Search NASA⌕ Search

SEARCH · Search NASA

Results for “MAGNETOMETERS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

High-sensitivity multi-channel atomic magnetometer

High-sensitivity multi-channel atomic magnetometers are described. Methods for operating multi-channel atomic magnetometers are also described. Moreover, devices incorporating a plurality of multi-channel atomic magnetometers are described. A multi-channel atomic magnetometer may use the spin-exchange relaxation-free (SERF) technique. A multi-channel atomic magnetometer may achieve multi-channel operation in a single module, reducing the cost of sensors. A multi-channel atomic magnetometer may be a 16-channel atomic magnetometer. A multi-channel atomic magnetometer may include a single large vapor cell including alkali-metal atoms and at least one buffer gas that restricts motion of atomic spins of the alkali-metal atoms, thereby making relatively small internal cell volumes act as a multiple independent local sensing channels. A multi-channel atomic magnetometer may include a broad pump beam that simultaneously polarizes all (or substantially all) of the alkali-metal atoms in each internal sensing volume of the vapor cell, and a broad probe beam that simultaneously measures magnetic fields at multiple sensing volumes with a photodiode array.

Kim, Young Jin↗

Broadband Ultra-Sensitive Adiabatic Magnetometer

We introduce a new ultra-sensitive adiabatic magnetometer that has a broad bandwidth and can operate in the presence of magnetic fields and gradients. It follows conceptually typical implementations of atomic magnetometers based on alkali-metal vapor cells and lasers for optical pumping and optical Faraday effect detection, while its unique feature is a measurement of an oscillating magnetic field along the probe beam direction at frequencies lower than the resonant frequency, proportional to a static magnetic field along the pump beam direction. The bandwidth of the adiabatic magnetometer scales as the strength of the field along the pump beam. From our theoretical studies it is expected that the adiabatic magnetometer can reach 1 fT sensitivity with a bandwidth of 10 kHz, which any type of atomic magnetometers cannot achieve. Among anticipated various applications of this adiabatic magnetometer are biomagnetic sensing, nuclear magnetic resonance detection, and alkali-metal density measurements. In conclusion, we experimentally conducted alkali-metal density measurements, as an example of applications.

adiabatic magnetometer↗

Alignment of a vector magnetometer to an optical prism

A method for alignment of a vector magnetometer to a rigidly attached prism is presented. This enables optical comparison of the magnetometer axes to physical surfaces in the apparatus, and thus an absolute determination of the magnetic field direction in space. This is in contrast with more common techniques, which focus on precise determination of the relative angles between magnetometer axes, and so are more suited to measuring differences in the direction of magnetic fields. Here we demonstrate precision better than 500 μrad on a fluxgate magnetometer, which also gives the coil orthogonality errors to a similar precision. As a result, the relative sensitivity of the three axes is also determined, with a precision of about 5 ×10 –4 .

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Calibration and Localization of Optically Pumped Magnetometers Using Electromagnetic Coils

In this paper, we propose a method to estimate the position, orientation, and gain of a magnetic field sensor using a set of (large) electromagnetic coils. We apply the method for calibrating an array of optically pumped magnetometers (OPMs) for magnetoencephalography (MEG). We first measure the magnetic fields of the coils at multiple known positions using a well-calibrated triaxial magnetometer, and model these discreetly sampled fields using vector spherical harmonics (VSH) functions. We then localize and calibrate an OPM by minimizing the sum of squared errors between the model signals and the OPM responses to the coil fields. We show that by using homogeneous and first-order gradient fields, the OPM sensor parameters (gain, position, and orientation) can be obtained from a set of linear equations with pseudo-inverses of two matrices. The currents that should be applied to the coils for approximating these low-order field components can be determined based on the VSH models. Computationally simple initial estimates of the OPM sensor parameters follow. As a first test of the method, we placed a fluxgate magnetometer at multiple positions and estimated the RMS position, orientation, and gain errors of the method to be 1.0 mm, 0.2°, and 0.8%, respectively. Lastly, we calibrated a 48-channel OPM array. The accuracy of the OPM calibration was tested by using the OPM array to localize magnetic dipoles in a phantom, which resulted in an average dipole position error of 3.3 mm. The results demonstrate the feasibility of using electromagnetic coils to calibrate and localize OPMs for MEG.

