Search NASA⌕ Search

SEARCH · Search NASA

Results for “Low-Level Radio Frequency”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

Electron-ion collider transverse instabilities due to the crab cavity fundamental impedance

The electron-ion collider crab Cavities will present a significant transverse impedance to the beam. The low-level radio frequency system will have to reduce the crab cavity impedance to prevent transverse instabilities, while regulating the crabbing voltage and minimizing the radio frequency noise levels injected into the beam. This work presents an estimate of the crab cavity impedance in the presence of feedback and the resulting stability margins using simplified stability criteria. Generalized stability criteria are also presented in this work and are used to more accurately estimate stability margins.

43 PARTICLE ACCELERATORS↗

Evaluation of the first version of the new RFPI system dedicated to PIP-II project accelerator

The Low-Level Radio Frequency (LLRF) control system is one of the most critical superconducting linac infrastructures responsible for the parameters of the beam acceleration. The LLRF system mainly focuses on the electromagnetic field parameters inside the cavity. While it incorporates fast feedback algorithms to optimize energy transfer to the passing particle beam it does not follow other cryomodule or cavity parameter changes. The Radio Frequency Protection Interlock (RFPI) system closely monitors various factors (like cryomodule vacuum, beamline vacuum, field emission probe current level, temperature, RF signal leakage, etc). Its simple but reliable logic has to provide an instant decision about the LLRF system or high-power amplifier output signal blocking in case of safety region excitation. This contribution presents a new version of the RFPI system which logic is implemented in the FPGA chip. The initial work on the prototype of the new system design resulted in the PoC (Proof of Concept) device. The PoC offers the possibility of various protection logic configurations, input signals parameters evaluation, and modularity aspects verification. The structure and test results from the device evaluation are summarized and discussed in this contribution.

43 PARTICLE ACCELERATORS↗

Lifetime extension of legacy CEBAF LLRF hardware

A significant portion of the Low-Level Radio Frequency (LLRF) hardware in Jefferson Lab’s CEBAF is from the original construction of the facility using 1980’s CAMAC technology. Of the fifty-three zones in CEBAF, thirty-six of them are legacy hardware. The age of the legacy system has led to difficulties in maintaining the hardware due to parts going obsolete without suitable drop in replacements. Continued operation of the legacy system is required as the installation of LLRF 3.0 systems is costly and cannot be completed in a short period of time with the available resources. The most pressing failure in the legacy system was a failing buffer card, which is responsible for communication between the EPICs network and individual RF control modules. A new buffer card was designed as a transparent, drop in, replacement so that upgrades are simply a matter of swapping the existing legacy hardware. This buffer card upgrades a single point failure component and promises to extend the operable lifetime of CEBAF’s legacy systems.

Accelerator Physics↗

EIC Crab Cavity LLRF Studies

The Electron-Ion Collider Crab Cavity Low-Level Radio Frequency system will have to reduce the Crab Cavity impedance to prevent transverse instabilities, while regulating the crabbing voltage and minimizing the Radio Frequency noise levels injected to the beam. These are challenging and partly conflicting requirements. This works summarizes the specifications to achieve these requirements and investigates the possible trade-offs in the architecture.

43 PARTICLE ACCELERATORS↗

Baseband Digital Network Analyzer Upgrade for LLRF Controllers

Digital Network Analyzers (DNA) have been implemented in many Low-Level Radio Frequency (LLRF) systems, notably NSLS-II and CERN, to help tune feedback loops. DNA characterizes feedback loops by measuring the frequency-dependent magnitude and phase transfer functions. It enables the measurement of open loop gains, gain/phase margins, and loop delays to help fine-tune feedback loops. An FPGA-based DNA has been developed and integrated into the current Relativistic Heavy Ion Collider (RHIC) LLRF infrastructure. Its performance has been tested with an implementation of one-turn delay feedback (OTFB) on the bench to maximize gain and stability. The DNA has been used to characterize a RHIC 28 MHz cavity in a RHIC Accelerator Physics Experiment (APEX) to test transient beam loading compensation strategies.

43 PARTICLE ACCELERATORS↗

Radio Frequency Algorithms

Final Technical Report for DOE SC0019287 award titled Radio Frequency Algorithms. This project supported the design, simulation, analysis, and optimization of robust algorithms to configure, optimize, and control Radio Frequency and Low-Level RF systems for several modern accelerator systems.

43 PARTICLE ACCELERATORS↗

Intelligent Optimization of the Digital Low Level RF Control System for LANSCE LINAC

The LINAC at the Los Alamos Neutron Science Center (LANSCE) accelerates protons from 750 keV to its final energy at 800 MeV via 48 radio frequency (RF) modules. However, the startup and recovery process of the low-level RF (LLRF) systems, the primary controls for the RF modules, cost significant time for the beam operation, while the process itself is highly prone to human errors. With the new conversion from the analog LLRF (aLLRF) to digital LLRF (dLLRF) system under the recent LANSCE Modernization Project, new approaches with the new dLLRF capabilities can be achieved to address this issue. We propose to develop an intelligent optimization scheme that can significantly lower the downtime caused by the LLRF systems. This directly address the MFR problem statement that asks for “innovative engineering improvements to ancillary systems such as RF and pulsed power that improve reliability, maintainability, and/or performance.”

