Search NASA⌕ Search

SEARCH · Search NASA

Results for “MASS FILTER”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Assessment of Low-Level Pu Isotope Ratio Measurements Using Multicollector Inductively Coupled Plasma Mass Spectrometry (MC-ICP-MS/MS) Equipped with a Pre-Mass Filter

We present an initial investigation into the performance of a multicollector inductively coupled plasmamass spectrometer equipped with a pre-mass filter (Neoma MC-ICP-MS/MS) for making plutonium (Pu) isotope ratio measurements on solutions containing low level (i.e., pg mL –1 ) Pu concentrations. This assessment was achieved by comparison of the 240 Pu/ 239 Pu, 241 Pu/ 239 Pu, and 242 Pu/ 239 Pu ratios attained over a one month period on the MC-ICP-MS/MS with the long-term (∼1 year) performance observed on the predecessor MC-ICP-MS (Neptune Plus) instrument each equipped with an equipped with an APEXΩ desolvating nebulizer for repeated measurements of certified reference materials from New Brunswick Program Office (NBL PO) CRM 136a and CRM 137. The MC-ICP-MS/MS performance of repeated measurement of CRM 136a (n = 20) resulted in mean values of 240 Pu/ 239 Pu = 0.1448 ± 0.0006, 241 Pu/ 239 Pu = 0.00371 ± 0.00006, and 242 Pu/ 239 Pu = 0.00682 ± 0.00006 (k = 2). The CRM 137 (n = 20), analyzed during the same analytical sessions, produced mean values for 240 Pu/ 239 Pu = 0.2414 ± 0.0006, 241 Pu/ 239 Pu = 0.00464 ± 0.00007, and 242 Pu/ 239 Pu = 0.0157 ± 0.0001 (k = 2). These results closely align with the certificate values for CRM 136a and CRM 137 and are within the k = 2 envelopes defined by the long-term performance of the traditional MC-ICP-MS approach (Neptune Plus). Examination of the performance of the various Pu isotope ratios as a function of total Pu content revealed accurate results (<3% relative difference, or RD) above ∼50 fg total Pu. The results presented here demonstrate the capability of the MC-ICP-MS/MS making accurate and precise low level Pu isotopic measurements. While the intent of this work was not to investigate the functionality of the collision cell, the pre-mass filter was employed. Future studies are warranted to investigate the entire capability of the MC-ICP-MS/MS collision cell and pre-cell mass filter optimization for performing low level Pu isotope measurements, even in mixed matrix samples.

CRM↗

Understanding the Quadrupole Mass Filter and Testing a High-Resolution QMS RGA for ITER

A common type of residual gas analyzer is the quadrupole mass spectrometer. One of the main components within this instrument is a mass filter known as the quadrupole. It is responsible for the selective throughput of the ionized gas particles - by ascending mass number - prior to ion impacts on the analyzer (or detector) surface from which the ion current signal is generated for processing. However, the quadrupole is not fully described in relation to the electric field characteristics and the function as an ion mass separator. This paper describes the basic origins of the electrical design, the intricate assembly criteria, and performance of the quadrupole within the spectrometer. A specialized quadrupole mass spectrometer is part of a configuration for a diagnostic gas analyzer system planned for ITER, a fusion research machine. It has a verified capability, essential as a diagnostic criterion for this reactor project, to successfully deconvolute the mass signals of Helium-4 and deuterium (reactor fuel exhaust gases, separated by only 0.026 atomic mass units), down to a relative three-percent concentration of the former gas. The associated preliminary testing, performed at the Oak Ridge National Laboratory, is also addressed. Finally, one of the key parameters used to express gas concentration, the relative sensitivity factor, will be explained, including an evaluation of dependency on other variables.

