Search NASA⌕ Search

SEARCH · Search NASA

Results for “MEASURING SYSTEMS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Limitations in Advanced Measurement Systems: An Overview for Power Systems

Measurements have been an essential part of managing the electric power system from the beginning. Surprisingly, today’s measurements are not always particularly trustworthy. Countless factors can influence measurement in real-world conditions. In this report, we look at the measurement system as a comprehensive information acquisition system with complicated interdependencies setting the limiting factors and affecting system performance. The first chapter provides an overview of the whole system and introduces the key elements of the limitations checklist. The second part of the document is a component checklist for measurement system limitations that concisely describes effects, common remedies, and underlying factors.

42 ENGINEERING↗

Enhanced Dual Confocal Measurement System

A measurement instrument utilizing dual, chromatic, confocal, distance sensors has been jointly developed by General Atomics (GA) and Sandia National Laboratories (SNL) for thickness and flatness measurement of target components used in dynamic materials properties (DMP) experiments on the SNL Z-Machine (Z). Compared to previous methods used in production of these types of targets, the tool saves time and yields a 4x reduction in thickness uncertainty which is one of the largest sources of error in equation of state (EOS) measurements critical to supporting the NNSA’s Stockpile Stewardship program and computer modeling of high energy density experiments. It has numerous differences from earlier instruments operating on the dual confocal sensor principle to accommodate DMP components including larger lateral travel, longer working distance, ability to measure flatness in addition to thickness, built-in thickness calibration standards for quickly checking calibration before and after each measurement, and streamlined operation. Thickness and flatness of 0.2mm-3.3mm thick sections of diamond machined copper and aluminum can be measured to “sub-micron” accuracy. Sections up to 6mm thick can be measured with as-yet undermined accuracy. Furthermore, samples must have one surface which is flat to within 300µm, lateral dimensions of no more than 50mm x 50mm, and height less than 40mm.

36 MATERIALS SCIENCE↗

Demonstrate the Out-of-Pile Performance of a Real-Time Measurement System to Measure Thermal Conductivity Based on Photo Thermal Radiometry

SUMMARY The goal of this project is to develop a fiber-based instrument to perform in-reactor thermal conductivity measurements of fuels and materials. This instrument is based on photothermal radiometry (PTR) and involves heating a sample locally and measuring the induced temperature gradient by collecting blackbody radiation [2]. Thermal conductivity of the sample is extracted by comparing experimental results with a continuum-based model [3,4]. As a laser-based technique, PTR is a non-contact measurement technique that can be performed remotely and non-destructively. In addition, it has several advantages over other photothermal techniques, making it an ideal approach for in-situ measurement of thermal conductivity of nuclear fuels. Because blackbody radiation increases with emissivity and temperature, the PTR technique works well with unprepared surfaces, and measurement accuracy increases with temperature. Moreover, this approach is capable of measuring samples with irregular or poorly defined boundary conditions, which is a common situation for friable spent fuels.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Review of Prior U.S. Attribute Measurement Systems

Attribute Measurement Systems have been developed and demonstrated several times in the United States over the last decade or so; under the Trilateral Initiative (1996-2002), FMTTD (Fissile Material Transparency Technology Demonstration, 2000), and NG-AMS (Next Generation Attribute Measurement System, 2005-2008). Each Attribute Measurement System has contributed to the growing body of knowledge regarding the use of such systems in warhead dismantlement and other Arms Control scenarios. The Trilateral Initiative, besides developing prototype hardware/software, introduced the topic to the international community. The 'trilateral' parties included the United States, the Russian Federation, and the International Atomic Energy Agency (IAEA). With the participation of a Russian delegation, the FMTTD demonstrated that measurements behind an information barrier are feasible while meeting host party security requirements. The NG-AMS system explored the consequences of maximizing the use of Commercial off the Shelf (COTS) equipment, which made construction easier, but authentication harder. The 3rd Generation Attribute Measurement System (3G-AMS) will further the scope of previous systems by including additional attributes and more rigor in authentication.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Design and Validation of a High-Temperature Comparative Thermal-Conductivity Measurement System

