Search NASA⌕ Search

SEARCH · Search NASA

Results for “Long lifetime”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Long-Lifetime Laser Materials For Effective Diode Pumping

Long quantum lifetimes reduce number of diodes required to pump. Pumping by laser diodes demonstrated with such common Nd laser materials as neodymium:yttrium aluminum garnet (Nd:YAG) and Nd:YLiF4, but such materials as Nd:LaF3, Nd:NaF.9YF3, and possibly Nd:YF3 more useful because of long lifetimes of their upper laser energy levels. Cost effectiveness primary advantage of solid-state laser materials having longer upper-laser-level lifetimes. Because cost of diodes outweighs cost of laser material by perhaps two orders of magnitude, cost reduced significantly.

Barnes, Norman P.↗

Averaged initial Cartesian coordinates for long lifetime satellite studies

A set of initial Cartesian coordinates, which are free of ambiguities and resonance singularities, is developed to study satellite mission requirements and dispersions over long lifetimes. The method outlined herein possesses two distinct advantages over most other averaging procedures. First, the averaging is carried out numerically using Gaussian quadratures, thus avoiding tedious expansions and the resulting resonances for critical inclinations, etc. Secondly, by using the initial rectangular Cartesian coordinates, conventional, existing acceleration perturbation routines can be absorbed into the program without further modifications, thus making the method easily adaptable to the addition of new perturbation effects. The averaged nonlinear differential equations are integrated by means of a Runge Kutta method. A typical step size of several orbits permits rapid integration of long lifetime orbits in a short computing time.

Pines, S.↗

High-Performing, Low-Temperature-Operating, Long-Lifetime Aerospace Lubricants

Long-duration space exploration will require spacecraft systems that can operate effectively over several years with minimal or no maintenance. Aerospace lubricants are key components of spacecraft systems. Physical Sciences Inc., has synthesized and characterized novel ionic liquids for use in aerospace lubricants that contribute to decreased viscosity, friction, and wear in aerospace systems. The resulting formulations offer low vapor pressure and outgassing properties and thermal stability up to 250 C. They are effective for use at temperatures as low as -70 C and provide long-term operational stability in aerospace systems. In Phase II, the company scaled several new ionic liquids and evaluated a novel formulation in a NASA testbed. The resulting lubricant compounds will offer lower volatility, decreased corrosion, and better tribological characteristics than standard liquid lubricants, particularly at lower temperatures.

Joshi, Prakash↗

Development of Long-Lifetime Pulsed Gas Valves for Pulsed Electric Thrusters

The design and test results for two types of pulsed gas valves are presented. The valves, a piezo valve and a solenoid actuated valve, must have exceedingly long lifetime to support gas-fed pulsed electric thruster operation for missions of interest. The performance of both valves was tested, with both demonstrating the capability to throttle the gas flow rate while maintaining low leakage levels below 10(exp -3) sccs of He at the beginning of valve lifetime. The piezo valve varies the flow rate by changing the amount that the valve is open, which is a function of applied voltage. This valve demonstrated continuous throttlability from 0-10 mL/s, with opening and closing times of 100 microsecond or less. The solenoid actuated valve flow rate changes as a function of the inlet gas pressure, with demonstrated flow rates in these tests from 2.7-11 mL per second. The valve response time is slower than the piezo valve, opening in 1-2 ms and closing in several ms. The solenoid actuated valve was tested to one million cycles, with the valve performance remaining relatively unchanged throughout the test. Galling of the sliding plunger caused the valve to bind and fail just after one million cycles, but at this point in the test the valve sealing surface leak rate still appeared to be well below the maximum target leak rake of 1×10(exp -3) sccs of He.

