MO-F-16A-08: Have An Impact On More Patients From Your Ideas And Inventions

Purpose: To inform physicists how to obtain an FDA 510(k) clearance for the innovations they use in their facility and to make those ideas widely available to patients throughout the U.S. Methods: Give advice from 20 years experience of assisting in well over 100 successful 510(k) clearances. Results: Learn how to develop a 510(k) submission. Conclusion: Many physicists, physicians and radiation therapists have developed innovations that that are helpful to the patients in their institution. But, many of these innovations deserve to be made available to patients throughout the United States. The author, a Certified Radiological Physicist and former FDA employee, has consulted for over twenty years for inventors, start-ups and established medical device manufacturers to bring new devices to market in the U.S. and to assist them to established FDA compliant quality systems for manufacturing. In this presentation the audience will learn the important points for deciding to go forward with obtaining a Premarket Notification clearance [also known as a 510(k) clearance] to legally market a medical device in the United States. The FDA has published guidelines for submitting a 510(k) application. However, the methods used to efficiently develop the documentation for submission and to obtain clearance in the shortest possible time comes from the author's experience in assisting well over one hundred successful 510(k) clearances.Whether you want to start your own company or to market your idea to an established medical device manufacturer, the value of your innovation increases with a documented 510(k) clearance from FDA.

61 RADIATION PROTECTION AND DOSIMETRY↗

ACTS Satellite Telemammography Network Experiments

The Satellite Networks and Architectures Branch of NASA's Glenn Research Center has developed and demonstrated several advanced satellite communications technologies through the Advanced Communications Technology Satellite (ACTS) program. One of these technologies is the implementation of a Satellite Telemammography Network (STN) encompassing NASA Glenn, the Cleveland Clinic Foundation. the University of Virginia, and the Ashtabula County Medical Center. This paper will present a look at the STN from its beginnings to the impact it may have on future telemedicine applications. Results obtained using the experimental ACTS satellite demonstrate the feasibility of Satellite Telemammography. These results have improved teleradiology processes and mammography image manipulation, and enabled advances in remote screening methodologies. Future implementation of satellite telemammography using next generation commercial satellite networks will be explored. In addition, the technical aspects of the project will be discussed, in particular how the project has evolved from using NASA developed hardware and software to commercial off the shelf (COTS) products. Development of asymmetrical link technologies was an outcome of this work. Improvements in the display of digital mammographic images, better understanding of end-to-end system requirements, and advances in radiological image compression were achieved as a result of the research. Finally, rigorous clinical medical studies are required for new technologies such as digital satellite telemammography to gain acceptance in the medical establishment. These experiments produced data that were useful in two key medical studies that addressed the diagnostic accuracy of compressed satellite transmitted digital mammography images. The results of these studies will also be discussed.

Kachmar, Brian A.↗

Exploration Medical Capability System Engineering Introduction and Vision

Human exploration missions to beyond low Earth orbit destinations such as Mars will require more autonomous capability compared to current low Earth orbit operations. For the medical system, lack of consumable resupply, evacuation opportunities, and real-time ground support are key drivers toward greater autonomy. Recognition of the limited mission and vehicle resources available to carry out exploration missions motivates the Exploration Medical Capability (ExMC) Element's approach to enabling the necessary autonomy. The Element's work must integrate with the overall exploration mission and vehicle design efforts to successfully provide exploration medical capabilities. ExMC is applying systems engineering principles and practices to accomplish its integrative goals. This talk will briefly introduce the discipline of systems engineering and key points in its application to exploration medical capability development. It will elucidate technical medical system needs to be met by the systems engineering work, and the structured and integrative science and engineering approach to satisfying those needs, including the development of shared mental and qualitative models within and external to the human health and performance community. These efforts are underway to ensure relevancy to exploration system maturation and to establish medical system development that is collaborative with vehicle and mission design and engineering efforts.