A measurement system has been designed and built for the specific application of measuring the effective thermal conductivity of a composite, nuclear-fuel compact (small cylinder) over a temperature range of 100 C to 800 C. Because of the composite nature of the sample as well as the need to measure samples pre- and postirradiation, measurement must be performed on the whole compact non-destructively. No existing measurement system is capable of obtaining its thermal conductivity in a non-destructive manner. The designed apparatus is an adaptation of the guardedcomparative-longitudinal heat flow technique. The system uniquely demonstrates the use of a radiative heat sink to provide cooling which greatly simplifies the design and setup of such high-temperature systems. The design was aimed to measure thermalconductivity values covering the expected range of effective thermal conductivity of the composite nuclear fuel from 10W {center_dot} m{sup -1} {center_dot} K{sup -1} to 70W {center_dot} m{sup -1} {center_dot} K{sup -1}. Several materials having thermal conductivities covering this expected range have been measured for system validation, and results are presented. A comparison of the results has been made to data from existing literature.Additionally, an uncertainty analysis is presented finding an overall uncertainty in sample thermal conductivity to be 6%, matching well with the results of the validation samples.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Roadmap for Advanced Power System Measurements

Conditions in the electric power grid are changing rapidly. Changes are driven, in particular, by the increased penetration of renewable resources in the generation mix. Part of the solution to dealing with the changing conditions is the better use of measurement systems, taking advantage of the better understanding of measurements that was heralded by digital technology. Another part of the solution is the communication of samples of the directly observable voltages and currents by means of continuous point-on-wave values. The increased bandwidth capability of such a system allows more complicated measurement models to be built at the point of use. Additional measurements and analyses can then be performed. This Roadmap hinges on these two aspects of measuring: improved measurements supported by high-bandwidth (raw data) communications. Following an introduction to the overall subject, the report explores the impact of what can be thought of as the digital revolution in measurement. In essence, that revolution has served to clarify ideas about measurement and is continuing to lead to improved processes. An extensive survey of the relevant literature was performed . Webinars were held to learn from the wider community of practitioners. Based on this information, a number of gaps were identified whose continued existence would hamper the solution of the challenges now facing measurement and communication in the power grid. The underlying value propositions are interoperability (presently not very satisfactory in many measurements); greater (and less challenging) adoption of distributed energy resources; and improved international competitiveness. Underlying all that, of course, is progress toward a more reliable and resilient power system. The identified gaps were addressed in four major thrusts: technology deployment and demonstration, education, instrumentation testing and standards, and analytical methods. For each of the thrusts, multiple goals are defined to guide the implementation. The thrusts were designed to close gaps and unlock high-value use cases. After discussing the literature review, gap analysis, high-value use cases, and research thrusts in chapters 2-5, the report culminates in chapter 6 with a roadmap that links each aspect together to form a unified plan. Developing a research portfolio aligned with this plan will ensure that advanced measurement systems are in place to support reliable operation of the power system as it modernizes.

24 POWER TRANSMISSION AND DISTRIBUTION↗

High speed high dynamic range high accuracy measurement system

A measuring system includes an input that emulates a bandpass filter with no signal reflections. A directional coupler connected to the input passes the filtered input to electrically isolated measuring circuits. Each of the measuring circuits includes an amplifier that amplifies the signal through logarithmic functions. The output of the measuring system is an accurate high dynamic range measurement.

47 OTHER INSTRUMENTATION↗

Small bore magnetic measurement system, method for measuring small bore magnets

The invention provides a system for measuring magnets, the system comprising a guide tube removably received by a beam chamber tunnel, wherein said guide tube has a first end terminating at a first end of the tunnel and a second end terminating at a second end of the tunnel; a flexible substrate removably and slidably received by the tube, wherein the flexible substrate has a first end and a second end; a first rotary stage removably attached to the first end of said flexible substrate and a second rotary stage removably attached to the second end of said flexible substrate wherein the first rotary stage and the second rotary stage effects movement of the substrate through the tube; and a Hall probe supported by the flexible substrate. Also provided is a method for measuring magnetic fields, the method comprising extending a measuring probe into a magnetic core while maintaining the probe at ambient temperature and pressure.

