Search NASA⌕ Search

SEARCH · Search NASA

Results for “LuSe”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

Development and characterization of the flight model spectrometer onboard LuSEE-Night

The Lunar Surface Electromagnetics Experiment - Night, LuSEE-Night, is a low-frequency radio astronomy experiment that will explore the cosmic Dark Ages signal on the radio-quiet far side of the Moon. Here, the LuSEE-Night carries a radio frequency spectrometer consisting of a set of antennas, analog and digital processing electronics, and will be launched by NASA’s Commercial Lunar Payload Services in 2025. The spectrometer is designed to observe the spectrum of the radio sky in the 0.5-50MHz band. The flight model (FM) of the four-channel spectrometer has been developed. The FM has been characterized for linearity, gain, noise, and their temperature dependence, confirming that the FM meets all the requirements for LuSEE-Night.

47 OTHER INSTRUMENTATION↗

LuSEE-night power distribution system design

The Lunar Surface Electromagnetic Experiment at Night (LuSEE-Night) is a low-frequency, 0.5 to 50 MHz, radio experiment on the radio-quiet far side of the Moon. The instrument will be launched by NASA Commercial Lunar Payload Services in 2026. The LuSEE-Night instrument core is composed of a radio frequency spectrometer (SPT) processing signals from four antennas, the Data Controller Board (DCB), low electromagnetic interference (EMI) Picket Fence Power Supply (PFPS), and Power Distribution Unit (PDU). The battery powers the instrument during the lunar night and stores energy harvested by the solar panel array during the lunar day. The battery charging is controlled by the Power Conditioning and Distribution Unit (PCDU). The unregulated power is supplied either by the SpaceCraft (S/C) or the battery and gets distributed to the PFPS, communication radio, heaters, and deployables through the PDU. The PFPS generates all regulated low-voltage rails using switching regulation synchronized to the LuSEE-Night clock, which ensures self-generated EMI will be confined to well-defined frequency bins. Here, we discussed the unregulated power distribution system architecture and functionality. The PDU engineering and flight modules are developed and characterized to confirm compliance with LuSEE-Night requirements. At the time of writing, all power subsystem components have been integrated into the payload.

47 OTHER INSTRUMENTATION↗

Design and Characterization of the Engineering Model of the Spectrometer Onboard LuSEE‐Night

Abstract The Lunar Surface Electromagnetics Explorer—Night, LuSEE‐Night, is a low‐frequency radio astronomy experiment that will explore the cosmic Dark Ages signal on the radio‐quiet farside of the Moon. The LuSEE‐Night carries a radio frequency spectrometer consisting of a set of antennas, analog and digital processing electronics, and will be launched by NASA's Commercial Lunar Payload Services in 2025. The spectrometer is designed to observe the spectrum of the radio sky in the 0.5−50 MHz band. The engineering model (EM) of the four‐channel spectrometer has been developed. The EM has been characterized for linearity, gain, noise, and their temperature dependence, confirming that the EM meets all the requirements for LuSEE‐Night. Three mitigation techniques have been implemented and verified to suppress self‐induced electromagnetic interference. The flight model of the spectrometer is currently being developed and is scheduled to be shipped to the integration site in early 2024.

Tamura, Emi↗

Design and Characterization of the Engineering Model of the Spectrometer Onboard LuSEE-Night

The Lunar Surface Electromagnetics Explorer - Night, LuSEE-Night, is a low-frequency radio astronomy experiment that will explore the cosmic Dark Ages signal on the radio quiet farside of the Moon. The LuSEE-Night carries a radio frequency spectrometer consisting of a set of antennas, analog and digital processing electronics, and will be launched by NASA's Commercial Lunar Payload Services in 2025. The spectrometer is designed to observe the spectrum of the radio sky in the 0.5−50MHz band. The engineering model (EM) of the four-channel spectrometer has been developed. The EM has been characterized for linearity, gain, noise, and their temperature dependence, confirming that the EM meets all the requirements for LuSEE-Night. Three mitigation techniques have been implemented and verified to suppress self-induced electromagnetic interference (EMI). The flight model of the spectrometer is currently being developed and is scheduled to be shipped to the integration site in early 2024

47 OTHER INSTRUMENTATION↗

Materials Data on LuSe by Materials Project

LuSe is Halite, Rock Salt structured and crystallizes in the cubic Fm-3m space group. The structure is three-dimensional. Lu is bonded to six equivalent Se atoms to form a mixture of corner and edge-sharing LuSe6 octahedra. The corner-sharing octahedral tilt angles are 0°. All Lu–Se bond lengths are 2.82 Å. Se is bonded to six equivalent Lu atoms to form a mixture of corner and edge-sharing SeLu6 octahedra. The corner-sharing octahedral tilt angles are 0°.