Marcus, Chris [ORNL] (ORCID:0000000190139636)↗

Collective Analysis of Alpha Particle Losses Due to Self-Absorption by Mass Loading on Radioactive Particulate Glass Fiber Filters

In this study, we derived a relationship between filter mass loading and the percent loss during analysis using the mass loading data collected from six previous studies of self-absorption. Components of mass loading include particulate dust, radioactive particulates, and filter material. In a research report published in 1984, Higby calculated a minimum burial depth for an alpha particle to be lost due to absorption (100% loss) of about 3.7 mg/cm 2 based on calculations for the range of 239-Pu alpha particles in glass fiber filters. From there, Higby concluded that a correction factor of 0.85 assumes approximately 15% losses in the count rate of both alpha and beta particles. In 2000, Luetzelschwab et al. recommended assuming a 40% loss at a loading of 3.3 mg/cm 2 and a 28% loss for a loading of 2.3 mg/cm 2 which included the frontal face mass of the filter. More recently, the 100% losses due to absorption were reported to be in the 10 mg/cm 2 range. Presented here is a trinomial relationship method of relating percent loss due to self-absorption to filter mass loading, based on data reported by Higby, Luetzelschwab et al., Huang et al., Barnett et al., Smith et al., and Hogue et al. Under normal operating conditions at the stacks monitored by Effluent Management, the mass loading of sample filters averages 0.09 ± 0.12 (2s) mg/cm 2 (excluding negative values and outliers) and ranges from 0 mg/cm 2 to 0.24 mg/cm 2 . Based on current mass loading results for Effluent Management stack sample filters, the forced-zero trinomial relationship method estimated self-absorption losses of less than 5%. Because American National Standards Institute/Health Physics Society N13.1-2011 guidelines indicate a correction factor should be used when the penetration of radioactive material into the collection media or self-absorption of radiation by the material collected would reduce the count rate by more than 5%, it is possible continued application of a correction factor to the Effluent Management stack samples is no longer necessary. Nevertheless, continuing to assign a correction factor at the 5% threshold (i.e., 0.95) would be a conservative approach.

36 MATERIALS SCIENCE↗

Tandem Mass-Selective Cryogenic Digital Ion Traps for Enhanced Cluster Formation

We present the implementation of tandem mass-selective cryogenic ion traps, designed to enhance the range of ion processing capabilities that can be performed prior to spectroscopic interrogation. We show that both the formation of ion clusters and mass filtering steps can be combined in a single cryogenic linear quadrupole ion trap driven by RF square waves. Mass filtering and mass isolation can be achieved by manipulation of the RF frequency and duty cycle. Very importantly, this scheme circumvents the need for high-amplitude RF voltages that can be incompatible with typical cryogenic ion processing conditions. In addition, proper adjustment of the stability boundaries during the clustering process allows for the preferential formation of a specific cluster size rather than a broad distribution of sizes. Lastly, we show that a specific cluster size can be formed, mass-selected, and then transferred to another ion trap for a second completely separate ion processing step. Furthermore, the instrumentation and modular design developed here expand the scope of ionic species and clusters that can be accessed by processing electrosprayed ions.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Erratum to: Soft- and reactive landing of ions onto surfaces: concepts and applications

Soft- and reactive landing of mass-selected ions is gaining attention as a promising approach for the precisely-controlled preparation of materials on surfaces that are not amenable to deposition using conventional methods. A broad range of ionization sources and mass filters are available that make ion soft-landing a versatile tool for surface modification using beams of hyperthermal (<100?eV) ions. The ability to select the mass-to-charge ratio of the ion, its kinetic energy and charge state, along with precise control of the size, shape, and position of the ion beam on the deposition target distinguishes ion soft landing from other surface modification techniques. Soft- and reactive landing have been used to prepare interfaces for practical applications as well as precisely-defined model surfaces for fundamental investigations in chemistry, physics, and materials science. For instance, soft- and reactive landing have been applied to study the surface chemistry of ions isolated in the gas-phase, prepare arrays of proteins for high-throughput biological screening, produce novel carbon-based and polymer materials, enrich the secondary structure of peptides and the chirality of organic molecules, immobilize electrochemically-active proteins and organometallics on electrodes, create thin films of complex molecules, and immobilize catalytically active organometallics as well as ligated metal clusters. In addition, soft landing has enabled investigation of the size-dependent behavior of bare metal clusters in the critical subnanometer size regime where chemical and physical properties do not scale predictably with size. The morphology, aggregation, and immobilization of larger bare metal nanoparticles, which are directly relevant to the design of catalysts as well as improved memory and electronic devices, have also been studied using ion soft landing. This review article begins in section 1 with a brief introduction to the existing applications of ion soft- and reactive landing. Section 2 provides an overview of the ionization sources and mass filters that have been used to date for soft landing of mass-selected ions. A discussion of the competing processes that occur during ion deposition as well as the types of ions and surfaces that have been investigated follows in section 3. Section 4 discusses the physical phenomena that occur during and after ion soft landing, including retention and reduction of ionic charge along with factors that impact the efficiency of ion deposition. The influence of soft landing on the secondary structure and biological activity of complex ions is addressed in section 5. Lastly, an overview of the structure and mobility as well as the catalytic, optical, magnetic, and redox properties of bare ionic clusters and nanoparticles deposited onto surfaces is presented in section 6. © 2015 Wiley Periodicals, Inc. Mass Spec Rev 35:439–479, 2016.

