Search NASA⌕ Search

SEARCH · Search NASA

Results for “MAGNETRONS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Cylindrical Magnetron Development for Nb3sn Deposition via Magnetron Sputtering

Due to its better superconducting properties (critical temperature Tc~ 18.3 K, superheating field Hsh~ 400 mT), Nb₃Sn is considered as a potential alternative to niobium (Tc~ 9.25 K, Hsh~ 200 mT) for superconducting radiofrequency (SRF) cavities for particle acceleration. Magnetron sputtering is an effective method to produce superconducting Nb₃Sn films. We deposited superconducting Nb₃Sn films on samples with magnetron sputtering using co-sputtering, sequential sputtering, and sputtering from a stoichiometric target. Nb₃Sn films produced by magnetron sputtering in our previous experiments have achieved DC superconducting critical temperature up to 17.93 K and RF superconducting transition at 17.2 K. A magnetron sputtering system with two identical cylindrical cathodes that can be used to sputter Nb₃Sn films on cavities has been designed and is under development now. We report on the design and the current progress on the development of the system.

43 PARTICLE ACCELERATORS↗

Utilization of the CW magnetrons as coherent RF sources for superconducting RF accelerators

CW magnetrons designed and optimized for industrial heaters, driven by an injection-locking signal, were suggested to power Superconducting RF (SRF) cavities. However, the CW magnetrons, which are regenerative generators, are intended to operate in self-excitation mode, so, for reliable starting they use a large regenerative gain, causing a large regenerative instability in operation. Thus, power supply ripple, even shot noise, etc., lead to multiple sidebands forming a quasi-continuous noise spectrum at the carrier frequency. Therefore, in the traditionally used mode of operation and control, such magnetrons are inapplicable for powering high Q-factor SRF cavities. A new approach to operation and control of CW magnetrons considering non-stationary processes during start-up and operation makes it possible to find a mode of almost coherent RF generation of tubes with a significant reduction in regenerative instability and noise and increased efficiency. In our work is presented substantiation for the newly developed mode with an analysis of the new approach based on experimental results. •In this article, for the first time, non-stationary, regenerative processes are considered during the start-up and operation of CW magnetrons for powering high-Q superconducting RF cavities.•An analytical study, confirmed by experiments, showed that the traditionally used modes of starting and operating CW magnetrons are not suitable for powering high-Q superconducting RF cavities.•In fact, to make CW magnetrons suitable for such cavities, the physics of starting and operating CW magnetrons must be changed. This has been demonstrated in our work.•In developing the Stimulated Coherent Generation Mode [NIM A 980 (2020) 164366], we have shown the suitability of this mode for starting and operating CW magnetrons for high-Q superconducting RF cavities.•Analytical analysis, verified experimentally, substantiates in our article the suitability of the “Mode of stimulated coherent generation” of CW magnetrons for powering high-Q superconducting cavities in pulsed and continuous modes.

43 PARTICLE ACCELERATORS↗

Commissioning of a two-target DC cylindrical magnetron sputter coater for depositing Nb 3 Sn film on Nb superconducting radiofrequency cavities

A DC cylindrical magnetron sputter coater was commissioned and used to coat Nb 2.6 GHz superconducting radiofrequency (SRF) cavity with Nb 3 Sn. The sputter coater has two identical cylindrical magnetrons that can move, with a controlled speed, along the axis of the SRF cavity to coat the inside surface of the cavity. The design of the sputter coater is discussed, along with its performance. Initially, a sample holder that allows coating on flat substrates at positions similar to the equator and beam tubes of a 2.6 GHz SRF cavity was used to test conditions for fabricating Nb 3 Sn layers. Multilayers of Nb and Sn were sequentially sputtered on flat Nb and sapphire substrates mounted on the equivalent positions of the cavity's beam tubes and the equator using the two identical cylindrical magnetrons. Then, the Nb/Sn multilayers were annealed at 950 °C for 3 h. Here, the ~1.2 μm thick Nb 3 Sn film did not show any other Nb–Sn compounds and had a superconducting transition temperature of 17.61–17.76 K. The 2.6 GHz SRF cavity was coated using similar conditions as flat samples. Cryogenic RF testing of the Nb 3 Sn-coated cavity demonstrated a quality factor of 3.2 × 10 8 at an accelerating gradient of 5 MV/m at 4.4 K.