43 PARTICLE ACCELERATORS↗

Superconducting Radio-frequency Cavity Fault Classification Using Machine Learning at Jefferson Laboratory

We report on the development of machine learning models for classifying C100 superconducting radiofrequency (SRF) cavity faults in the Continuous Electron Beam Accelerator Facility (CEBAF) at Jefferson Lab. Of the 418 SRF cavities in CEBAF, 96 are designed with a digital low-level RF system configured such that a cavity fault triggers recordings of RF signals for each of eight cavities in the cryomodule. Subject matter experts analyze the collected time-series data and identify which of the eight cavities faulted first and classify the type of fault. This information is used to find trends and strategically deploy mitigations to problematic cryomodules. However, manually labeling the data is laborious and time-consuming. By leveraging machine learning, near real-time - rather than postmortem - identification of the offending cavity and classification of the fault type has been implemented. We discuss the performance of the machine learning models during a recent physics run. We also discuss efforts for further insights into fault types through unsupervised learning techniques and present preliminary work on cavity and fault prediction using data collected prior to a failure event.

Tennant, C. D.↗

Deep Learning Based Superconducting Radio-Frequency Cavity Fault Classification at Jefferson Laboratory

This work investigates the efficacy of deep learning (DL) for classifying C100 superconducting radio-frequency (SRF) cavity faults in the Continuous Electron Beam Accelerator Facility (CEBAF) at Jefferson Lab. CEBAF is a large, high-power continuous wave recirculating linac that utilizes 418 SRF cavities to accelerate electrons up to 12 GeV. Recent upgrades to CEBAF include installation of 11 new cryomodules (88 cavities) equipped with a low-level RF system that records RF time-series data from each cavity at the onset of an RF failure. Typically, subject matter experts (SME) analyze this data to determine the fault type and identify the cavity of origin. This information is subsequently utilized to identify failure trends and to implement corrective measures on the offending cavity. Manual inspection of large-scale, time-series data, generated by frequent system failures is tedious and time consuming, and thereby motivates the use of machine learning (ML) to automate the task. This study extends work on a previously developed system based on traditional ML methods (Tennant and Carpenter and Powers and Shabalina Solopova and Vidyaratne and Iftekharuddin, Phys. Rev. Accel. Beams, 2020, 23, 114601), and investigates the effectiveness of deep learning approaches. The transition to a DL model is driven by the goal of developing a system with sufficiently fast inference that it could be used to predict a fault event and take actionable information before the onset (on the order of a few hundred milliseconds). Because features are learned, rather than explicitly computed, DL offers a potential advantage over traditional ML. Specifically, two seminal DL architecture types are explored: deep recurrent neural networks (RNN) and deep convolutional neural networks (CNN). We provide a detailed analysis on the performance of individual models using an RF waveform dataset built from past operational runs of CEBAF. In particular, the performance of RNN models incorporating long short-term memory (LSTM) are analyzed along with the CNN performance. Furthermore, comparing these DL models with a state-of-the-art fault ML model shows that DL architectures obtain similar performance for cavity identification, do not perform quite as well for fault classification, but provide an advantage in inference speed.

97 MATHEMATICS AND COMPUTING↗

Machine Learning Based Cavity Fault Classification and Prediction

We report on the development of machine learning models for classifying C100 superconducting radio frequency (SRF) cavity faults in the Continuous Electron Beam Accelerator Facility (CEBAF) at Jefferson Lab. CEBAF is a continuous-wave recirculating linac utilizing 418 SRF cavities to accelerate electrons up to 12 GeV through 5-passes. Of these, 96 cavities (12 cryomodules) are designed with a digital low-level RF system configured such that a cavity fault triggers waveform recordings of 17 RF signals for each of the eight cavities in the cryomodule. Subject matter experts (SME) can analyze the collected time-series data, identify which of the eight cavities faulted first, and classify the type of fault. This information is used to find trends and strategically deploy mitigations to problematic cryomodules. However, manually labeling the data is laborious and time-consuming. By leveraging machine learning, near real-time – rather than post-mortem – identification of the offending cavity and classification of the fault type has been implemented. We discuss the performance of the ML models during a recent physics run.