Burkhardt, Wendel M.↗

Development of Long-Lifetime Pulsed Gas Valves for Pulsed Electric Thrusters

It is advantageous for gas-fed pulsed electric thrusters to employ pulsed valves so propellant is only flowing to the device during operation. The propellant utilization of the thruster will be maximized when all the gas injected into the thruster is acted upon by the fields produced by the electrical pulse. Gas that is injected too early will diffuse away from the thruster before the electrical pulse can act to accelerate the propellant. Gas that is injected too late will miss being accelerated by the already-completed electrical pulse. As a consequence, the valve must open quickly and close equally quickly, only remaining open for a short duration. In addition, the valve must have only a small amount of volume between the sealing body and the thruster so the front and back ends of the pulse are as coincident as possible with the valve cycling, with very little latent propellant remaining in the feed lines after the valve is closed. For a real mission of interest, a pulsed thruster can be expected to pulse at least 10(exp 10) - 10(exp 11) times, setting the range for the number of times a valve must open and close. The valves described in this paper have been fabricated and tested for operation in an inductive pulsed plasma thruster (IPPT) for in-space propulsion. In general, an IPPT is an electrodeless space propulsion device where a capacitor is charged to an initial voltage and then discharged, producing a high-current pulse through a coil. The field produced by this pulse ionizes propellant, inductively driving current in a plasma located near the face of the coil. Once the plasma is formed, it can be accelerated and expelled at a high exhaust velocity by the electromagnetic Lorentz body force arising from the interaction of the induced plasma current and the magnetic field produced by the current in the coil. The valve characteristics needed for the IPPT application require a fast-acting valve capable of a minimum of 10(exp 10) valve actuation cycles. Since even 10(exp 9) cycles is well above anything demonstrated, this lower value was selected as the design point for the present work. The valve seal must remain leak-tight throughout operation, and the body must maintain a low internal leakage at relatively high operating temperatures. The full set of design requirements used for this program are summarized in Table 1. In this work, we describe two pulsed gas valves that have been fabricated to have long lifetime and demonstrate the characteristics listed above. The first is a miniaturized, conventional electromagnet-based valve while the second is a piezoelectric-based valve design. The conventional valve, shown in Fig. 1, is opened by use of a solenoid electromagnetic actuator. When current is applied to the solenoid coil, magnetic forces pull the plunger away from the valve seat, allowing fluid to flow through the valve. Removal of electrical current permits the spring and fluid pressure to seat the plunger, halting the flow of fluid. The valve body is fabricated from 304L corrosion resistant steel (CRES) and while the parts that form the magnetic circuit are fabricated from 430 CRES. This material does not have optimum magnetic properties, but its corrosion resistance permits incorporation into a design without requiring an additional plating process. A viton O-ring compound (Parker V0884-75), selected for its mechanical strength at elevated temperatures, was used for the valve seat seal. The design was based solely on the use of analytical sizing calculations, as opposed to a more rigorous finite element analysis. While this valve is small and relatively lightweight, it does not represent a design that is optimized for mass and/or a given volume envelope. The piezoelectric valve is a "puller" valve design. Applying a voltage to the piezo crystal causes it to elongate and pull a pintle off the seat, opening the valve. The valve seal consists of the pintle with an external, spherically-formed tip fabricated from Inconel 625 and the seat fabricated from Inconel 718 and possessing a spherical surface that permits the pintle to align with the valve body centerline after each cycle, maintaining the circumferential metal-on-metal seal. The contact stress on the valve pintle is expected in the worst case to be 96.5 MPa (14 ksi), which is well below the work hardening value of 413.7 MPa (60 ksi) for Inconel 615. Results presented in this work will compare the performance of each valve, both to each other and to the valve design requirements given in Table 1. In general, both valves meet all the performance envelope requirements, but the piezoelectric valve consumes considerably less power and has a faster response time over the conventional solenoid-driven valves.