47 OTHER INSTRUMENTATION↗

Diamond magnetometer enhanced by ferrite flux concentrators

Magnetometers based on nitrogen-vacancy (NV) centers in diamond are promising room-temperature, solid-state sensors. However, their reported sensitivity to magnetic fields at low frequencies (≲1 kHz) is presently ≳10 pTs 1/2 , precluding potential applications in medical imaging, geoscience, and navigation. Here we show that high-permeability magnetic flux concentrators, which collect magnetic flux from a larger area and concentrate it into the diamond sensor, can be used to improve the sensitivity of diamond magnetometers. By inserting an NV-doped diamond membrane between two ferrite cones in a bowtie configuration, we realize a ~ 250-fold increase of the magnetic field amplitude within the diamond. We demonstrate a sensitivity of ~ 0.9pTs 1/2 to magnetic fields in the frequency range between 10 and 1000 Hz. This is accomplished using a dual-resonance modulation technique to suppress the effect of thermal shifts of the NV spin levels. The magnetometer uses 200 mW of laser power and 20 mW of microwave power. This work introduces a new degree of freedom for the design of diamond sensors by using structured magnetic materials to manipulate magnetic fields.

47 OTHER INSTRUMENTATION↗

A high-sensitivity tunable two-beam fiber-coupled high-density magnetometer with laser heating

Atomic magnetometers (AM) are finding many applications in biomagnetism, national security, industry, and science. Fiber-coupled (FC) designs promise to make them compact and flexible for operation. Most FC designs are based on a single-beam configuration or electrical heating. Here, we demonstrate a two-beam FC AM with laser heating that has 5 fT/Hz 1/2 sensitivity at low frequency (50 Hz), which is higher than that of other fiber-coupled magnetometers and can be improved to the sub-femtotesla level. Here, this magnetometer is widely tunable from DC to very high frequencies (as high as 100 MHz; the only issue might be the application of a suitable uniform and stable bias field) with a sensitivity under 10 fT/Hz 1/2 and can be used for magneto-encephalography (MEG), magneto-cardiography (MCG), underground communication, ultra-low MRI/NMR, NQR detection, and other applications.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Polymer encapsulated microcavity optomechanical magnetometer

We demonstrate a magnetometer using polymer encapsulated whispering-gallery-mode microcavity actuated by a micro-magnet. The magnetic field induces force on the micro-magnet causing deformation in the polymer around the microcavity. Subsequently the microcavity detects the change in the refractive index of the polymer resulted from the deformation. This magnetometer works in the frequency range of hertz-to-kilohertz range and achieves a sensitivity of 880 pT/Hz 1/2 at 200 Hz in a micro-scale sensor volume. Polymer encapsulation of the magnetometer and fiber optical connection ensures environmental robustness and practicality of the sensor.

47 OTHER INSTRUMENTATION↗

High-sensitivity operation of single-beam optically pumped magnetometer in a kHz frequency range

Here, optically pumped magnetometers (OPM) can be used in various applications, from magnetoencephalography to magnetic resonance imaging and nuclear quadrupole resonance (NQR). OPMs provide high sensitivity and have the significant advantage of non-cryogenic operation. To date, many magnetometers have been demonstrated with sensitivity close to 1 fT, but most devices are not commercialized. Most recently, QuSpin developed a model of OPM that is low cost, high sensitivity, and convenient for users, which operates in a single-beam configuration. Here we developed a theory of single-beam (or parallel two-beam) magnetometers and showed that it is possible to achieve good sensitivity beyond their usual frequency range by tuning the magnetic field. Experimentally we have tested and optimized a QuSpin OPM for operation in the frequency range from DC to 1.7 kHz, and found that the performance was only slightly inferior despite the expected decrease due to deviation from the spin-exchange relaxation-free regime.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Search for exotic spin-dependent interactions with a spin-exchange relaxation-free magnetometer

