Search NASA⌕ Search

SEARCH · Search NASA

Results for “Local temperature determination”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Disturbances in the Arizona Monsoon

Numerical modeling simulations of tropical squall lines were begun to determine the role of large scale terrain features over Arizona and Mexico in their initiation and propagation. Installation was completed for a short-base, high resolution lightning location and detection network in and around Tucson. Data from a Doppler wind profiler is being analyzed to determine the role of large scale heating over the inter-mountain plateau region in governing local diurnal wind variations and possible relationships to the monsoon flow. The portable solar photometer for determining high temporal resolution values of the local precipitable water vapor was completed and calibrated. The assembly is nearly completed for a multi-channel microwave passive radiometer to determine local temperature and water vapor profiles.

Gall, Robert↗

10-kHz PLIF Thermometry for a Turbulent Jet Flame using Single Burst-mode OPO

Two-color Planar laser-induced fluorescence (TC-PLIF) thermometry techniques that employ two laser systems and two cameras face challenges when implemented in practical combustion facilities because of experimental complexity and multiple laser and camera requirements, particularly for high-speed TC-PLIF. To circumvent those problems, we developed a fast, dual-wavelength switching, burst-mode OPO technology to significantly reduce the experimental complexity of high-speed TC-PLIF thermometry and simplify its implementation in harsh combustion and flow test facilities. A fast, dual-wavelength switched seed laser enabled a high-energy, high-repetition-rate burst-mode laser to generate two 10-kHz pulse trains at wavelengths of ~354.8 nm. The injection-seeded OPO efficiently converts the burst-mode laser output to285.62 nm and 285.67 nm to excite the Q2(12) and P1(8) OH transitions. PLIF images were collected from each of the two excitation transitions with a single camera and an UV intensifier, and intensity ratios from the images were used to determine local temperatures. Ten kHz hydroxyl radical (OH) TC-PLIF for premixedCH4/Air/H2 jet flame was demonstrated.

thermometry↗

10-kHz PLIF Thermometry for Turbulent Jet Flame using Single Burst-mode OPO

Two-color Planar Laser-Induced Fluorescence (TC-PLIF) thermometry techniques that employ two laser systems and two cameras face challenges when implemented in practical combustion facilities because of experimental complexity and multiple laser and camera requirements, particularly for high-speed TC-PLIF. To circumvent those problems, we developed a fast, dual-wavelength switching, burst-mode OPO technology to significantly reduce the experimental complexity of high-speed TC-PLIF thermometry and simplify its implementation in harsh combustion and flow test facilities. A fast, dual-wavelength switched seed laser enabled a high-energy, high-repetition-rate burst-mode laser to generate two 10-kHz pulse trains at wavelengths of ~354.8 nm. The injection-seeded OPO efficiently converts the burst-mode laser output to 285.62 nm and 285.67 nm to excite the Q2(12) andP1(8) OH transitions. PLIF images were collected from each of the two excitation transitions with a single camera and an UV intensifier, and intensity ratios from the images were used to determine local temperatures. Ten kHz hydroxyl radical (OH) TC-PLIF for premixedCH4/Air/H2 jet flame was demonstrated.

thermometry↗

Radiometric calibration of Landsat Thematic Mapper Thermal Band

Radiometric calibration of satellite-acquired data is essential for quantitative scientific studies, as well as for a variety of image-processing applications. This paper describes a multiyear, on-orbit radiometric calibration of the Landsat Thematic Mapper (TM) Band 6 conducted at DOE's Pacific Northwest Laboratory. Numerous Landsat TM scenes acquired and analyzed included day and night coverages at several geographical locations over several seasons. Concurrent with Landsat overpasses, thermal field and local meteorological (surface and radiosonde) measurements were collected. At-satellite (uncorrected) radiances and temperatures for water and nonwater land cover were compared to ground truth (GT) measurements after making adjustments for atmospheric (using LOWTRAN), mixed-pixel, and emissivity effects. Results indicate that, for both water and nonwater features, TM Band 6 average corrected temperature determinations using local radiosonde data to adjust for atmospheric effects, and using appropriate emissivities, are within 1.0 C of GT temperature values. Temperatures of water pixels derived from uncorrected TM Band 6 data varied roughly between 1 and 3 C of ground truth values for water temperatures ranging between 4 and 24 C. Moreover, corrections using nonlocal and noncoincident radiosonde data resulted in errors as large as 12 C. Corrections using the U.S. Standard Atmosphere gave temperature values within 1 to 2 C of GT. The average uncertainty for field instruments was + or - 0.2 C; average uncertainty for Landsat TM corrected temperature determinations was + or - 0.4 C.