Mindock, J.↗

Flight Surgeon Survey Results Review: Long-Duration Artemis Medical System ConOps

Background: The Artemis Mission Functional Medical Concept of Operation (ConOp) is an operational document that describes the functional medical capabilities and concept of operations for early Artemis missions of around 30 days duration. It is currently under revision for longer missions (180+ days), aiming to build a foundational diagnostic and treatment capabilities list considering mission parameters, crew selection and training, and mass/volume constraints. An interview of NASA operational flight surgeons was completed to start the revision of the medical ConOp. Methods: In the survey, 20 experienced NASA flight surgeons responded to 57 standardized questions covering 17 categories, 22 questions of which were covered in this analysis including 4 categories: Cardiovascular, Catastrophic Situations, Pulmonary, and Respiratory/O2 Support. These results were categorized into recommendations and observations. The recommendations were used to objectively quantify the responses to look for consensus, differences and uncertainty among responses. The observations remain important but were not included in this review. Analysis: Regarding questions related to changes in medical conditions treated for long-duration missions, percentage of “No Change” responses varied from 20% to 75%. In the “Change” treatment plan responses, a variety of recommendations were made, which were further made into graphics for better illustration. Additionally, recommendations on capability questions in multiple systems were visualized altogether in one product. Discussion: This work demonstrates the importance of collaboration and thorough analysis amongst experienced NASA flight surgeons for helping establish medical systems and contributing to the likelihood of mission success during Artemis long-duration missions. Through this review, we were able to identify some positive attributes as well as areas for improvement, which will facilitate further discussions.

Andrew Bushong↗

Beryllium Health and Safety Committee Data Reporting Task Force White Paper #2 -- Uses of Uncensored Data

On December 8, 1999, the Department of Energy (DOE) published Title 10 CFR 850 (hereafter referred to as the Rule) to establish a chronic beryllium disease prevention program (CBDPP) to: (1) reduce the number of workers currently exposed to beryllium in the course of their work at DOE facilities managed by DOE or its contractors; (2) minimize the levels of, and potential for, exposure to beryllium; and (3) establish medical surveillance requirements to ensure early detection of the disease. On January 4, 2001, DOE issued DOE G 440.1-7A, Implementation Guide for use with 10 CFR 850, Chronic Beryllium Disease Prevention Program, to assist line managers in meeting their responsibilities for implementing the CBDPP. That guide describes methods and techniques that DOE considers acceptable in complying with the Rule. In 2005 a draft DOE Technical Standard ''Management of Items and Areas Containing Low Levels of Beryllium'' (SAFT 0103; hereafter referred to as the ''TS'') was circulated for comment (http://www.hss.energy.gov/NuclearSafety/techstds/tsdrafts/saft-0103.pdf). DOE technical standards are voluntary consensus standards developed when industry standards do not exist (see http://www.hss.energy.gov/NuclearSafety/techstds/index.html for more information). DOE does not require its field elements to implement DOE technical standards, but field elements may choose to adopt these standards to meet specific needs. This beryllium TS is intended to provide best practices and lessons learned for manageing items and areas that contain low levels of beryllium, which has been a costly and technically challenging component of CBDPPs. The TS is also intended to provide guidance for determining if the Rule's housekeeping and release criteria are met. On challenge the TS addressed was the statistical interpretation of data sets with non-detected results, a topic for which no strong consensus exists. Among the many comments on the draft TS was a suggestion that certain of the statistical comparisons described in the TS could be better implemented if analytical results, even when below a reporting limit, were to be reported by analytical laboratories. See Appendix 1 for a review of terminology related to reporting limits. The Beryllium Health and Safety Committee (BHSC) formed a Sampling and Analysis Subcommittee (SAS) in 2003. The SAS established a working group on accreditation and reporting limits. By 2006 it had become evident that the issues extended to data reporting as a whole. The SAS proposed to the BHSC the formation of a Data Reporting Task Force (DRTF) to consider issues related to data reporting. The BHSC Board agreed, and requested that the DRTF generate a white paper, to be offered by the BHSC to potential interested parties such as the DOE policy office that is responsible for beryllium health and safety policy. It was noted that additional products could include detailed guidance and potentially a journal article in the future. The SAS proposed that DRTF membership represent the affected disciplines (chemists, industrial hygiene professionals and statisticians, and the DOE office that is responsible for beryllium health and safety policy). The BHSC Board decided that DRTF membership should come from DOE sites, since the focus would be on reporting in the context of the TS and the Rule. The DRTF came into existence in late 2006. The DRTF membership includes industrial hygienists, analytical chemists and laboratory managers, members of the regulatory and oversight community, and environmental statisticians. A first White Paper, ''Summary of Issues and Path Forward'', was reviewed by the BHSC in March 2007 and issued by the DRTF in June 2007. It describes the charter of the DRTF, introduces some basic terminology (reproduced here in Appendix 1), lays out the issues the DRTF is expected to address, and describes a path forward for the DRTF's work. This first White Paper is available through the BHSC web site. This White Paper presents recommendations developed by the DRTF following the process laid out in that first White Paper.

