Water Security Toolkit User Manual Version 1.2.

The Water Security Toolkit (WST) is a suite of open source software tools that can be used by water utilities to create response strategies to reduce the impact of contamination in a water distribution network . WST includes hydraulic and water quality modeling software , optimizati on methodologies , and visualization tools to identify: (1) sensor locations to detect contamination, (2) locations in the network in which the contamination was introduced, (3) hydrants to remove contaminated water from the distribution system, (4) locations in the network to inject decontamination agents to inactivate, remove, or destroy contaminants, (5) locations in the network to take grab sample s to help identify the source of contamination and (6) valves to close in order to isolate contaminate d areas of the network. This user manual describes the different components of WST , along w ith examples and case studies. License Notice The Water Security Toolkit (WST) v.1.2 Copyright c 2012 Sandia Corporation. Under the terms of Contract DE-AC04-94AL85000, there is a non-exclusive license for use of this work by or on behalf of the U.S. government. This software is distributed under the Revised BSD License (see below). In addition, WST leverages a variety of third-party software packages, which have separate licensing policies: Acro Revised BSD License argparse Python Software Foundation License Boost Boost Software License Coopr Revised BSD License Coverage BSD License Distribute Python Software Foundation License / Zope Public License EPANET Public Domain EPANET-ERD Revised BSD License EPANET-MSX GNU Lesser General Public License (LGPL) v.3 gcovr Revised BSD License GRASP AT&T Commercial License for noncommercial use; includes randomsample and sideconstraints executable files LZMA SDK Public Domain nose GNU Lesser General Public License (LGPL) v.2.1 ordereddict MIT License pip MIT License PLY BSD License PyEPANET Revised BSD License Pyro MIT License PyUtilib Revised BSD License PyYAML MIT License runpy2 Python Software Foundation License setuptools Python Software Foundation License / Zope Public License six MIT License TinyXML zlib License unittest2 BSD License Utilib Revised BSD License virtualenv MIT License Vol Common Public License vpykit Revised BSD License Additionally, some precompiled WST binary distributions might bundle other third-party executables files: Coliny Revised BSD License (part of Acro project) Dakota GNU Lesser General Public License (LGPL) v.2.1 PICO Revised BSD License (part of Acro project) i Revised BSD License Redistribution and use in source and binary forms, with or without modification, are permitted provided that the following conditions are met: * Redistributions of source code must retain the above copyright notice, this list of conditions and the following disclaimer. * Redistributions in binary form must reproduce the above copyright notice, this list of conditions and the following disclaimer in the documentation and/or other materials provided with the distribution. * Neither the name of Sandia National Laboratories nor Sandia Corporation nor the names of its con- tributors may be used to endorse or promote products derived from this software without specific prior written permission. THIS SOFTWARE IS PROVIDED BY THE COPYRIGHT HOLDERS AND CONTRIBUTORS "AS IS" AND ANY EXPRESS OR IMPLIED WARRANTIES, INCLUDING, BUT NOT LIMITED TO, THE IM- PLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE ARE DISCLAIMED. IN NO EVENT SHALL SANDIA CORPORATION BE LIABLE FOR ANY DIRECT, INDIRECT, INCIDENTAL, SPECIAL, EXEMPLARY, OR CONSEQUENTIAL DAMAGES (INCLUD- ING, BUT NOT LIMITED TO, PROCUREMENT OF SUBSTITUTE GOODS OR SERVICES; LOSS OF USE, DATA, OR PROFITS; OR BUSINESS INTERRUPTION) HOWEVER CAUSED AND ON ANY THEORY OF LIABILITY, WHETHER IN CONTRACT, STRICT LIABILITY, OR TORT (INCLUDING NEGLIGENCE OR OTHERWISE) ARISING IN ANY WAY OUT OF THE USE OF THIS SOFTWARE, EVEN IF ADVISED OF THE POSSIBILITY OF SUCH DAMAGE. ii Acknowledgements This work was supported by the U.S. Environmental Protection Agency through its Office of Research and Development (Interagency Agreement # DW8992192801). The material in this document has been subject to technical and policy review by the U.S. EPA, and approved for publication. The views expressed by individual authors, however, are their own, and do not necessarily reflect those of the U.S. Environmental Protection Agency. Mention of trade names, products, or services does not convey official U.S. EPA approval, endorsement, or recommendation. The Water Security Toolkit is an extension of the Threat Ensemble Vulnerability Assessment-Sensor Place- ment Optimization Tool (TEVA-SPOT), which was also developed with funding from the U.S. Environ- mental Protection Agency through its Office of Research and Development (Interagency Agreement # DW8992192801). The authors acknowledge the following individuals for their contributions to the devel- opment of TEVA-SPOT: Jonathan Berry (Sandia National Laboratories), Erik Boman (Sandia National Laboratories), Lee Ann Riesen (Sandia National Laboratories), James Uber (University of Cincinnati), and Jean-Paul Watson (Sandia National Laboratories). iii Acronyms ATUS American Time-Use Survey BLAS Basic linear algebra sub-routines CFU Colony-forming unit CVAR Conditional value at risk CWS Contamination warning system EA Evolutionary algorithm EDS Event detection system EPA U.S. Environmental Protection Agency EC Extent of Contamination ERD EPANET results database file GLPK GNU Linear Programming Kit GRASP Greedy randomized adaptive sampling process HEX Hexadecimal HTML HyperText markup language INP EPANET input file LP Linear program MC Mass consumed MILP Mixed integer linear program MIP Mixed integer program MSX Multi-species extension for EPANET NFD Number of failed detections NS Number of sensors NZD Non-zero demand PD Population dosed PE Population exposed PK Population killed TAI Threat assessment input file TCE Tailed-conditioned expectation TD Time to detection TEC Timed extent of contamination TEVA Threat ensemble vulnerability assessment TSB Tryptic soy broth TSG Threat scenario generation file TSI Threat simulation input file VAR Value at risk VC Volume consumed WST Water Security Toolkit YML YAML configuration file format for WST iv Symbols Notation Definition Example { , } set brackets { 1,2,3 } means a set containing the values 1,2, and 3. [?] is an element of s [?] S means that s is an element of the set S . [?] for all s = 1 [?] s [?] S means that the statement s = 1 is true for all s in set S . P summation P n i =1 s i means s 1 + s 2 + * * * + s n . \ set minus S \ T means the set that contains all those elements of S that are not in set T . %7C given %7C is used to define conditional probability. P ( s %7C t ) means the prob- ability of s occurring given that t occurs. %7C ... %7C cardinality Cardinality of a set is the number of elements of the set. If set S = { 2,4,6 } , then %7C S %7C = 3. v

