Search NASA⌕ Search

SEARCH · Search NASA

Results for “MASER OUTPUT”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

A receiver design for the superconducting cavity-maser oscillator

A new frequency standard was demonstrated with the aid of a double phase locked loop (PLL) receiver. A superconducting cavity maser oscillator (SCMO) and a hydrogen maser are combined to show the medium term performance of the hydrogen maser together with improved short term performance made possible by the SCMO. The receiver, which generates a 100 MHz signal with reduced noise, is phase locked to (and may be used in place of) the 100 MHz hydrogen maser output. The maser signal, 2.69xxx-GHz SCMO output, and a 100 MHz quartz crystal oscillator are optimally combined by the receiver. A measured two source fractional frequency stability of 2 x 10(exp -14) was obtained for a measuring time of r = 1 sec, and 1 x 10(exp -15) at r = 1,000 sec. The 1 sec value is approx. 10 times lower than that for hydrogen masers, while the 1,000 sec value is identical to hydrogen maser performance. The design is based on phase noise models for the hydrogen maser, the SCMO, and quartz crystal oscillators for offset frequencies down to 1 x 10(exp -6) Hz.

Wang, R. T.↗

Hydrogen Masers as Time and Frequency Standards

Track each other with 100 times more precision than cesium standards. Geographically separated hydrogen masers tracked each other for more than year to within few parts in 10 to the 15th power. Frequency offset of hydrogen-maser output from hyperfine line frequency is function of ambient magnetic field, cavity mistuning, thermal motion of atoms in cavity and collisions of atoms with walls of the cavity. If maser remains at one location some of small offsets in frequency will remain constant throughout life of maser.

Ward, S. C.↗

Fast autotuning of a hydrogen maser by cavity Q modulation

A new fast autotuner for the hydrogen maser was implemented. By modulating the cavity, a phase shift in the maser output signal is induced which is proportional to the cavity tuning error. The phase shift is detected and fed back to a varactor tuner to stabilize the cavity against long-term drifts. Also, a PIN-diode cavity modulator which gives no incidental frequency shift over a very wide range of operation was developed. Modulated at over 200 Hz, it allows variations in maser cavity frequency to be compensated with a loop gain greater than 1000. Compensation of incidental amplitude modulation of the output was demonstrated.

Dick, G. J.↗

A method of eliminating hydrogen maser wall shift

Maser output frequency shift was prevented by storage bulb kept at temperature at which wall shift is zero and effects of bulb size, shape, and surface texture are eliminated. Servo system is shown, along with bidirectional counter.

Levine, M. W.↗

Hydrogen maser frequency standards for the Deep Space Network

A field operable maser has been developed for use in the Deep Space Network. Maser design was based on two experimental hydrogen maser frequency standards in operation since 1970 at DSN stations. Many design changes have been incorporated into the maser design, both in physics and electronics systems. Short and long term frequency, RF isolation of maser output lines and the lifetime of active physics components have been improved. Automatic fault detection and location, and performance and reliability of the receiver-synthesizer system have also been altered.

Dachel, P. R.↗

Saturation and beaming in astrophysical masers. II - The fully saturated limit

Radiative transfer in fully saturated maser clouds has been investigated using the 'four-stream' model equations of Alcock and Ross (1985). It is shown that a modest elongation of the maser cloud produces a substantial asymmetry in the maser output. The ratio of output fluxes in different directions is a strong function of the ratio of the corresponding chord lengths across the cloud. Arguments are presented that the asymmetries reported here for the 'four-stream' models closely mimic the asymmetries that should be expected in a real master cloud.

Alcock, C.↗

GPS Block 2R Time Standard Assembly (TSA) architecture

The underlying philosophy of the Global Positioning System (GPS) 2R Time Standard Assembly (TSA) architecture is to utilize two frequency sources, one fixed frequency reference source and one system frequency source, and to couple the system frequency source to the reference frequency source via a sample data loop. The system source is used to provide the basic clock frequency and timing for the space vehicle (SV) and it uses a voltage controlled crystal oscillator (VCXO) with high short term stability. The reference source is an atomic frequency standard (AFS) with high long term stability. The architecture can support any type of frequency standard. In the system design rubidium, cesium, and H2 masers outputting a canonical frequency were accommodated. The architecture is software intensive. All VCXO adjustments are digital and are calculated by a processor. They are applied to the VCXO via a digital to analog converter.

