Search NASA⌕ Search

SEARCH · Search NASA

Results for “MAGNETIC MIRRORS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Fusion by beam ions in a low collisionality, high mirror ratio magnetic mirror

Abstract The classical problem of neutral beam ions slowing down in a magnetic mirror geometry is revisited to provide predictive capability for the new Wisconsin HTS Axisymmetric Mirror under development at the University of Wisconsin. A Fokker–Planck model named fast beam ion solver (FBIS) is developed to include the spatial non-uniformity of a physical mirror geometry. The mathematical framework allows for efficient orbit averaging of the pitch-angle scattering operator, and permits a determination of the axial profile of the ambipolar potential confining the electrons. The numerical results from FBIS are consistent with earlier work, but further show how mirror-ratio and a near square magnetic well optimizes the fusion gain. The numerical results are also applied to inform the conceptual design of WHAM++, a low capital-cost breakeven-class magnetic mirror device.

Egedal, J. (ORCID:0000000177531529)↗

Particle deconfinement in a bent magnetic mirror

Coils misalignment in a magnetic mirror can produce additional particle transport. The magnetic field non axi-symmetry is responsible for radial and longitudinal drifts in a way much similar to the neo-classical transport in a tandem mirror cell distorted by end plugs. Accordingly, a regime exhibiting large radial displacements--similar to the resonant regime in tandem mirrors--can be obtained by confining ions azimuthally, for example by means of a properly tuned radial electric field. Because of the mass dependence of the magnetic field non-homogeneity drift velocities, the azimuthal trapping is mass specific, allowing, in principle, the filtering of a specific species based on its mass.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Properties and parameters of the electron beam injected into the mirror magnetic trap of a plasma accelerator

The parameters of the injector of an axial plasma beam injected into a plasma accelerator operating on the basis of gyroresonance acceleration of electrons in the reverse magnetic field are determined. The trapping of the beam electrons into the regime of gyroresonance acceleration is numerically simulated by the particle- in-cell method. The optimal time of axial injection of the beam into a magnetic mirror trap is determined. The beam parameters satisfying the condition of efficient particle trapping into the gyromagnetic autoresonance regime are found.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Test of Optimized 120-mm LARP Nb 3 Sn Quadrupole Coil Using Magnetic Mirror Structure

The U.S. Large Hadron Collider accelerator research program is developing a new generation of large-aperture high-field quadrupoles based on Nb 3 Sn conductor for the high-luminosity upgrade of the Large Hadron Collider. Tests of the first series of 120-mm-aperture high-gradient quadrupole (HQ) coils revealed the necessity for further optimization of the coil design and fabrication process. Modifications in coil design were gradually implemented in two HQ coils previously tested at Fermi National Accelerator Laboratory using a magnetic mirror structure (HQM01 and HQM02). This paper describes the construction and test of an HQ mirror model with a coil of optimized design and with an interlayer resistive core in the conductor. The cable for this coil was made of a smaller diameter strand, providing more room for coil expansion during reaction. The 0.8-mm strand, used in all previous HQ coils, was replaced with a 0.778-mm Nb 3 Sn strand of RRP 108/127 subelement design. The coil was instrumented with voltage taps, heaters, and strain gauges to monitor mechanical and thermal properties and quench performance of the coil

43 PARTICLE ACCELERATORS↗

Confinement of relativistic electrons in a magnetic mirror en route to a magnetized relativistic pair plasma

Creating a magnetized relativistic pair plasma in the laboratory would enable the exploration of unique plasma physics relevant to some of the most energetic events in the universe. As a step toward a laboratory pair plasma, we have demonstrated an effective confinement of multi-MeV electrons inside a pulsed-power-driven 13 T magnetic mirror field with a mirror ratio of 2.6. The confinement is diagnosed by measuring the axial and radial losses with magnetic spectrometers. The loss spectra are consistent with ≤2.5 MeV electrons confined in the mirror for ∼1 ns. With a source of 1012 electron-positron pairs at comparable energies, this magnetic mirror would confine a relativistic pair plasma with Lorentz factor γ∼6 and magnetization σ∼40.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Energy spectrum of lost alpha particles in magnetic mirror confinement

In a magnetic mirror fusion reactor, capturing the energy of fusion-produced alpha particles is essential to sustaining the reaction. However, since alpha particles are born at energies much higher than the confining potential, a substantial fraction are lost due to pitch-angle scattering before they can transfer their energy to the plasma via drag. The energy of lost alpha particles can still be captured through direct conversion, but designing an effective mechanism requires a description of the energies and times at which they become deconfined. Here we present analytical solutions for the loss velocity, energy, and time distributions of alpha particles in a magnetic mirror. After obtaining the Fokker-Planck collision operator, we asymptotically solve for the eigenfunctions of the Legendre operator to reveal a closed-form solution. In conclusion, our framework applies to any high-energy species, for any applied potential and mirror ratio R > 1, making this work broadly applicable to mirror devices.