Klise, Katherine A.↗

Model MC&A for Pebble Bed Reactors (Technical Direction No. 5 Task 2.6 Letter Report)

In preparation for non-light water reactor (non-LWR) activities, US Nuclear Regulatory Commission (NRC) staff are advancing risk-informed and performance-based licensing approaches and addressing key policy issues. One non-LWR reactor concept is a pebble bed reactor (PBR). This reactor design uses spherical fuel elements (pebbles) that are continually added to and removed from the reactor core. The free movement of the fuel in this design presents new challenges for material control and accounting (MC&A) programs. Therefore, an assessment of MC&A program features and measures for a PBR was performed to help NRC staff develop associated MC&A regulations or regulatory guides. The current regulatory framework for non-LWR fuel cycles excludes support for licensing reviews for MC&A programs for PBRs. Licensing reviews of an MC&A program for PBRs can be facilitated by (1) a model MC&A program for a PBR based on identification and assessment of MC&A program features and recommended measures for a reference PBR and (2) a methodology for assessing MC&A performance that can help assess different MC&A program features and measures. This report supports the NRC’s non-LWR Vision and Strategy Near-Term Implementation Action Plans.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Differences among Monte Carlo codes in the calculations of voxel S values for radionuclide targeted therapy and analysis of their impact on absorbed dose evaluations