99 GENERAL AND MISCELLANEOUS↗

Comparison of extracolonic findings and clinical outcomes in a screening and diagnostic CT colonography population

Purpose: To compare the distribution of extracolonic findings and clinical outcomes between screening and diagnostic CT colonography (CTC) populations. Methods: 388 consecutive patients (369 men, 19 women; mean ± SD age 67.8 ± 10 years) who underwent first-time CTC (4/2011–4/2017) at a Veteran’s Affairs Medical Center were divided into screening (asymptomatic) or diagnostic (symptomatic) cohorts based on CTC indication. CTC reporting and data system E-scores for extracolonic findings were retrospectively assigned based on prospective CTC radiologic reports. Multinomial logistic regression was used to examine the association between E-scores and CTC indication. Electronic medical records of all patients with E3 or E4 scores were reviewed (median follow-up 2.8 years) to determine clinical outcomes. Results: 68% (262/388) underwent screening and 32% (126/388) diagnostic CTC. 7.2% (28/388) had extracolonic findings considered potentially significant (E4), 4.4% (17/388) had indeterminate but likely unimportant findings (E3), and 88.4% (347/388) had normal or unimportant findings (E1 or E2). E-scores were not significantly different between screening and diagnostic CTC when adjusted for age, gender, and prior imaging (p = 0.44). 4.6% (12/262) of patients with E3/E4 findings in the screening cohort demonstrated clinically significant outcomes, compared with 4.0% (5/126) in the diagnostic cohort, including a total of three extracolonic malignancies (0.8%) and three abdominal aortic aneurysms (0.8%). 4.6% (18/388) underwent follow-up imaging studies to confirm a benign outcome after detection of a category E3/E4 finding. Conclusions: The distribution of extracolonic findings and clinical outcomes were not statistically significantly different between screening and diagnostic CTC populations.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Median Arcuate Ligament Syndrome: A Single-Center Experience with 23 Patients

BackgroundMedian arcuate ligament syndrome (MALS) is a rare entity that occurs when the median arcuate ligament of the diaphragm is low-lying, causing a compression to the underlying celiac trunk. We reviewed the vascular changes associated with MALS in an effort to emphasize the seriousness of this disease and the complications that may result.MethodsThis is a retrospective descriptive analysis of 23 consecutive patients diagnosed with MALS between January 1, 2012 and December 31, 2015 at a tertiary medical center. Computed tomographic (CT) scans, medical records, and patient follow-up were reviewed.ResultsThe number of patients included herein was 23. The median age was 56 years (17–83). Sixteen patients (69.6%) had a significant arterial collateral circulation. Eleven patients (47.8%) were found to have visceral artery aneurysms; 4 patients (36.4%) bled secondary to aneurysm rupture. All ruptured aneurysms were treated with endovascular approach. The severity of the hemodynamic changes appears to be greater with complete occlusion,ConclusionsMALS causes pathological hemodynamic changes within the abdominal vasculature. Follow-up is advised for patients who develop a collateral circulation. Resulting aneurysms should preferably be treated when the size ratio approaches three. Treatment of these aneurysms can be done via an endovascular approach coupled with possible celiac artery decompression to restore physiologic blood flow.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Clinical solid waste management practices and its impact on human health and environment - A review

