Search NASA⌕ Search

SEARCH · Search NASA

Results for “MEG”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Search for the lepton flavour violating decay $\mu ^+ \rightarrow \mathrm {e}^+ \gamma $ with the full dataset of the MEG experiment: MEG Collaboration

Our final results of the search for the lepton flavour violating decay μ+→e+γ based on the full dataset collected by the MEG experiment at the Paul Scherrer Institut in the period 2009–2013 and totalling 7.5×1014 stopped muons on target are presented. Furthermore, there was not a significant excess of events observed in the dataset with respect to the expected background and a new upper limit on the branching ratio of this decay of B(μ+→e+γ)<4.2×10-13 (90 % confidence level) is established, which represents the most stringent limit on the existence of this decay to date.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Performances of a new generation tracking detector: the MEG II cylindrical drift chamber

Abstract The cylindrical drift chamber is the most innovative part of the MEG II detector, the upgraded version of the MEG experiment. The MEG II chamber differs from the MEG one because it is a single volume cylindrical structure, instead of a segmented one, chosen to improve its resolutions and efficiency in detecting low energy positrons from muon decays at rest. In this paper, we show the characteristics and performances of this fundamental part of the MEG II apparatus and we discuss the impact of its higher resolution and efficiency on the sensitivity of the MEG II experiment. Because of its innovative structure and high quality resolution and efficiency the MEG II cylindrical drift chamber will be a cornerstone in the development of an ideal tracking detector for future positron-electron collider machines.

Physics↗

Towards a New μ→eγ Search with the MEG II Experiment: From Design to Commissioning

The MEG experiment represents the state of the art in the search for the Charged Lepton Flavour Violating μ + →e + γ decay. With its first phase of operations at the Paul Scherrer Institut (PSI), MEG set the most stringent upper limit on the BR (μ + →e + γ) ≤ 4.2×10 –13 at 90% confidence level, imposing one of the tightest constraints on models predicting LFV-enhancements through new physics beyond the Standard Model. An upgrade of the MEG experiment, MEG II, was designed and it is presently in the commissioning phase, aiming at a sensitivity level of 6×10 –14 . The MEG II experiment relies on a series of upgrades, which include an improvement of the photon detector resolutions, brand new detectors on the positron side with better acceptance, efficiency and performances and new and optimized trigger and DAQ electronics to exploit a muon beam intensity twice as high as that of MEG (7×10 7 μ + /s). This paper presents a complete overview of the MEG II experimental apparatus and the current status of the detector commissioning in view of the physics data taking in the upcoming three years.

79 ASTRONOMY AND ASTROPHYSICS↗

Co-Registration of MEG and ULF MRI using a 7 channel low-Tc SQUID system

In human brain imaging, e.g. pre-surgical mapping, it is highly desired to obtain images with high spatial and temporal resolution. However, no single imaging device is capable of producing both a high spatial resolution anatomical image and a high temporal resolution functional image. During the last couple of years significant efforts have been directed towards magnetic resonance imaging (MRI) in fields comparable to the Earth's field, i.e. microtesla fields, or lower fields. The fields in this range are called ultra-low fields (ULF). Interestingly, the idea of magnetic resonance at microtesla fields is more than 50 years old. In ULF MR it is essential to use pre-polarization to increase the signal-to-noise ratio of the signal from the precessing spins, since the magnetization from the measurement field alone is very small. Even with the present level of prepolarization the ULF images are not as highly resolved as their high-field counterparts. By using a 7 channel system equipped with low transition temperature (T{sub c}) Superconducting QUantum Interference Devices (SQUIDs) to perform both ULF MRI and magnetoencephalography (MEG), it is possible to coregister a lower resolution ULF MR image and an MEG image obtained during one run. Thereby, the MEG data is aligned to the ULF MR image after performing a calibration run with a phantom. The ULF MR image can then be used to align the MEG data onto a high-field MR image. Recently, our group presented the first brain images obtained by ULF MRI. The MR imaging was combined with an MEG session performed a posteriori. The subject's head was moved in between the MRI run and the MEG run and no reference coils were used to quantify the translation. The main reason for the translation of the head was to improve the coverage of the auditory evoked response. In this paper, we report interleaved ULF MRI and MEG measurements co-registered in the same system.

