Search NASA⌕ Search

SEARCH · Search NASA

Results for “Location”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Locating rocket triggered lightning using the LLP lightning locating system at the NASA Kennedy Space Center

Five rocket-triggered cloud-to-ground lightning flashes were detected by the operational lightning-locating system at the NASA Kennedy Space Center on August 17, 1984. The locating system, which was designed to detect natural lightning, detected at least 2 and as many as 6 strokes in the triggered flashes, suggesting that some of the strokes in the triggered lightning had signal-amplitude and waveshape characteristics similar to natural lightning. However, not all triggered strokes were detected, indicating that some strokes were atypical in nature. Since the ground-strike points of the triggered flashes were known quite precisely, the accuracy of the lightning-locating system was also evaluated. The three direction finders were found to have a mean bearing accuracy of + or - 0.5-0.6 deg. The distance errors of the real-time position solutions of the locating system on the triggered flashes were in the range of 195-770 m, with a mean of 480 m.

Maier, M. W.↗

Interim Measure Report South Water Pump Station Potential Release Location 213 – Location of Concern 2 Kennedy Space Center, Florida

This report presents a summary of the polychlorinated biphenyl (PCB) interim measure (IM) activities that occurred in December 2022 and March 2023 at Location of Concern (LOC) 2 – Electrical Equipment Area associated with the South Water Pump Station (SWPS) Potential Release Location (PRL) 213, located at the John F. Kennedy Space Center (KSC), Florida. The SWPS site is monitored under KSC’s Resource Conservation and Recovery Act Corrective Action Program, which also meets the requirements of Chapter 62-780, Florida Administrative Code. Assessment activities have previously been performed at six SWPS LOCs identified during a Solid Waste Management Unit assessment in 2013. Based on the data collected during these assessments, it was determined that IM activities would be completed at one of the LOCs, LOC 2 – Electrical Equipment Area, and an IM Work Plan was prepared and approved. In 2019, demolition of the SWPS buildings and structures was completed, allowing for additional assessment at LOC 2, and it was determined that soil excavation to remove PCB-impacted soils was no longer required for LOC 2. The IM activities conducted following demolition are presented in this report and include shallow soil sample collection, conducted in December 2022, and monitoring well installation and groundwater sampling, both conducted in March 2023. AECOM Technical Services, Inc. (AECOM) personnel collected two soil samples from two boring locations, SWPS-SB0005 and SWPS-SB0018. The samples were collected at 0 to 0.5 feet below land surface (bls). AECOM also conducted oversight of one monitoring well installation, SWPS-MW0001 screened from 4 to 14 feet bls, and then subsequently collected one groundwater sample from SWPS-MW0001. The samples were submitted to a fixed-based laboratory for analysis by United States Environmental Protection Agency Method 8082A for total PCBs. There were no detections of PCBs in soil or groundwater during the reporting period.

Chadwick Sloan Lee↗

Location and acquisition of objects in unpredictable locations

A teleoperator system with a computer for manipulator control to combine the capabilities of both man and computer to accomplish a task is described. This system allows objects in unpredictable locations to be successfully located and acquired. By using a method of characterizing the work-space together with man's ability to plan a strategy and coarsely locate an object, the computer is provided with enough information to complete the tedious part of the task. In addition, the use of voice control is shown to be a useful component of the man/machine interface.

Sword, A. J.↗

LDAR observations of a developing thunderstorm correlated with field mill, ground strike location, and weather radar data including the first report of the design and capabilities of a new, time-of-arrival Ground-strike Location System (GSLS)

An experiment designed to observe and measure a thunderstorm prior to, during, and after its development over the Kennedy Space Center was successful. Correlated measurements of airborne field strength, ground-based field strength, LDAR lightning discharge location in the clouds, weather radar percipitation echoes, plus ground strike location with the new KSC Ground Strike Location System (GSLS) were gathered, and reported. This test marks the first operational use of the GSLS System, and this report contains the first report of its design and capabilities.