We propose a novel experimental approach to explore exotic spin-dependent interactions using a spin-exchange relaxation-free (SERF) magnetometer, the most sensitive noncryogenic magnetic-field sensor. This approach studies the interactions between optically polarized electron spins located inside a vapor cell of the SERF magnetometer and unpolarized or polarized particles of external solid-state objects. The coupling of spin-dependent interactions to the polarized electron spins of the magnetometer induces the tilt of the electron spins, which can be detected with high sensitivity by a probe laser beam similarly as an external magnetic field. Lastly, we estimate that by moving unpolarized or polarized objects next to the SERF Rb vapor cell, the experimental limit to the spin-dependent interactions can be significantly improved over existing experiments, and new limits on the coupling strengths can be set in the interaction range below 10 –2 m.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Nuclear quadrupole resonance spectroscopy with a femtotesla diamond magnetometer

Radio frequency (RF) magnetometers based on nitrogen vacancy centers in diamond are predicted to offer femtotesla sensitivity, but previous experiments were limited to the picotesla level. We demonstrate a femtotesla RF magnetometer using a diamond membrane inserted between ferrite flux concentrators. The device provides ~300-fold amplitude enhancement for RF magnetic fields from 70 kHz to 3.6 MHz, and the sensitivity reaches ~70 fT√s at 0.35 MHz. The sensor detected the 3.6-MHz nuclear quadrupole resonance (NQR) of room-temperature sodium nitrite powder. The sensor’s recovery time after an RF pulse is ~35 μs, limited by the excitation coil’s ring-down time. The sodium-nitrite NQR frequency shifts with temperature as -1.00±0.02 kHz/K, the magnetization dephasing time is T 2 *=887±51 μs, and multipulse sequences extend the signal lifetime to 332±23 ms, all consistent with coil-based studies. Our results expand the sensitivity frontier of diamond magnetometers to the femtotesla range, with potential applications in security, medical imaging, and materials science.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Search for an axion-induced oscillating electric dipole moment for electrons using atomic magnetometers

We propose an experimental search for an axion-induced oscillating electric dipole moment (OEDM) for electrons using state-of-the-art alkali vapor-cell atomic magnetometers. The axion is a hypothesized new fundamental particle which can resolve the strong charge-parity problem and be a prominent dark matter candidate. This experiment utilizes an atomic magnetometer as both a source of optically polarized electron spins and a magnetic-field sensor. The interaction of the axion field, oscillating at a frequency equal to the axion mass, with an electron spin induces a sizable OEDM of the electron at the same frequency as the axion field. When the alkali vapor is subjected to an electric field and a magnetic field, the electron OEDM interacts with the electric field, resulting in an electron spin precession at the spin’s Larmor frequency in the magnetic field. The resulting precession signal can be sensitively detected with a probe laser beam of the atomic magnetometer. We estimate that the experiment is sensitive to the axion-photon interaction in ultralight axion masses from 10 -15 to 10 -10 eV. It is able to improve the current experimental limit up to 5 orders of magnitude, exploring new axion parameter spaces.

74 ATOMIC AND MOLECULAR PHYSICS↗

Influence of Viscosity on Dynamic Magnetization of Thermally Blocked Iron Oxide Nanoparticles Characterized by a Sensitive AC Magnetometer

In this work, we show that the viscosity of carrier liquid affects the dynamic magnetization of thermally blocked multi-core iron oxide nanoparticles. The core size of the nanoparticles was determined from the magnetization curve measured by a specially developed high-T{sub c} SQUID magnetometer and calculated to be 11.7 nm. Using an AC magnetometer developed based on induction coils, the dynamic magnetization of the multi-core iron oxide nanoparticle solution was measured from 3 Hz to 10.48 kHz. Later, we reconstructed of the hydrodynamic size distribution of the particles by assuming a log-normal distribution of particle size in an AC susceptibility model by Shliomis and Stepanov, which accounts for anisotropic directions of the easy axes of magnetic nanoparticles with respect to the excitation field direction. The reconstructed hydrodynamic sizes showed an average diameter of 130 nm and agreed with the size determined by dynamic light scattering method. In the case of increasing viscosity of the carrier liquids from 0.89 to 8.11 mPa s, the dynamic magnetization peaks of the imaginary component have shifted to a lower frequency region. We showed that the harmonics ratio and phase delay upon the magnetic field excitation at 30 Hz could also be used to determine the viscosity of carrier liquid independently.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