Kasa, Matthew T.↗

Designing a 3rd generation, authenticatable attribute measurement system

Attribute measurement systems (AMS) are designed to measure potentially sensitive items containing Special Nuclear Materials to determine if the items possess attributes which fall within an agreed-upon range. Such systems could be used in a treaty to inspect and verify the identity of items in storage without revealing any sensitive information associated with the item. An AMS needs to satisfy two constraints: the host party needs to be sure that none of their sensitive information is released, while the inspecting party wants to have confidence that the limited amount of information they see accurately reflects the properties of the item being measured. The former involves 'certifying' the system and the latter 'authenticating' it. Previous work into designing and building AMS systems have focused more on the questions of certifiability than on the questions of authentication - although a few approaches have been investigated. The next step is to build a 3rd generation AMS which (1) makes the appropriate measurements, (2) can be certified, and (3) can be authenticated (the three generations). This paper will discuss the ideas, options, and process of producing a design for a 3rd generation AMS.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Natural Gas Fugitive Leak Detection Using an Unmanned Aerial Vehicle: Measurement System Description and Mass Balance Approach

Natural gas is an abundant resource across the United States, of which methane (CH4) is the main component. About 2% of extracted CH4 is lost through leaks. The Remote Methane Leak Detector (RMLD)-Unmanned Aerial Vehicle (UAV) system was developed to investigate natural gas fugitive leaks in this study. The system is composed of three major technologies: miniaturized RMLD (mini-RMLD) based on Backscatter Tunable Diode Laser Absorption Spectroscopy (TDLAS), an autonomous quadrotor UAV and simplified quantification and localization algorithms. With a miniaturized, downward-facing RMLD on a small UAV, the system measures the column-integrated CH4 mixing ratio and can semi-autonomously monitor CH4 leakage from sites associated with natural gas production, providing an advanced capability in detecting leaks at hard-to-access sites compared to traditional manual methods. Automated leak characterization algorithms combined with a wireless data link implement real-time leak quantification and reporting. This study placed particular emphasis on the RMLD-UAV system description and the quantification algorithm development based on a mass balance approach. Early data were gathered to test the prototype system and to evaluate the algorithm performance. The quantification algorithm derived in this study tended to underestimate the gas leak rates and yielded unreliable estimations in detecting leaks under 7 × 10 − 6 m3/s (~1 Standard Cubic Feet per Hour (SCFH)). Zero-leak cases can be ascertained via a skewness indicator, which is unique and promising. The influence of the systematic error was investigated by introducing simulated noises, of which Global Positioning System (GPS) noise presented the greatest impact on leak rate errors. The correlation between estimated leak rates and wind conditions were investigated, and steady winds with higher wind speeds were preferred to get better leak rate estimations, which was accurate to approximately 50% during several field trials. High precision coordinate information from the GPS, accurate wind measurements and preferred wind conditions, appropriate flight strategy and the relative steady survey height of the system are the crucial factors to optimize the leak rate estimations.

03 NATURAL GAS↗

The design and implementation of the AVNG measurement system

An attribute measurement system (AMS) measures a number of unclassified attributes of potentially classified material. By displaying these unclassified results only as red or green lights, the AMS protects potentially classified information while still generating confidence in the measurement result. The AVNG that we describe is an AMS built by RFNC-VNIIEF in Sarov, Russia. The AVNG detects neutron and gamma radiation signatures and displays the three unclassified attributes of 'plutonium presence,' 'plutonium mass >2 kg,' and 'plutonium isotopic ratio ({sup 240}Pu to {sup 239}Pu) < 0.1.' In this presentation, we will describe the design of the AVNG neutron and gamma detector subsystems, as well as the design of the entire AMS incorporating these detectors. We will also describe the construction of the AVNG and the final design that was demonstrated in June 2009.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Vertical Magnetic Measurement System Commis-sioning and First Measurements of the First Full-Length Prototype Quadrupole Magnet for the LHC Hi-Lumi Upgrade

This paper will report the commissioning of the vertical magnetic measurement system and the warm (room temperature) and cold (cryogenic) magnetic field measurements of the first full-length (4.2 m) quadrupole built by the US Accelerator Upgrade Project (AUP) project (formerly the LARP collaboration) for the high luminosity upgrade of the Large Hadron Collider at CERN. The magnet, designated MQXFAP2, is a prototype preceding production for the AUP Accelerator Upgrade Project (AUP). AUP will provide ten 8.4 m superconducting insertion region (IR) quadrupoles for the Hi-Lumi Upgrade. The 8.4 m quadrupoles will be built by assembling two 4.2 m magnets in a single cryostat. Agreement between BNL’s and LBNL’s warm measurement data has indicated that the upgraded vertical magnetic measurement system at BNL is ready for MQXFA magnet production testing. The cold magnetic measurement has been performed and preliminary data analysis has been conducted. The measured data indicates that the MQXFAP2 magnet has good magnetic field which meets the preliminary MQXFA magnet acceptance criteria.

