Search NASA⌕ Search

SEARCH · Search NASA

Results for “Load estimate”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

PR100: Estimated Medium- and Heavy-Duty Electric Vehicle Adoption and Load Estimation in Puerto Rico through 2050

The 2-year Puerto Rico Grid Resilience and Transition to 100% Renewable Energy Study analyzed stakeholder-driven pathways to Puerto Rico’s clean energy future. Outputs relating to electricity demand modeling were partially informed by estimates of electric vehicle adoption across all classes of medium- and heavy-duty vehicles (MHDVs), and the ensuing charging loads. To create these estimates, the team developed a transportation model for MHDVs in Puerto Rico to estimate the amount and geospatial distribution of energy used. Charging schedules for the different end uses of MHDVs were then used to construct electric load shapes assuming a portion of those vehicles would be replaced by battery electric counterparts. Study results showed that, by 2050, electric vehicles may constitute roughly 50% of the MHDV population in Puerto Rico. The resulting electrical demand curve attributable to MHDV charging showed that, for solar energy-based electrical systems with limited energy storage, this demand may create challenges unless appropriately managed either on the demand or supply side.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

A Stochastic Framework for Estimating Load Profiles at EV Fast Charging Stations

This paper formulates a methodology for estimating the average daily load profiles of EV fast charging stations over a planning horizon of five to ten years. The developed methodology uses historic vehicle registration data, state-level EV adoption targets, seasonal driving patterns, local demographics, competition, and traffic volume information to predict average station usage. Through Monte Carlo simulations, an average daily load profile is obtained for each month in the planning horizon, and prediction uncertainty is quantified. The proposed framework will facilitate the accurate estimation of energy and demand costs incurred by the charging station over the planning period, thereby informing return-on-investment calculations.

Biswas, Shuchismita↗

Fluid temperature predictions of geothermal borefields using load estimations via state observers

Fluid temperature predictions of geothermal borefields usually involves temporal superposition of its characteristic g-function, using load aggregation schemes to reduce computational times. Assuming that the ground has linear properties, it can be modeled as a linear state space system where the states are the aggregated loads. However, the application and accuracy of these models is compromised when the borefield is already operating and its load history is not registered or there are gaps in the data. This paper assesses the performance of state observers to estimate the borefield load history and obtain accurate fluid predictions. Results show that both Time-Varying Kalman Filter (TVKF) and Moving Horizon Estimator (MHE) provide predictions with average and maximum errors below 0.1 $^\circ C$ and 1 $^\circ C$ respectively. MHE outperforms TVKF in terms of n-step ahead output predictions and load history profile at the expenses of about 5 times more computational time.

Figueroa, Iago C.↗

Divertor heat load estimates on NSTX and DIII-D using new and open-source 2D inversion analysis code

A thermography inversion algorithm has been developed in the open-source Python-based computer code, HYPERION, to calculate the heat flux incident on plasma-facing components (PFCs) in axisymmetric tokamaks. The chosen mesh size at the surface significantly affects the calculated transient heat flux results. The calculated transient heat flux will exceed the real value when the mesh size tends to zero but will underestimate the real value when the mesh size is large. A criterion for determining the appropriate mesh size for the transient heat flux calculation will be discussed. The numerical scheme for HYPERION uses a 2D fully implicit finite-difference approach, allowing temperature-dependent thermal properties of PFC materials. The inversion algorithm is benchmarked against established heat flux calculation codes, TACO and THEODOR, based on thermography data from NSTX and DIII-D respectively. The primary benefits of HYPERION compared to TACO and THEODOR are that it is open-source and it allows for the optimization of mesh thickness along the substrate. The algorithm also accounts for the thermal properties of thin surface layers that characteristically form on PFCs due to plasma-material interactions. The agreement between HYPERION and THEODOR is excellent, as the percent difference between the codes is ~5% on average in the case of the DIII-D data for moderate to high heat flux. Verification tests with TACO show slightly higher average percent differences of 8% and 12%. In using HYPERION to study filaments in heat flux, the initial results indicate that small ELMs filaments significantly broaden the divertor heat flux, and decrease divertor peak flux. Compared to the inter-ELM, the small ELM filaments decrease the divertor peak surface temperature. With intermittent divertor filaments, the divertor heat flux width is comparable with that found in L-mode.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Augmented Kalman filter with a reduced mechanical model to estimate tower loads on a land-based wind turbine: a step towards digital-twin simulations