43 PARTICLE ACCELERATORS↗

High-Power Impulse Magnetron Sputter Deposition of Boron Carbide with Full-Face Erosion Magnetron and Mixed Ar-Ne Plasma

Boron carbide (B 4 C) is an attractive inertial confinement fusion ablator material. The fabrication of B4C ablators by magnetron sputtering requires process optimization. To increase process flexibility, here we explore high-power impulse magnetron sputter (HiPIMS) deposition of B 4 C in pure Ar and mixed Ar-Ne plasmas. Here, the results show that higher plasma discharge currents can be reached with a mixed Ar-Ne plasma in the entire working pressure range studied (5 𝑡𝑜 50 mTorr). At 45 mTorr with 10% of Ne in the Ar-Ne mix, high peak target current densities of ~1 A cm −2 were demonstrated. Films deposited with such a mixed Ar-Ne plasma with a full-face erosion magnetron source on substrates biased at −25 V exhibited higher density and improved mechanical properties, albeit with higher compressive residual stresses compared to the case of HiPIMS deposition in a pure Ar plasma. This work demonstrates additional process flexibility of the HiPIMS discharge mode for the deposition of B 4 C coatings.

Ablator capsule↗

A 100-kW 1300-MHz Magnetron With Amplitude and Phase Control for Accelerators

Calabazas Creek Research, Inc. (CCR), in collaboration with Fermilab and Communications and Power Industries, LLC (CPI), developed a 100-kW peak, 10-kW average, 1300-MHz, magnetron-based, RF system with amplitude and phase control for driving accelerators. Phase locking was achieved using an approach originated at Fermilab that uses phase modulation of the locking signal to control the amplitude and phase into a superconducting cavity on a fast time scale. Experimental results, including demonstration of phase locking and amplitude control, are reported.

43 PARTICLE ACCELERATORS↗

Experimental evaluation of direct current magnetron sputtered and high-power impulse magnetron sputtered Cr coatings on SiC for light water reactor applications

Two types of physical vapor deposition Cr coatings were deposited on chemical vapor deposited SiC coupons using conventional direct current magnetron sputtering (DCMS) and high-power impulse magnetron sputtering (HiPIMS) to mitigate the corrosion of SiC, an advanced fuel and structural material in light water nuclear reactor cores. Coating microstructure was characterized using scanning electron microscopy and scanning transmission election microscopy. X-ray diffraction analysis was conducted for phase identification and qualitative analysis of residual stresses. The mechanical integrity of the coatings was evaluated using scratch testing, micro-indentation, and nano-indentation tests. Additionally, the microstructure of the DCMS coating consisted of fine columnar grains with nanoscale intercolumnar channels, while the HiPIMS microstructure was denser and free of any columnar defects. The DCMS coating showed a small tensile residual stress, while the HiPIMS coating was under compressive stress. Both types of coatings showed good mechanical integrity in terms of ductility and adhesion to the substrate. Corrosion performance of the coatings was assessed with a 30-day high temperature water autoclave test. Both types of coatings formed a protective Cr 2 O 3 surface layer 20-30 nm thick during the autoclave test. In the DCMS coating, the columnar defects provided permeation pathways for water penetration resulting in oxide formation in the intercolumnar regions in the interior of the coating. Overall, both types of Cr coatings offer promise for the mitigation of hydrothermal corrosion of SiC in light water reactor operating environments.