Johnson, Grant E.↗

Data for Selected Ion Monitoring for Orbitrap-Based Metabolomics

Orbitrap mass spectrometry in full scan mode enables the simultaneous detection of hundreds of metabolites and their isotope-labeled forms. Yet, sensitivity remains limiting for many metabolites, including low-concentration species, poor ionizers, and low-fractional-abundance isotope-labeled forms in isotope-tracing studies. Here, we explore selected ion monitoring (SIM) as a means of sensitivity enhancement. The analytes of interest are enriched in the orbitrap analyzer by using the quadrupole as a mass filter to select particular ions. In tissue extracts, SIM significantly enhances the detection of ions of low intensity, as indicated by improved signal-to-noise (S/N) ratios and measurement precision. In addition, SIM improves the accuracy of isotope-ratio measurements. SIM, however, must be deployed with care, as excessive accumulation in the orbitrap of similar m/z ions can lead, via space-charge effects, to decreased performance (signal loss, mass shift, and ion coalescence). Ion accumulation can be controlled by adjusting settings including injection time and target ion quantity. Overall, we suggest using a full scan to ensure broad metabolic coverage, in tandem with SIM, for the accurate quantitation of targeted low-intensity ions, and provide methods deploying this approach to enhance metabolome coverage.f

Mass Spectrometry↗

Meta-Study of Particulate Detection Losses on Radioactive Air Sample Filters

Several mathematical relationships between air sample filter mass loading and the correlated analytical self-absorption factor were developed using data from other published research in this meta-study. Gross-alpha and -beta applications are addressed for this research. As filter media becomes loaded with particulate matter, there is potential for measurement losses due to self-absorption by mass loading. Components contributing to absorption include particulate dust, radioactive particulates, and filter material. Standards indicate a correction factor should be used when the penetration of radioactive material into the collection media or self-absorption of radiation by the material collected would reduce the detection rate by more than 5%. Previously, losses due to self-absorption have been reported up to 100% over a range up to ~10 mg∙cm -2 mass loading. These absorption losses then can be used to determine a correction factor for sample results. For low mass loadings (e.g., ≤0.1 mg∙cm -2 ) corrections factors in the 0.85 - 1 range have been recommended and used, while at higher mass loadings nearer to 10 mg∙cm -2 correction factors closer to 0 (representing near 100% losses) are used. Based on data from published studies, the different methods for relating percent loss due to self-absorption to mass loading include linear, exponential, quadratic, and trinomial derived functions. Where applicable, both forced zero and non-forced zero results were evaluated. From the derived functions evaluated, the trinomial function provided the best fit. Once the sample filter mass loading is known, the trinomial function can be applied to estimate losses and the corresponding self-absorption factor. When applied to routine operating conditions for radiological facility stacks monitored at the Pacific Northwest National Laboratory for an average sample filter mass loading of 0.09 ± 0.12 (2σ) mg∙cm -2 (excluding negative values and outliers) and a range from 0 - 0.24 mg∙cm -2 , the estimated trinomial function nominal self-absorption losses are less than 5% at 0.09 mg∙cm -2 and less than 10% at 0.24 mg∙cm -2 . The trinomial function is one method that may be used to adjust the activity results of an air sample when the sample-specific mass loading is determined. The application of no correction factor when the ANSI/HPS N13.1-2021 guidance of a 5% threshold for loss is not reached with typical stack sample mass loadings may be reasonable in high-efficiency particulate air filtered systems. For simplicity, it would be conservative in assigning the self-absorption correction factor at the 5% threshold (i.e., 0.95) for general uses but in cases of heavy mass loading to calculate the factor.

air sampling↗

Mass-selected ion–molecule cluster beam apparatus for ultrafast photofragmentation studies