This article presents an application of the Kalman filtering technique to estimate loads on a wind turbine. The approach combines a mechanical model and a set of measurements to estimate signals that are not available in the measurements, such as wind speed, thrust, tower position, and tower loads. The model is severalfold faster than real time and is intended to be run online, for instance, to evaluate real-time fatigue life consumption of a field turbine using a digital twin, perform condition monitoring, or assess loads for dedicated control strategies. The mechanical model is built using a Rayleigh–Ritz approach and a set of joint coordinates. We present a general method and illustrate it using a 2-degrees-of-freedom (DOF) model of a wind turbine and using rotor speed, generator torque, pitch, and tower-top acceleration as measurement signals. The different components of the model are tested individually. The overall method is evaluated by computing the errors in estimated tower-bottom-equivalent moment from a set of simulations. From this preliminary study, it appears that the tower-bottom-equivalent moment is obtained with about 10 % accuracy. The limitation of the model and the required steps forward are discussed.

17 WIND ENERGY↗

Model predictive control for matrix converter operating in current control mode with load current estimation

A matrix converter system operating in current control mode is provided. The matrix converter includes a switching matrix coupled between a low voltage side and a high voltage side, wherein the matrix converter is coupled at its low voltage side to a generator for receiving an input power including an input current and transforming the input power into an output power at its high voltage side, wherein a load is coupled to the high voltage side. The control system includes a load observer and a model predictive controller (MPC). The load observer is configured to estimate a load current that flows to the load from the high voltage side of the matrix converter as a function of a switching state of the switching matrix, an output voltage output at the high voltage side of the matrix converter, and the input current. The MPC is configured to select the switching state of the switching matrix to meet one or more control objectives defined by minimization of a multi-objective function that tracks the output voltage and the input current using the estimated load current.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Grey-box modeling and application for building energy simulations - A critical review

Grey-box modeling, as one of the three fundamental modeling techniques for building energy models, has many advantages compared with black-box modeling and white-box modeling. Additionally, it has been widely applied to solve problems of building technologies, such as building load estimation, control and optimization, and building-grid integration. However, a thorough review of grey-box modeling is not available. This review study systematically investigated various aspects of grey-box modeling for buildings. First, the fundamental aspects of grey-box modeling are presented, including the theoretical background, modeling of building elements, modeling order, modeling diagram, and order reduction. Second, the detailed modeling approaches are discussed. Third, multiple applications of grey-box modeling are investigated for building energy domain, which are categorized into the following groups: heat dynamics analysis, thermal load estimation, building control and optimization, district/urban scale energy modeling, and building-grid integration. Finally, the available software packages for grey-box modeling are compared. Overall, the challenges of using grey-box modeling can be summarized as follows: (1) the theoretical limitations and assumptions of grey-box modeling are unclear; (2) grey-box model naming convention and structure are confusing; (3) grey-box model creation is vague; (4) suitable applications of grey-box models are unknown; and (5) grey-box models lack unified software solutions for wider adoption.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

National Dataset of EV Charging Stations With Estimates of Load and Vehicle Throughput

Current data from the AFDC provide locations and many details about EV charging stations, but not estimates of their peak loads or the number of vehicles they can accommodate. This dataset will augment the AFDC charging station locations with estimates of transmission load and vehicle throughput based on engineering specifications of the chargers, charging patterns based on vehicle types, battery capacities, and user behavior.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Influence of sampling frequency and estimation method on phosphorus load uncertainty in the Western Lake Erie Basin, Ohio, USA