Research highlights: > Appropriate waste management technology for safe handling and disposal of clinical solid waste. > Infectious risk assessment on unsafe handling of clinical solid waste. > Recycling-reuse program of clinical solid waste materials. > Effective sterilization technology to reduce exposure of infectious risk. - Abstract: The management of clinical solid waste (CSW) continues to be a major challenge, particularly, in most healthcare facilities of the developing world. Poor conduct and inappropriate disposal methods exercised during handling and disposal of CSW is increasing significant health hazards and environmental pollution due to the infectious nature of the waste. This article summarises a literature review into existing CSW management practices in the healthcare centers. The information gathered in this paper has been derived from the desk study of open literature survey. Numerous researches have been conducted on the management of CSW. Although, significant steps have been taken on matters related to safe handling and disposal of the clinical waste, but improper management practice is evident from the point of initial collection to the final disposal. In most cases, the main reasons of the mismanagement of CSW are the lack of appropriate legislation, lack of specialized clinical staffs, lack of awareness and effective control. Furthermore, most of the healthcare centers of the developing world have faced financial difficulties and therefore looking for cost effective disposal methods of clinical waste. This paper emphasizes to continue the recycle-reuse program of CSW materials after sterilization by using supercritical fluid carbon dioxide (SF-CO2) sterilization technology at the point of initial collection. Emphasis is on the priority to inactivate the infectious micro-organisms in CSW. In that case, waste would not pose any threat to healthcare workers. The recycling-reuse program would be carried out successfully with the non-specialized clinical staffs. Therefore, the adoption of SF-CO2 sterilization technology in management of clinical solid waste can reduce exposure to infectious waste, decrease labor, lower costs, and yield better compliance with regulatory. Thus healthcare facilities can both save money and provide a safe environment for patients, healthcare staffs and clinical staffs.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Radiotherapy and Nuclear Medicine Project for an Integral Oncology Center at the Oaxaca High Specialization Regional Hospital

A building project of Radiotherapy and Nuclear Medicine services (diagnostic and therapy), within an Integral Oncology Center (IOC), requires interdisciplinary participation of architects, biomedical engineers, radiation oncologists and medical physicists. This report focus on the medical physicist role in designing, building and commissioning stages, for the final clinical use of an IOC at the Oaxaca High Specialization Regional Hospital (HRAEO). As a first step, during design stage, the medical physicist participates in discussions about radiation safety and regulatory requirements for the National Regulatory Agency (called CNSNS in Mexico). Medical physicists propose solutions to clinical needs and take decisions about installing medical equipment, in order to fulfill technical and medical requirements. As a second step, during the construction stage, medical physicists keep an eye on building materials and structural specifications. Meanwhile, regulatory documentation must be sent to CNSNS. This documentation compiles information about medical equipment, radioactivity facility, radiation workers and nuclear material data, in order to obtain the license for the linear accelerator, brachytherapy and nuclear medicine facilities. As a final step, after equipment installation, the commissioning stage takes place. As the conclusion, we show that medical physicists are essentials in order to fulfill with Mexican regulatory requirements in medical facilities.

07 ISOTOPE AND RADIATION SOURCES↗

SU-E-T-569: Neutron Shielding Calculation Using Analytical and Multi-Monte Carlo Method for Proton Therapy Facility

Purpose: To evaluate the shielding wall design to protect patients, staff and member of the general public for secondary neutron using a simply analytic solution, multi-Monte Carlo code MCNPX, ANISN and FLUKA. Methods: An analytical and multi-Monte Carlo method were calculated for proton facility (Sumitomo Heavy Industry Ltd.) at Samsung Medical Center in Korea. The NCRP-144 analytical evaluation methods, which produced conservative estimates on the dose equivalent values for the shielding, were used for analytical evaluations. Then, the radiation transport was simulated with the multi-Monte Carlo code. The neutron dose at evaluation point is got by the value using the production of the simulation value and the neutron dose coefficient introduced in ICRP-74. Results: The evaluation points of accelerator control room and control room entrance are mainly influenced by the point of the proton beam loss. So the neutron dose equivalent of accelerator control room for evaluation point is 0.651, 1.530, 0.912, 0.943 mSv/yr and the entrance of cyclotron room is 0.465, 0.790, 0.522, 0.453 mSv/yr with calculation by the method of NCRP-144 formalism, ANISN, FLUKA and MCNP, respectively. The most of Result of MCNPX and FLUKA using the complicated geometry showed smaller values than Result of ANISN. Conclusion: The neutron shielding for a proton therapy facility has been evaluated by the analytic model and multi-Monte Carlo methods. We confirmed that the setting of shielding was located in well accessible area to people when the proton facility is operated.