We describe an apparatus for investigating the excited-state dissociation dynamics of mass-selected ion–molecule clusters by mass-resolving and detecting photofragment-ions and neutrals, in coincidence, using an ultrafast laser operating at high repetition rates. The apparatus comprises a source that generates ion–molecule clusters, a time-of-flight spectrometer, and a mass filter that selects the desired anions, and a linear-plus-quadratic reflectron mass spectrometer that discriminates the fragment anions after the femtosecond laser excites the clusters. The fragment neutrals and anions are then captured by two channeltron detectors. The apparatus performance is tested by measuring the photofragments: I – , CF 3 I – , and neutrals from photoexcitation of the ion–molecule cluster CF 3 I·I – using femtosecond UV laser pulses with a wavelength of 266 nm. Here, the experimental results are compared with our ground state and excited state electronic structure calculations as well as the existing results and calculations, with particular attention to the generation mechanism of the anion fragments and dissociation channels of the ion–molecule cluster CF 3 I·I – in the charge-transfer excited state.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Damped Ly α absorbers and atomic hydrogen in galaxies: the view of the GAEA model

ABSTRACT Using the GAEA semi-analytic model, we analyse the connection between Damped Ly α systems (DLAs) and H i in galaxies. Our state-of-the-art semi-analytic model is tuned to reproduce the local galaxy H i mass function, and that also reproduces other important galaxy properties, including the galaxy mass–gas metallicity relation. To produce catalogues of simulated DLAs we throw 105 random lines of sight in a composite simulated volume: dark matter haloes with log$(\frac{M_{200}}{ {\rm M}_{\odot }}) \ge 11.5$ are extracted from the Millennium Simulation, while for $9.2 \le \log (\frac{M_{200}}{ \mathrm{M}_{\odot }})\lt 11.5$ we use the Millennium II, and for $8 \le \log (\frac{M_{200}}{\mathrm{M}_{\odot }}) \lt 9.2$ a halo occupation distribution model. At 2 < z < 3, where observational data are more accurate, our fiducial model predicts the correct shape of the column density distribution function, but its normalization falls short of the observations, with the discrepancy increasing at higher redshift. The agreement with observations is significantly improved increasing both the H i masses and the disc radii of model galaxies by a factor of 2, as implemented ‘a posteriori’ in our 2M−2R model. In the redshift range of interest, haloes with $M_{200} \ge {10}^{11} \, \mathrm{M}_{\odot }$ give the major contribution to ΩDLA, and the typical DLA host halo mass is $\sim \!{10}^{11} \, \mathrm{M}_{\odot }$. The simulated DLA metallicity distribution is in relatively good agreement with observations, but our model predicts an excess of DLAs at low metallicities. Our results suggest possible improvements for the adopted modelling of the filtering mass and metal ejection in low-mass haloes.

Di Gioia, Serafina↗

MassIVE MSV000094084 - Data files for manuscript - Selected ion monitoring for orbitrap-based metabolomics: Please open README-data-for-SIM-paper-20240210.doc for details.

Orbitrap mass spectrometry in full scan mode enables the simultaneous detection of hundreds of metabolites and their isotope-labeled forms. Yet, sensitivity remains limiting for many metabolites, including low-concentration species, poor ionizers, and low-fractional-abundance isotope-labeled forms in isotope-tracing studies. Here, we explore selected ion monitoring (SIM) as a means of sensitivity enhancement. The analytes of interest are enriched in the orbitrap analyzer by using the quadrupole as a mass filter to select particular ions. In tissue extracts, SIM significantly enhances the detection of ions of low intensity, as indicated by improved signal-to-noise (S/N) ratios and measurement precision. In addition, SIM improves the accuracy of isotope-ratio measurements. SIM, however, must be deployed with care, as excessive accumulation in the orbitrap of similar m/z ions can lead, via space-charge effects, to decreased performance (signal loss, mass shift, and ion coalescence). Ion accumulation can be controlled by adjusting settings including injection time and target ion quantity. Overall, we suggest using a full scan to ensure broad metabolic coverage, in tandem with SIM, for the accurate quantitation of targeted low-intensity ions, and provide methods deploying this approach to enhance metabolome coverage. Please open README-data-for-SIM-paper-20240210.doc for details. [doi:10.25345/C5JH3DD3K] [dataset license: CC0 1.0 Universal (CC0 1.0)]