Poehler, H. A.↗

Antarctic Meteorite Location and Mapping Project (AMLAMP): Antarctic meteorite location map series explanatory text and user's guide to AMLAMP data

This technical report is an update to LPI Technical Report 89-02, which contained data and information that was current to May 1987. Since that time approximately 4000 new meteorites have been collected, mapped, and characterized, mainly from the numerous ice fields in the Allan Hills-David Glacier region, from the Pecora Escarpment and Moulton Escarpment in the Thiel Mountains-Patuxent region, the Wisconsin Range region, and from the Beardmore region. Meteorite location maps for ice fields from these regions have been produced and are available. This report includes explanatory texts for the maps of new areas and provides information on updates of maps of the areas covered in LPI Technical Report 89-02. Sketch maps and description of locales that have been searched and have yielded single or few meteorites are also included. The meteorite listings for all the ice fields have been updated to include any classification changes and new meteorites recovered from ice fields in the Allan Hills-David Glacier region since 1987. The text has been reorganized and minor errors in the original report have been corrected. Computing capabilities have improved immensely since the early days of this project. Current software and hardware allow easy access to data over computer networks. With various commercial software packages, the data can be used many different ways, including database creation, statistics, and mapping. The databases, explanatory texts, and the plotter files used to produce the meteorite location maps are available through a computer network. Information on how to access AMLAMP data, its formats, and ways it can be used are given in the User's Guide to AMLAMP Data section. Meteorite location maps and thematic maps may be ordered from the Lunar and Planetary Institute. Ordering information is given in Appendix A.

Schutt, J.↗

Location, location: deciphering the significance of in-situ hydrogen analyses of Martian meteorite phases

Understanding how inner planets acquired their volatiles such as hydrogen (H) is fundamental to constrain models of solar system formation [e.g. 1]. One avenue of estimating the H content and isotopic characteristics of differentiated planets is to analyze the samples we have from them as meteorites. Ideally, the H content and isotopic characteristic of the mantle sources of these igneous rocks should give insight into the volatile origin of each planetary body. The mantle H signatures can be estimated from that of the parent melt, which in turn may be derived from that of the first crystallized phases. However, we will illustrate the processes that can modify the H content and D/H ratios of pyroxene, olivine and feldspar in selected Martian meteorites relative to those of their mantle sources, with two key protocols for SIMS analysis. The first key is to put each analysis in textural context ("location, location"). In particular, of prime importance is whether an analysis is done at the center or the edge of a mineral grain, close or far from a shock disturbed area, and in a mineral crystallized at the beginning or late in the differentiation sequence. Accompanying the H analyses done by SIMS with major and trace element data at the same analysis locations allows to constrain the history of crystallization, cooling, alteration and shock of the meteorite. For example, volcanic degassing can be evidenced by decreasing water contents and increasing D/H ratios from core to edge of nakhlite pyroxenes [2]. Traverses of H analyses in pyroxene and maskelynite in shergottite LAR 06319 provide examples of H contents and D/H ratios modified during degassing following shock [3]. The second key is to assess if the area analyzed by SIMS has shock generated damage of the mineral structure, as will be shown in pyroxene and olivine from shergottite RBT 04262. Olivine in shergottites have too high water contents to be explained with an igneous origin and their D/H ratios are more consistent with terrestrial alteration, as observed before [4]. A review of all these processes shows how careful one has to be prior to using H measurements in meteorites to infer the origin and amount of water in differentiated planetary interiors.

A.H. Peslier↗

The Structure and Evolution of LOCBURST: The BATSE Burst Location Algorithm

The gamma-ray burst (GRB) location algorithm used to produce the BATSE GRB locations is described. The general flow of control of the current location algorithm is presented, and the significant properties of the various physical inputs required are identified. The development of the burst location algorithm during the releases of the BATSE IB, 2B, and 3B GRB catalogs is presented so that the reasons for the differences in the positions and error estimates between the catalogs can be understood. In particular, differences between the 2B and 3B locations are discussed for events that have moved significantly and the reasons for the changes explained. The locations of bursts located independently by the interplanetary network (IPN) are used to illustrate the effect on burst location accuracy of various components of the algorithm. IPN data and locations from other gamma-ray instruments are used to calculate estimates of the systematic errors on BATSE burst locations.