42 ENGINEERING↗

Single-trial classification of evoked responses to auditory tones using OPM- and SQUID-MEG

Abstract Objective. Optically pumped magnetometers (OPMs) are emerging as a near-room-temperature alternative to superconducting quantum interference devices (SQUIDs) for magnetoencephalography (MEG). In contrast to SQUIDs, OPMs can be placed in a close proximity to subject’s scalp potentially increasing the signal-to-noise ratio and spatial resolution of MEG. However, experimental demonstrations of these suggested benefits are still scarce. Here, to compare a 24-channel OPM-MEG system to a commercial whole-head SQUID system in a data-driven way, we quantified their performance in classifying single-trial evoked responses. Approach. We measured evoked responses to three auditory tones in six participants using both OPM- and SQUID-MEG systems. We performed pairwise temporal classification of the single-trial responses with linear discriminant analysis as well as multiclass classification with both EEGNet convolutional neural network and xDAWN decoding. Main results. OPMs provided higher classification accuracies than SQUIDs having a similar coverage of the left hemisphere of the participant. However, the SQUID sensors covering the whole helmet had classification scores larger than those of OPMs for two of the tone pairs, demonstrating the benefits of a whole-head measurement. Significance. The results demonstrate that the current OPM-MEG system provides high-quality data about the brain with room for improvement for high bandwidth non-invasive brain–computer interfacing.

Iivanainen, Joonas (ORCID:0000000160344604)↗

A minimum assumption approach to MEG sensor array design

Objective. Our objective is to formulate the problem of the magnetoencephalographic (MEG) sensor array design as a well-posed engineering problem of accurately measuring the neuronal magnetic fields. This is in contrast to the traditional approach that formulates the sensor array design problem in terms of neurobiological interpretability the sensor array measurements. Approach. We use the vector spherical harmonics (VSH) formalism to define a figure-of-merit for an MEG sensor array. We start with an observation that, under certain reasonable assumptions, any array of m perfectly noiseless sensors will attain exactly the same performance, regardless of the sensors' locations and orientations (with the exception of a negligible set of singularly bad sensor configurations). We proceed to the conclusion that under the aforementioned assumptions, the only difference between different array configurations is the effect of (sensor) noise on their performance. We then propose a figure-of-merit that quantifies, with a single number, how much the sensor array in question amplifies the sensor noise. Main results. We derive a formula for intuitively meaningful, yet mathematically rigorous figure-of-merit that summarizes how desirable a particular sensor array design is. We demonstrate that this figure-of-merit is well-behaved enough to be used as a cost function for a general-purpose nonlinear optimization methods such as simulated annealing. We also show that sensor array configurations obtained by such optimizations exhibit properties that are typically expected of 'high-quality' MEG sensor arrays, e.g. high channel information capacity. Significance. Our work paves the way toward designing better MEG sensor arrays by isolating the engineering problem of measuring the neuromagnetic fields out of the bigger problem of studying brain function through neuromagnetic measurements.

60 APPLIED LIFE SCIENCES↗

The Search for μ+ → e+γ with 10–14 Sensitivity: The Upgrade of the MEG Experiment

The MEG experiment took data at the Paul Scherrer Institute in the years 2009–2013 to test the violation of the lepton flavor conservation law, which originates from an accidental symmetry that the Standard Model of elementary particle physics has, and published the most stringent limit on the charged lepton flavor violating decay μ+→e+γ: BR(μ+→e+γ) <4.2×10−13 at 90% confidence level. The MEG detector has been upgraded in order to reach a sensitivity of 6×10−14. The basic principle of MEG II is to achieve the highest possible sensitivity using the full muon beam intensity at the Paul Scherrer Institute (7×107 muons/s) with an upgraded detector. The main improvements are better rate capability of all sub-detectors and improved resolutions while keeping the same detector concept. In this paper, we present the current status of the preparation, integration and commissioning of the MEG II detector in the recent engineering runs.

physics beyond the Standard Model↗

Lepton-flavor violating axions at MEG II

We study the sensitivity of the existing MEG data to lepton flavor violating axion-like particles produced through μ + → e + a$\gamma$ and estimate the discovery potential for the upcoming MEG II experiment in this channel. The MEG II signal efficiency can be improved significantly if a new trigger can be implemented in a dedicated run with a reduced beam intensity. This search would establish the world leading measurement in this channel with only 1 month of data taking.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

{mu}{yields}e{gamma}-MEG

The MEG experiment started a search for a lepton violating (LFV) muon decay, {mu}{sup +}{yields}e{sup +}{gamma}, at Paul Scherrer Institut(PSI) in Switzerland. The LFV muon decay does not occur in the standard model, while new theories, such as super symmetric grand unified theory and seesaw model of neutrinos, predict observable branching ratio just below the current upper limit (1.2x10{sup -12}). MEG is designed to improve the sensitivity by two orders of magnitude. In this article, the system of the MEG experiment and its data taking in 2008 are described.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Operation and performance of the MEG II detector

Abstract The MEG II experiment, located at the Paul Scherrer Institut (PSI) in Switzerland, is the successor to the MEG experiment, which completed data taking in 2013. MEG II started fully operational data taking in 2021, with the goal of improving the sensitivity of the$$\upmu ^+ \rightarrow {\textrm{e}}^+ \upgamma $$ μ + → e + γ decay down to$$\sim 6 \times 10^{-14}$$ ∼ 6 × 10 - 14 almost an order of magnitude better than the current limit. In this paper, we describe the operation and performance of the experiment and give a new estimate of its sensitivity versus data acquisition time.