43 PARTICLE ACCELERATORS↗

Transverse emittance growth due to rf noise in crab cavities: Theory, measurements, cure, and high luminosity LHC estimates

The High-Luminosity LHC (HL-LHC) upgrade with planned operation from 2029 onward has a goal of achieving a tenfold increase in the integrated number of recorded collisions thanks to a doubling of the intensity per bunch ( 2.2 × 10 11 protons) and a reduction of β * (the β value in the two high luminosity detectors, namely ATLAS and CMS) to 15 cm. Such an increase in recorded collisions would significantly expedite new discoveries and exploration. Crab cavities are an important component of the HL-LHC upgrade and will contribute strongly to achieving an increase in the number of recorded collisions. However, noise injected through the crab cavity radio frequency (rf) system could cause significant transverse emittance growth and limit luminosity lifetime. We presented a theoretical formalism relating transverse emittance growth to rf noise in an earlier work. In this follow-up paper, we summarize measurements in the super-proton synchrotron (SPS) at CERN that validate the theory, we present estimates of the emittance growth rates using state-of-the-art rf and low-level rf (LLRF) technologies, and we set the rf noise specifications to achieve acceptable performance. A novel dedicated feedback system acting through the crab cavities to mitigate emittance growth will be required. In this work, we develop a theoretical formalism to evaluate the performance of such a feedback system in any collider, identify limiting components, present simulation results to validate these studies, and derive key design parameters for an HL-LHC implementation of such a feedback system. Published by the American Physical Society 2024

43 PARTICLE ACCELERATORS↗

Study of ponderomotive instability in the FRIB beta=0.53 half-wave resonator

Superconducting radio-frequency niobium cavities are susceptible to deformations caused by external or internal forces, leading to shifts in the cavity resonant frequency. One source of deformation comes from the radiation pressure of the cavity fields, producing the so-called Lorentz force detuning effect. This effect can couple to the cavity mechanical modes in generator driven mode, leading to ponderomotive instability. In the FRIB 322 MHz, β=0.53 Half-wave Resonators (HWR), the instability appeared when the cavity was detuned, with thresholds depending on low-level RF control parameters, such as closed loop gain, as well as accelerating gradient. Using a measured Lorentz Transfer Function, Simulink simulations were conducted to predict the instability thresholds, which were then compared with the experimental results. We will discuss how these thresholds can be broadened to enable stable operation at higher gradients.

Accelerator Physics↗

Cryogenic RF characterization of the MAGO cavity for high-frequency gravitational-wave detection

Superconducting radio-frequency (SRF) cavities are promising resonant sensors for gravitational-wave detection in the kHz-MHz frequency range. We report the cryogenic RF characterization of a prototype superconducting niobium cavity with an unconventional geometry designed for narrow electromagnetic mode separation. Following an adapted surface preparation procedure, cryogenic tests were performed at Fermilab and DESY at temperatures down to 2 K. Mechanical tuning at room temperature achieved a mode splitting of approximately 11 kHz at cryogenic temperature. High electromagnetic quality factors consistent with previous prototype cavities were measured. The measurements further revealed phase transfer characteristics relevant for stable low-level RF control as well as indications of mode coupling potentially caused by one-point multipacting. In addition, first cryogenic measurements of the mechanical eigenmodes yielded mechanical quality factors significantly below commonly assumed theoretical values. These results demonstrate the successful application of established SRF preparation and characterization techniques to a non-standard resonator geometry and provide important experimental input for the development of future SRF-based gravitational-wave detectors.

Dokuyucu, Can [DESY]↗

INITIAL STUDIES OF CAVITY FAULT PREDICTION AT JEFFERSON LABORATORY

The Continuous Electron Beam Accelerator Facility (CEBAF) at Jefferson Laboratory is a CW recirculating linac that utilizes over 400 superconducting radio-frequency (SRF) cavities to accelerate electrons up to 12 GeV through 5-passes. Recent work has shown that, given RF signals from a cavity during a fault as input, machine learning approaches can accurately classify the fault type. In this paper we report on initial results of predicting a fault onset using only data prior to the failure event. A data set was constructed using time-series data immediately before a fault (’unstable’) and 1.5 seconds prior to a fault (’stable’) gathered from over 5,000 saved fault events. The data was used to train a binary classifier. The results gave key insights into the behavior of several fault types and provided motivation to investigate whether data prior to a failure event could also predict the type of fault. We discuss our method using a sliding window approach and report on initial results. Recent modifications to the low-level RF control system will provide access to streaming signals and we outline a path forward for leveraging deep learning on streaming data

Vidyaratne, Lasitha↗

INITIAL STUDIES OF CAVITY FAULT PREDICTION AT JEFFERSON LABORATORY

The Continuous Electron Beam Accelerator Facility (CEBAF) at Jefferson Laboratory is a CW recirculating linac that utilizes over 400 superconducting radio-frequency (SRF) cavities to accelerate electrons up to 12 GeV through 5-passes. Recent work has shown that, given RF signals from a cavity during a fault as input, machine learning approaches can accurately classify the fault type. In this paper we report on initial results of predicting a fault onset using only data prior to the failure event. A data set was constructed using time-series data immediately before a fault (’unstable’) and 1.5 seconds prior to a fault (’stable’) gathered from over 5,000 saved fault events. The data was used to train a binary classifier. The results gave key insights into the behavior of several fault types and provided motivation to investigate whether data prior to a failure event could also predict the type of fault. We discuss our method using a sliding window approach and report on initial results. Recent modifications to the low-level RF control system will provide access to streaming signals and we outline a path forward for leveraging deep learning on streaming data

Vidyaratne, Lasitha↗