Accurate estimates of nutrient loads are necessary to identify critical source areas and quantify the impact of management practices on pollutant export. Previous studies have investigated nutrient load estimate uncertainty, but they often focus on nutrient loads estimated using an interpolation method for large-scale watersheds with short-term datasets. The study objective was to quantify uncertainty in soluble reactive phosphorus (SRP), total phosphorus (TP), and suspended solids (SS) load estimates from two small (<10 3 km 2 ) agricultural watersheds in the western Lake Erie Basin resulting from different sampling frequencies. Each watershed had high temporal resolution datasets of discharge (15 min) and nutrient concentration (1 to 3 samples per day) collected over a 30-year period (1990–2020). Firstly, SRP, TP, and SS loads were calculated using the high temporal resolution datasets, which was assumed as “true loads”. Secondly, the high temporal concentration data were decomposed to semiweekly, weekly, biweekly, and monthly sampling and annual loads were estimated using four common load estimation methods to assess the effect of sampling frequency and load estimation method on load estimate error. Across the four different methods, the composite method had the lowest relative root mean square and absolute bias, but the rectangular interpolation method was the most precise. Furthermore, even with semiweekly sampling, the composite method resulted in an unacceptable level of precision (average imprecision = 39 %), while the interpolation method resulted in an unacceptable bias (average absolute bias = 16 %). Because neither method could provide acceptable accuracy and precision at the lowest decrease in sampling (e.t. semiweekly sampling), continued daily sampling is recommended in these watersheds.

54 ENVIRONMENTAL SCIENCES↗

AGGREGATE: dAta-driven modelinG preservinG contRollable dEr for outaGe mAnagemenT and rEsiliency (Final Report)

The AGGREGATE project team successfully developed and validated various modules for outage management. Brief summaries of each module are provided to showcase their strength for outage management and restoration for a distribution system with a high penetration of connected distribution energy resources (DERs). In recent years, inverter-based DERs have been widely deployed in distribution system. A most of behind-the-meter (BTM) solar power generation is not visible to the utility. The data-driven DER and load estimation modules are using machine learning (ML) and artificial intelligence (AI) to manage this issue, which provides an opportunity for distribution system operators (DSOs) to operate systems and make decisions in real-time for a distribution system with a high penetration of DERs deployed. Also, the estimated DER and true load can be further leveraged in network aggregation and cold-load pick up estimation for reducing the computing complexity and providing for fast restoration. After load demand and DER power generations have been estimated, the information will support topology and state estimation (SE). The topology estimation module demonstrated the viability of mixed integer linear programming (MILP) formulation to estimate the most likely operational radial topology and outage sections using power flow measurements, historical/estimated load and DERs data and smart meter ping measurements. Formulation includes continuous (power flow, load and DERs data) and binary measurements (smart meter ping measurements) in a single formulation. Errors in continuous data and binary data are modeled as normal distribution and Bernoulli distribution, respectively. In the future distribution grid, the power injection from controllable DERs will be essential for efficient and resilient grid operation. However, determining the optimal DER injections and restoration actions is dependent on knowledge of the system states. State estimation (SE), already the cornerstone of transmission energy management systems, will become commonplace in distribution management systems as more measurements become available from deployment of automated metering infrastructure (AMI). Observability analysis is the first step in SE, as it determines the sufficiency of the available measurements for accurately estimating the current system states. A new type of pseudo-measurement called a Correlational Measurement (CM) is introduced in this module, to enhance the observability of the system to enable more accurate SE. CMs encapsulate knowledge of correlation between demand patterns for similar classes of loads as well as injection patterns for same-technology renewable DERs. During grid contingency scenarios, DERs have been traditionally disconnected, without any fault ride-through capabilities. However, with new regulations and better technology, it is feasible for these resources to contribute to the grid’s restoration after an adverse event and hence enhance resilience. The controllability module proposes a two-step restoration scheme for the power system restoration process by leveraging additional degrees of freedom in power electronics interfaced DERs for mitigating voltage problems. In a resilience mode without the utility system, the distribution grid relies on DERs to serve critical load. In such a severe event with multiple faults on the distribution feeders, actuation of various protective devices (PDs) divides the distribution system into electrical islands. The undetected actuated PDs due to fault current contributions from DERs can delay the restoration process, thereby reducing the system resilience. The Advanced Outage Management (AOM) and the Advanced Feeder Restoration (AFR) modules developed in this project provide improved system resilience with multiple DERs. AOM identifies the faulted sections and actuated PDs in a distribution system with DERs by incorporating smart meter data. The most credible outage scenario including fault locations, PD actuations, and fault indicator (FI) failures is identified by a set of binary integer linear programming incorporating hypotheses. The AFR module serves to restore a distribution system with available energy resources taking into consideration the availability of utility sources and DERs. By partitioning the system into islands, critical load will be served with the available generation resources within islands based on the solution of a MILP. When the utility systems become available, the optimal path will be determined by a spanning tree search algorithm that reconnects these islands back to substations and restores the remaining load. The transmission and distribution (T&D) co-simulation module was used to validate the effect of a control action performed on the distribution side assets as it propagates to the transmission side. This ensures that the control action performed results in a feasible operating point on both the transmission and the distribution system. In addition to validation, the team used the T&D co-simulation module to demonstrate how distribution system assets can be used to mitigate issues on the transmission system. Specifically, the team demonstrated that appropriate switching operations on the distribution side can alleviate the line overload condition on the transmission side without causing new operational constraint violations.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Distributed Outage Detection in Power Distribution Networks