Baker, Anthony P.↗

Effect of thermal cycling on stress in metallic films on ceramic substrates

The hydrogen maser is the most stable frequency standard currently available for averaging intervals of hours to weeks. A major contributor to maser frequency variations is the maser's microwave resonant cavity: by means of the cavity pulling effect, a change in the cavity's resonance frequency produces a proportional change in the maser's output frequency. To minimize variations in the cavity's dimensions, and thus in its resonance frequency, maser cavities are often constructed of a low-expansivity glass-ceramic material coated on its surface with a conductive metallic film. It was previously shown that silver films like those used in SAO maser cavities develop tensile stress when cooled to room temperature after being fired onto the cavity, and that the stress in such films relaxes with time at a rate proportional to the level of stress. Stress relaxation in maser cavity coatings can alter the shape, and hence the resonance frequency, of the cavity, resulting in a slow variation in the maser's output frequency. The possibility was investigated of reversing the initial tensile stress by precooling the coated cavity material. It was hypothesized that cooling the material well below its normal working temperature and then warming it to its normal temperature would result in a lower tensile stress or even a compressive stress. Under such a condition stress relaxation, and thus any consequent frequency drifts, might be reduced or reversed.

Mattison, Edward M.↗

Short-term frequency stability of the Rb-87 maser.

Measurements of the short-term stability of the Rb-87 maser as a function of the maser power output and the receiver cutoff frequency are reported. The experimental data are compared to theoretical results obtained from an approximate theory. In this theory the transfer function of the maser for thermal noise is derived, and the spectral density of the phase fluctuations is calculated. An analytical expression for the 'Allan variance' is also given. A comparison of the stability of the Rb-87 maser with existing frequency standards shows its superiority for averaging times less than 1 sec.

Tetu, M.↗

Atomic hydrogen maser measurements with wall surfaces of carbon tetrafluoride

The principal objectives of the Smithsonian Astrophysical Observatory cold maser research programs are given. This work is aimed principally at understanding more about the interaction of hydrogen atoms with wall coatings of fluorinated ethylene propylene (Dupont Teflon FEP-120 co-polymer) and of carbon tetrafluoride (CE4). The principal measured quantity in these experiments is the wall shift of the maser's output frequency. The wall shift per atomic collision was calculated from the measured wall frequency shift. This assumes that the wall surface area is smooth on a molecular scale.

Vessot, R. F. C.↗

Saturation and beaming in astrophysical masers. III - Asymmetrically pumped masers

There is reason to believe that the physical conditions in many astrophysical masers are far from homogeneous. In particular, if the maser pump involves the absorption of infrared photons, the pump rate may vary rapidly (perhaps exponentially) across the cloud. The consequences of such variation of the pump rate for the maser radiation are calculated, and it is shown that there are substantial asymmetries in the output of the maser. A general result is that the maser radiation is preferentially emitted back toward the source of pump radiation. The implication of this result for the interpretation of the circumstellar 1612 MHz OH masers is briefly discussed.

Alcock, C.↗

Maser Oscillator With Dielectric Resonators

Two-resonator design yields low phase noise. Oscillator exhibits phase noise intermediate between phase noises of unstablized microwave oscillators and stabilized ruby-maser oscillators with superconducting cavities. Contains two total-internal-reflection dielectric resonators in normally-conductive copper cavity. Two-resonator maser design provides phase stability, isolation between pump and output channels, and variable maser coupling.

Dick, G. John↗

Light and buffer-gas frequency shifts in the Rb-85 maser frequency standard.

The effect of buffer gas and pumping light on the output frequency of the Rb-85 maser is discussed. In contrast to a primary standard, these frequency shifts can be used to advantage when it is necessary to operate the maser at a frequency which differs from the ground-state hyperfine frequency by a few kilohertz. Using appropriate mixtures of buffer gas and carefully shaped lamp spectral profiles, it is also possible to operate the maser exactly at the ground-state hyperfine frequency. It is pointed out that the short-term phase stability of the maser is not impaired by these shifts.

Stern, W. A.↗

Dielectric-loaded waveguide circulator for cryogenically cooled and cascaded maser waveguide structures

A dielectrically loaded four port waveguide circulator is used with a reflected wave maser connected to a second port between first and third ports to form one of a plurality of cascaded maser waveguide structures. The fourth port is connected to a waveguide loaded with microwave energy absorbing material. The third (output signal) port of one maser waveguide structure is connected by a waveguide loaded with dielectric material to the first (input) port of an adjacent maser waveguide structure, and the second port is connected to a reflected wave maser by a matching transformer which passes the signal to be amplified into and out of the reflected wavemaser and blocks pumping energy in the reflected wave maser from entering the circulator. A number of cascaded maser waveguide structures are thus housed in a relatively small volume of conductive material placed within a cryogenically cooled magnet assembly.

Clauss, R. C.↗