43 PARTICLE ACCELERATORS↗

Torsional ultrasonic wave based level measurement system

A level measurement system suitable for use in a high temperature and pressure environment to measure the level of coolant fluid within the environment, the system including a volume of coolant fluid located in a coolant region of the high temperature and pressure environment and having a level therein; an ultrasonic waveguide blade that is positioned within the desired coolant region of the high temperature and pressure environment; a magnetostrictive electrical assembly located within the high temperature and pressure environment and configured to operate in the environment and cooperate with the waveguide blade to launch and receive ultrasonic waves; and an external signal processing system located outside of the high temperature and pressure environment and configured for communicating with the electrical assembly located within the high temperature and pressure environment.

47 OTHER INSTRUMENTATION↗

Systems Measures of Water Distribution System Resilience

Resilience is a concept that is being used increasingly to refer to the capacity of infrastructure systems to be prepared for and able to respond effectively and rapidly to hazardous events. In Section 2 of this report, drinking water hazards, resilience literature, and available resilience tools are presented. Broader definitions, attributes and methods for measuring resilience are presented in Section 3. In Section 4, quantitative systems performance measures for water distribution systems are presented. Finally, in Section 5, the performance measures and their relevance to measuring the resilience of water systems to hazards is discussed along with needed improvements to water distribution system modeling tools.

42 ENGINEERING↗

Mass measurement systems and related methods for measuring mass of solids within a liquid

A measurement system includes a vessel for containing a fluid and at least one solid material and a probe assembly for disposing partially into the fluid within the vessel. The probe assembly includes a hollow tube having an open lower longitudinal end and at least one pressure sensor within the hollow tube, the at least one pressure sensor configured to measure pressures of the fluid within the hollow tube at at least two different elevations. A method of measuring a mass of suspended solids within a fluid, the method includes receiving pressure measurements representing two different elevations of the fluid within a hollow tube and substantially free of the suspended solids and based at least partially on the received pressure measurements, determining a mass of the suspended solids.

Galbreth, Gregory G.↗

Effectively classically correlated state of a measured system and a bosonic measurement apparatus

We consider a multilevel system coupled to a bosonic measurement apparatus. We derive exact expressions for the time-dependent expectation values of a large class of physically relevant observables that depend on degrees of freedom of both systems. We find that, for this class, though the two systems become entangled as a result of their interaction, they appear classically correlated for long enough times. The unique corresponding time-dependent separable state is determined explicitly. To better understand the physical parameters that control the time scale of this effective disentanglement process, we study a one-dimensional measurement apparatus.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Framework for the assessment of PEMS (Portable Emissions Measurement Systems) uncertainty

Highlights: • Portable Emissions Measurement Systems (PEMS) are used to measure Real-Driving Emissions (RDE) of vehicles. • The uncertainty of PEMS was evaluated based on experimental data and technical requirements prescribed in the European regulation. • The 2017 uncertainty estimation was 43%. European regulation 2016/427 (the first package of the so-called Real-Driving Emissions (RDE) regulation) introduced on-road testing with Portable Emissions Measurement Systems (PEMS) to complement the chassis dynamometer laboratory (Type I) test for the type approval of light-duty vehicles in the European Union since September 2017. The Not-To-Exceed (NTE) limit for a pollutant is the Type I test limit multiplied by a conformity factor that includes a margin for the additional measurement uncertainty of PEMS relative to standard laboratory equipment. The variability of measured results related to RDE trip design, vehicle operating conditions, and data evaluation remain outside of the uncertainty margin. The margins have to be reviewed annually (recital 10 of regulation 2016/646). This paper lays out the framework used for the first review of the NO{sub x} margin, which is also applicable to future margin reviews. Based on experimental data received from the stakeholders of the RDE technical working group in 2017, two NO{sub x} margin scenarios of 0.24–0.43 were calculated, accounting for different assumptions of possible zero drift behaviour of the PEMS during the tests. The reduced uncertainty margin compared to the one foreseen for 2020 (0.5) reflects the technical improvement of PEMS over the past few years.

54 ENVIRONMENTAL SCIENCES↗