36 MATERIALS SCIENCE↗

Protective effects of SGLT2 inhibitor luseogliflozin on pancreatic β-cells in obese type 2 diabetic db/db mice

It is well known that Sodium-Glucose Co-transporter 2 (SGLT2) inhibitors, new hypoglycemic agents, improve glycemic control by increasing urine glucose excretion, but it remained unclear how they exert protective effects on pancreatic β-cells. In this study, we examined the effects of SGLT2 inhibitor luseogliflozin on β-cell function and mass using obese type 2 diabetic db/db mice. Ten-week-old male diabetic db/db mice were treated with luseogliflozin 0.0025% or 0.01% in chow (Luse 0.0025% or Luse 0.01%) or vehicle (control) for 4 weeks. Urinary glucose excretion was increased in Luse groups (0.0025% and 0.01%) compared to control mice 3 days after the intervention. Fasting blood glucose levels were significantly lower in mice treated with Luse compared to control mice. Fasting serum insulin concentrations were significantly higher in mice treated with Luse compared to control mice. Triglyceride levels tended to be lower in Luse groups compared to control mice. In immunohistochemical study using pancreas tissues, β-cell mass was larger in Luse groups compared to control group which was due to the increase of β-cell proliferation and decrease of β-cell apoptosis. Furthermore, in gene analysis using isolated islets, insulin 1, insulin 2, MafA, PDX-1 and GLUT2 gene expression levels were significantly higher in Luse groups compared to control group. In contrast, expression levels of fibrosis-related gene such as TGFβ, fibronectin, collagen I and collagen III were significantly lower in Luse groups. In conclusion, SGLT2 inhibitor luseogliflozin ameliorates glycemic control and thus exerts protective effects on pancreatic β-cell mass and function. - Highlights: • SGLT2 inhibitor luseogliflozin ameliorates glycemic control in db/db mice. • Luseogliflozin increases β-cell proliferation and decreases β-cell apoptosis. • Luseogliflozin preserves various β-cell-specific gene expression. • Luseogliflozin decreases various fibrosis-related factors in db/db mice.

60 APPLIED LIFE SCIENCES↗

Syntheses, Structure, Magnetism, and Optical Properties of Lutetium-based Interlanthanide Selenides

Ln{sub 3}LuSe{sub 6} (Ln = La, Ce), {beta}-LnLuSe{sub 3} (Ln = Pr, Nd), and Ln{sub x}Lu{sub 4-x}Se{sub 6} (Ln = Sm, Gd; x = 1.82, 1.87) have been synthesized using a Sb{sub 2}Se{sub 3} flux at 1000 C. Ln{sub 3}LuSe{sub 6} (Ln = La, Ce) adopt the U{sub 3}ScS{sub 6}-type three-dimensional structure, which is constructed from two-dimensional {infinity}{sup 2} [Ln{sub 3}Se{sub 6}]{sup 3-} slabs with the gaps between these slabs filled by octahedrally coordinated Lu{sup 3+} ions. The series of {beta}-LnLuSe{sub 3} (Ln = Pr, Nd) are isotypic with UFeS{sub 3}. Their structures include layers formed from LuSe6 octahedra that are separated by eight-coordinate larger Ln{sup 3+} ions in bicapped trigonal prismatic environments. Sm{sub 1.82}Lu{sub 2.18}Se{sub 6} and Gd{sub 1.87}Lu{sub 2.13}Se{sub 6} crystallize in the disordered F-Ln{sub 2}S{sub 3} type structure with the eight-coordinate bicapped trigonal prismatic Ln(1) ions residing in the one-dimensional channels formed by three different double chains via edge and corner sharing. These double chains are constructed from Ln(2)Se{sub 7} monocapped trigonal prisms, Ln(3)Se{sub 6} octahedra, and Ln(4)S{sub 6} octahedra, respectively. The magnetic susceptibilities of {beta}-PrLuSe{sub 3} and {beta}-NdLuSe{sub 3} follow the Curie-Weiss law. Sm{sub 1.82}Lu{sub 2.18}Se{sub 6} shows van Vleck paramagnetism. Magnetic measurements show that Gd{sub 1.87}Lu{sub 2.13}Se{sub 6} undergoes an antiferromagnetic transition around 4 K. Ce{sub 3}LuSe{sub 6} exhibits ferromagnetic ordering below 5 K. The optical band gaps for La{sub 3}LuSe{sub 6}, Ce{sub 3}LuSe{sub 6}, {beta}- PrLuSe{sub 3}, {beta}-NdLuSe{sub 3}, Sm{sub 1.82}Lu{sub 2.18}Se{sub 6}, and Gd{sub 1.87}Lu{sub 2.13}Se{sub 6} are 1.26, 1.10, 1.56, 1.61, 1.51, and 1.56 eV, respectively.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Electronic Forms-Based Computing for Evidentiary Analysis

The paperwork associated with evidentiary collection and analysis is a highly repetitive and time-consuming process which often involves duplication of work and can frequently result in documentary errors. Electronic entry of evidence-related information can facilitate greater accuracy and less time spent on data entry. This manuscript describes a general framework for the implementation of an electronic tablet-based system for evidentiary processing. This framework is then utilized in the design and implementation of an electronic tablet-based evidentiary input prototype system developed for use by forensic laboratories which serves as a verification of the proposed framework. The manuscript concludes with a discussion of implications and recommendations for the implementation and use of tablet-based computing for evidence analysis.

97 MATHEMATICS AND COMPUTING↗