Several updated Monte Carlo (MC) codes are available to perform calculations of voxel S values for radionuclide targeted therapy. The aim of this work is to analyze the differences in the calculations obtained by different MC codes and their impact on absorbed dose evaluations performed by voxel dosimetry. Voxel S values for monoenergetic sources (electrons and photons) and different radionuclides ({sup 90}Y, {sup 131}I, and {sup 188}Re) were calculated. Simulations were performed in soft tissue. Three general-purpose MC codes were employed for simulating radiation transport: MCNP4C, EGSnrc, and GEANT4. The data published by the MIRD Committee in Pamphlet No. 17, obtained with the EGS4 MC code, were also included in the comparisons. The impact of the differences (in terms of voxel S values) among the MC codes was also studied by convolution calculations of the absorbed dose in a volume of interest. For uniform activity distribution of a given radionuclide, dose calculations were performed on spherical and elliptical volumes, varying the mass from 1 to 500 g. For simulations with monochromatic sources, differences for self-irradiation voxel S values were mostly confined within 10% for both photons and electrons, but with electron energy less than 500 keV, the voxel S values referred to the first neighbor voxels showed large differences (up to 130%, with respect to EGSnrc) among the updated MC codes. For radionuclide simulations, noticeable differences arose in voxel S values, especially in the bremsstrahlung tails, or when a high contribution from electrons with energy of less than 500 keV is involved. In particular, for {sup 90}Y the updated codes showed a remarkable divergence in the bremsstrahlung region (up to about 90% in terms of voxel S values) with respect to the EGS4 code. Further, variations were observed up to about 30%, for small source-target voxel distances, when low-energy electrons cover an important part of the emission spectrum of the radionuclide (in our case, for {sup 131}I). For {sup 90}Y and {sup 188}Re, the differences among the various codes have a negligible impact (within few percents) on convolution calculations of the absorbed dose; thus either one of the MC programs is suitable to produce voxel S values for radionuclide targeted therapy dosimetry. However, if a low-energy beta-emitting radionuclide is considered, these differences can affect also dose depositions at small source-target voxel distances, leading to more conspicuous variations (about 9% for {sup 131}I) when calculating the absorbed dose in the volume of interest.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Facility Measurements

Measurements are the basis of accounting for inventories and transfers and provide assurance that no nuclear material is missing. They provide information on quantities, isotopic composition and weight percent determination of nuclear material in given locations which is essential to determining category levels and protection requirements. Los Alamos National Laboratory (LANL) uses confirmatory and verification measurements to meet DOE requirements when moving or processing material on External Receipts, External Shipments, Internal Transfers, Processing, and Physical Inventories. This presentation provides details on what type of measurement is required based on several factors. These factors include but are not limited to Category of the Material, application of Tamper Indicating Devices (TID), application of the measurement, and graded safeguards. These elements are part of the overall MC&A program required to effectively control and account for nuclear materials. LANL depends on multiple organizations to take the measurements and monitor the controls of instruments required to have an effective program. The MC&A group does oversight and control of all standards and instruments. The NDA group manages the day-to-day measurement control activities and does NDA measurements while the operations people use balances in their day-to-day processing. Confirmatory and Verification measurements are used throughout the nuclear material life cycle to verify inventories and detect theft or diversion of nuclear materials.

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗

NTS MC&A History

Within the past three and a half years, the Nevada Test Site (NTS) has progressed from a Category IV to a Category I nuclear material facility. In accordance with direction from the U.S. Department of Energy (DOE) Secretary and National Nuclear Security Administration (NNSA) Administrator, NTS received shipments of large quantities of special nuclear material from Los Alamos National Laboratory (LANL) and other sites in the DOE complex. December 2004 was the first occurrence of Category I material at the NTS, with the exception of two weeks of sub-critical underground testing in 2001, since 1992. The Material Control and Accountability (MC&A) program was originally a jointlab effort by LANL, Lawrence Livermore National Laboratory, and Bechtel Nevada, but in March 2006 the NNSA Nevada Site Office appointed the NTS Management and Operations contractor with sole responsibility. This paper will discuss the process and steps taken to transition the NTS MC&A program from multiple organizations to a single entity and from a Category IV to a Category I program. This transition flourished as MC&A progressed from the 2004 Office of Assessment (OA) rating of “Significant Weakness” to the 2007 OA assessment rating of “Effective Performance.” The paper will provide timelines, funding and staffing issues, OA assessment findings and corrective actions, and future expectations. The process has been challenging, but MC&A’s innovative responses to the challenges have been very successful.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

NTS MC&A History

Within the past three years, the Nevada Test Site (NTS) has progressed from a Category IV to a Category I facility. In accordance with direction from the U. S. Department of Energy (DOE) Secretary and National Nuclear Security Administration (NNSA) Administrator, NTS received shipments of large quantities of special nuclear material from Los Alamos National Laboratory (LANL) and other sites in the DOE complex. September 2004 was the first occurrence of Category I material at the NTS, with the exception of two weeks of underground testing in 2001, since 1992. The Material Control and Accountability (MC&A) program was originally a joint-lab effort by LANL, Lawrence Livermore National Laboratory (LLNL), and Bechtel Nevada (BN), but in March 2006 the NNSA Nevada Site Office appointed the NTS Management and Operations contractor with sole responsibility. This paper will discuss the process and steps taken to transition the NTS MC&A program from multiple disciplines to a single entity and from a Category IV to a Category I program. This transition flourished as MC&A progressed from the 2004 Office of Assessment (OA) rating of “Significant Weakness” to the 2007 OA assessment rating of “Effective Performance.” The paper will provide timelines, funding and staffing issues, OA assessment findings and corrective actions, and future expectations. The process has been challenging, and MC&A’s innovative responses to the challenges have been very successful.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

