Search NASA⌕ Search

SEARCH · Search NASA

Results for “MAGNETIC INDUCTION PROBE”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Embedded sensors integrated into critical components for in situ health monitoring of steam turbines

Operational flexibility is desired in today’s coal-fired power plants to balance power grids by compensating for the variable electricity supply from renewable energy sources and distributed gensets. This demanding requirement accelerates materials degradation and makes in-situ health monitoring essential. Life monitoring of components and subsystems is thus seen as essential in assessing material and mechanical behavior to estimate system reliability, move to a conditionbased maintenance strategy and determine time to failure of the units in their actual operating conditions. Vibration monitoring can be exploited for blade tip timing to measure blade vibration amplitude and tip clearance to detect any deterioration taking place in the condition of steam turbine blades. A failure of a rotating blade can lead to severe turbine damage followed by extensive repairs and loss of power production. A blade vibration monitoring system can help early detection of abnormal blade vibration behavior. In conjunction with a health monitoring system, the vibration characteristics can be analyzed to support a pro-active maintenance and inspection schedule. While the feasibility of this inspection technique has been amply demonstrated, there is a need to install induction probes to magnetize the blade for signal output. Siemens, in partnership with Raytheon Technologies Research Corporation (RTRC), proposes a holistic approach to develop embedded sensors to utilize radio frequency for not only coupling to sensors, but as the sensing modality. The goal of this project is to “embed” the novel sensing approach by using either additively manufactured or extruded waveguides on rotating blades for recording, evaluation and monitoring of blade vibrations in Low Pressure turbines, with applications extending to aero engines

01 COAL, LIGNITE, AND PEAT↗

Time-resolved velocity and ion sound speed measurements from simultaneous bow shock imaging and inductive probe measurements

We present a technique to measure the time-resolved velocity and ion sound speed in magnetized, supersonic high-energy-density plasmas. We place an inductive (“b-dot”) probe in a supersonic pulsed-power-driven plasma flow and measure the magnetic field advected by the plasma. As the magnetic Reynolds number is large (R M > 10), the plasma flow advects a magnetic field proportional to the current at the load. This enables us to estimate the flow velocity as a function of time from the delay between the current at the load and the signal at the probe. The supersonic flow also generates a hydrodynamic bow shock around the probe, the structure of which depends on the upstream sonic Mach number. By imaging the shock around the probe with a Mach–Zehnder interferometer, we determine the upstream Mach number from the shock Mach angle, which we then use to determine the ion sound speed from the known upstream velocity. We use the sound speed to infer the value of Z̄T e , where Z̄ is the average ionization and T e is the electron temperature. We use this diagnostic to measure the time-resolved velocity and sound speed of a supersonic (M S ~ 8), super-Alfvénic (M A ~ 2) aluminum plasma generated during the ablation stage of an exploding wire array on the Magpie generator (1.4 MA, 250 ns). The velocity and Z̄T e measurements agree well with the optical Thompson scattering measurements reported in the literature and with 3D resistive magnetohydrodynamic simulations in GORGON.

47 OTHER INSTRUMENTATION↗

The structure of 3-D collisional magnetized bow shocks in pulsed-power-driven plasma flows

Here we investigate three-dimensional (3-D) bow shocks in a highly collisional magnetized aluminium plasma, generated during the ablation phase of an exploding wire array on the MAGPIE facility (1.4 MA, 240 ns). Ablation of plasma from the wire array generates radially diverging, supersonic ($M_S$ $\sim 7$), super-Alfvénic ($M_A>1$) magnetized flows with frozen-in magnetic flux $(R_M\gg1)$. These flows collide with an inductive probe placed in the flow, which serves both as the obstacle that generates the magnetized bow shock, and as a diagnostic of the advected magnetic field. Laser interferometry along two orthogonal lines of sight is used to measure the line-integrated electron density. A detached bow shock forms ahead of the probe, with a larger opening angle in the plane parallel to the magnetic field than in the plane normal to it. Since the resistive diffusion length of the plasma is comparable to the probe size, the magnetic field decouples from the ion fluid at the shock front and generates a hydrodynamic shock, whose structure is determined by the sonic Mach number, rather than the magnetosonic Mach number of the flow. The 3-D simulations performed using the resistive magnetohydrodynamic (MHD) code Gorgon confirm this picture, but under-predict the anisotropy observed in the shape of the experimental bow shock, suggesting that non-MHD mechanisms may be important for modifying the shock structure.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Radiatively cooled magnetic reconnection experiments driven by pulsed power