Wukelic, G. E.↗

Sensor for Monitoring Nanodevice-Fabrication Plasmas

The term plasma process diagnostics (PPD) refers to a spectroscopic technique and sensing hardware that have been proposed for monitoring plasma processes used to fabricate electronic devices that feature sizes as small as several nanometers. Nanometer dimensions are characteristic of the quantum level of miniaturization, where single impurity atoms or molecules can drastically change the local properties of the nanostructures. Such changes may be purposely used in nanoscale design but may also be extremely damaging or cause improper operation of the fabricated devices. Determination of temperature and densities of reactants near the developing features is important, since the structural synthesis is affected by characteristics of the local microenvironment. Consequently, sensors capable of nonintrusive monitoring with high sensitivity and high resolution are essential for real-time atomistic control of reaction kinetics and minimizing trace contamination in plasma processes used to fabricate electronic nanodevices. Such process-monitoring sensors are required to be compact, multiparametric, and immune to the harsh environments of processing plasmas. PPD is intended to satisfy these requirements. The specific technique used to implement plasma diagnostics with a PPD sensor would be an advanced version of continuous-wave cavity-ringdown spectroscopy (CW-CRDS) capable of profiling spectral line broadenings in order to derive both Doppler and Stark components. CRDS is based on measurements of the rate of absorption of laser light in an optical resonator. The ultimate sensitivity results from a very long absorption path length within the cavity and immunity to variations in incident laser intensity. The proposed version of this technique would involve the use of multiplexing tunable laser diodes and an actively modulated high-reflectivity optical resonator, thus offering a synergistic combination of simplicity, compactness, high sensitivity, and high resolution. The multiplexing capabilities of diode lasers could be utilized to make the PPD sensor a single, simple, compact, and inexpensive tool for the acquisition of multiparametric data. A PPD sensor would be capable of continuous measurement of such physical parameters as gas temperature, gas velocity, electron number density, and absolute densities of reacting chemical species. A laser beam can be easily adjusted to analyze the immediate vicinity of the growing nanostructures (or features etched down) in real time. The absorption enhancement in an optical cavity would afford the sensitivity needed for measurement of the temperature and densities of species at concentrations significantly lower than measurable by other nonintrusive techniques. It is anticipated that fully developed PPD sensors would enable simultaneous measurement of local temperature and determination of plasma species responsible for the synthesis and functionalization of nanodevices. These sensors would also enable tracking the pathways and origins of damaging contaminants, thereby providing feedback for adjustment of processes to optimize them and reduce contamination. The PPD sensors should also be useful for optimization of conventional microelectronics manufacturing plasma processes. Going beyond plasma processes for fabrication of electronic devices, PPD sensors could be used for monitoring of atoms, molecules, ions, radicals, clusters, and particles in a variety of other settings, including outer space. Because of their high sensitivity, such sensors could also prove useful for detecting traces of illegal drugs and explosives.

Bolshakov, Alexander↗

Development of a laser-induced heat flux technique for measurement of convective heat transfer coefficients in a supersonic flowfield

A technique is developed to measure the local convective heat transfer coefficient on a model surface in a supersonic flow field. The technique uses a laser to apply a discrete local heat flux at the model test surface, and an infrared camera system determines the local temperature distribution due to heating. From this temperature distribution and an analysis of the heating process, a local convective heat transfer coefficient is determined. The technique was used to measure the load surface convective heat transfer coefficient distribution on a flat plate at nominal Mach numbers of 2.5, 3.0, 3.5, and 4.0. The flat plate boundary layer initially was laminar and became transitional in the measurement region. The experimental results agreed reasonably well with theoretical predictions of convective heat transfer of flat plate laminar boundary layers. The results indicate that this non-intrusive optical measurement technique has the potential to obtain high quality surface convective heat transfer measurements in high speed flowfields.

