Search NASA⌕ Search

SEARCH · Search NASA

Results for “MECHANICAL HAND”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Mechanical hand for gripping objects

End effector serves as "hand" for remote manipulator spacecraft system to grasp objects of various sizes. Device has built in flexible wrist joint "cartilage" for increased gripping force without significant strain on mechanical connections.

Clark, K. H.↗

Three-Fingered Robot Hand

Mechanical joints and tendons resemble human hand. Robot hand has three "human-like" fingers. "Thumb" at top. Rounded tips of fingers covered with resilient material provides high friction for griping. Hand potential as prosthesis for humans.

Ruoff, C. F.↗

Anthropomorphic Telemanipulation System in Terminus Control Mode

This paper describes a prototype anthropomorphic kinesthetic telepresence system that is being developed at JPL. It utilizes dexterous terminus devices in the form of an exoskeleton force-sensing master glove worn by the operator and a replica four finger anthropomorphic slave hand. The newly developed master glove is integrated with our previously developed non-anthropomorphic six degree of freedom (DOF) universal force-reflecting hand controller (FRHC). The mechanical hand and forearm are mounted to an industrial robot (PUMA 560), replacing its standard forearm. The notion of 'terminus control mode' refers to the fact that only the terminus devices (glove and robot hand) are of anthropomorphic nature, and the master and slave arms are non-anthropomorphic. The system is currently being evaluated, focusing on tool handling and astronaut equivalent task executions. The evaluation revealed the system's potential for tool handling but it also became evident that hand tool manipulations and space operations require a dual arm robot. This paper describes the system's principal components, its control and computing architecture, discusses findings of the tool handling evaluation, and explains why common tool handling and EVA space tasks require dual arm robots.

glove exoskeleton force-sensing master glove EVA s↗

US-ROK Action Sheet 34: Safeguards Application of a Hand-held Mechanically Cooled Germanium Spectrometer

This report summarizes results of Action Sheet 34 - for the cooperative efforts on the field testing and evaluation of a high-resolution, hand-held, gamma-ray spectrometer, known as SPG (Spectroscopic Planar Germanium), for safeguards application such as short notice inspections, UF6 analysis, enrichment determination, and other potential applications. The Spectroscopic Planar Germanium (SPG) has been demonstrated IAEA Physical Inventory Verification (PIV) in South Korea. This field test was a success and the feedback provided by KINAC, IAEA, and national laboratory staff was used to direct efforts to improve the instrument this year. Key points in this report include measurement results from PIV, analysis of spectra with commercially available Ortec U235 and PC-FRAM, and completion of tripod and tungsten collimator and integration of user feedback.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Man-equivalent telepresence through four fingered human-like hand system

The author describes a newly developed mechanical hand system. The robot hand is in human-like configuration with a thumb and three fingers, a palm, a wrist, and the forearm in which the hand and wrist actuators are located. Each finger and the wrist has its own active electromechanical compliance system, allowing the joint drive trains to be stiffened or loosened. This mechanism imitates the human muscle dual function of positioner and stiffness controller. This is essential for soft grappling operations. The hand-wrist assembly has 16 finger joints, three wrist joints, and five compliance mechanisms for a total of 24 degrees of freedom. The strength of the hand is roughly half that of the human hand and its size is comparable to a male hand. The hand is controlled through an exoskeleton glove controller that the operator wears. The glove provides the man-machine interface in telemanipulation control mode: it senses the operator's inputs to guide the mechanical hand in hybrid position and force control. The hand system is intended for dexterous manipulations in structured environments. Typical applications will include work in hostile environment such as space operations and nuclear power plants.

Jau, Bruno M.↗

A Hand-Off Mechanism for Primosome Assembly in Replication Restart

Collapsed DNA replication forks must be reactivated through origin-independent reloading of the replication machinery (replisome) to ensure complete duplication of cellular genomes. In E. coli, the PriA-dependent pathway is the major replication restart mechanism and requires primosome proteins PriA, PriB, and DnaT for replisome reloading. However, the molecular mechanisms that regulate origin-independent replisome loading are not fully understood. Here, we demonstrate that assembly of primosome protein complexes represents a key regulatory mechanism, as inherently weak PriA-PriB and PriB-DnaT interactions are strongly stimulated by single-stranded DNA. Furthermore, the binding site on PriB for single-stranded DNA partially overlaps the binding sites for PriA and DnaT, suggesting a dynamic primosome assembly process in which single-stranded DNA is handed off from one primosome protein to another as a repaired replication fork is reactivated. This model helps explain how origin-independent initiation of DNA replication is restricted to repaired replication forks, preventing overreplication of the genome.