We present evidence for strong radiative cooling in a pulsed-power-driven magnetic reconnection experiment. Two aluminum exploding wire arrays, driven by a 20 MA peak current, 300 ns rise time pulse from the Z machine (Sandia National Laboratories), generate strongly driven plasma flows (MA≈7) with anti-parallel magnetic fields, which form a reconnection layer (SL≈120) at the mid-plane. The net cooling rate far exceeds the Alfvénic transit rate (τcool−1/τA−1≫1), leading to strong cooling of the reconnection layer. We determine the advected magnetic field and flow velocity using inductive probes positioned in the inflow to the layer, and inflow ion density and temperature from analysis of visible emission spectroscopy. A sharp decrease in x-ray emission from the reconnection layer, measured using filtered diodes and time-gated x-ray imaging, provides evidence for strong cooling of the reconnection layer after its initial formation. X-ray images also show localized hotspots, regions of strong x-ray emission, with velocities comparable to the expected outflow velocity from the reconnection layer. These hotspots are consistent with plasmoids observed in 3D radiative resistive magnetohydrodynamic simulations of the experiment. X-ray spectroscopy further indicates that the hotspots have a temperature (170 eV) much higher than the bulk layer (≤75 eV) and inflow temperatures (about 2 eV) and that these hotspots generate the majority of the high-energy (>1 keV) emission.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Printed Circuit Board Based Rotating Coils for Measuring Sextupole Magnets

Here, the use of Printed Circuit Boards (PCBs) for the inductive pick-up windings of rotating coil probes has made the construction of these precision magnetic measurement devices much more accessible. This paper discusses the design details for PCBs which on each layer of the board provide for simultaneous analog bucking (suppression) of dipole, quadrupole, and sextupole field components so as to more accurately measure the higher order harmonic fields in sextupole magnets. Techniques to generate designs are discussed, as well as trade-offs to optimize sensitivity. Examples of recent sextupole PCBs and their performance are given.

43 PARTICLE ACCELERATORS↗

Characterizing magnetized plasmas with dynamic mode decomposition

Accurate and efficient plasma models are essential to understand and control experimental devices. Existing magnetohydrodynamic or kinetic models are nonlinear and computationally intensive and can be difficult to interpret, while often only approximating the true dynamics. In this work, data-driven techniques recently developed in the field of fluid dynamics are leveraged to develop interpretable reduced-order models of plasmas that strike a balance between accuracy and efficiency. In particular, dynamic mode decomposition (DMD) is used to extract spatio-temporal magnetic coherent structures from the experimental and simulation datasets of the helicity injected torus with steady inductive (HIT-SI) experiment. Three-dimensional magnetic surface probes from the HIT-SI experiment are analyzed, along with companion simulations with synthetic internal magnetic probes. A number of leading variants of the DMD algorithm are compared, including the sparsity-promoting and optimized DMD. Optimized DMD results in the highest overall prediction accuracy, while sparsity-promoting DMD yields physically interpretable models that avoid overfitting. These DMD algorithms uncover several coherent magnetic modes that provide new physical insights into the inner plasma structure. These modes were subsequently used to discover a previously unobserved three-dimensional structure in the simulation, rotating at the second injector harmonic. Finally, using data from probes at experimentally accessible locations, DMD identifies a resistive kink mode, a ubiquitous instability seen in magnetized plasmas.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Stray-Capacitance As a Simple Tool for Monitoring and Locating Heat Generation Demonstrated in Three Superconducting Magnets

Real-time monitoring of heat loads in cryogenic systems is critical for many applications, particularly high field magnets. In this work, we demonstrated that by monitoring changes in the capacitance of local probes consisting of thin metal strips with a porous glass fiber dielectric, boiling helium from as little as 0.1 J of deposited heat can be located by an analysis of the response speed and amplitude in nearby probes. We further implemented stray-capacitance monitoring of a magnet's metal support structures, a more global probe of the magnet volumes, in three high temperature superconducting Bi-2212 magnet types. Global structural stray-capacitance monitoring was evaluated for a single racetrack coil, a common coil dipole, and a canted cosine theta winding, showing a quench response comparable to voltage signals without inductive effects. The response of the local and global probes was compared in the single racetrack coil with well-known quench properties. Monitoring the cool-down of the common coil dipole demonstrated the added benefit of the global stray-capacitance as a liquid level monitor. This simple method of monitoring the capacitance has proven to be a versatile and robust technique for monitoring and locating heat.