Porro, A. Robert↗

A laser-induced heat flux technique for convective heat transfer measurements in high speed flows

A technique is developed to measure the local convective heat transfer coefficient on a model surface in a supersonic flow field. The technique uses a laser to apply a discrete local heat flux at the model test surface, and an infrared camera system determines the local temperature distribution due to the heating. From this temperature distribution and an analysis of the heating process, a local convective heat transfer coefficient is determined. The technique was used to measure the local surface convective heat transfer coefficient distribution on a flat plate at nominal Mach numbers of 2.5, 3.0, 3.5, and 4.0. The flat plate boundary layer initially was laminar and became transitional in the measurement region. The experimentally determined convective heat transfer coefficients were generally higher than the theoretical predictions for flat plate laminar boundary layers. However, the results indicate that this nonintrusive optical measurement technique has the potential to measure surface convective heat transfer coefficients in high speed flow fields.

Porro, A. R.↗

A laser-induced heat flux technique for convective heat transfer measurements in high speed flows

A technique is developed to measure the local convective heat transfer coefficient on a model surface in a supersonic flow field. The technique uses a laser to apply a discrete local heat flux at the model test surface, and an infrared camera system determines the local temperature distribution due to the heating. From this temperature distribution and an analysis of the heating process, a local convective heat transfer coefficient is determined. The technique was used to measure the local surface convective heat transfer coefficient distribution on a flat plate at nominal Mach numbers of 2.5, 3.0, 3.5, and 4.0. The flat plate boundary layer initially was laminar and became transitional in the measurement region. The experimentally determined convective heat transfer coefficients were generally higher than the theoretical predictions for flat plate laminar boundary layers. However, the results indicate that this nonintrusive optical measurement technique has the potential to measure surface convective heat transfer coefficients in high-speed flowfields.

Porro, A. R.↗

Dimensional analysis of acoustically propagated signals

Traditionally, long term measurements of atmospherically propagated sound signals have consisted of time series of multiminute averages. Only recently have continuous measurements with temporal resolution corresponding to turbulent time scales been available. With modern digital data acquisition systems we now have the capability to simultaneously record both acoustical and meteorological parameters with sufficient temporal resolution to allow us to examine in detail relationships between fluctuating sound and the meteorological variables, particularly wind and temperature, which locally determine the acoustic refractive index. The atmospheric acoustic propagation medium can be treated as a nonlinear dynamical system, a kind of signal processor whose innards depend on thermodynamic and turbulent processes in the atmosphere. The atmosphere is an inherently nonlinear dynamical system. In fact one simple model of atmospheric convection, the Lorenz system, may well be the most widely studied of all dynamical systems. In this paper we report some results of our having applied methods used to characterize nonlinear dynamical systems to study the characteristics of acoustical signals propagated through the atmosphere. For example, we investigate whether or not it is possible to parameterize signal fluctuations in terms of fractal dimensions. For time series one such parameter is the limit capacity dimension. Nicolis and Nicolis were among the first to use the kind of methods we have to study the properties of low dimension global attractors.