Rabinowitz, Joshua↗

Selected Ion Monitoring for Orbitrap-Based Metabolomics

Orbitrap mass spectrometry in full scan mode enables the simultaneous detection of hundreds of metabolites and their isotope-labeled forms. Yet, sensitivity remains limiting for many metabolites, including low-concentration species, poor ionizers, and low-fractional-abundance isotope-labeled forms in isotope-tracing studies. Here, we explore selected ion monitoring (SIM) as a means of sensitivity enhancement. The analytes of interest are enriched in the orbitrap analyzer by using the quadrupole as a mass filter to select particular ions. In tissue extracts, SIM significantly enhances the detection of ions of low intensity, as indicated by improved signal-to-noise (S/N) ratios and measurement precision. In addition, SIM improves the accuracy of isotope-ratio measurements. SIM, however, must be deployed with care, as excessive accumulation in the orbitrap of similar m/z ions can lead, via space-charge effects, to decreased performance (signal loss, mass shift, and ion coalescence). Ion accumulation can be controlled by adjusting settings including injection time and target ion quantity. Overall, we suggest using a full scan to ensure broad metabolic coverage, in tandem with SIM, for the accurate quantitation of targeted low-intensity ions, and provide methods deploying this approach to enhance metabolome coverage.

59 BASIC BIOLOGICAL SCIENCES↗

Progress towards the FRIB-EDM 3 -Frontend: A tool to provide radioactive molecules from isotope harvesting for fundamental symmetry studies

The under-construction FRIB-EDM 3 -instrument was designed to study polar radioactive molecules (such as RaF) in transparent cryogenic solids by laser spectroscopy. The instrument is divided into a frontend- and a backend section. The frontend accepts an aqueous sample from isotope harvesting and provides a mass-separated molecular ion beam in an ultra-high vacuum environment. In the backend, the ions are guided into alkali-metal vapor and the resulting neutrals are co-deposited in a solid argon matrix to perform laser spectroscopy. Here, this work addresses the frontend of the instrument. The efficient ionization of harvested radioisotopes from aqueous samples is achieved with a spray-ionization method. Subsequently, the molecular ion beam is analyzed by mass-to-charge ratio by a quadrupole mass filter. To verify the feasibility of the approach, numerical simulations with the COMSOL and SIMION packages have been conducted. While the former was applied to study transport in ion funnels, the latter was used to investigate ion beam transmission through the lower pressure sections. Following promising simulation results, a first experimental setup is under construction.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Curious cross-field transport effects in multi-ion, magnetized plasma

In contrast to single-ion plasma, multiple-ion-species plasma exhibits new, curious, and large transport effects. On short timescales, where ions exchange momentum, magnetized multi-ion plasma behaves as a most unusual substance, compressible across field lines in number density but incompressible in charge density. It takes 40 times longer for electrons to participate. In this ion–ion cross-field transport regime, we identified the charge-incompressibility heat pump effect, transferring heat both spatially and between species. Curiously, the direction of impurity transport strongly depends on plasma magnetization, characterized by the ratio of light ion gyrofrequency to the collision frequency between light and heavy ion species. The expulsion of heavy ion impurities from a hotspot occurs sufficiently quickly to be observable on MagLIF, so long as plasma becomes sufficiently collisionally magnetized under implosion. Even more curious, multi-ion transport changes its nature in partially ionized plasma, where ions occupy different charge states. In this regime, we identify a partial-ionization deconfinement effect. The combination of cross-field transport, ionization, and recombination leads to a net ion charge moving across magnetic field lines on the ion–ion transport timescale as opposed to the electron–ion transport timescale. Cross-field transport effects in multi-ion plasma are important in a number of applications, including nuclear fusion and plasma mass filters.

Mlodik, M. E. (ORCID:0000000343003941)↗

Prediction for Pressure Differential Across HEPA Filter Media Based on Media Characteristics and Particle Size Distribution