43 PARTICLE ACCELERATORS↗

The CMS Magnetic Field Measuring and Monitoring Systems

This review article describes the performance of the magnetic field measuring and monitoring systems for the Compact Muon Solenoid (CMS) detector. To cross-check the magnetic flux distribution obtained with the CMS magnet model, four systems for measuring the magnetic flux density in the detector volume were used. The magnetic induction inside the 6 m diameter superconducting solenoid was measured and is currently monitored by four nuclear magnetic resonance (NMR) probes installed using special tubes outside the barrel hadron calorimeter. Two more NRM probes were installed at the faces of the tracking system. The field inside the superconducting solenoid was precisely measured in 2006 in a cylindrical volume of 3.448 m in diameter and 7 m in length using 10 three-dimensional (3D) B-sensors based on the Hall effect. These B-sensors were installed on each of the two propeller arms of an automated field-mapping machine. In addition to these measurement systems, a system for monitoring the magnetic field during the CMS detector operation has been developed. Inside the solenoid in the horizontal plane, 4 3D B-sensors were installed at the faces of the tracking detector. Twelve 3D B-sensors were installed on the surfaces of the flux-return yoke nose disks. Seventy 3D B-sensors were installed in the air gaps of the CMS magnet yoke. A specially developed flux loop technique was used for the most complex measurements of the magnetic flux density inside the steel blocks of the CMS magnet yoke. The flux loops are installed in 22 sections of the flux-return yoke blocks. The areas enclosed by these coils varied from 0.3 to 1.59 m$^{2}$ in the blocks of the barrel wheels and from 0.5 to 1.12 m$^{2}$ in the blocks of the yoke endcap disks. The development of these systems and the results of the magnetic flux density measurements across the CMS magnet are presented and discussed in this review article.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Coherent spin wave excitation with radio-frequency spin–orbit torque

Spin waves, collective perturbations of magnetic moments, are both fundamental probes for magnetic physics and promising candidates for energy-efficient signal processing and computation. Traditionally, coherent propagating spin waves have been generated by radio frequency (RF) inductive Oersted fields from current-carrying electrodes. An alternative mechanism, spin–orbit torque (SOT), offers more localized excitation through interfacial spin accumulation but has been mostly limited to DC to kHz frequencies. SOT driven by RF currents, with potentially enhanced pumping efficiency and unique spin dynamics, remains largely unexplored, especially in magnetic insulators. Here, we conduct a comprehensive theoretical and computational investigation into the generation of coherent spin waves via RF-SOT in the prototypical yttrium iron garnet. We characterize the excitation of forward volume, backward volume, and surface modes in both linear and nonlinear regimes, employing single and interdigitated electrode configurations. We reveal and explain several unique and surprising features of RF-SOT compared to inductive excitation, including higher efficiency, distinct mode selectivity, and directional symmetry, a ~ $3π/4$ phase offset, reduced anharmonic distortion in the nonlinear regime, and the absence of second harmonic generation. These insights position RF-SOT as a promising new mechanism for future magnonic and spintronic applications.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

In Situ EXAFS-Based Nanothermometry of Heterodimer Nanocrystals under Induction Heating

The ability to heat nanocrystalline materials through magnetic induction has been used in the fields of catalysis, biomedical sciences, and polymer degradation. However, the working temperature to which the inductively coupled material rises is still poorly understood. Herein, we use extended X-ray absorption fine structure spectroscopy in conjunction with thermal imaging to improve the understanding of heating in inductively coupled systems. After extraction of the Debye–Waller factor from the spectroscopy, we obtain the temperature of inductively heated nanocrystals from the correlated Debye model. We combine carbon-supported iron oxide nanocrystals as induction heating agents with platinum nanocrystals as thermal probes. By testing these nanocrystal species as both unattached nanocrystals and heterodimers, we report that nanostructured systems show a significant temperature difference of up to 73.60 °C when compared to their local support environment. Furthermore, this result has implications for inductively heated catalysis, magnetic hyperthermia for targeted cell death, and polymer synthesis.