36 MATERIALS SCIENCE↗

On the Life Expectancy Ot High-power CW Magnetrons for Superconducting Accelrators

Modern CW or pulse Superconducting RF (SRF) accelerators require efficient RF sources controllable in phase and power with a reduced cost. Therefore, utilization of the high-power CW magnetrons as RF sources in SRF accelerator projects was proposed in a number of works, e.g., [1, 2]. But typically, the CW magnetrons are designed as RF sources for industrial heating, and the lifetime of the tubes is not the first priority as it is required for high-energy accelerators. The high-power industrial CW magnetrons use the cathodes made of pure tungsten. The emission properties of the tungsten cathodes are not deteriorated much by electron and ion bombardments, but the latter causes sputtering of the cathode in the magnetron crossed fields. The sputtered cathode material covers the magnetron interior. This leads to sparks and discharges that limit the life of the magnetrons. We considered an analysis of magnetron failure modes vs. output power [3]. We developed a model of ionization of the residual gas in the magnetrons interaction space and simulated the spattering of the cathode in 100 kW CW magnetrons to estimate the life expectancy. Basing on results we proposed ways to increase the CW magnetrons longevity for SRF accelerators.

43 PARTICLE ACCELERATORS↗

On the Life Expectance of High-power CW Magnetrons for SRF Accelerators

Modern CW or pulse Superconducting RF (SRF) accelerators require efficient RF sources controllable in phase and power with a reduced cost. Therefore, utilization of the high-power CW magnetrons as RF sources in SRF accelerator projects was proposed in a number of works, e.g., [1, 2]. But typically, the CW magnetrons are designed as RF sources for industrial heating, and the lifetime of the tubes is not the first priority as it is required for high-energy accelerators. The high-power industrial CW magnetrons use the cathodes made of pure tungsten. The emission properties of the tungsten cathodes are not deteriorated much by electron and ion bombardments, but the latter causes sputtering of the cathode in the magnetron crossed fields. The sputtered cathode material covers the magnetron interior. This leads to sparks and discharges that limit the life of the magnetrons. We considered an analysis of magnetron failure modes vs. output power [3]. We developed a model of ionization of the residual gas in the magnetrons interaction space and simulated the spattering of the cathode in 100 kW CW magnetrons to estimate the life expectancy. Basing on results we proposed ways to increase the CW magnetrons longevity for SRF accelerators.

43 PARTICLE ACCELERATORS↗

Tutorial: Reactive high power impulse magnetron sputtering (R-HiPIMS)

High Power Impulse Magnetron Sputtering (HiPIMS) is a coating technology that combines magnetron sputtering with pulsed power concepts. Furthermore, by applying power in pulses of high amplitude and a relatively low duty cycle, large fractions of sputtered atoms and near-target gases are ionized. In contrast to conventional magnetron sputtering, HiPIMS is characterized by self-sputtering or repeated gas recycling for high and low sputter yield materials, respectively, and both for most intermediate materials. The dense plasma in front of the target has the dual function of sustaining the discharge and providing plasma-assistance to film growth, affecting the microstructure of growing films. Many technologically interesting thin films are compound films, which are composed of one or more metals and a reactive gas, most often oxygen or nitrogen. When reactive gas is added, non-trivial consequences arise for the system because the target may become “poisoned,” i.e., a compound layer forms on the target surface affecting the sputtering yield and the yield of secondary electron emission and thereby all other parameters. It is emphasized that the target state depends not only on the reactive gas' partial pressure (balanced via gas flow and pumping) but also on the ion flux to the target, which can be controlled by pulse parameters. This is a critical technological opportunity for reactive HiPIMS (R-HiPIMS). The scope of this tutorial is focused on plasma processes and mechanisms of operation and only briefly touches upon film properties. It introduces R-HiPIMS in a systematic, step-by-step approach by covering sputtering, magnetron sputtering, reactive magnetron sputtering, pulsed reactive magnetron sputtering, HiPIMS, and finally R-HiPIMS. The tutorial is concluded by considering variations of R-HiPIMS known as modulated pulsed power magnetron sputtering and deep-oscillation magnetron sputtering and combinations of R-HiPIMS with superimposed dc magnetron sputtering.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