Pendleton, Geoffrey N.↗

The Structure of Evolution LOCBURST: The BATSE Burst Location Algorithm

The gamma-ray bursts (GRB) location algorithm used to produce the BATSE GRB locations is described. The general flow of control of the current location algorithm is presented and the significant properties of the various physical inputs required are identified. The development of the burst location algorithm during the releases of the BATSE 1B, 2B, and 3B gamma-ray burst catalogs is presented so that the reasons for the differences in the positions and error estimates between the catalogs can be understood. In particular, differences between the 2B and 3B locations are discussed for events that have moved significantly and the reasons for the changes explained. The locations of bursts located independently by the interplanetary network are used to illustrate the effect on burst location accuracy of various components of the algorithm. IPN data as well as locations from other gamma-ray instruments are used to calculate estimates of the systematic errors on BATSE burst locations.

Pendleton, Geoffrey N.↗

The Effect of Mission Location on Mission Costs and Equivalent System Mass

Equivalent System Mass (ESM) is used by the Advanced Life Support (ALS) community to quantify mission costs of technologies for space applications (Drysdale et al, 1999, Levri et al, 2000). Mass is used as a cost measure because the mass of an object determines propulsion (acceleration) cost (i.e. amount of fuel needed), and costs relating to propulsion dominate mission cost. Mission location drives mission cost because acceleration is typically required to initiate and complete a change in location. Total mission costs may be reduced by minimizing the mass of materials that must be propelled to each distinct location. In order to minimize fuel requirements for missions beyond low-Earth orbit (LEO), the hardware and astronauts may not all go to the same location. For example, on a Lunar or Mars mission, some of the hardware or astronauts may stay in orbit while the rest of the hardware and astronauts descend to the planetary surface. In addition, there may be disposal of waste or used hardware at various mission locations to avoid propulsion of mass that is no longer needed in the mission. This paper demonstrates how using location factors in the calculation of ESM can account for the effects of various acceleration events and can improve the accuracy and value of the ESM metric to mission planners. Even a mission with one location can benefit from location factor analysis if the alternative technologies under consideration consume resources at different rates. For example, a mission that regenerates resources will have a relatively constant mass compared to one that uses consumables and vents/discards mass along the way. This paper shows examples of how location factors can affect ESM calculations and how the inclusion of location factors can change the relative value of technologies being considered for development.

Fisher, John W.↗

A Dynamic Failure Model for Predicting the Impact that a Program Location has on the Program

This paper presents a dynamic technique for predicting the effect that a "location" of a program will have on the program's computational behavior. The technique is based on the three necessary and sufficient conditions for software failure to occur: (1) a fault must be executed, (2) the fault must adversely affect the data state, and (3) the adverse effect in a data state must affect program output. In order to predict the effect that a location of a program will have on the program's computational behavior, the following characteristics of each program location are estimated: (1) the probability that a location of the program is executed, (2) the probability that a location of the program noticeably affects the program state created by the location, and (3) the probability that the data states created by a location affect the program's output. With estimates of these characteristics for each location in a program, we can predict those locations where a fault can more easily remain undetected during testing, as well as predict the degree of testing necessary to be convinced that a fault is not remaining undetected in a particular location.