59 BASIC BIOLOGICAL SCIENCES↗

Hand-held, mechanically cooled, radiation detection system for gamma-ray spectroscopy

In one embodiment, a radiation detection system is provided including a radiation detector and a first enclosure encapsulating the radiation detector, the first enclosure including a low-emissivity infra-red (IR) reflective coating used to thermally isolate the radiation detector. Additionally, a second enclosure encapsulating the first enclosure is included, the first enclosure being suspension mounted to the second enclosure. Further, a cooler capable of cooling the radiation detector is included. Still yet, a first cooling interface positioned on the second enclosure is included for coupling the cooler and the first enclosure. Furthermore, a second cooling interface positioned on the second enclosure and capable of coupling the first enclosure to a cooler separate from the radiation detection system is included. Other embodiments are also presented.

36 MATERIALS SCIENCE↗

Design for a three-fingered hand

This paper describes the construction of a prototype mechanical hand or 'end effector' for use on a remotely controlled robot, but with possible application as a prosthetic device. An analysis of hand motions is reported, from which it is concluded that the two most important manipulations (apart from grasps) are to be able to pick up a tool and draw it into a nested grip against the palm, and to be able to hold a pistol-grip tool such as an electric drill and pull the trigger. One of our models was tested and found capable of both these operations.

Crossley, F. R. E.↗

Integrated multi-sensory control of space robot hand

Dexterous manipulation of a robot hand requires the use of multiple sensors integrated into the mechanical hand under distributed microcomputer control. Where space applications such as construction, assembly, servicing and repair tasks are desired of smart robot arms and robot hands, several critical drives influence the design, engineering and integration of such an electromechanical hand. This paper describes a smart robot hand developed at the Jet Propulsion Laboratory for experimental use and evaluation with the Protoflight Manipulator Arm (PFMA) at the Marshall Space Flight Center (MSFC).

Bejczy, A. K.↗

Direct-Link Prehensor

Operator-powered mechanical hand gives protection, dexterity, and proximity to work. Prehensor has ring finger, index finger, and thumb, mounted on supporting frame. Ring and index fingers consist of three jointed links each, and thumb consists of two jointed links. Thumb positioned opposite fingers in anthropomorphic arrangement. Palm assistor (disk projecting from support frame) helps mechanical fingers to hold objects. Shroud encloses operator's hand, protecting it from vacuum, high pressure, or hazardous materials. External mechanical fingers made of materials compatible with external environment.

Jameson, John W.↗

Two-Thumbed Robot Hand

Robot hand includes thumblike members on left and right sides and fingerlike member at middle. Configuration of digits enables hand to adapt to variously shaped objects, grasp them robustly and reliably, and manipulate them. Reduces complexity of control mechanisms and provides kinesthetic perception of shapes of grasped objects. Mechanical hand with two thumbs and middle finger made from commercially available components. With specially designed dc motors and assemblies of gears, size of hand reduced considerably. Suited to handling objects in industrial tasks.

Lee, Sukhan↗

Mechanical Behavior of High-Entropy Alloys: A Review

High-entropy alloys (HEAs) are materials that consist of equimolar or near-equimolar multiple principal components but tend to form single phases, which is a new research topic in the field of metallurgy, and have attracted extensive attention in the past decade. The HEAs families contain the face-centered-cubic (fcc), body-centered-cubic (bcc), and hexagonal-close-packed (hcp)-structured HEAs. On the one hand, mechanical properties, e.g., hardness, strength, ductility, fatigue, and elastic moduli, are essential for practical applications of HEAs. Scientists have explored in this direction since the advent of HEAs. On the other hand, the pursuit of high strength and good plasticity is the critical research issue of materials. Hence, strengthening of HEAs is a crucial issue.In this chapter, we reviewed the recent work on the room-temperature elastic properties and mechanical behavior of HEAs, including the mechanisms behind the plastic deformation of HEAs at both low and high temperatures. Furthermore, the present work examined the strengthening strategies of HEAs, e.g., strain hardening, grain-boundary strengthening, solid-solution strengthening, and particle strengthening. The fatigue, creep, and fracture properties were briefly introduced. Lastly, the future scientific issues and challenges of HEAs were discussed.

