Search NASA⌕ Search

SEARCH · Search NASA

Results for “MEASURING INSTRUMENTS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

High-Speed and High-Power Ferroelectric Switching Current Measurement Instrument for Materials with Large Coercive Voltage and Remanent Polarization

A high-speed and high-power current measurement instrument is described for measuring rapid switching of ferroelectric samples with large spontaneous polarization and coercive field. Instrument capabilities (±200 V, 200 mA, and 200 ns order response) are validated with a LiTaO 3 single crystal whose switching kinetics are well known. The new instrument described here enables measurements that are not possible using existing commercial measurement systems, including the observation of ferroelectric switching in large coercive field and large spontaneous polarization Al 0.7 Sc 0.3 N thin films.

30 DIRECT ENERGY CONVERSION↗

Non-contact velocity measurement instruments and systems, and related methods

Methods for calibration of non-contact velocity measurements and systems for implementing the same are described. Generally, the method comprises inducing a shock wave into a sample at a stress intensity that varies across the sample's elastic limit, which corresponds to the elastic-plastic state transition of the sample. That transition state may be at the sample's Hugoniot elastic limit. The velocity of the sample is measured using a non-contact velocity measurement instrument such as a velocimeter. The measurement may be compared to a predicted velocity or a velocity measurement made by another system to determine calibration parameters.

47 OTHER INSTRUMENTATION↗

The fluctuation–dissipation measurement instrument at the Linac Coherent Light Source

The development of new modes at x-ray free electron lasers has inspired novel methods for studying fluctuations at different energies and timescales. For closely spaced x-ray pulses that can be varied on ultrafast time scales, we have constructed a pair of advanced instruments to conduct studies targeting quantum materials. We first describe a prototype instrument built to test the proof-of-principle of resonant magnetic scattering using ultrafast pulse pairs. This is followed by a description of a new endstation, the so-called fluctuation–dissipation measurement instrument, which was used to carry out studies with a fast area detector. In addition, we describe various types of diagnostics for single-shot contrast measurements, which can be used to normalize data on a pulse-by-pulse basis and calibrate pulse amplitude ratios, both of which are important for the study of fluctuations in materials. Furthermore, we present some new results using the instrument that demonstrates access to higher momentum resolution.

Assefa, T. A.↗

Qualification of Mitutoyo RA-2200 Roundness Tester Measuring Instrument for Clad Vent Set Cup Roundness and Flatness Inspections

Roundness (or circularity) and flatness measurements are made as part of the dimensional inspection process to certify that iridium alloy Clad Vent Set (CVS) cups meet the dimensional requirements of Iridium Alloy Cup Drawing M2D920101A005, Rev. 4 (see Figure 1). A Mahr Federal (Providence, RI) MarForm MMQ 400 Formtester is specified in the cup inspection Procedure GPHS-C-3624/25, Rev. 25 for roundness (dimension 16) and flatness (dimension 17). The Mahr Federal (Providence, RI) MarForm MMQ 400 Formtester stopped functioning in 2019. A new Mitutoyo RA-2200 Roundness Tester was purchased to replace the MMQ 400. Evaluations were conducted to qualify the new RA-2200 for CVS cup dimensional inspection work. The criterion for qualification was to ensure that the new RA-2200 instrument would yield roundness and flatness inspection results equivalent to or better than the predecessor MMQ 400 instrument.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

System and method for predicting the presence of rare earth elements

A system for predicting rare earth elements (REEs) in a feedstock sample includes a measurement instrument that records a measurement for a sample, a processor communicatively coupled to the measuring instrument, and a memory communicatively coupled to the processor and containing machine readable instructions that, when executed by the processor, cause the processor to correlate the measurement series using a model; and predict a presence of one or more rare earth element based at least in part on the correlation. A method for predicting rare earth elements includes measuring feedstock samples via XRF or PGNAA, to generate a measurements of elements of interest with a lower atomic weight than REEs; correlating the measurements with a model; and predicting a presence of one or more rare earth elements based at least in part on the correlation.

Fuka, Matthew↗

Steam Generators: Thermal Hydraulic Measurements and Instrumentation

Steam generators are integral components of both conventional and advanced reactors utilizing steam power cycles, as they influence the power conversion performance. Steam generator designs are highly influenced by the type of reactor coolant used, which mainly governs the different control, monitoring, and safety system actuation requirements. Therefore, the present work reviews the thermal hydraulics instrumentation within steam generators designed for pressurized water reactors (PWRs), high-temperature gas-cooled reactors (HTGRs), sodium fast reactors (SFRs), and molten salt cooled reactors (MSRs). Emphasis is given to measurement techniques that are either unique or particularly important to specific reactor types. Lastly, a discussion is provided on the instrumentation and measured parameters. The work identifies standard parameters of interest and is expected to aid the development of test beds and novel measurements techniques.