09 BIOMASS FUELS↗

Catalytic Reaction Triggered by Magnetic Induction Heating Mechanistically Distinguishes Itself from the Standard Thermal Reaction

As a recent advancement in chemical engineering, magnetic induction heating (MIH) is utilized to initiate the intended reactions by enabling the self-heating of the ferromagnetic catalyst particles. While MIH can be energy-efficient and industrially scalable, its full potential has been underappreciated in catalysis because of the perception that MIH is merely an alternative heating approach. Unexpectedly, we show that the MIH-triggered reaction could go beyond standard thermal catalysis. Specifically, by probing the representative Pt/Fe 3 O 4 catalysts with CO oxidation in both thermal and MIH modes with consistent temperature profiles and catalyst structures, we found that the MIH mode boosts the reactivity more than 25 times by modifying Pt-FeO x interfacial synergies and promoting facile oxidation of the adsorbed carbonyl species by atomic oxygen. Further, as we preliminarily observed, this beneficial MIH-catalysis can be translational to other thermal reactions, potentially paving the way to launch MIH-catalysis as a distinct reaction category.

CO oxidation↗

Toward accurate measurement of electromagnetic field by retrieving and refining the center position of non-uniform diffraction disks in Lorentz 4D-STEM

Recent advancement in scanning transmission electron microscopy (STEM) allows the use of 4D-STEM, a technique that captures an electron diffraction pattern at each scan point in STEM, to measure electrostatic and magnetic potential and field in materials. However, accurate measurement, separation of the magnetic and electric signals, and removal of artifacts remain challenging, especially in the presence of complex non-uniform diffraction contrast within the disks. In this work, based on dynamic simulations of 4D-STEM patterns built upon superstructures consisting of millions of atoms to account for different sample thickness and edge geometries, we show how the shape and intensity distribution of the central disk are affected by multiple scattering. We propose a robust refinement procedure through iteration of the spin-sensitive peak position of the disk-center in the circular Hough transform filtered images from experimental Lorentz 4D-STEM dataset after minimizing the possible artifacts, such as those due to the change of thickness, dynamic scattering, and scanning process. We verify that caution must be taken as in practice the rigid-disk-shift model used to reconstruct induction maps can easily break down due to disk-protrusion when there exists a nonconstant phase gradient or thickness within the width of the probe. Through quantitative analysis and comparing experiment with calculation the effect of the non-spin-related intensity distribution inside the disk as well as that causes the disk shift due to the intensity-protrusion can be removed, and high-quality magnetic field mapping is possible.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Combining molecular beam epitaxy and low-energy electron microscopy with in situ magnetic susceptibility measurements within an integrated ultrahigh vacuum system

Quantum two-dimensional materials, including ultrathin superconducting films, are of great current research interest. These films are typically fabricated under ultra-high vacuum (UHV) conditions and are sensitive to the environment—prone to oxidation and contamination when exposed to the atmosphere. This hampers the study of their intrinsic properties by standard ex situ techniques. Here, we present a variable-temperature mutual inductance probe system integrated under UHV with molecular beam epitaxy (MBE) synthesis and low-energy electron microscopy, enabling nondestructive in situ characterization of superconducting thin films. The system employs a reflection-type configuration and reaches a low temperature (∼4 K) using a high-cooling-power, vibration-isolated cryocooler. In conclusion, we demonstrate the system performance by measuring the superconducting critical temperature in a copper-oxide thin film.

2D materials↗

Current distribution monitoring enables quench and damage detection in superconducting fusion magnets

Abstract Fusion magnets made from high temperature superconducting ReBCO CORC ® cables are typically protected with quench detection systems that use voltage or temperature measurements to trigger current extraction processes. Although small coils with low inductances have been demonstrated, magnet protection remains a challenge and magnets are typically operated with little knowledge of the intrinsic performance parameters. We propose a protection framework based on current distribution monitoring in fusion cables with limited inter-cable current sharing. By employing inverse Biot-Savart techniques to distributed Hall probe arrays around CORC ® Cable-In-Conduit-Conductor (CICC) terminations, individual cable currents are recreated and used to extract the parameters of a predictive model. These parameters are shown to be of value for detecting conductor damage and defining safe magnet operating limits. The trained model is then used to predict cable current distributions in real-time, and departures between predictions and inverse Biot-Savart recreated current distributions are used to generate quench triggers. The methodology shows promise for quality control, operational planning and real-time quench detection in bundled CORC ® cables for compact fusion reactors.