Real time topology knowledge is essential for situational awareness of power distribution networks. Line outages change the topology of a distribution network. Hence, outage detection is an important task. Most of the existing outage detection algorithms are centralized, in which sensors communicate their data to a control center which performs outage detection using the received data. However, with the increasing size of the distribution network and with different areas of the network being monitored by different operators, communication is a bottleneck and scalability is a major concern. To address these issues, we propose a novel outage detection algorithm using a divide and conquer approach. First, we divide a distribution network into sub-networks, such that outage detection can be run in parallel in each sub-network independently ensuring scalability to large networks. Further, to reduce the latency, bandwidth and attenuation challenges associated with communications in a large network, we divide each sub-network into multiple control areas which communicate only with their neighbors. We employ a distributed iterative load estimation across the control areas of each sub-network and then use the load estimate for local outage detection in each control area. Here, the performance of our algorithm is evaluated for multiple feeder models and compared against traditional centralized outage detection algorithms.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Virtual sensing of wind turbine hub loads and drivetrain fatigue damage, Virtuelle Sensoren für die Messung von Hauptwellenlasten und Ermüdungsschäden im Antriebstrang von Windenergieanlagen

Abstract: This paper presents a Digital Twin for virtual sensing of wind turbine aerodynamic hub loads, as well as monitoring the accumulated fatigue damage and remaining useful life in drivetrain bearings based on measurements of the Supervisory Control and Data Acquisition (SCADA) and the drivetrain condition monitoring system (CMS). The aerodynamic load estimation is realized with data-driven regression models, while the estimation of local bearing loads and damage is conducted with physics-based, analytical models. Field measurements of the DOE 1.5 research turbine are used for model training and validation. The results show low errors of 6.4% and 1.1% in the predicted damage at the main and the generator side high-speed bearing respectively. Zusammenfassung: In diesem Aufsatz wird ein digitaler Zwilling für Windenergieanlagen vorgestellt, welcher die virtuelle Erfassung der Hauptwellenlasten und die Zustandsüberwachung von Ermüdungschäden und der verbleibende Nutzungsdauer der Antriebsstranglager ermöglicht. Der digital Zwilling nutzt Messdaten des Supervisory Control and Data Acquisition (SCADA) Systems und des Zustandsüberwachungssystems des Antriebsstranges (CMS). Die Berechnung der Hauptwellenlasten ist mit datenbasierten Regressionsmodellen umgesetzt, während die Berechnung der Lagerkräfte und der Ermüdungsschaden mit physikbasierten Modelle durchgeführt wird. Für die Modellentwicklung und -validierung werden Feldmessdaten der DOE 1.5MW Turbine eingesetzt. Die Abweichungen in den Ermüdungsschäden am Hauptwellenlager und am Generatorwellenlager betragen lediglich 6,4% beziehungsweise 1,1%.

17 WIND ENERGY↗

State-of-the-art on research and applications of machine learning in the building life cycle