Shang, Yuanyuan↗

Multiplexing core & sheath extrusion system development for additive manufacturing for inner-bead multi-material capability

Single-feed polymer extruders are widely used in large-format additive manufacturing (AM) systems; however, the increasing demand for multi-material functionality within a single part has driven significant innovation in this field. One approach involves robotic pick-and-place operations, while another explores mechanical switching of feed lines during extrusion. Although robotic pick-and-drop systems offer flexibility, they introduce longer layer times during material changes, which can negatively affect the structural integrity of the part. On the other hand, mechanical feed switching causes delays in material transitions, as the existing material must be flushed before the new material emerges from the nozzle. This poses particular challenges for smaller or more intricate parts. In this study we are developing a unique multiplexing extrusion system with core & sheath nozzle that combines two extruders via co-extrusion. This allows for a unique inside and outside inner-bead (i.e., within the same bead) multi-material capability. We believe that this technology will allow for combining neat and filled materials, ductile and stronger materials, and many other combinations to address the problems aforementioned above and disrupt the AM technology creating new opportunities and opening application areas.

Tekinalp, Halil [ORNL]↗

A DNA packaging motor inchworms along one strand allowing it to adapt to alternative double-helical structures

Abstract Ring ATPases that translocate disordered polymers possess lock-washer architectures that they impose on their substrates during transport via a hand-over-hand mechanism. Here, we investigate the operation of ring motors that transport ordered, helical substrates, such as the bacteriophage ϕ29 dsDNA packaging motor. This pentameric motor alternates between an ATP loading dwell and a hydrolysis burst wherein it packages one turn of DNA in four steps. When challenged with DNA-RNA hybrids and dsRNA, the motor matches its burst to the shorter helical pitches, keeping three power strokes invariant while shortening the fourth. Intermittently, the motor loses grip on the RNA-containing substrates, indicating that it makes optimal load-bearing contacts with dsDNA. To rationalize these observations, we propose a helical inchworm translocation mechanism in which, during each cycle, the motor increasingly adopts a lock-washer structure during the ATP loading dwell and successively regains its planar form with each power stroke during the burst.

59 BASIC BIOLOGICAL SCIENCES↗

Active conformation of the p97-p47 unfoldase complex

The p97 AAA+ATPase is an essential and abundant regulator of protein homeostasis that plays a central role in unfolding ubiquitylated substrates. Here we report two cryo-EM structures of human p97 in complex with its p47 adaptor. One of the conformations is six-fold symmetric, corresponds to previously reported structures of p97, and lacks bound substrate. The other structure adopts a helical conformation, displays substrate running in an extended conformation through the pore of the p97 hexamer, and resembles structures reported for other AAA unfoldases. These findings support the model that p97 utilizes a “hand-over-hand” mechanism in which two residues of the substrate are translocated for hydrolysis of two ATPs, one in each of the two p97 AAA ATPase rings. Proteomics analysis supports the model that one p97 complex can bind multiple substrate adaptors or binding partners, and can process substrates with multiple types of ubiquitin modification.

59 BASIC BIOLOGICAL SCIENCES↗

Biochemical physics modeling of biological nano-motors

We present a biochemical physics model accounting for the dynamics and energetics of both translational and rotational protein motors. A modified version of the hand-over-hand mechanism considering competitive inhibition by ADP is presented. Transition state-like theory is used to reconstruct the time dependent free-energy landscape of the cycle catalyst process that allows to predicting the number of steps or rotations that a single motor can perform. In addition, following the usual approach of chemical kinetics, we calculate the average translational velocity and also the stopping time of processes involving a collectivity of motors, such as exocytosis and endocytosis processes. Finally, we formulate a stochastic model reproducing very well single realizations of kinesin and rotary ATPases.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