On forced RF generation of CW magnetrons for SRF accelerators

CW magnetrons, initially developed for industrial RF heaters, were suggested to power RF cavities of superconducting accelerators due to their higher efficiency and lower cost of RF power per Watt than used traditionally klystrons, IOTs or solid-state amplifiers. RF amplifiers driven by a master oscillator serve as coherent RF sources. CW magnetrons are regenerative RF generators with a huge regenerative gain to start up reliably with self-excitation even if the tube is powered by a DC power supply. This causes regenerative instability with a large noise when a magnetron operates with the anode voltage above the threshold of self-excitation. Traditionally for stabilization of magnetrons is used injection locking by a signal PLock ≤ -20 dB or less then of the magnetron power PMag. Then the magnetron generates the injection locked oscillations and generates noise. This may preclude use of standard CW magnetrons in some SRF accelerators. We developed briefly described below a mode for forced coherent RF generation of CW magnetrons when the magnetron startup is provided by the injected forcing signal and the regenerative noise is suppressed. The mode is most suitable for powering high Q-factor SRF cavities.

Kazakevich, G.↗

On operation and control of CW magnetrons for superconducting accelerators

CW magnetrons, developed for industrial RF heaters, were suggested to feed RF cavities of superconducting accelerators due to higher efficiency and lower cost of RF power than provide traditionally used klystrons, IOTs or solid-state amplifiers. RF amplifiers driven by a master oscillator serve as coherent RF sources. CW magnetrons are regenerative RF auto generators with a huge regenerative gain. This causes regenerative instability with a notable noise when a magnetron operates as an auto generator i.e., with the anode voltage above the threshold of self-excitation. Traditionally, an injection locking by a small signal is used for phase stabilization of magnetrons. In this case CW magnetrons with the injection-locked (coherent) oscillations generate a notable level of noise. This may preclude use of CW magnetrons in this mode in the Superconducting RF (SRF) accelerators. This paper reviews PIC modeling and previously obtained experimental results for the operation and control of CW magnetrons, which led to the development of techniques most suitable for various SRF accelerators using forced RF oscillation of magnetrons, when the magnetron is launched by an injected forcing signal, and regenerative noise is suppressed.

Kazakevich, G. [MUONS Inc., Batavia] (ORCID:000000↗

Forced RF generation of CW magnetrons for superconducting accelerators

CW magnetrons, designed and optimized for industrial RF heaters, were suggested to power Superconducting RF cavities due to their higher efficiency and lower cost than traditional klystrons, IOT’s, or solid-state amplifiers. RF amplifiers driven by a master-oscillator serve as coherent RF sources. CW magnetrons are regenerative RF generators with a huge regenerative gain. Very large regenerative gain causes instability with intense noise when a magnetron operates with the anode voltage higher than the threshold of self-excitation. Traditionally for stabilization of magnetrons is used injection-locking by a quite small signal. In this case the CW magnetrons do not provide correlation of the magnetron startup with the injection-locking signal. Thus, the magnetron except the injection locked oscillations may generate large noise. This may increase emittance of the beam in SRF accelerators. Recently we have developed mode for forced RF generation of CW magnetrons when the magnetron startup is provided by the injected forcing signal and the regenerative noise is suppressed. The mode is most suitable for SRF accelerators. The mode is briefly described below.