MATERIAL CONTROL ACCOUNTING INMM

Since 1996, the Mining and Chemical Combine (MCC - formerly known as K-26), and the United States Department of Energy (DOE) have been cooperating under the cooperative Nuclear Material Protection, Control and Accounting (MPC&A) Program between the Russian Federation and the U.S. Governments. Since MCC continues to operate a reactor for steam and electricity production for the site and city of Zheleznogorsk which results in production of the weapons grade plutonium, one of the goals of the MPC&A program is to support implementation of an expanded comprehensive nuclear material control and accounting (MC&A) program. To date MCC has completed upgrades identified in the initial gap analysis and documented in the site MC&A Plan and is implementing additional upgrades identified during an update to the gap analysis. The scope of these upgrades includes implementation of MCC organization structure relating to MC&A, establishing material balance area structure for special nuclear materials (SNM) storage and bulk processing areas, and material control functions including SNM portal monitors at target locations. Material accounting function upgrades include enhancements in the conduct of physical inventories, limit of error inventory difference procedure enhancements, implementation of basic computerized accounting system for four SNM storage areas, implementation of measurement equipment for improved accountability reporting, and both new and revised site-level MC&A procedures. This paper will discuss the implementation of MC&A upgrades at MCC based on the requirements established in the comprehensive MC&A plan developed by the Mining and Chemical Combine as part of the MPC&A Program.

99 GENERAL AND MISCELLANEOUS↗

US-Russian Cooperation in Upgrading MC&A System at Rosatom Facilities: Measurement of Nuclear Materials

Improve protection of weapons-usable nuclear material from theft or diversion through the development and support of a nationwide sustainable and effective Material Control and Accountability (MC&A) program based on material measurement. The material protection, control, and accountability (MPC&A) cooperation has yielded significant results in implementing MC&A measurements at Russian nuclear facilities: (1) Establishment of MEM WG and MEMS SP; (2) Infrastructure for development, certification, and distribution of RMs; and (3) Coordination on development and implementation of MMs.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Diversion Path Analysis: A Proposed Methodology to Develop an MC&A Approach for Liquid-Fueled Molten Salt Reactors

Nuclear material control and accounting (MC&A) is a critical element of both the US Nuclear Regulatory Commission (NRC) and US Department of Energy (DOE)’s domestic safeguards and security requirements. NRC licensees are required, under Title 10 of the Code of Federal Regulations (10 CFR) Part 74 to establish and maintain an MC&A program that captures and records the quantities and locations of special nuclear material (SNM) at the facility. Along with physical protection, MC&A is a key element of domestic nuclear material safeguards that enables the NRC to ensure that SNM is controlled and accounted for. SNM, per 10 CFR Part 74, refers to plutonium, 233 U, and uranium enriched in the isotope 233 U or 235 U, but does not include source material. Periodic physical inventories, coupled with material balance evaluations, are effective and demonstrated tools to account for and detect theft or diversion of SNM in facilities containing SNM in bulk material form (i.e., not in discrete, countable items). Historically in the United States, these types of facilities have included fuel fabrication, conversion, and enrichment facilities. In comparison, reactors have relied on item counting of assemblies and control of SNM while in containment (e.g., a sealed reactor pressure vessel) because, to date, reactor fuel has been in item form. In liquid-fueled molten salt reactors (MSRs), unlike traditional light water reactors (LWRs) or bulk facilities, bulk SNM quantities can change significantly during operation as a result of depletion and transmutation. This introduces challenges to the use of traditional periodic physical inventories and material balance evaluations to detect theft or diversion of SNM in reactors that use SNM in bulk material form. Liquid-fueled (i.e., salt-fueled) MSR facilities are MSRs that use SNM within a salt eutectic as the fuel. The SNM is in a bulk material form any time it is outside of fresh or spent fuel storage containers. Some examples of when SNM will be in bulk form in the facility are during addition of fuel to the reactor system, while fuel is circulating in operation, and while fuel is in a drain tank. Periodic physical inventories and material balance evaluations can likely be effectively applied to many portions of an MSR facility, including all areas where depletion and transmutation are not significantly changing the quantities of SNM within the control area. Within an MSR facility, this would include fresh fuel receipt and loading, waste streams that may contain SNM, irradiated fuel storage outside of the reactor core, and any irradiated fuel processing that may happen after SNM has been removed from the reactor. All of these process steps could rely on measurements of SNM quantities compared with documented inventories. Any discrepancies from predicted (i.e., book) inventories and measured inventories could be quantified as inventory differences, consistent with traditional MC&A guidance from the NRC (e.g., in NUREG-1065 Revision 2, NUREG-2159 Revision 1, and RG 5.29 Revision 2). Within the reactor system, additions and removals to the book inventory include depletion of the SNM (e.g., fission of 235 U), which complicates the use of physical inventories. SNM control, however, can also likely be effectively applied to detect theft of SNM throughout a liquid-fueled MSR facility. To complement these approaches, prior technical reports have identified that a diversion path analysis may be a useful, risk-informed, and performance-based tool to determine suitable elements of an MC&A approach for the reactor system within a liquid-fueled MSR facility.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