Burkhardt, Wendel M.↗

Space-and Ground-Based Non-Accelerated Long Lifetime Data for Ruggedized Commercial Non-Planar Ring Oscillator (NPRO) Lasers

Lifetime data is presented for ruggedized commercial NPRO lasers used in the Tropospheric Emission Spectrometer (TES) Instrument on NASA’s Aura Earth-orbiting spacecraft, including 20 years of data from two life test units on the ground, 12 years of on-orbit data from TES Laser A, and 2 years of on-orbit data from TES Laser B. The TES lasers are diode-pumped Non-Planar Ring Oscillator (NPRO) lasers using Nd:YAG crystals. Since accelerated life testing was not possible on the complete laser, early prototype lasers that had gone through thermal cycling and vibration testing were placed on non-accelerated life tests with the hope of gathering at least a couple of years of data before launch. Long-term lifetime data for hybrid laser systems in space applications is not abundant, and out of necessity, accelerated reliability testing is usually done over a relatively short time with a large number of devices. The data presented in this paper is unique as it tracks the optical power output over time of a total of four lasers on the order of decades rather than months or years. Two of the lasers have each been on life test for over 20 years on the ground and are still operating, and the other two lasers have been on-orbit for 14 years. TES Laser A was still operating when the TES Instrument was decommissioned in January 2018. Therefore, the data presented covers over 450,000 non-accelerated device-hours, with 23% of those hours being in space.

Kane, T.J.↗

Long lifetime hollow cathodes for 30-cm mercury ion thrusters

An experimental investigation of hollow cathodes for 30-cm Hg bombardment thrusters was carried out. Both main and neutralizer cathode configurations were tested with both rolled foil inserts coated with low work function material and impregnated porous tungsten inserts. Temperature measurements of an impregnated insert at various positions in the cathode were made. These, along with the cathode thermal profile are presented. A theory for rolled foil and impregnated insert operation and lifetime in hollow cathodes is developed. Several endurance tests, as long as 18000 hours at emission currents of up to 12 amps were attained with no degradation in performance.

Mirtich, M. J.↗

Long lifetime hollow cathodes for 30-cm mercury ion thrusters

An experimental investigation of hollow cathodes for 30-cm Hg bombardment thrusters was carried out. Both main and neutralizer cathode configurations were tested with both rolled foil inserts coated with low work function material and impregnated porous tungsten inserts. Temperature measurements of an impregnated insert at various positions in the cathode were made. These, along with the cathode thermal profile are presented. A theory for rolled foil and impregnated insert operation and lifetime in hollow cathodes is developed. Several endurance tests, as long as 18,000 hours at emission currents of up to 12 amps were attained with no degradation in performance.

Mirtich, M. J.↗

Electronically controlled motor drive system has ultra-high reliability and long lifetime

Direct drive electromechanical system is composed of brushless dc torque motor, offset-tooth magnetic sensor that derives position and rate information directly from output shaft, and rotary power transformer that transfers electrical power from external source to proper load. System has high servo loop stiffness and minimum power consumption.

Veillette, L. J.↗

Feasibility study for long lifetime helium dewar

A feasible concept for a launchable three year lifetime helium dewar was investigted. Current helium dewar designs were examined to see where the largest potential reductions in parasitic heat loads can be made. The study was also devoted to examining support concepts. The support concept chosen, a passive orbital disconnect strut (PODS), has an orbital support conductance that is lower by more than an order of magnitude over current tension band supports. This lower support conductance cuts the total dewar weight in half for the same three year life time requirements. Effort was also concentrated on efficient wire feed through designs and vapor cooling of the multilayer insulation, supports, wire feed throughs and plumbing penetrations. A single stage helium dewar vs. dual stage dewars with a guard cryogen of nitrogen or neon was examined. The single stage dewar concept was selected. Different support concepts were analyzed from which the PODS support concepts was chosen. A preliminary design of the dewar was thermally and structurally analyzed and laid out including system weights, thermal performance and performance sensitivities.

Parmley, R. T.↗

Do quasars have cosmologically long lifetimes

An alternative explanation to gravitational lensing is examined, by which problems inherent in space density evolution are avoided without invoking gravitational effects. Apparent and unreal density evolution follows as an immediate consequence, if the quasar lifetimes that are the only free parameter in the model proposed are of the order of three billion years. If such lifetimes are the case, while quasars may occur less frequently than has been thought, the local density of quasars may have been grossly underestimated.

