nevada Solar One plant over a two-year period. The measurement setup included meteorological masts and structural load sensors on four trough rows. Additionally, a lidar scanned the horizontal plane above the trough field. In this study, we describe the high-resolution dataset characterizing the complex flow field and resulting structural loads. This first-of-its-kind dataset will enhance the understanding of wind loading on collector structures and will help in designing the next-generation solar collectors and photovoltaic trackers.

14 SOLAR ENERGY↗

Summary of New Los Alamos National Laboratory Groundwater Data Loaded in July 2012

This report provides information concerning groundwater monitoring data obtained by the Los Alamos National Laboratory under its interim monitoring plan and contains results for chemical constituents that meet seven screening criteria laid out in the Compliance Order on Consent. Tables are included in the report to organize the findings from the samples. The report covers groundwater samples taken from wells or springs that provide surveillance of the groundwater zones indicated in the table.

54 ENVIRONMENTAL SCIENCES↗

NSO Processing Scripts (NSO wind loading data set processing scripts) [SWR-23-86]

NREL conducted comprehensive field measurements of the atmospheric turbulent wind conditions and the resulting structural wind loads on parabolic troughs at the Nevada Solar One plant from October 2021 to June, 2023. The measurement set-up included meteorological masts and structural load sensors on four trough rows. Additionally, NREL commissioned a lidar scanning the horizontal plane over the trough field. The high-resolution data set, characterizing the complex flow field and resulting structural loads, is available at https://data.openei.org/submissions/5938. The processing routines published here were used to create the data from the instruments' raw data.

Egerer, Ulrike↗

Community Geothermal: Soil Conductivity, Borehole Design, Energy Models, and Load Data for a Residential System Development - Hinesburg, VT

This dataset contains materials from the Coalition for Community-Supported Affordable Geothermal Energy Systems (C2SAGES) project, which evaluated the techno-economic feasibility of a community geothermal system for a residential development in Hinesburg, VT. The dataset includes detailed soil conductivity test reports, energy models, borehole design reports, hourly energy loads for heating, cooling, and hot water, and design layouts. EnergyPlus was used to model building energy loads, and Modelica software was applied for geothermal loop sizing based on these loads and soil conductivity results. Python scripts for network design further refined the models. Key files include PDF reports on borehole design (with projections for 1-year, 15-year, and 30-year systems), soil conductivity test results, EnergyPlus modeling outputs, and 2D/3D design drawings in PDF, DWG, and DXF formats. Python notebooks for network design and OnePipe model files are also provided, with Modelica required for viewing certain files. Outputs and modeling data are in various formats including CSV, JPG, HTML, and IDF, with units and data clearly labeled to support understanding of system design and performance for the proposed geothermal solution.

15 GEOTHERMAL ENERGY↗

Analysis of ICRH antenna loading data in TEXTOR obtained during gas injection experiments

The possibility of increasing the coupling of ICRH power to plasmas on TEXTOR by gas injection was investigated, for a given voltage applied at the input of an antenna pair. The antenna pair was operated in the conjugated T mode, D(H) heating was used. Modeling of the antenna by transmission line theory shows that load resilience is maintained in a broad range of independent resistance variation for each strap. It is found that the absolute value of the reflection coefficient can be maintained below 0.2 for typical values of resistance measured in plasma shots (2-10 {Omega}/m) in good matching conditions. During gas injection, the loading resistance showed a clear increase with increasing line average electron density measured close to the plasma edge. Evidence of fast wave eigenmodes was also found, as characteristic resonant behavior of loading resistance and antenna self-inductance, due to poor absorption in the plasma caused by high H minority concentration.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Extreme Efficiency 240 Vac to Load Data Center Power Delivery Topologies and Control

The research explored innovative new circuit topologies and power converter architectures for data center power delivery, from the 240 V ac voltage at the input of a server rack, down to the less than 1 V dc power supply of the latest microprocessors. The research pursued three parallel tracks to increase the power conversion efficiency and to reduce the overall size of the servers: 1) An innovative new ac-dc power converter topology which enables improved efficiency through use of a novel direct step-down topology, well suited for the popular 48V dc power distribution. 2) A new series-stacked power delivery approach for servers comprising a large number of similar loads, such as hard drives in storage servers. The approach greatly reduces the power conversion losses, and achieves efficiency well over 99%. 3) A new family of hybrid switched-capacitor power converters that enable improved efficiency and reduced size through the use of dense ceramic capacitors and new circuit topologies that leverage GaN and low-voltage Si transistor technology. Together, the accomplished research achieved the goal of reducing the power conversion losses in datacenters, thereby reducing greenhouse gas emissions, operating costs, and overall electricity consumption.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Load Data for Mk279 Projectiles

This document details the resulting velocity of Mk279 Mod1 projectiles when fired from a RD24 barrel with between 15 and 110 grains of smokeless propellant to achieve velocities between 163 and 651m/s.

45 MILITARY TECHNOLOGY, WEAPONRY, AND NATIONAL DEF↗

Data-Driven Residential Load Modeling and Validation in GridLAB-D

Accurately characterizing the impacts of high penetrations of distributed energy resources (DER) on the electric distribution system has driven modeling methods from traditional static snap shots, often representing a critical point in time (e.g., summer peak load), to quasi-static time series (QSTS) simulations capturing all the effects of variable DER, associated controls and hence, impacts on the distribution system over a given time period. Unfortunately, the high time resolution DER source and load data required for model inputs is often scarce or non-existent. This paper presents work performed within the GridLAB-D model environment to synthesize, calibrate, and validate 1-second residential load models based on measured transformer loads and physics-based models suitable for QSTS electric distribution system modeling. The modeling and validation approach taken was to create a typical GridLAB-D model home that, when replicated to represent multiple diverse houses on a single transformer, creates a statistically similar load to a measured load for a given weather input. The model homes are constructed to represent the range of actual homes on an instrumented transformer: square footage, thermal integrity, heating and cooling system definition as well as realistic occupancy schedules. House model calibration and validation was performed using the distribution transformer load data and corresponding weather. The modeled loads were found to be similar to the measured loads for four evaluation metrics: 1) daily average energy, 2) daily average and standard deviation of power, 3) power spectral density, and 4) load shape.

24 POWER TRANSMISSION AND DISTRIBUTION↗