A new method for predicting the pressure drop across High Efficiency Particulate Air (HEPA) filter media is proposed based upon mass deposited onto the filter and known physical characteristics of the filter media. Detailed are the methods used in conjunction with current filter loading models to predict the pressure drop, as well as tests conducted to validate the methods. The benefit of a prediction model for practical use lies in the manufacturing and service life of nuclear grade HEPA filters. HEPA filters for use in nuclear facilities have a prescribed expiration date and a maximum allowable operating pressure drop. Therefore, the ability to predict the pressure drop across a filter and relate it to an expected length of service time can enable a reduction in wasted filters. This will allow for more informed decisions to be made based upon the dictated life cycle of the filters. Also, understanding and predicting how the pressure drop of HEPA filter media behaves as a function of physical characteristics and loaded mass can assist in future design and manufacturing of filter media. Currently, most existing pressure drop models are either computationally based or analytical methods relying on data gathered during tests. Neither are practical for prediction; the computational methods are difficult to implement, and the current analytical methods are more useful as tools for analysis. The current analytical model developed by Bergman et al. is based upon the pressure drop from each media fiber and modeling the deposited particles as newly formed fibers. Using Bergman's model and the media properties, air properties, and known aerosol particle size distribution, a pressure drop curve as a function of loaded mass can be created. This curve implies initial loading in the depth of the filter media with a transition to pure surface loading on the filter face, and a sensitivity to an evolving particle size distribution as mass continues to load onto the filter. To implement the predictive model, knowledge of the mean filter fiber diameter and porosity of the filter media is required. Traditionally, the mean fiber diameter is calculated as an effective diameter from prior media testing, however, in this study a Scanning Electron Microscope (SEM) technique is used to acquire this variable. Validation of the predictive model is provided by flat sheet media tests under a controlled environment with a measured particle size distribution of the challenge aerosol and shows reasonable preliminary agreement.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

SECAR: A recoil separator for nuclear astrophysics

Proton-and alpha-capture reactions on unstable proton-rich nuclei power astrophysical explosions like novae and X-ray bursts. Direct measurements of these reactions are crucial for understanding the mechanisms behind these explosions and the nucleosynthesis at such sites. The recoil mass separator, SECAR (SEparator for CApture Reactions) at the National Superconducting Cyclotron Laboratory (NSCL) and the Facility for Rare Isotope Beams (FRIB), has been designed with the required sensitivity to study (p,γ) and (α,γ) reactions, directly at astrophysical energies in inverse kinematics, with radioactive beams of masses up to about A = 65. The complete SECAR system, including two Wien Filters for high mass resolution, has been installed at Michigan State University and is currently being commissioned. The present article introduces the SECAR concept, its scientific goals, and provides an update of the current status of the project.

Tsintari, P↗

Evaluation of methods for characterizing the fine particulate matter emissions from aircraft and other diffusion flame combustion aerosol sources

The U. S. Environmental Protection Agency in collaboration with the U. S. Air Force Arnold Engineering Development Complex conducted the VAriable Response In Aircraft nvPM Testing (VARIAnT) 3 and 4 test campaigns to compare nvPM emissions measurements from a variety of diffusion flame combustion aerosol sources (DFCASs), including a Cummins diesel engine, a diesel powered generator, two gas turbine start carts, a J85-GE-5 turbojet engine burning multiple fuels, and a Mini-CAST soot generator. The VARIAnT research program has conducted four test campaigns to date with the VARIAnT 3 and 4 test campaigns focusing on BC mass instrument performance, use of gas turbine engine sources for BC mass instrument calibration, and the characterization of the aerosols produced from the combustion sources. Results from both campaigns revealed agreement of about 20% between the AVL Micro-Soot Sensor, the Cavity Attenuated Phase Shift (CAPS PMSSA) monitor and the thermal-optical reference method for elemental carbon (EC), independent of the calibration source used. For the Artium LII-300, the measured mass concentrations in VARIAnT3 fall within 18% and in VARIAnT4 fall within 32% of the reference EC mass concentration when calibrated on a combustor rig in VARIAnT3 and on a LGT-60 start cart in VARIAnT4, respectively. It was also found that the three mass instrument types (MSS, CAPS PMSSA, and LII-300) can exhibit different BC to reference EC ratios depending on the emission source that appear to correlate to particle geometric mean mobility diameter, morphology, or some other parameter associated with particle geometric mean diameter (GMD) with the LII-300 showing a slightly stronger apparent trend with GMD. Systematic differences in LII-300 measured mass concentrations have been reduced by calibrating with a turbine combustion source (combustor or turbine engine). With respect to the particle size measurements made, the sizing instruments (TSI SMPS, TSI EEPS, and Cambustion DMS 500) were found to be in general agreement in terms of size distributions and concentrations with some exceptions. Teflon filter measurements of the total aerosol mass produced by the various DFCASs differed from the reference EC, BC, and integrated particle sized distribution measured aerosol masses. The Teflon filter measured mass was 30 to 40% greater than the reference EC and 50 to 60% greater than the BC mass for the J85 in both test campaigns. The measurements of particle size distributions and single particle analysis by miniSPLAT indicated the presence of large particles (>100 nm) having more compact morphologies, higher effective density, and a composition dominated by OC and ash. This increased large particle fraction is also associated with higher values of single scattering albedo measured by the CAPS PMSSA instrument and higher OC/EC measurements. These measurements indicate gas turbine engine emissions can be a more heterogeneous mix of particle types beyond the original E31 assumption that it is mainly composed of black carbon.

