Search NASA⌕ Search

SEARCH · Search NASA

Results for “MAGNETIC TAPE”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Study of Critical Current and n-Values of 2G HTS Tapes: Their Magnetic Field-Angular Dependence

Since many applications of YBCO tapes operate in external magnetic fields, it is necessary to investigate the magneto-angular dependence of critical current and n-values in coated conductors. In this paper, five commercial YBCO tapes with different microstructures produced by three different manufacturers are chosen. The selected samples have a width of 2.0, 4.0, 4.8, 6.0 or 12 mm, with copper, brass or stainless steel laminations. The critical current density dependence J{sub c}(B, θ) and n-values characteristics n(B, θ) of the tapes are comprehensively measured under various magnetic fields and orientations. Afterwards, the obtained experimental data sets are successfully fitted using a novel multi-objective model which considers the material anisotropy. By using this approach, a fitting function I{sub c}(B, θ) can always be obtained to accurately describe the experimental data, regardless of the fabrication and width differences of the superconducting tapes. Moreover, our experiment shows that when subject to different external magnetic fields, the angular dependence of n-values characteristics is directly correlated with the corresponding critical current profiles. Our results are helpful to predict the critical current of electromagnetically interacting 2G HTS wires, thereby improving the design and performance of the devices made from YBCO tapes.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

An Exact Algorithm for the Linear Tape Scheduling Problem

Magnetic tapes are often considered as an outdated storage technology, yet they are still used to store huge amounts of data. Their main interests are a large capacity and a low price per gigabyte, which come at the cost of a much larger file access time than on disks. With tapes, finding the right ordering of multiple file accesses is thus key to performance. Moving the reading head back and forth along a kilometer long tape has a non-negligible cost and unnecessary movements thus have to be avoided. However, the optimization of tape request ordering has rarely been studied in the scheduling literature, much less than I/O scheduling on disks. For instance, minimizing the average service time for several read requests on a linear tape remains an open question. Therefore, in this paper, we aim at improving the quality of service experienced by users of tape storage systems, and not only the peak performance of such systems. To this end, we propose a reasonable polynomial-time exact algorithm while this problem and simpler variants have been conjectured NP-hard. We also refine the proposed model by considering U-turn penalty costs accounting for inherent mechanical accelerations. Then, we propose a low-cost variant of our optimal algorithm by restricting the solution space, yet still yielding an accurate suboptimal solution. Finally, we compare our algorithms to existing solutions from the literature on logs of the mass storage management system of a major datacenter. This allows us to assess the quality of previous solutions and the improvement achieved by our low-cost algorithm. Aiming for reproducibility, we make available the complete implementation of the algorithms used in our evaluation, alongside the dataset of tape requests that is, to the best of our knowledge, the first of its kind to be publicly released.

Honoré, Valentin↗

Design of Fluxgate Sensors for Different Applications from Geology to Medicine

In this study, we have shown that fluxgate sensors can be used for different application areas. Alternative sensor configurations have been developed for three different application areas. These are mainly rod- and ring-type fluxgate sensors. In the first study, a measurement system with the rod-type fluxgate sensor has been developed in order to monitor the local magnetic field distributions on a magnetic tape (e.g., credit card). With this system, the magnetic recording data on the credit card were measured and imaged successfully. The second and the third application areas, which are monitoring the influence of solar storms on the earth field and heartbeat analysis of mankind, were carried out by using a ring-core fluxgate sensor geometry.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Calculation of AC Magnetizing Loss of ReBCO Superconducting Tapes Subjected to Applied Distorted Magnetic Fields

In recent years, there are fast-increasing concerns on the utilizations of superconducting rotating electrical machines in different application areas, such as ship propulsion systems, aircraft drivers, and wind turbine generators, since these machines exhibit the merits of high current density, compact design, high power density, light weight, high torque density as well as high efficiency. One of the main limitations in front of the vast use of superconducting tapes in the fabrication of electrical machineries is AC magnetizing loss when tapes are exposed to an external magnetic field, which can decrease the critical current density of wires, as well. In the literature, most of the research works have been done on calculation of the AC magnetizing loss under a pure external magnetic field, while in reality, magnetic flux lines in AC electrical machines are usually distorted with harmonics because of different reasons such as distorted leakage flux, distributed coils of a winding in several slots, cogging fields, mechanical faults, etc. Since these distorted fields contain harmonics, then in this paper, the AC magnetizing loss of superconducting tapes has been electromagnetically modeled and calculated when they are subjected to nonsinusoidally distorted external magnetic fields. The magnetic field dependency of critical current density has been considered in a proposed finite element model. The results have shown that the AC magnetizing loss increases significantly under a distorted applied field compared with a sinusoidal one. In addition, the loss increase depends on the harmonic content which would increases drastically with total harmonic distortion of the applied magnetic field.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