47 OTHER INSTRUMENTATION↗

Development of high-performance long-pulse discharge in KSTAR

High-performance long-pulse plasma operation is essential for producing economically viable fusion energy in tokamak devices. To achieve such discharges in KSTAR, firstly, the rapid increase in the temperature of plasma-facing components was mitigated. The temperature increase of the poloidal limiter, especially, was associated with beam-driven fast ion orbit loss and the discrepancy of the equilibrium reconstructed with heated magnetic probes of signal drift. The fast ions lost to the poloidal limiter were reduced by optimizing the plasma shape and the composition of neutral beam injection (NBI). This nonlinear signal drift was successfully reduced by a new thermal shielding protector on the magnetic probes. Secondly, a lower loop voltage approach was implemented to reduce a poloidal flux consumption rate. A plasma current of 400 kA and a line-averaged electron density of ~2.0 × 10 19 m –3 were chosen by considering the L–H power threshold, fast ion orbit loss, and beam shine-through power loss for low loop voltage in KSTAR. In addition, the application of electron cyclotron heating also helped maintain the plasma with low loop voltage (~25 mV) by enhancing the NBI-driven current and achieving a high poloidal beta (β P ) state. KSTAR has achieved a long pulse (~90 s) operation with the high performance of β P $\leqslant$ 2.7, thermal energy confinement enhancement factor (H 98y2 ) ~ 1.1, and fraction of non-inductive current (f NI ) $\leqslant$ 0.96. Still, gradual degradation of the plasma performance has been observed over time in the discharges. In one of the long-pulse discharges, β P reduced by ~18% over the time of ~8τ R (current relaxation time, τ R ~5 s) and ~1067τ E,th (thermal energy confinement time, τ E,th ~45 ms). The degradation may be closely associated with weak, yet growing, and persistent toroidal Alfvén eigenmodes and their effect on fast ion confinement.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

First results of the CAST-RADES haloscope search for axions at 34.67 μ eV

We present results of the Relic Axion Dark-Matter Exploratory Setup (RADES), a detector which is part of the CERN Axion Solar Telescope (CAST), searching for axion dark matter in the 34.67 μeV mass range. A radio frequency cavity consisting of 5 sub-cavities coupled by inductive irises took physics data inside the CAST dipole magnet for the first time using this filter-like haloscope geometry. An exclusion limit with a 95% credibility level on the axion-photon coupling constant of g aγ ≳ 4 × 10 -13 GeV -1 over a mass range of 34.6738 μeV < m a < 34.6771 μeV is set. This constitutes a significant improvement over the current strongest limit set by CAST at this mass and is at the same time one of the most sensitive direct searches for an axion dark matter candidate above the mass of 25 μeV. The results also demonstrate the feasibility of exploring a wider mass range around the value probed by CAST-RADES in this work using similar coherent resonant cavities.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Decoding Gas Evolution Pathways and Interfacial Chemistry in Layered Oxide Cathodes for Safer Sodium‐Ion Batteries

Sodium-ion batteries (SIBs) are attractive for the low cost and abundance of sodium. Yet, gas evolution—a critical challenge in SIBs—remains underexplored. Here, online electrochemical mass spectrometry is used to probe gas evolution in layered oxide cathodes with various compositions, cutoff voltages, dopants, and particle morphologies. Compared to LiNiO 2 (LNO), NaNiO 2 releases more gas, even at lower states of charge, due to the higher covalency of Ni─O bond caused by the more ionic Na─O bond through the inductive effect. Among Co, Mn, Al, and Mg, Mn and Mg doping suppress gas release most effectively by enhancing the metal-oxygen bond strength. NaNi 1/3 Fe 1/3 Mn 1/3 O 2 (NFM) cathodes synthesized via coprecipitation (CP-NFM) and solid-state routes exhibit distinct particle morphologies; CP-NFM exhibits more gas evolution, yet secondary particle morphology helps reduce it through differential cathode-electrolyte reactivity between inner and outer primary particles. Among Li, Ti, Mg, and Cu doping in NFM, Li has the largest effect, reducing gas levels comparable to LNO. Nuclear magnetic resonance and X-ray photoelectron spectroscopies reveal that electrolyte solvent decomposition mainly produces organic-rich cathode-electrolyte interphase (CEI) rather than soluble species. NaPF 6 salt further exacerbates cathode-electrolyte reactions, forming surface Na 2 O species. The findings provide actionable guidance for designing safer, durable SIBs.

25 ENERGY STORAGE↗