Hansen, Scott D.↗

Solar Thermal Vacuum Test of Deployable Astromesh Reflector

On September 10, 2008, a 36-hour Solar Thermal Vacuum Test of a 5m deployable mesh reflector was completed in JPL's 25' Space Simulator by the Advanced Deployable Structures Group at JPL. The testing was performed under NASA's Innovative Partnership Program (IPP) as a risk reduction effort for two JPL Decadal Survey Missions: DESDynI and SMAP. The 5.0 m aperture Astromesh reflector was provided by Northrop Grumman Aerospace Systems (NGAS) Astro Aerospace, our IPP industry partner. The testing utilized a state-of-the-art photogrammetry system to measure deformation of the reflector under LN2 cold soak, 0.25 Earth sun, 0.5 sun and 1.0 sun. An intricate network of thermocouples (approximately 200 in total) was used to determine the localized temperature across the mesh as well as on the perimeter truss of the reflector. Half of the reflector was in a fixed shadow to maximize thermal gradients. A mobility system was built for remotely actuating the cryo-vacuum capable photogrammetry camera around the circumference of the Solar Simulator. Photogrammetric resolution of 0.025 mm RMS (0.001") was achieved over the entire 5 meter aperture for each test case. The data will be used for thermo-elastic model correlation and validation, which will benefit the planned Earth Science Missions.

Photogrammetry↗

An improved algorithm for the modeling of vapor flow in heat pipes

A heat pipe vapor flow algorithm suitable for use in codes on microcomputers is presented. The incompressible heat pipe vapor flow studies of Busse are extended to incorporate compressibility effects. The Busse velocity profile factor is treated as a function of temperature and pressure. The assumption of a uniform saturated vapor temperature determined by the local pressure at each cross section of the pipe is not made. Instead, a mean vapor temperature, defined by an energy integral, is determined in the course of the solution in addition to the pressure, saturation temperature at the wall, and the Busse velocity profile factor. For alkali metal working fluids, local species equilibrium is assumed. Temperature and pressure profiles are presented for several cases involving sodium heat pipes. An example for a heat pipe with an adiabatic section and two evaporators in sequence illustrates the ability to handle axially varying heat input. A sonic limit plot for a short evaporator falls between curves for the Busse and Levy inviscid sonic limits.

Tower, Leonard K.↗

Analytical determination of local surface heat-transfer coefficients for cooled turbine blades from measured metal temperatures

Analytical methods are presented for the determination of local values of outside and inside heat-transfer coefficients and effective gas temperatures by use of turbine-blade-temperature measurements. The methods are derived for a number of configurations that can be applied to typical cooled-turbine-blade shapes as well as to other types of heat-transfer apparatus.

TURBINE COOLING↗

Design and Testing of an Automated System using Thermochromatic Liquid Crystals to Determine Local Heat Transfer Coefficients for an Impinging Jet

Using thermochromatic liquid crystal to measure surface temperature, an automated transient method with time-varying free-stream temperature is developed to determine local heat transfer coefficients. By allowing the free-stream temperature to vary with time, the need for complicated mechanical components to achieve a step temperature change is eliminated, and by using the thermochromatic liquid crystals as temperature indicators, the labor intensive task of installing many thermocouples is omitted. Bias associated with human perception of the transition of the thermochromatic liquid crystal is eliminated by using a high speed digital camera and a computer. The method is validated by comparisons with results obtained by the steady-state method for a circular Jet impinging on a flat plate. Several factors affecting the accuracy of the method are evaluated.

Tan, Benjamin↗

Pressure and velocity in a developing coaxial jet

Determinations of static pressure, mean velocity and turbulence intensity in the developing region of coaxial jets are presented. Detailed profiles were obtained at twelve axial locations (extending from the nozzle exit for a distance of 5 diameters) downstream from a single element of the Bell Aerospace H2/O2 19-element coaxial injector. Measurements of mass-flux per unit area (using a constant temperature anemometer), total pressure and local temperature were used in the determination of local static pressure and velocity. These data show a low pressure region exists near the nozzle exit. Although this pressure reduction is small (0.34 psi), it substantially altered the flow development. Comparison of results shows that velocity near the nozzle exit decreases initially (no central velocity core) as a result of both pressure gradients and viscous mixing. These data are compared with analytical predictions made using available computer codes. Results show the need to consider pressure effects in any proposed mathematical model.