A Non-contact Apparatus for Measuring Longitudinal Critical Current of REBCO Tapes Using the Magnetic Circuit Method

This paper details the design and construction of a non-contact apparatus that can measure the longitudinal critical current of REBCO tapes based on magnetic circuit method. A 3D finite element model was proposed to study the relation between I{sub c} (critical current of the REBCO tape) and B{sub H} (magnetic field at the Hall sensor). The proportionality coefficient of I{sub c} and B{sub H} was obtained by using the said model. Several experiments on the REBCO tapes were conducted to determine the repeatability, reliability, and accuracy of the apparatus. Four parameters (average value, minimum value, the range, and the coefficient of critical current variation (COV)) were used to determine the repeatability and accuracy of the apparatus. It was observed that transmission speed affects test results because of relaxation of the magnetic flux. Another tape was tested at different transmission speeds to study the relation between B{sub H} and decay time. From the results, a principle formula was established to explain the relation between B{sub H} and decay time, and it was shown that the test results also take the same form as the principle formula.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Examining the Impact of Data Layout on Tape on Data Recall Performance for ATLAS

Increases in data volumes are forcing high-energy and nuclear physics experiments to store more frequently accessed data on tape. Extracting the maximum performance from tape drives is critical to make this viable from a data availability and system cost standpoint. The nature of data ingest and retrieval in an experimental physics environment make achieving high access performance difficult given the inherent limitations of magnetic tape. Tailoring the layout of data on tape is one key to improving read performance. This paper highlights the work in progress to characterize ATLAS data ingested in the tape system, understand how data layout, i.e. file co-location on tape and file distribution over tapes, affect read performance and how optimal data layout might be achieved in a production environment.

99 GENERAL AND MISCELLANEOUS↗

Evaluating the risk of data loss due to particle radiation damage in a DNA data storage system

DNA data storage is a potential alternative to magnetic tape for archival storage purposes, promising substantial gains in information density. Critical to the success of DNA as a storage media is an understanding of the role of environmental factors on the longevity of the stored information. In this paper, we evaluate the effect of exposure to ionizing particle radiation, a cause of data loss in traditional magnetic media, on the longevity of data in DNA data storage pools. We develop a mass action kinetics model to estimate the rate of damage accumulation in DNA strands due to neutron interactions with both nucleotides and residual water molecules, then utilize the model to evaluate the effect several design parameters of a typical DNA data storage scheme have on expected data longevity. Finally, we experimentally validate our model by exposing dried DNA samples to different levels of neutron irradiation and analyzing the resulting error profile. Our results show that particle radiation is not a significant contributor to data loss in DNA data storage pools under typical storage conditions.

97 MATHEMATICS AND COMPUTING↗

Specification of EBR-II Laser Profilometry Data

All laser profilometry data stored in FIPD were originally measured using the element laser profilometer system in HFEF/N. The irradiated fuel elements or pins were scanned by a laser beam to measure the outer diameter with position mapping of the spacer wire. The normal operation and data collection were performed automatically with HFEF/N Data Acquisition and Process Control System (DAPCS). With the digital control system, measured laser profilometry data were recorded in digital form on magnetic tapes, different from the analog contact profilometry data recorded by strip-chart record sheets. Two documents contained most of the important details about laser profilometry measurements. The first one is the operational manual of the laser profilometer (title: Element laser profilometer (ELP) operation and maintenance manual, HFEF/N OMM 4329, DOC. NO. W0171-0149-ES-01). This manual provides: (1) description of laser profilometer including the functions of each component (transceiver, retroreflector, clamping guide, shielding enclosure, electronic controller, etc.); (2) step-by-step guidance for calibrations, operations and measurements; and (3) maintenance procedures and other details of the element laser profilometer. Since first issued on 12/1/1986, several revisions/changes of the manual were developed to update the measurement accuracies and other factors for the laser profilometer system. The second document is a publicly accessible conference article titled “the element laser profilometer system in HFEF/N.” This article summarizes important functions and parameters of the laser profilometer. The range of measurements and the uncertainties reported in the article were consistent with the values reported in the operational manual.