21 - SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLAN↗

Laboratory Measurements of Instrumental Signatures of the LSST Camera Focal Plane

Electro-optical testing and characterization of the Vera C. Rubin Observatory Legacy Survey of Space and Time (LSST) Camera focal plane, consisting of 205 charge-coupled devices (CCDs) arranged into 21 stand-alone Raft Tower Modules (RTMs) and 4 Corner Raft Tower Modules (CRTMs), is currently being performed at the SLAC National Accelerator Laboratory. Testing of the camera sensors is performed using a set of custom-built optical projectors, designed to illuminate the full focal plane or specific regions of the focal plane with a series of light illumination patterns: the crosstalk projector, the flat illuminator projector, and the spot grid projector. In addition to measurements of crosstalk, linearity and full well, the ability to project realistically-sized sources, using the spot grid projector, makes possible unique measurements of instrumental signatures such as deferred charge distortions, astrometric shifts due to sensor effects, and the brighter-fatter effect, prior to camera first light. Here we present the optical projector designs and usage, the electro-optical measurements and how these results have been used in testing and improving the LSST Camera instrumental signature removal algorithms.

79 ASTRONOMY AND ASTROPHYSICS↗

AmeriFlux Measurement Component Instrument Handbook

An AMC system was installed at the Atmospheric Radiation Measurement (ARM) Climate Research Facility’s North Slope Alaska (NSA) Barrow site, also known as NSA C1 at the ARM Data Archive, in August 2012. A second AMC system was installed at the third ARM Mobile Facility deployment at Oliktok Point, also known as NSA M1. This in situ system consists of 12 combination soil temperature and volumetric water content (VWC) reflectometers and one set of upwelling and downwelling PAR sensors, all deployed within the fetch of the Eddy Correlation Flux Measurement System. Soil temperature and VWC sensors placed at two depths (10 and 30 cm below the vegetation layer) at six locations (or microsites) allow soil property inhomogeneity to be monitored across a landscape. The soil VWC and temperature sensors used at NSA C1 are the Campbell Scientific CS650L and the sensors at NSA M1 use the Campbell Scientific CS655. The two sensors are nearly identical in function, and vendor specifications are based on the CS650 unless otherwise stated.

47 OTHER INSTRUMENTATION↗

Intercomparison of airborne and surface-based measurements during the CLARIFY, ORACLES and LASIC field experiments

Data are presented from intercomparisons between two research aircraft, the FAAM BAe-146 and the NASA Lockheed P3, and between the BAe-146 and the surface-based DOE (Department of Energy) ARM (Atmospheric Radiation Monitoring) Mobile Facility at Ascension Island (8 S, 14.5W, a remote island in the mid-Atlantic). These took place from 17 August to 5 September 2017, during the African biomass burning season. The primary motivation was to give confidence in the use of data from multiple platforms with which to evaluate numerical climate models. The three platforms were involved in the CLouds-Aerosol-Radiation Interaction and Forcing for Year 2017 (CLARIFY-2017), ObseRvations of Aerosols above CLouds and their intEractionS (ORACLES), and Layered Atlantic Smoke and Interactions with Clouds (LASIC) field experiments. Comparisons from flight segments on six days where the BAe-146 flew alongside the ARM facility on Ascension Island are presented, along with comparisons from wing-tip to wing-tip flight of the P3 and BAe-146 on 18 th August 2017. The intercomparison flight sampled a relatively clean atmosphere overlying a moderately polluted boundary layer, while the 6 fly-bys of the ARM site sampled both clean and polluted conditions 2–4 km upwind. We compare and validate characterisations of aerosol physical, chemical, and optical properties, atmospheric radiation, and cloud microphysics between platforms. We assess the performance of measurement instrumentation in the field, under conditions where sampling conditions are not tightly controlled as in laboratory measurements where calibrations are performed. Solar radiation measurements compared well between airborne platforms. Optical absorption coefficient measurements compared well across all three platforms, even though absolute magnitudes were often low (< 10 Mm -1 ) and close to the sensitivity limits of measurement instrumentation thereby confounding assessments of the comparability of absorption Ångström exponent characterisations. Aerosol absorption measurements from airborne platforms were more comparable than aircraft-to-ground observations. Scattering coefficient observations compared well between airborne platforms, but agreement with ground-based measurements was worse, potentially caused by small differences in sampling conditions or actual aerosol population differences. Chemical composition measurements followed a similar pattern, with better comparisons between the airborne platforms. Thermodynamics, aerosol, and cloud microphysical properties generally compared well.