61 RADIATION PROTECTION AND DOSIMETRY↗

MIRD Dose Estimate Report No. 20: Radiation Absorbed-Dose Estimates for 111In- and 90Y-Ibritumomab Tiuxetan

Absorbed dose calculations provide a scientific basis for evaluating the biological effects associated with administered radiopharmaceuticals. In cancer therapy, radiation dosimetry also supports treatment planning, dose-response analyses, predictions of therapy effectiveness, and completeness of patient medical records. In this study, we evaluated the organ radiation absorbed doses resulting from intravenously administered 111In- and 90Y-Ibritumomab Tiuxetan (Zevalin). Methods: Ten patients (six male, four female) with non-Hodgkin’s lymphoma, cared for at three different medical centers, were administered tracer 111In-Ibritumomab Tiuxetan and were assessed using planar scintillation camera imaging at five time points, blood clearance measurements, and CT-organ volumetrics, to determine patient-specific organ biokinetics and dosimetry. Explicit attenuation correction based on transmission scan or transmission measurements provided the fraction of 111In administered activity in seven major organs, the whole body, and remainder tissues over time through complete decay. Activity-time curves were constructed, and radiation doses were calculated using MIRD methods and implementing software (OLINDA-EXM). Results: Mean radiation absorbed doses in 10 cancer patients for 111In- and for 90-Y-Ibritumomab Tiuxetan are reported for 24 organs and the whole body. Biological uptake and retention data are given for seven major source organs, remainder tissues, and the whole body. Median absorbed dose values calculated by this method were compared to previously published dosimetry for Zevalin and the product package insert. Conclusions: Careful dosimetry techniques provide useful information on absorbed dose from administered radiopharmaceuticals in patients. The importance of patient-specific dosimetry emerges in high-dose radioimmunotherapy when the objective of treatment planning is to achieve disease cures safely by limiting radiation doses to any critical normal organ to a maximum tolerable value.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

A review of the influence of physical condition parameters on a typical aerospace stress effect: Decompression sickness

The study examines data on episodes of decompression sickness, particularly from recent Navy work in which the event occurred under multiple stress conditions, to determine the extent to which decompression sickness might be predicted on the basis of personal characteristics such as age, weight, and physical condition. Such information should ultimately be useful for establishing medical selection criteria to screen individuals prior to participation inactivities involving extensive changes in ambient pressure, including those encountered in space operations. The main conclusions were as follows. There is a definite and positive relationship between increasing age and weight and the likelihood of decompression sickness. However, for predictive purposes, the relationship is low. To reduce the risk of bends, particularly for older individuals, strenuous exercise should be avoided immediately after ambient pressure changes. Temperatures should be kept at the low end of the comfort zone. For space activities, pressure changes of over 6-7 psi should be avoided. Prospective participants in future missions such as the Space Shuttle should not be excluded on the basis of age, certainly to age 60, if their general condition is reasonably good and they are not grossly obese. (Modified author abstract)

West, V. R.↗

Clinical aspects of telemedicine

Communication among physicians is an essential in order to combine our experiences for the elucidation and application of new knowledge and for the accurate and uniform application of established medical practice. This communication requires an adequate understanding of the culture of the patient and the social context of disease and indeed the culture of the physician. Malnutrition in Bangladesh means caloric insufficiency, and a program to lower cholesterol would be impertinent, while a program to enhance the nutrition of patients in Texas by an international effort to import more grain would be ludicrous. In the same vein a public health effort to combat alcoholic cirrhosis in Mecca would be as silly as a program to increase fiber in the diet of the Bantu. Clinical communication must acknowledge the culture of the issue at hand and the differences in the experiential base of the physicians. Not only do geography and culture affect the potential differences in the experiential bases, but the world utilizes very different traditions of education and science in training physicians. We are influenced by the diseases we treat, and learn to look for the expected at least as much as we are attentive to the unexpected. A physician in Siberia would be much more likely to recognize frostbite than one from Buenos Aires, and the Argentine doctor would much more likely consider Chaga's Disease to explain abdominal pain than a colleague in Zurich. Beyond these obvious issues in communication among physicians we must deal with the many languages and idioms used in the world. An overview of using Telemedicine SpaceBridge after the earthquake in the Republic of Armenia in 1988 is presented.