Voas, Jeffrey↗

Confirmation of NLDN Long Range Strike Locations with LIS Observations

This study compares the lightning locations reported by the National Lightning Detection Network (NLDN) with the lightning locations determined by the Lightning Imaging Sensor (LIS). The NLDN system identifies the rf signature of cloud-to-ground lightning. The LIS data is the top level of a hierarchy of optical data objects. The centroid and timing of each LIS lightning activity center are compared with each flash in a subset of the NLDN long range lightning location data in a portion of the Atlantic Ocean and the Caribbean Sea consisting of those locations more than 625 km from any sensor. This subset is produced by analyzing each reported NLDN location to determine if that location is within the LIS field of view at the time of the reported flash. The Tropical Rainfall Measuring Mission Satellite (TRMM) orbit limits the cross-sensor comparison to tropical and sub-tropical regions. Because the rf-detection system depends on ionospheric propagation conditions, a separate analysis was made for daylight conditions at both source and sensor as well as nighttime at both places. A full year of data is compared to provide an adequate sample of each data set. Confirmation of lightning in the general location of the NLDN report is established when LIS detected one or more centers of lightning activity within a 2 degree radius from the NLDN location.

Boeck, William↗

Preliminary Design of a Lightning Optical Camera and ThundEr (LOCATE) Sensor

The preliminary design of an optical/acoustical instrument is described for making highly accurate real-time determinations of the location of cloud-to-ground (CG) lightning. The instrument, named the Lightning Optical Camera And ThundEr (LOCATE) sensor, will also image the clear and cloud-obscured lightning channel produced from CGs and cloud flashes, and will record the transient optical waveforms produced from these discharges. The LOCATE sensor will consist of a full (360 degrees) field-of-view optical camera for obtaining CG channel image and azimuth, a sensitive thunder microphone for obtaining CG range, and a fast photodiode system for time-resolving the lightning optical waveform. The optical waveform data will be used to discriminate CGs from cloud flashes. Together, the optical azimuth and thunder range is used to locate CGs and it is anticipated that a network of LOCATE sensors would determine CG source location to well within 100 meters. All of this would be accomplished for a relatively inexpensive cost compared to present RF lightning location technologies, but of course the range detection is limited and will be quantified in the future. The LOCATE sensor technology would have practical applications for electric power utility companies, government (e.g. NASA Kennedy Space Center lightning safety and warning), golf resort lightning safety, telecommunications, and other industries.

Phanord, Dieudonne D.↗

Adjustment of Sensor Locations During Thermal Property Parameter Estimation

The temperature dependent thermal properties of a material may be evaluated from transient temperature histories using nonlinear parameter estimation techniques. The usual approach is to minimize the sum of the squared errors between measured and calculated temperatures at specific locations in the body. Temperature measurements are usually made with thermocouples and it is customary to take thermocouple locations as known and fixed during parameter estimation computations. In fact, thermocouple locations are never known exactly. Location errors on the order of the thermocouple wire diameter are intrinsic to most common instrumentation procedures (e.g., inserting a thermocouple into a drilled hole) and additional errors can be expected for delicate materials, difficult installations, large thermocouple beads, etc.. Thermocouple location errors are especially significant when estimating thermal properties of low diffusively materials which can sustain large temperature gradients during testing. In the present work, a parameter estimation formulation is presented which allows for the direct inclusion of thermocouple positions into the primary parameter estimation procedure. It is straightforward to set bounds on thermocouple locations which exclude non-physical locations and are consistent with installation tolerances. Furthermore, bounds may be tightened to an extent consistent with any independent verification of thermocouple location, such as x-raying, and so the procedure is entirely consonant with experimental information. A mathematical outline of the procedure is given and its implementation is illustrated through numerical examples characteristic of light-weight, high-temperature ceramic insulation during transient heating. The efficacy and the errors associated with the procedure are discussed.

Milos, Frank S.↗

Close binding of identity and location in visual feature perception

The binding of identity and location information in disjunctive feature search was studied. Ss searched a heterogeneous display for a color or a form target, and reported both target identity and location. To avoid better than chance guessing of target identity (by choosing the target less likely to have been seen), the difficulty of the two targets was equalized adaptively; a mathematical model was used to quantify residual effects. A spatial layout was used that minimized postperceptual errors in reporting location. Results showed strong binding of identity and location perception. After correction for guessing, no perception of identity without location was found. A weak trend was found for accurate perception of target location without identity. We propose that activated features generate attention-calling "interrupt" signals, specifying only location; attention then retrieves the properties at that location.

Orientation↗