Chanan, G. A.↗

Long-lifetime Martian orbit selection using a time-dependent model of the Martian atmosphere

A mathematical model of the time-dependent Martian atmosphere has been developed in order to accurately calculate the effects of aerodynamic drag on a low altitude satellite. The time-dependent properties of the model include solar activity effects, dust storm effects, seasonal and diurnal variations, and annual motion effects. Position effects are accounted for through Martian latitude and longitude. Expected values of mass density, temperature, scale height, and the estimated standard deviation of the mass density are provided. An example of the use of the model in selecting an orbit for the Mars Geochemical/Climatology Orbiter is given.

Culp, R. D.↗

Development in tunable solid state lasers with high spectral purity, high efficiency and long lifetime for differential absorption lidar

The paper presents a review of tunable vibronic solid state lasers for DIAL measurements and provides new experimental results for tunable Ti:sapphire lasers, materials development, and spectral bandwidth narrowing through injection control. Pulsed injection control of a Ti:sapphire laser with a 2.5-pm narrow band pulsed dye laser and with another Ti:sapphire laser is demonstrated with nearly complete energy extraction, indicating homogeneous line broadening. The status of tunable solid state lasers in the 1.6-2.3 micron range for DIAL measurements of trace gases, and development trends for lasers with reduced cryogenic cooling needs, are included. The effects of laser gain on optical damage, energy extraction, and amplified spontaneous emission are indicated for several tunable lasers.

Hess, R. V.↗

Performance predictions for spaceborne, long-lifetime helium dewars containing large-aperture telescopes

The evolution of design approaches for high-performance superfluid helium dewars containing large-aperture telescopes are discussed. Particular attention is given to thermal-math modeling for the IRAS and the Cosmic Background Explorer (COBE) dewars. Correlation of the recent COBE flight data with the dewar thermal-math model is presented, and apparent predictive deficiencies of the model are discussed.

Hopkins, Richard A.↗

Mechanical cooler-to-Dewar interfacing in a long-lifetime, hybrid stored cryogen system

The means for making efficient use of mechanical coolers to limit the parasitic heating into the Dewar are addressed. Thermal efficiency is achieved by minimizing the parasitic heating and thermal impedance of the cooler-to-Dewar interface within the mechanical constraints. The important issues related to compatibility with the instrument system are also briefly discussed. Parasitic heating from the nonoperating (reserved or failed) cooler pair can be reduced with an active thermal switch that isolates the cooler cold tips from the cold finger. An analysis was performed to determine the optimal switch-operating characteristics for this application. Requirements associated with the use of the coolers, analyses performed, and the interface design concept are discussed.

Hopkins, R. A.↗

Fiber optic rotation sensor for long lifetime space missions

The present F-O rotation sensors (FORS) are all-solid state devices for measuring rotations and rotation rates in inertial space that may reach the 0.003 deg/hr (1-sigma) accuracies required for NASA's Saturn-orbiting Cassini mission. Attention is presently given to the mission, inertial reference unit, and FORS instrument optoelectronic component requirements envisioned for such spacecraft applications.

Dorsky, L.↗

High-Performance, Low-Temperature-Operating, Long-Lifetime Aerospace Lubricants

The synthesis and characterization of six new ionic liquids, with fluoroether moeties on the imidazolium ring, each with vapor pressures shown to be <10(exp -7 Torr at 25 C, have been demonstrated. Thermal stability of the ionic liquids up to 250 C was demonstrated. The ionic liquids had no measurable influence upon viscosity upon addition to perfluoropolyether (PFPE) base fluids. They also had no measureable influence upon corrosion on steel substrates upon addition to base fluids. In general, 13 to 34% lower COFs (coefficients of friction), and 30 to 80% higher OK load of base fluids upon addition of the ionic liquids was shown. The compound consists of a 1,3-disubstituted imidazolium cation. The substituents comprise perfluoroether groups. A bis(trifluoromethanesulfonyl) imide anion counterbalances the charge. The fluorinated groups are intended to enhance dispersion of the ionic liquid in the PFPE base fluid. The presence of weak Van der Waals forces associated with fluorine atoms will limit interaction of the substituents on adjacent ions. The longer interionic distances will reduce the heat of melting and viscosity, and will increase dispersion capabilities.

Bergeron, Bryan↗