ENHANCEMENT OF MATERIAL CONTROL AND ACCOUNTING PROGRAMS THROUGH THE CONDUCT OF GAP ANALYSIS AND THE DEVELOPMENT AND IMPLEMENTATION OF A COMPREHENSIVE MCA PROGRAM PLAN

An effective safeguards program for nuclear materials is dependent on the integration of activities in the traditional safeguards elements: physical protection, protective force, and material control and accounting (MC&A). The design and integration of these traditional safeguards elements must be based on a technical analysis performed in characterizing the vulnerabilities and related risks of the facility against a designed-basis threat. Each of these elements requires a near seamless integration with each other, as well as within a site's operations organization. One of the key objectives of an effective nuclear Material Control and Accountability (MC&A) program is to address the threat posed by an active or passive 'insider' who, acting alone or in collusion, could attempt protracted or abrupt diversion or theft of special nuclear material (SNM). The function of material accountancy is to detect the loss or unauthorized removal of special nuclear material from the plant or facility in a timely manner. Detection is accomplished by means of measurements and transfer records of material movements and periodic inventories to verify that all material is accounted for. The function of material control is to assure the integrity of the nuclear material and the accountancy data. This paper focuses on the development and implementation of a detailed material control and accounting program plan that considers both regulatory compliance demands and performance standards. Consideration of both of these demands is necessary to reduce exposure to theft and diversion, to reduce regulatory jeopardy, and to minimize to the extent possible adverse impacts with site operations.

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗

Control Boundary Analysis for Liquid-Fueled Molten Salt Reactors

The US Nuclear Regulatory Commission (NRC) will likely require license applicants for liquid-fueled molten salt reactors (MSRs) with circulating fuel to submit a nuclear material control and accounting (MC&A) plan or provide a detailed MC&A program description for the facility. In liquid-fueled MSRs with special nuclear material (SNM) in bulk form (i.e., not in discrete items) and with rapidly changing quantities due to fuel transmutation and depletion, a novel MC&A approach is needed because traditional nuclear material accounting methods with material balance evaluations will not be sufficient. This report details the continued efforts carried out at Oak Ridge National Laboratory (ORNL) during FY 2025 to develop a distinct MC&A approach suitable specifically for domestic safeguards of the first-of-a-kind MSRs. These efforts are built on previous ORNL efforts reported in ORNL/SPR-2023/3181 and ORNL/SPR-2024/3555.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Dose Reduction Study in Vaginal Balloon Packing Filled With Contrast for HDR Brachytherapy Treatment;HDR; Uterine cervix cancer; Vaginal balloon packing; Contrast; Monte Carlo