54 ENVIRONMENTAL SCIENCES↗

In-situ, nanoscale fracture toughness measurements for improved mechanical interfaces

In this project, we demonstrated stable nanoscale fracture in single-crystal silicon using an in-situ wedge-loaded double cantilever beam (DCB) specimen. The fracture toughness KIC was calculated directly from instrumented measurement of force and displacement via finite element analysis with frictional corrections. Measurements on multiple test specimens were used to show K IC = 0.72 ± 0.07 MPa m 1/2 on {111} planes and observe the crack-growth resistance curve in <500 nm increments. The exquisite stability of crack growth, instrumented measurement of material response, and direct visual access to observe nanoscale fracture processes in an ideally brittle material differentiate this approach from prior DCB methods.

36 MATERIALS SCIENCE↗

Size resolved particle volatility for 30, 60, and 90 nm particles collected at the EPCAPE Mount Soledad site from 04/23/2023 to 06/15/2023

VTDMA GF-PDF: Growth factor probability density functions from the Gysel inversion are located here, where probability is out of 200. The instrument measured three different diameters 30 nm, 60nm and 90nm each diameter was selected for an hour. During that hour three different temperatures where scanned (40°C, 80°C, 160°C) in between each temperature a bypass scan was taken at room temperature. Each scan took 10-minutes and scanned growth factors from 0.2-1.2. Calibrations of the instrument with NaCl were performed on 4/26/2023 from 11:20 to 14:20, on 5/16/2023 from 11:40 to 16:00, and on 5/30/2023 from 10:20 to 14:20. Calibrations with (NH4)2SO4 were performed on 5/8/2023 from 11:45 to 14:40, on 5/23/2023 from 11:20 to 3:00, and on 6/14/2023 from 13:00 to 16:00. Time is recorded in seconds since 1/1/1904. GF_Vol_avg: Growth factor volume average calculated by the Gysel inversion. The instrument measured three different diameters 30 nm, 60nm and 90nm each diameter was selected for an hour. During that hour three different temperatures where scanned (40°C, 80°C, 160°C) in between each temperature a bypass scan was taken at room temperature. Each scan took 10-minutes and scanned growth factors from 0.2-1.2. Calibrations of the instrument with NaCl were performed on 4/26/2023 from 11:20 to 14:20, on 5/16/2023 from 11:40 to 16:00, and on 5/30/2023 from 10:20 to 14:20. Calibrations with (NH4)2SO4 were performed on 5/8/2023 from 11:45 to 14:40, on 5/23/2023 from 11:20 to 3:00, and on 6/14/2023 from 13:00 to 16:00. Time is recorded in seconds since 1/1/1904.

30nm growth factor volume average at 160C (GF_vol_↗

University of Louisiana at Lafayette

A partnership with the University of Louisiana and U.S. Department of Energy's National Renewable Energy Laboratory (NREL) to collect solar data to support future solar power generation in the United States. The measurement station monitors global, direct, and diffuse irradiance to define the amount of solar energy that hits this particular location. The solar measurement instrumentation is also accompanied by meteorological monitoring equipment to provide scientists with a complete picture of the solar power possibilities.

14 SOLAR ENERGY↗

University of Florida

A partnership with the University of Florida and U.S. Department of Energy's National Renewable Energy Laboratory (NREL) to collect solar data to support future solar power generation in the United States. The measurement station monitors global, direct, and diffuse irradiance to define the amount of solar energy that hits this particular location. The solar measurement instrumentation is also accompanied by meteorological monitoring equipment to provide scientists with a complete picture of the solar power possibilities.

14 SOLAR ENERGY↗

Photosynthetically Active Radiation (PAR) Instrument Handbook

Three photosynthetically active radiation (PAR) measurement instruments were deployed at the U.S. Department of Energy Atmospheric Radiation Measurement (ARM) User Facility’s Bankhead National Forest (BNF) observatory, installed on three different instrument towers within the forest. Each of the three instruments comprises an enclosure at the base of the tower, containing a datalogger and internal humidity sensor, connected to external PAR sensors mounted at various heights and vertical orientations on the same tower. PAR sensors measure radiation reaching the sensor with wavelengths from 400-700 nm, per unit area, per unit time, or the photosynthetic photon flux density (PPFD, µmol photons m -2 s -1 ). On the 43-meter tower of BNF supplemental site S10, sensors are located 43 m, 22 m, 10 m, and 5 m from ground level. Downwelling radiation is measured with upward-facing sensors at all heights, and upwelling radiation is measured with downward-facing sensors at 43 m and 5 m. On the two 10-m towers of BNF supplemental sites S13 and S14, upwelling radiation is measured at 8 m and 2 m, and downwelling radiation is measured at 8 m.

54 ENVIRONMENTAL SCIENCES↗