42 ENGINEERING↗

Investigation on Effect of Magnetic Field Dependency Coefficient of Critical Current Density on the AC Magnetizing Loss in HTS Tapes Exposed to External Field

High-temperature superconducting (HTS) technology is the most promising, advanced, and beneficial technological developments of the last two decades in terms of fabricating more efficient, compact, and reliable electrical power apparatus. The second-generation HTS wires are now quite competitive with traditional conductors from the cost point of view. In addition, they are of high interest in electrical machine manufacturing due to their unique merits such as high current density, high magnetic field, and low loss. The most significant issue for any superconducting devices which work with alternating current or magnetic field is the AC loss of the HTS tapes. Since HTS tapes are always exposed to an external magnetic field in electrical machine applications, it is vital to consider the effect of this external field on their AC magnetizing (ACMG) loss. It is well-known that external magnetic field decreases the current carrying capability of the wire. In real life, critical current density of HTS tapes is dependent to magnetic field but this dependency sometime was not considered in modeling stage in order to make it faster and simple. In this paper, the electromagnetic properties of HTS tapes for use in superconducting electric machines have been investigated with a particular focus on the ACMG loss of YBCO tapes. For this purpose, a two-dimensional finite element model has been implemented based on the H formulation in order to study the effect of dependency of critical current density to magnetic field on the variation of ACMG loss. The modeling results will be helpful for electrical machine designers to have a better understanding about this effect and have a more accurate estimate of ACMG loss in design stage.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Ribbon Wrinkling Origin and Its Effect on Tape-Wound Core Shape

Improved understanding of advanced manufacturing techniques is needed to fabricate next- generation soft magnetic tape-wound cores. These utilize metal amorphous nano-composites (MANCs) in the form of long thin ribbons. MANCs exhibit attractive soft magnetic properties for use in high frequency and high power density magnetic components. Of particular interest here, the permeability and hysteresis of MANC ribbons can be tuned in a strain annealing process. An unexpected consequence is that wider ribbons develop longitudinal wrinkle patterns. This can substantially reduce the tape-wound core stacking factor. However, when winding a wrinkled ribbon into a toroidal core, the wrinkles can completely flatten, or crinkle. By this phenomenon, the stacking factor can be recovered. To understand the crinkling effect we have developed analytical and finite element analysis (FEA) models. Experiments with known boundary conditions demonstrate the transition from wrinkled to crinkled versus winding curvature. The models utilize an elastic modulus measured via ribbon tensile testing and a ribbon thickness value measurement made by profilometry. The analytical model provides insight into the crinkling effect but cannot explain the length of the transition region from wrinkling to crinkling. With FEA, we successfully predict the transition region and depending on wrinkling amplitude can determine when a ribbon will wind into a useable core. Such mechanics-based insight provides critical feedback for allowable processing parameters in the strain annealing process.

20 FOSSIL-FUELED POWER PLANTS↗

Recovery and Calibration of Legacy Underground Nuclear Test Seismic Data from the Leo Brady Seismic Network

The Leo Brady Seismic Network (LBSN, originally the Sandia Seismic Network) was established in 1960 by Sandia National Laboratories to monitor underground nuclear tests (UGTs) at the Nevada National Security Site (NNSS, formerly named the Nevada Test Site). The LBSN has been in various configurations throughout its existence, but it has generally been comprised of four to six stations at regional distances (~150–400 km) from the NNSS with approximately evenly spaced azimuthal coverage. Between 1962 and the end of nuclear testing in 1992, the LBSN—and a sister network operated by Lawrence Livermore National Laboratories—was the most comprehensive United States source of regional seismic data of UGTs. Approximately 75% of all UGTs performed by the United States occurred in the predigital era. At that time, LBSN data were transmitted as frequency-modulated (FM) audio over telephone lines to a central location and recorded as analog waveforms on high-fidelity magnetic audio tapes. These tapes have been in dry temperature-stable storage for decades and contain the sole record of this irreplaceable data; full waveforms of LBSN-recorded UGTs from this era were not routinely digitized or otherwise published. We have developed a process to recover and calibrate data from these tapes. First, we play back and digitize the tapes as audio. Next, we demodulate the FM “audio” into individual waveforms. We then estimate the various instrument constants through careful measurement of “weight-lift” tests performed prior to each UGT on each instrument. Finally, these coefficients allow us to scale and shape the derived instrument response of the seismographs and compute poles and zeros. Finally, the result of this process is a digital record of the recorded seismic ground motion in a modern data format, stored in a searchable database. To date, we have digitized tapes from 592 UGTs.