Purpose: Vaginal balloon packing is a means to displace organs at risk during high dose rate brachytherapy of the uterine cervix. We tested the hypothesis that contrast-filled vaginal balloon packing reduces radiation dose to organs at risk, such as the bladder and rectum, in comparison to water- or air-filled balloons. Methods and Materials: In a phantom study, semispherical vaginal packing balloons were filled with air, saline solution, and contrast agents. A high dose rate iridium-192 source was placed on the anterior surface of the balloon, and the diode detector was placed on the posterior surface. Dose ratios were taken with each material in the balloon. Monte Carlo (MC) simulations, by use of the MC computer program DOSXYZnrc, were performed to study dose reduction vs. balloon size and contrast material, including commercially available iodine- and gadolinium-based contrast agents. Results: Measured dose ratios on the phantom with the balloon radius of 3.4 cm were 0.922 {+-} 0.002 for contrast/saline solution and 0.808 {+-} 0.001 for contrast/air. The corresponding ratios by MC simulations were 0.895 {+-} 0.010 and 0.781 {+-} 0.010. The iodine concentration in the contrast was 23.3% by weight. The dose reduction of contrast-filled balloon ranges from 6% to 15% compared with water-filled balloon and 11% to 26% compared with air-filled balloon, with a balloon size range between 1.4 and 3.8 cm, and iodine concentration in contrast of 24.9%. The dose reduction was proportional to the contrast agent concentration. The gadolinium-based contrast agents showed less dose reduction because of much lower concentrations in their solutions. Conclusions: The dose to the posterior wall of the bladder and the anterior wall of the rectum can be reduced if the vaginal balloon is filled with contrast agent in comparison to vaginal balloons filled with saline solution or air.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Criteria for Determination of MC&A System Effectiveness

The Nevada Test Site (NTS) is a test bed for implementation of the Safeguards First Principles Initiative (SFPI), a risk-based approach to Material Control & Accountability (MC&A) requirements. The Comprehensive Assessment of Safeguards Strategies (COMPASS) model is used to determine the effectiveness of safeguards systems under SFPI. Under this model, MC&A is divided into nine primary elements. Each element is divided into sub-elements. Then, each sub-element is assigned two values, effectiveness and contribution, that are used to calculate the rating. Effectiveness is a measure of sub-element implementation and how well it meets requirements. Contribution is a relative measure of the importance, and functions as a weighting factor. The COMPASS model provides the methodology for calculation of element and subelement, but not the actual criteria. Each site must develop its own criteria. For the rating to be meaningful, the effectiveness criteria must be objective and based on explicit, measurable criteria. Contribution (weights) must reflect the importance within the MC&A program. This paper details the NTS approach to system effectiveness and contribution values, and will cover the following: the basis for the ratings, an explanation of the contribution weights, and the objective, performance-based effectiveness criteria. Finally, the evaluation process will be described.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Safeguards inventory and process monitoring regulatory comparison

Detecting the theft or diversion of the relatively small amount of fissile material needed to make a nuclear weapon given the normal operating capacity of many of today’s running nuclear production facilities is a difficult task. As throughput increases, the ability of the Material Control and Accountability (MC&A) Program to detect the material loss decreases because the statistical measurement uncertainty also increases. The challenge faced is the ability of current accounting, measurement, and material control programs to detect small yet significant losses under some regulatory approaches can decrease to the point where it is extremely low if not practically non-existent at normal operating capacities. Adding concern to this topic is that there are variations among regulatory bodies as far as what is considered a Significant Quantity (SQ). Some research suggests that thresholds should be lower than those found in any current regulation which if adopted would make meeting detection goals even more difficult. This paper reviews and compares the current regulatory requirements for the MA elements related to physical inventory, uncertainty of the Inventory Difference (ID), and Process Monitoring (PM) in the United States Department of Energy (DOE) and Nuclear Regulatory Commission (NRC), Rosatom of the Russian Federation and the Chinese Atomic Energy Agency (CAEA) of China. The comparison looks at how the regulatory requirements for the implementation of various MA elements perform across a range of operating capacities in example facilities.

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗

Measurement control workshop instructional materials

An essential element in an effective nuclear materials control and accountability (MC&A) program is the measurement of the nuclear material as it is received, moved, processed and shipped. Quality measurement systems and methodologies determine the accuracy of the accountability values. Implementation of a measurement control program is essential to ensure that the measurement systems and methodologies perform as expected. A measurement control program also allows for a determination of the level of confidence in the ac counting values.

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗

Measurement control workshop instructional materials

An essential element in an effective nuclear materials control and accountability (MC&A) program is the measurement of the nuclear material as it is received, moved, processed and shipped. Quality measurement systems and methodologies determine the accuracy of the accountability values. Implementation of a measurement control program is essential to ensure that the measurement systems and methodologies perform as expected. A measurement control program also allows for a determination of the level of confidence in the accounting values.

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗

Measurement control workshop instructional materials

A workshop to teach the essential elements of an effective nuclear materials control and accountability (MC&A) programs are outlined, along with the modes of Instruction, and the roles and responsibilities of participants in the workshop.