A spin-wave magnetometer with a positive feedback

In this work, we demonstrate experimentally the operation of a spin-wave magnetometer integrated into a circuit with a positive feedback. The circuit consists of the passive magnetic and active electric parts. The magnetic part includes a sensing element, which is a magnetic cross junction made of Y 3 Fe 2 (FeO 4 ) 3 . The electric part includes a non-linear amplifier and a phase shifter. The electric and magnetic parts are connected via micrometer size antennae. Spin waves are excited by two of these antennae while the output inductive voltage produced by the interfering spin waves is detected by the third antenna. Spin waves propagating in the orthogonal arms of the cross can accumulate significantly different phase shifts, depending on the direction and the strength of the external magnetic field. The output inductive voltage reaches its maximum in the case of constructive spin wave interference. The positive feedback provides further signal amplification. It appears possible to enhance the response function, compared to the passive circuits without a feedback, by a factor of ×100 without an increase in the noise level. The experimental data show a prominent response to the external magnetic field variation, exceeding 5 x 10 3 V/T. The intrinsic noise spectral density of the device can be as low as 10 -16 V 2 /Hz. The estimated sensitivity of the prototype device is 2 x 10 -12 T/√Hz at room temperature. We argue that spin-wave magnetometers can potentially be as sensitive as SQUIDs while operating at room temperature.

36 MATERIALS SCIENCE↗

Peripheral Nerve Magnetoneurography With Optically Pumped Magnetometers

Electrodiagnosis is routinely integrated into clinical neurophysiology practice for peripheral nerve disease diagnoses, such as neuropathy, demyelinating disorders, nerve entrapment/impingement, plexopathy, or radiculopathy. Measured with conventional surface electrodes, the propagation of peripheral nerve action potentials along a nerve is the result of ionic current flow which, according to Ampere’s Law, generates a small magnetic field that is also detected as an “action current” by magnetometers, such as superconducting quantum interference device (SQUID) Magnetoencephalography (MEG) systems. Optically pumped magnetometers (OPMs) are an emerging class of quantum magnetic sensors with a demonstrated sensitivity at the 1 fT/√Hz level, capable of cortical action current detection. But OPMs were ostensibly constrained to low bandwidth therefore precluding their use in peripheral nerve electrodiagnosis. With careful OPM bandwidth characterization, we hypothesized OPMs may also detect compound action current signatures consistent with both Sensory Nerve Action Potential (SNAP) and the Hoffmann Reflex (H-Reflex). In as much, our work confirms OPMs enabled with expanded bandwidth can detect the magnetic signature of both the SNAP and H-Reflex. Taken together, OPMs now show potential as an emerging electrodiagnostic tool.

60 APPLIED LIFE SCIENCES↗

The fixed probe storage ring magnetometer for the Muon g-2 experiment at Fermi National Accelerator Laboratory

The goal of the FNAL E989 experiment is to measure the muon magnetic anomaly to unprecedented accuracy and precision at the Fermi National Accelerator Laboratory. To meet this goal, the time and space averaged magnetic environment in the muon storage volume must be known to better than 70 ppb. A new pulsed proton nuclear magnetic resonance (NMR) magnetometer was designed and built at the University of Washington, Seattle to track the temporal stability of the 1.45 T magnetic field in the muon storage ring at this precision. It consists of an array of 378 petroleum jelly based NMR probes that are embedded in the walls of muon storage ring vacuum chambers and custom electronics built with readily available modular radio frequency (RF) components. We give NMR probe construction details and describe the functions of the custom electronic subsystems. The excellent performance metrics of the magnetometer are discussed, where after 8 years of operation the median single shot resolution of the array of probes remains at 650 ppb.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