Merrell, Ronald C.↗

Establishing advanced practice for medical imaging in New Zealand

Introduction: This article presents the outcome and recommendations following the second stage of a role development project conducted on behalf of the New Zealand Institute of Medical Radiation Technology (NZIMRT). The study sought to support the development of profiles and criteria that may be used to formulate Advanced Scopes of Practice for the profession. It commenced in 2011, following on from initial research that occurred between 2005 and 2008 investigating role development and a possible career structure for medical radiation technologists (MRTs) in New Zealand (NZ). Methods: The study sought to support the development of profiles and criteria that could be used to develop Advanced Scopes of Practice for the profession through inviting 12 specialist medical imaging groups in NZ to participate in a survey. Results: Findings showed strong agreement on potential profiles and on generic criteria within them; however, there was less agreement on specific skills criteria within specialist areas. Conclusions: The authors recommend that one Advanced Scope of Practice be developed for Medical Imaging, with the establishment of generic and specialist criteria. Systems for approval of the overall criteria package for any individual Advanced Practitioner (AP) profile, audit and continuing professional development requirements need to be established by the Medical Radiation Technologists Board (MRTB) to meet the local needs of clinical departments. It is further recommended that the NZIMRT and MRTB promote and support the need for an AP pathway for medical imaging in NZ.

61 RADIATION PROTECTION AND DOSIMETRY↗

Amplatzer Vascular Plugs Versus Coils for Embolization of Pulmonary Arteriovenous Malformations in Patients with Hereditary Hemorrhagic Telangiectasia

PurposeCoil embolization of pulmonary arteriovenous malformations (PAVMs) has a high re-canalization/re-perfusion rate. Embolization with Amplatzer plugs has been previously described, but the long-term efficacy is not established. This study reports the experience of a referral medical center with the use of coils and Amplatzer plugs for treating PAVMs in patients with hereditary hemorrhagic telangiectasia.MethodsThe study was approved by the Institutional Review Board with waiver of informed consent. The cohort included all patients who underwent PAVM embolization in 2004–2014 for whom follow-up imaging scans were available. The medical files were retrospectively reviewed for background data, embolization method (coils, Amplatzer plugs, both), and complications. Re-canalization of treated PAVMs was assessed from intrapulmonary angiograms (following percutaneous procedures) or computed tomography angiograms. Fisher’s exact test and Pearson Chi-squared test or t test were used for statistical analysis, with significance at p < 0.05.Results16 patients met the study criteria. Imaging scans were available for 63 of the total 110 PAVMs treated in 41 procedures. Coils were used for embolization in 37 PAVMs, Amplatzer plugs in 21, and both in five. Median follow-up time was 7.7 years (range 1.4–18.9). Re-canalization was detected in seven vessels, all treated with coils; there were no cases of re-canalization in plug-occluded vessels (p = 0.0413).ConclusionThe use of Amplatzer plugs for the embolization of PAVMs in patients with hemorrhagic telangiectasia is associated with a significantly lower rate of re-canalization of feeding vessels than coils. Long-term prospective studies are required to confirm these findings.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

An Evidence-based Approach to Developing a Management Strategy for Medical Contingencies on the Lunar Surface: The NASA/Haughton-Mars Project (HMP) 2006 Lunar Medical Contingency Simulation at Devon Island