43 PARTICLE ACCELERATORS↗

An efficient magnetron transmitter for superconducting accelerators

A concept of a highly-efficient high-power magnetron transmitter allowing wide-band phase and the mid-frequency power control at the frequency of the locking signal is proposed. The proposal is aimed for powering Superconducting RF (SRF) cavities of intensity-frontier accelerators. The transmitter is intended to operate with phase and amplitude control feedback loops allowing suppression of microphonics and beam loading in the SRF cavities. The concept utilizes injectionlocked magnetrons controlled in phase by the locking signal supplied by a feedback system. The injection-locking signal pre-excites the magnetron and allows its operation below the critical voltage. This realizes control of the magnetron power in a wide range by control of the magnetron current. Pre-excitation of the magnetron by the locking signal provides an output power range up to 10 dB. Experimental studies were carried out with 2.45 GHz, 1 kW, CW magnetrons. They demonstrated stable operation of the magnetrons and power control at a low noise level. In conclusion, an analysis of the kinetics of the drifting charge in the drift approximation substantiates the concept and the experimental results.

43 PARTICLE ACCELERATORS↗

On forced RF generation of CW magnetrons for accelerators

CW magnetrons, initially developed for industrial RF heaters, were suggested to power RF cavities of superconducting accelerators due to their higher efficiency and lower cost than traditionally used klystrons, IOTs or solid-state amplifiers. RF amplifiers driven by a master oscillator serve as coherent RF sources. CW magnetrons are regenerative RF generators with a huge regenerative gain. This causes regenerative instability with a quite large noise when a magnetron operates with the anode voltage above the threshold of self-excitation. Traditionally, an injection locking by a small signal is used for stabilization of magnetrons. In this case CW magnetrons with the injection-locked oscillations generate a high level of noise. This may preclude use of standard CW magnetrons in this operating mode in the Superconducting RF (SRF) accelerators. In this article we described a method developed for forced RF generation of CW magnetrons when the magnetron startup is provided by the injected forcing signal and the regenerative noise is suppressed. The method is most suitable for powering high Q-factor cavities.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

On Forced RF Generation of CW Magnetrons for SRF Accelerators

CW magnetrons, initially developed for industrial RF heaters, were suggested to power RF cavities of superconducting accelerators due to their higher efficiency and lower cost than traditionally used klystrons, IOTs or solid-state amplifiers. RF amplifiers driven by a master oscillator serve as coherent RF sources. CW magnetrons are regenerative RF generators with a huge regenerative gain. This causes regenerative instability with a large noise when a magnetron operates with the anode voltage above the threshold of self-excitation. Traditionally for stabilization of magnetrons is used injection locking by a quite small signal. Then the magnetron except the injection locked oscillations may generate noise. This may preclude use of standard CW magnetrons in some SRF accelerators. Recently we developed briefly described below a mode for forced RF generation of CW magnetrons when the magnetron startup is provided by the injected forcing signal and the regenerative noise is suppressed. The mode is most suitable for powering high Q-factor SRF cavities.

43 PARTICLE ACCELERATORS↗

Muons Inc Master CRADA with Annex A for Magnetron Development

Modern CW or pulsed superconducting accelerators of megawatts beams require efficient RF sources controllable in phase and power. It is desirable to have an individual RF power source with power up to hundreds of kW for each Superconductive RF (SRF) cavity. For pulsed accelerators the pulse duration in millisecond range is required. The efficiency of the traditional RF sources (klystrons, IOTs, solid-state amplifiers) in comparison to magnetrons is lower and the cost of unit of RF power is significantly higher. Typically, the cost of RF sources and their operation is a significant part of the total project cost and operation. The magnetron-based RF sources with a cost of power unit of 1-3 dollars per Watt would significantly reduce the capital and operation costs in comparison with the traditional RF sources. This arouses interest in magnetron RF sources for use in modern accelerators. A recently developed kinetic model describing the principle of magnetron operation and subsequent experiments resulted in an innovative technique producing the "stimulated" generation of magnetrons powered below the self-excitation threshold voltage. The magnetron operation in this regime is stable, low noise, controllable in phase and power, and provides higher efficiency than other types of RF power sources. It allows operation in CW and pulse modes (at large duty factor). For pulsed operation this technique does not require pulse modulators to form RF pulses. It also looks as a promising opportunity to extend magnetron life time.

43 PARTICLE ACCELERATORS↗