33 ADVANCED PROPULSION SYSTEMS↗

Experimental investigation of the effect of pore size distribution on nano-particle capture efficiency within ceramic particulate filters

The effect of the pore size distribution on size-resolved filtration efficiency was investigated for two ceramic particulate filters using particulate matter (PM) generated by a spark-ignition direct-injection engine fueled with gasoline. The cordierite filter tested had a porosity of 43%, a median pore diameter (d_50) of 12 µm, and a wide pore size distribution with a lognormal standard deviation (s’) of 0.3. The aluminum titanate filter had very similar porosity, d_50, and thickness, but significantly narrower pore size distribution (s’ = 0.1). The testing of two filters under identical experimental conditions enabled the impact of the pore size distribution on filtration performance to be evaluated. Filtration experiments were performed focusing on just the filter wall, starting from a clean filter until the transition to cake filtration (filtration efficiency > 99%). Time-resolved particle size distribution measurements were used to evaluate the progression of filtration performance and estimate trapped mass within the filter. The aluminum titanate filter, with a narrow pore size distribution, exhibited significantly better diffusion capture efficiency. The negative impact of higher flow velocity on diffusion capture efficiency was more pronounced for a narrower pore size distribution. Flow distributions measured using capillary-flow porometry were used to develop a cylindrical pore flow model to understand the impact of the differences in pore size distribution on observed trends in diffusion capture efficiency within a clean filter. The model helps demonstrate how large pores on the high end of a wider pore size distribution can carry a large fraction of the flow, with less efficient capture of small particles by diffusion. The experimental results and data demonstrate that the bubble point diameter and width of the pore size distribution significantly influence diffusion capture efficiencies for filters with very similar median pore diameter, porosity, and thickness.

aerosol filtration, Aftertreatment, ceramic exhaus↗

Impacts of engine lubrication oil-derived ash on soot oxidative reactivity on a catalytic gasoline particulate filter

Characterizing soot oxidation kinetics is crucial for understanding how gasoline particulate filters (GPFs) perform both in terms of filtration efficiency and pressure drop. The most common method for measuring soot oxidative reactivity is thermogravimetric analysis (TGA). Because TGA is an offline method, it may inaccurately predict how soot oxidizes on a GPF, especially if a catalytic washcoat is present that may enhance oxidation rates through surface interactions as the soot loads on the filter. In this work, a novel in-situ soot oxidative reactivity measurement method was developed. The method involved loading a catalytic GPF under high temperature conditions conducive to soot oxidation and measuring the filtration efficiency of 100 nm particles. A correlation was made between filtration efficiency and loaded soot mass on the filter to allow calculation of the soot oxidation rate. The method was evaluated in experiments using a 2.0 L gasoline direct injection (GDI) engine with three oils of varying additive packages, including an oil with a high zinc dialkyldithiophosphate (ZDDP) concentration, a non-additive, pure poly-alpha olefin (PAO) oil, and an oil with a high concentration of calcium sulfonate. Calculated specific soot oxidation rates ranged from ~0.06–0.6 min –1 and showed strong dependence on GPF inlet gas temperature and lubrication oil additive type. The results clearly demonstrated a catalytic effect of calcium-containing ash particles. Reactivity of soot produced by the engine running with the high calcium containing lubrication oil was increased. Similarly, the results indicated that the catalytic washcoat on the filter increased soot oxidation rates on-filter, especially at low soot loading. Conversely, the ZDDP oil additive exhibited a reactivity inhibiting effect, resulting in lower soot oxidation rates. Finally, this work represents the first known in-situ soot oxidative reactivity measurements on a GPF and elucidates the effect of lubrication oil additives and catalytic washcoat on oxidation rate.

42 ENGINEERING↗