The lunar architecture for future sortie and outpost missions will require humans to serve on the lunar surface considerably longer than the Apollo moon missions. Although the Apollo crewmembers sustained few injuries during their brief lunar surface activity, injuries did occur and are a concern for the longer lunar stays. Interestingly, lunar medical contingency plans were not developed during Apollo. In order to develop an evidence-base for handling a medical contingency on the lunar surface, a simulation using the moon-Mars analog environment at Devon Island, Nunavut, high Canadian Arctic was conducted. Objectives of this study included developing an effective management strategy for dealing with an incapacitated crewmember on the lunar surface, establishing audio/visual and biomedical data connectivity to multiple centers, testing rescue/extraction hardware and procedures, and evaluating in suit increased oxygen consumption. Methods: A review of the Apollo lunar surface activities and personal communications with Apollo lunar crewmembers provided the knowledge base of plausible scenarios that could potentially injure an astronaut during a lunar extravehicular activity (EVA). Objectives were established to demonstrate stabilization and transfer of an injured crewmember and communication with ground controllers at multiple mission control centers. Results: The project objectives were successfully achieved during the simulation. Among these objectives were extraction from a sloped terrain by a two-member crew in a 1 g analog environment, establishing real-time communication to multiple centers, providing biomedical data to flight controllers and crewmembers, and establishing a medical diagnosis and treatment plan from a remote site. Discussion: The simulation provided evidence for the types of equipment and methods for performing extraction of an injured crewmember from a sloped terrain. Additionally, the necessary communications infrastructure to connect multiple centers worldwide was established from a remote site. The surface crewmembers were confronted with a number of unexpected scenarios including environmental, communications, EVA suit, and navigation challenges during the course of the simulation which provided insight into the challenges of carrying out a medical contingency in an austere environment. The knowledge gained from completing the objectives will be incorporated into the exploration medical requirements involving an incapacitated astronaut on the lunar surface.

Scheuring, R. A.↗

Defining Medical Levels of Care for Exploration Missions

NASA medical care standards establish requirements for providing health and medical programs for crewmembers during all phases of a mission. These requirements are intended to prevent or mitigate negative health consequences of long-duration spaceflight, thereby optimizing crew health and performance over the course of the mission. Current standards are documented in the two volumes of the NASA-STD-3001 Space Flight Human-System Standard document, established by the Office of the Chief Health and Medical Officer. Its purpose is to provide uniform technical standards for the design, selection, and application of medical hardware, software, processes, procedures, practices, and methods for human-rated systems. NASA-STD-3001 Vol. 1 identifies five levels of care for human spaceflight. These levels of care are accompanied by several components that illustrate the type of medical care expected for each. The Exploration Medical Capability (ExMC) of the Human Research Program has expanded the context of these provided levels of care and components. This supplemental information includes definitions for each component of care and example actions that describe the type of capabilities that coincide with the definition. This interpretation is necessary in order to fully and systematically define the capabilities required for each level of care in order to define the medical requirements and plan for infrastructure needed for medical systems of future exploration missions, such as one to Mars.

Hailey, M.↗

MO-DE-BRA-02: From Teaching to Learning: Systems-Based-Practice and Practice-Based-Learning Innovations in Medical Physics Education Programs

Purpose: The increasing complexity in the field of radiation medicine and concomitant rise in patient safety concerns call for enhanced systems-level training for future medical physicists and thus commensurate innovations in existing educational program curricula. In this work we report on the introduction of three learning opportunities to augment medical physics educational programs towards building systems-based practice and practice-based learning competencies. Methods: All initiatives were introduced for senior -level graduate students and physics residents in an institution with a newly established medical-physics graduate program and therapeutic-physics residency program. The first, centered on incident learning, was based on a spreadsheet tool that incorporated the reporting structure of the Radiation Oncology-incident Learning System (ROILS), included 120 narratives of published incidents and enabled inter-rater variability calculations. The second, centered on best-practices, was a zero-credit seminar course, where students summarized select presentations from the AAPM virtual library on a weekly basis and moderated class discussions using a point/counterpoint approach. Presentation styles were critiqued. The third; centered on learning-by-teaching, required physics residents to regularly explain fundamental concepts in radiological physics from standard textbooks to board certified physics faculty members. Results: Use of the incident-learning system spreadsheet provided a platform to recast known accidents into the framework of ROILS, thereby increasing awareness of factors contributing to unsafe practice and appreciation for inter-rater variability. The seminar course enhanced awareness of best practices, the effectiveness of presentation styles and encouraged critical thinking. The learn-by-teaching rotation allowed residents to stay abreast of and deepen their knowledge of relevant subjects. Conclusion: The incorporation of systems-driven initiatives broadens comprehension of the wider systems context of medical physics, enhances awareness of resources for innovation, communication and sustained learning while maintaining a metric-driven focus on patient safety within the formative phase of student careers. The initiatives were well-received, feasible, and utilized available or shared-resources translatable across educational programs.