Moon, L. F.↗

High-energy astrophysics: A theoretical analysis of thermal radiation from neutron stars

The unambiguous detection of thermal radiation from the surface of a cooling neutron star was one of the most anxiously awaited results in neutron star physics. This particular Holy Grail was found by Halpern and Holt, who used ROSAT to detect pulsed X-rays from the gamma-ray source Geminga and demonstrate that it was a neutron star, probably a radio pulsar beamed away from us. At an age of approximately 3.4 x 10(exp 5) years, Geminga is in the photon cooling era. Its surface temperature of 5.2 x 10(exp 5) K can be explained within the contexts of both the slow and fast cooling scenarios. In the slow cooling scenario, the surface temperature is too high unless the specific heat of the interior is reduced by extensive baryon pairing. In the fast cooling scenario, the surface temperature will be much too low unless the fast neutrino cooling is shut off by baryon pairing. Two other pulsars, PSR 0656+14 and PSR 1055-52, have also been detected in thermal X-rays by ROSAT. They are also in the photon cooling era. All of this research's neutron star cooling models to date have used the unmagnetized effective temperature-interior temperature relation for the outer boundary condition. Models are being improved by using published magnetic envelope calculations and assumed geometried for the surface magnetic field to determine local interior temperature-emitted flux relations for the surface of the star.

Applegate, James H.↗

Thin-Filament Pyrometry Developed for Measuring Temperatures in Flames

Many valuable advances in combustion science have come from observations of microgravity flames. This research is contributing to the improved efficiency and reduced emissions of practical combustors and is benefiting terrestrial and spacecraft fire safety. Unfortunately, difficulties associated with microgravity have prevented many types of measurements in microgravity flames. In particular, temperature measurements in flames are extremely important but have been limited in microgravity. A novel method of measuring temperatures in microgravity flames is being developed in-house at the National Center for Microgravity Research and the NASA Glenn Research Center and is described here. Called thin-filament pyrometry, it involves using a camera to determine the local gas temperature from the intensity of inserted fibers glowing in a flame. It is demonstrated here to provide accurate measurements of gas temperatures in a flame simultaneously at many locations. The experiment is shown. The flame is a laminar gas jet diffusion flame fueled by methane (CH4) flowing from a 14-mm round burner at a pressure of 1 atm. A coflowing stream of air is used to prevent flame flicker. Nine glowing fibers are visible. These fibers are made of silicon carbide (SiC) and have a diameter of 15 m (for comparison, the average human hair is 75 m in diameter). Because the fibers are so thin, they do little to disturb the flame and their temperature remains close to that of the local gas. The flame and glowing filaments were imaged with a digital black-and-white video camera. This camera has an imaging area of 1000 by 1000 pixels and a wide dynamic range of 12 bits. The resolution of the camera and optics was 0.1 mm. Optical filters were placed in front of the camera to limit incoming light to 750, 850, 950, and 1050 nm. Temperatures were measured in the same flame in the absence of fibers using 50-m Btype thermocouples. These thermocouples provide very accurate temperatures, but they generally are not useful in microgravity tests because they measure temperature at only one location at a time. Thermocouple measurements at a height of 11 mm above the burner were used to calibrate the thin-filament pyrometry system at all four wavelengths. This calibration was used to perform thin-filament pyrometry at other heights above the burner. One such profile is shown in this graph; this is for a height of 21 mm. The agreement between the pyrometry measurements and thermocouple results at this height is excellent in the range of 1000 to 2000 K, with an estimated uncertainty of 50 K and an estimated upper limit of 2500 K. Neither the thermocouple nor the thin-filament pyrometry temperatures have been corrected for radiation, but the correction is expected to be nearly the same for both methods. We anticipate that thin-filament pyrometry similar to that developed here will become an important diagnostic for studies of microgravity flames owing to its accuracy and its ability to simultaneously measure finely spaced temperatures.

Sunderland, Peter B.↗

Method for determination of neutral atomic oxygen flux

A method for measuring atomic oxygen flux to a probe surface is presented which uses two probes. One is a glass probe enclosing a small ceramic resistor heater and a thermocouple for determining the ambient local temperature. Another probe has a silver tip and a thermocouple inside it. In an atomic oxygen environment, the silver probe will quickly develop a silver oxide coating which provides for atomic oxygen recombination. The use of the two probes allows a more accurate determination of the energy input into the catalytic silver oxide probe due to recombination.

Carruth, M. R., Jr.↗