Confinement↗

The Marshall Magnetic Mirror Beam-Plasma Experiment

Plasma propulsion is an advanced propulsion concept with the potential to realize very high specific impulse. Present designs for plasma propulsion devices share a common feature, the incorporation of a magnetic mirror. A magnetic mirror is a plasma confinement scheme whereby charged particles are trapped (or reflected) between two regions of high magnetic field strength. A cylindrical geometry is most often employed to create a magnetic mirror, which is a natural geometry for propulsion devices. To utilize the magnetic mirror configuration in a plasma propulsion device, however, will require efficient coupling of power into the system. With the development of compact and efficient electron sources, such as hollow cathode sources, coupling power into a magnetic mirror using electron beams may be an attractive approach. A system, the Marshall Magnetic Mirror (M3), has been constructed to study the coupling of an electron beam into a magnetic mirror. A description of the M3 device will be provided as well as data from initial beam-plasma coupling experiments.

Schneider, Todd A.↗

Ion Beam Neutralization Using FEAs and Mirror Magnetic Fields

Advanced implantation systems used for semiconductor processing require transportation of ion beams which are quasi-parallel and have low energy, such as ({sup 11}B{sup +},{sup 31}P{sup +},{sup 75}As{sup +}) with energy in the range E{sub ion} 200-1000 eV. Compensation of ion beam divergence may be obtained through electron injection and confinement in regions of non-uniform magnetic fields. Field emitter arrays with special properties are used as electron sources. The present study shows that electron confinement takes place in regions of gradient magnetic field, such as nearby analyzing, collimator and final energy magnets of the ion beam line. Modeling results have been obtained using Opera3D/Tosca/Scala. In regions of gradient magnetic field, electrons have helical trajectories which are confined like a cloud inside curved 'magnetic bottles'. An optimal range of positions with respect to the magnet for placing electron sources in gradient magnetic field has been shown to exist.

43 PARTICLE ACCELERATORS↗

Particle Deconfinement in a Bent Magnetic Mirror

Coils misalignment in a magnetic mirror can produce additional particle transport. The magnetic field non axi-symmetry is responsible for radial and longitudinal drifts in a way much similar to the neo-classical transport in a tandem mirror cell distorted by end plugs. Accordingly, a regime exhibiting large radial displacements - similar to the resonant regime in tandem mirrors - can be obtained by confining ions azimuthally, for example by means of a properly tuned radial electric field. Because of the mass dependence of the magnetic field non-homogeneity drift velocities, the azimuthal trapping is mass specific, allowing in principle the filtering of a specific species based on its mass.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Phase-Controlled Magnetic Mirror for Wavefront Correction

Typically, light interacts with matter via the electric field and interaction with weakly bound electrons. In a magnetic mirror, a patterned nanowire is fabricated over a metallic layer with a dielectric layer in between. Oscillation of the electrons in the nanowires in response to the magnetic field of incident photons causes a re-emission of photons and operation as a "magnetic mirror." By controlling the index of refraction in the dielectric layer using a local applied voltage, the phase of the emitted radiation can be controlled. This allows electrical modification of the reflected wavefront, resulting in a deformable mirror that can be used for wavefront control. Certain applications require wavefront quality in the few-nanometer regime, which is a major challenge for optical fabrication and alignment of mirrors or lenses. The use of a deformable magnetic mirror allows for a device with no moving parts that can modify the phase of incident light over many spatial scales, potentially with higher resolution than current approaches. Current deformable mirrors modify the incident wavefront by using nano-actuation of a substrate to physically bend the mirror to a desired shape. The purpose of the innovation is to modify the incident wavefront for the purpose of correction of fabrication and alignment-induced wavefront errors at the system level. The advanced degree of precision required for some applications such as gravity wave detection (LISA - Laser Interferometer Space Antenna) or planet finding (FKSI - Fourier-Kelvin Stellar Interferometer) requires wavefront control at the limits of the current state of the art. All the steps required to fabricate a magnetic mirror have been demonstrated. The modification is to apply a bias voltage to the dielectric layer so as to change the index of refraction and modify the phase of the reflected radiation. Light is reflected off the device and collected by a phase-sensing interferometer. The interferometer determines the initial wavefront of the device and fore optics. A wavefront correction is calculated, and voltage profile for each nanowire strip is determined. The voltage is applied, modifying the local index of refraction of the dielectric under the nanowire strip. This modifies the phase of the reflected light to allow wavefront correction.