Physics↗

Measurement of the radiative decay of polarized muons in the MEG experiment

Here, we studied the radiative muon decay μ + → e + νν¯γ by using for the first time an almost fully polarized muon source. We identified a large sample (~13,000) of these decays in a total sample of 1.8×10 14 positive muon decays collected in the MEG experiment in the years 2009–2010 and measured the branching ratio B(μ → eνν¯γ)=(6.03 ± 0.14(stat.) ± 0.53(sys.))×10 –8 for E e > 45 MeV and E γ > 40 MeV, consistent with the Standard Model prediction. The precise measurement of this decay mode provides a basic tool for the timing calibration, a normalization channel, and a strong quality check of the complete MEG experiment in the search for μ+→e+γ process.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

The design of the MEG II experiment

The MEG experiment, designed to search for the &#x03BC;<!-- μ --> + &#x2192;<!-- → --> e + &#x03B3;<!-- γ --> decay, completed data-taking in 2013 reaching a sensitivity level of 5.3 &#x00D7;<!-- × --> 10 &#x2212;<!-- - --> 13 for the branching ratio. In order to increase the sensitivity reach of the experiment by an order of magnitude to the level of 6 &#x00D7;<!-- × --> 10 &#x2212;<!-- - --> 14 , a total upgrade, involving substantial changes to the experiment, has been undertaken, known as MEG II. We present both the motivation for the upgrade and a detailed overview of the design of the experiment and of the expected detector performance.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

A search for $$\upmu ^+ \rightarrow \textrm{e}^+ \upgamma $$ with the first dataset of the MEG II experiment

Abstract The MEG II experiment, based at the Paul Scherrer Institut in Switzerland, reports the result of a search for the decay$$\upmu ^+ \rightarrow {\textrm{e}}^+ \upgamma $$ μ + → e + γ from data taken in the first physics run in 2021. No excess of events over the expected background is observed, yielding an upper limit on the branching ratio of$${\mathcal {B}} (\upmu ^+ \rightarrow {\textrm{e}}^+ \upgamma ) < 7.5 \times 10^{-13}$$ B ( μ + → e + γ ) < 7.5 × 10 - 13 (90% CL). The combination of this result and the limit obtained by MEG gives$${\mathcal {B}} (\upmu ^+ \rightarrow {\textrm{e}}^+ \upgamma ) < 3.1 \times 10^{-13}$$ B ( μ + → e + γ ) < 3.1 × 10 - 13 (90% CL), which is the most stringent limit to date. A ten-fold larger sample of data is being collected during the years 2022–2023, and data-taking will continue in the coming years.

Physics↗

Extreme Ultraviolet Variability Experiment (EVE) Multiple EUV Grating Spectrographs (MEGS): Radiometric Calibrations and Results

The NASA Solar Dynamics Observatory (SDO), scheduled for launch in early 2010, incorporates a suite of instruments including the Extreme Ultraviolet Variability Experiment (EVE). EVE has multiple instruments including the Multiple Extreme ultraviolet Grating Spectrographs (MEGS) A, B, and P instruments, the Solar Aspect Monitor (SAM), and the Extreme ultraviolet SpectroPhotometer (ESP). The radiometric calibration of EVE, necessary to convert the instrument counts to physical units, was performed at the National Institute of Standards and Technology (NIST) Synchrotron Ultraviolet Radiation Facility (SURF III) located in Gaithersburg, Maryland. This paper presents the results and derived accuracy of this radiometric calibration for the MEGS A, B, P, and SAM instruments, while the calibration of the ESP instrument is addressed by Didkovsky et al. . In addition, solar measurements that were taken on 14 April 2008, during the NASA 36.240 sounding-rocket flight, are shown for the prototype EVE instruments.

Hock, R. A.↗

The MEG experiment: status and perspectives

The MEG experiment, a sensitive search for the mu->egamma decay, has started operating in September 2008. Analysis of data collected during the initial three months of operation is still ongoing and soon to be finalized. The detector performance during Run 2008 is reviewed, with remarks on perspectives for Run 2009.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