58 GEOSCIENCES↗

Electromechanical Properties of 1-mm-Wide Superconducting Cables Comprised of Exfoliated YBCO Filaments

Development of multifilament YBCO cables is an important step toward the manufacture of practical superconducting magnets based on second generation high-temperature superconductor technology. Currently, magnets manufactured from wide 2G tapes suffer from high magnetization loss and poor reliability. The presence of an insulation substrate is to insulate YBCO layers from each other, which allows only lateral (along the tape face) current sharing. Here we present an exfoliated multilayer cable with electrically coupled (1 mm wide) filaments that permit normal (across the tape) current sharing within the cable. Finally, this development can potentially enable fast ramping and stable high-field magnets for applications in fusion, energy storage, and transportation.

2G conductor↗

A 1.2 T canted cos $θ$ dipole magnet using high-temperature superconducting CORC ® wires

In this study, REBa 2 Cu 3 O x (REBCO, RE = rare earth elements) coated conductors can carry high current in high background fields, in principle enabling dipole magnetic fields beyond 20 T. Although model accelerator magnets wound with single REBCO tapes have been successfully demonstrated, magnet technology based on high-current REBCO cables for high-field accelerator magnet applications has yet to be established. We developed a two-layer canted cosθ dipole magnet with an aperture of 70 mm using 30 m long commercial Conductor on Round Core (CORC ® ) wires. The 3.1 mm diameter CORC ® wire contained 16 commercial REBCO tapes with a 30 $μ$m thick substrate. The magnet was tested at 77 and 4.2 K. It generated a peak dipole field of 1.2 T with 4.8 kA at 4.2 K with neither thermal runaway nor training. Reasonable geometric field quality and strong magnetization-current effects with multipole decay were observed. Our work demonstrated a feasible high-temperature superconducting magnet technology as a first step toward a new accelerator magnet paradigm that will enable high-field inserts for next-generation circular colliders and stand-alone magnets that can operate over a wide temperature range for a broad range of applications.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Investigation of HTS Twisted Stacked-Tape Cable (TSTC) Conductor for High-Field, High-Current Fusion Magnets

The critical currents of a twisted single-tape were measured at 4.2 K in fields up to 17 T. It was confirmed that the critical current of a twisted-tape was similar to that of a flat tape in c-axis fields. Based on the single-tape critical-currents, a 40-tape (4-mm width) twisted stacked-tape cable (TSTC) conductor was experimentally evaluated at fields up to 17 T at 4.2 K. It was found that the Lorentz load degradation of the TSTC conductor was negligible at the end of a cyclic test. The TSTC cabling method has been considered to be suitable for developing a high-field high-current REBCO conductor for magnet applications as well as power transmission cables. A method to fabricate the inner legs of a D-shape toroidal field coil using a TSTC conductor has been discussed. This method allows the conductor to properly resist the transverse Lorentz load and mitigate ac loss issues by adopting a parallel-HTS-tape flat cable configuration where necessary.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

A Field Quality Modeling in Canted Cosine Theta Dipole Magnets Wound Using REBCO Cables

In accelerator magnets the magnetic field quality is an important parameter. Using REBCO tapes or cables in magnet windings affects the magnetic field quality because of a quite high magnetization generated by these conductors. In this paper we analyzed numerically (using FEM) an effect of various REBCO cables’ magnetization on the field quality of canted cosine theta (CCT) dipole magnets. The magnetic properties of the cables were taken from our measurements of their M (H) curves at 4.2 K and magnetic fields up to 12 T. Also, flux creep effects were measured and their effects on field quality analyzed. Here we present a modeling of a CCT magnet containing 1 dipole double layer wound using a CORC and STAR cable. To make the FEM modeling less computationally “expensive”, we modelled only a section of 10 turns of the magnet's central part and calculated b3 fields on a circle of 2/3 of the innermost layer center line. Special M (H) curves measured during various field cycles (the so called “pre-injection cycles”) are effective in decreasing b 3 fields of the magnets. Flux creep effects suppress the b 3 fields further. In conclusion, using these techniques b 3 fields less than 10 units can be achieved.

36 MATERIALS SCIENCE↗

Final Report: Performance-structure characterization to improve REBCO Fusion conductor production at SuperPower

Several companies have used ReBCO tapes to make magnets operating at 20 K, at magnetic fields up to 20T suitable for plasma confining for controlled fusion applications. The transport properties of ReBCO conductors should be optimized for such conditions. NHMFL is one of the few laboratories where such tests can be accomplished. Recently, SuperPower Inc. came up with a new product, REBCO MOCVD HM tape, optimized for plasma confining applications. These HM tapes are designed to have increased critical currents at intermediate temperatures of 4.2K

36 MATERIALS SCIENCE↗