Hagopian, John↗

Fabrication and Test of an Optical Magnetic Mirror

Traditional mirrors at optical wavelengths use thin metalized or dielectric layers of uniform thickness to approximate a perfect electric field boundary condition. The electron gas in such a mirror configuration oscillates in response to the incident photons and subsequently re-emits fields where the propagation and electric field vectors have been inverted and the phase of the incident magnetic field is preserved. We proposed fabrication of sub-wavelength-scale conductive structures that could be used to interact with light at a nano-scale and enable synthesis of the desired perfect magnetic-field boundary condition. In a magnetic mirror, the interaction of light with the nanowires, dielectric layer and ground plate, inverts the magnetic field vector resulting in a zero degree phase shift upon reflection. Geometries such as split ring resonators and sinusoidal conductive strips were shown to demonstrate magnetic mirror behavior in the microwave and then in the visible. Work to design, fabricate and test a magnetic mirror began in 2007 at the NASA Goddard Space Flight Center (GSFC) under an Internal Research and Development (IRAD) award Our initial nanowire geometry was sinusoidal but orthogonally asymmetric in spatial frequency, which allowed clear indications of its behavior by polarization. We report on the fabrication steps and testing of magnetic mirrors using a phase shifting interferometer and the first far-field imaging of an optical magnetic mirror.

Hagopian, John G.↗

On the magnetic mirroring as the basic cause of parallel electric fields

Among the different proposed mechanisms for generating parallel electric fields, magnetic mirroring of charged particles seems to be the most plausible. In the present paper, it is suggested that magnetic mirroring is the basic cause of parallel electric fields in the magnetosphere and that the magnetic mirroring effect may be able to form the basis of an auroral theory that can remove a major portion of the ambiguity of observations. In the model proposed, the parallel electric field is due to a magnetic confinement of a negatively charged hot collision-free plasma. A transfer of electron gyroenergy into wave energy tends to weaken this confinement; if this energy transfer becomes too strong, the parallel potential gradient will break down. Hence, from this model, in contrast to certain other models of parallel electric fields, only a small fraction of the total auroral particle energy may be expected to be transformed into electromagnetic wave energy during the acceleration process.

Lennartsson, W.↗

Enhanced loss of magnetic-mirror-trapped fast electrons by a shear Alfvén wave

Laboratory observations of enhanced loss of magnetic mirror trapped fast electrons irradiated by a shear Alfvén Wave (SAW) are reported. The experiment is performed in the quiescent after-glow plasma in the Large Plasma Device [Gekelman et al., Rev. Sci. Instrum. 62(12), 2875–2883 (1991)]. A trapped energetic electron population (>100 keV) is generated in a magnetic mirror section (mirror ratio ≈ 2, length = 3.5 m) by an X-mode high power microwave pulse, and forms a hot electron ring due to the grad-B and curvature drift. SAWs of arbitrary polarization are launched externally by a Rotating Magnetic Field source (δB/B{sub 0} ≈ 0.1%, λ{sub ∥} ≈ 9 m). Irradiated by a right-handed circularly polarized SAW, the loss of electrons, in both the radial and the axial direction of the mirror field, is significantly enhanced and is modulated at f{sub Alfvén}. The periodical loss continues even after the termination of the SAW. Experimental observations suggest that a spatial distortion of the ring is formed in the SAW field and creates a collective mode of the hot electron population that degrades its confinement and leads to electron loss from the magnetic mirror. The results could have implications on techniques of radiation belt remediation.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Enhanced Collisional Losses from a Magnetic Mirror Using the Lenard-Bernstein Collision Operator

Collisions are crucial in governing particle and energy transport in plasmas confined in a magnetic mirror trap. Modern gyrokinetic codes model transport in magnetic mirrors, but some utilize approximate model collision operators. This study focuses on a Pastukhov-style method of images calculation of particle and energy confinement times using a Lenard-Bernstein model collision operator. Prior work on parallel particle and energy balances used a different Fokker-Planck plasma collision operator. The method must be extended in non-trivial ways to study the Lenard-Bernstein operator. To assess the effectiveness of our approach, we compare our results with a modern finite element solver. Our findings reveal that the particle confinement time scales like a exp( a 2 ) using the Lenard-Bernstein operator, in contrast to the more accurate scaling that the Coulomb collision operator would yield a 2 exp( a 2 ), where a 2 is approximately proportional to the ambipolar potential. We propose that codes solving for collisional losses in magnetic mirrors utilizing the Lenard-Bernstein or Dougherty collision operator scale their collision frequency of any electrostatically confined species. This study illuminates the collision operator’s intricate role in the Pastukhov-style method of images calculation of collisional confinement.

fusion plasma↗

Mirror Magnetic Field and Its Impact on Dark Matter Distribution in Galaxies

We obtain the value of the mirror magnetic field during different stages of cosmological evolution. We consider the magnetic field generation in the radiation-dominated era and the post-recombination epoch. We also estimate its galactic low-scale value in the process of dynamo amplification. We discuss a possible effect of the mirror magnetic field on the mirror matter distribution in a galaxy. The model can be generalized by assuming the existence of kinetic mixing between ordinary and mirror particles.

79 ASTRONOMY AND ASTROPHYSICS↗