Fueled by big data, powerful and affordable computing resources, and advanced algorithms, machine learning has been explored and applied to buildings research for the past decades and has demonstrated its potential to enhance building performance. This study systematically surveyed how machine learning has been applied at different stages of building life cycle. By conducting a literature search on the Web of Knowledge platform, we found 9579 papers in this field and selected 153 papers for an in-depth review. The number of published papers is increasing year by year, with a focus on building design, operation, and control. However, no study was found using machine learning in building commissioning. There are successful pilot studies on fault detection and diagnosis of HVAC equipment and systems, load prediction, energy baseline estimate, load shape clustering, occupancy prediction, and learning occupant behaviors and energy use patterns. None of the existing studies were adopted broadly by the building industry, due to common challenges including (1) lack of large scale labeled data to train and validate the model, (2) lack of model transferability, which limits a model trained with one data-rich building to be used in another building with limited data, (3) lack of strong justification of costs and benefits of deploying machine learning, and (4) the performance might not be reliable and robust for the stated goals, as the method might work for some buildings but could not be generalized to others. Finally, findings from the study can inform future machine learning research to improve occupant comfort, energy efficiency, demand flexibility, and resilience of buildings, as well as to inspire young researchers in the field to explore multidisciplinary approaches that integrate building science, computing science, data science, and social science.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Situational awareness-enhancing community-level load mapping with opportunistic machine learning

Motivated by present and forthcoming challenges in the adoption and integration of distributed renewable energy, we develop a machine learning (ML) approach that builds short-fuse mappings connecting the occasionally-unobservable true load in one target community with information-rich signals collected from relatively more instrumented reference communities. Our setting is inspired by and tailored to target communities with significant unobservable behind-the-meter solar generation, where true load (a relatively well-behaved quantity of interest to grid operators) is hard to discern during daytime due to insufficient instrumentation and/or privacy reasons, but that can be related to reference communities with low unobservable distributed variable generation or with sufficient instrumentation. The developed mapping, herein realized with Support Vector Machine regression, is built using nighttime data from all communities, when their distributed generation is low or zero. Our ML algorithm opportunistically learns to correlate signals of interest and then is operationally used the next day to shed light into target community load evolution. The mapping is subsequently rebuilt, rolling its short-fuse scope perpetually forward in time. Here, we demonstrate the efficacy of our approach on nine synthetically generated topologies and associated timeseries stemming from real-world data, on which we observe cumulative error performance that yields lower than 10% and 15% daily-averaged mean absolute percentage errors in target community load estimation on more than about 75% and 90% of days, respectively, in multiple yearly evaluations that shed light on long-term performance also under seasonal and one-off effects. The proposed ML-powered methodology can offer grid operators much-improved visibility into a previously obscure space and can also serve as an additional source of information in broader, multi-modal solar disaggregation solutions.

14 SOLAR ENERGY↗

Multispectral impedance determination under dynamic load conditions

Impedance testing devices, circuits, systems, and related methods are disclosed. A Device Under Test (DUT) is excited with a multispectral excitation signal for an excitation time period while the DUT is under a load condition from a load operably coupled to the DUT. A response of the DUT is sampled over a sample time period. The sample time period is configured such that it includes an in-band interval during the excitation time period and one or more out-of-band intervals outside of the in-band interval. A response of the DUT to the load condition during the in-band interval is estimated by analyzing samples of the response from the one or more out-of-band intervals. Adjusted samples are computed by subtracting the estimated load response during the in-band interval from the samples from the in-band interval. An impedance of the DUT is estimated by analyzing the adjusted samples.

Christophersen, Jon P.↗

Multispectral impedance determination under dynamic load conditions

Impedance testing devices, circuits, systems, and related methods are disclosed. A method may include exciting a device coupled to a load, and capturing a response of the device. The method may further include adjusting the response based on an estimated load response of the device, and estimating an impedance of the device based on the adjusted response.

Christophersen, Jon P.↗

Sizing Considerations for EV Dynamic Wireless Charging Systems with Integrated Energy Storage

Roadways with dynamic wireless charging systems (DWCS) enable charge-sustaining in-motion EV charging, which can reduce charging idle time while increasing range capabilities. Spatially distributed transmitter coils are controlled in response to traffic load that varies significantly minute to minute with high power levels, very short charging time, and low system utilization like wind turbine power. Traffic load estimation and localized analysis may guide effective sizing and topology adoption for feasible and scalable DWCS deployment. DWCS traffic load approximation is reviewed with measured Automated Traffic Recorder (ATR) data and statistical distributions being used to create a synthetic load analyzed using proposed metrics quantifying system utilization over time. Lumped coil section segmentation is compared between second-based distance and spatial density analysis methods, offering 17-27% greater system utilization. A peak load shifting method is proposed for traffic redirection across two tracks with optional BESS integration increasing system utilization by 50-60% depending on time-based and power reserve-based sizing and control.

Lewis, Donovin D.↗