A Crew Seat for Human Exploration in Multiple Gravity Environments

This work attempts to develop a single crew seating solution that is applicable across a range of gravity environments encountered by spacecraft proposed in several conceptual spacecraft architectures. All of these spacecraft will need to provide some sort of stationary accommodation for the crew for performing various activities such as work in science laboratories, maintenance and repair facilities, medical care facilities, and spacecraft operations centers, as well as for basic habitation in crew quarters, entertainment / relaxation facilities, and crew dining facilities. Depending on the spacecraft or architecture, this stationary accommodation may be experienced continuously in microgravity, such as would be the case for the Deep Space Exploration Vehicle. Alternately, it could be in continuous lunar or Martian gravity, such as the Common Habitat base camps. It could experience fractional gravity, such as a Pressurized Rover for In-Space Missions at a Near Earth Asteroid or one of the Martian moons. It could alternate between artificial gravity and microgravity, such as the Nautilus-X. It could alternate between microgravity and lunar or Martian gravity, such as the SpaceX Starship Human Landing System or the Blue Origin Blue Moon Block 2 Human Landing System. Or it could be in continuous Earth gravity, such as ground trainer systems. Prior human spaceflight systems for stationary accommodation have been focused on microgravity applications. These systems have their own limitations and cannot be used in a gravity environment. A public crowdsourcing campaign generated dozens of ideas, which ultimately generated a Gecko Mobility Aids system for crew translation and the Multi-Gravity Crew Seat (MGCS) for stationary accommodation. The MGCS functions in gravity as a traditional terrestrial seat, performing functions of load for the overall body and forearms, as well as head and neck load relief while positioning the body within range of an intended task. In microgravity, the MGCS functions as a body restraint, securing the body against inadvertent drifting by applying a restraining pressure at the front and back of the thighs, shoulders, and back. The initial MGCS concept was developed in a NASA hackathon and was refined through a review of dozens of terrestrial seating styles. Additionally, a review of anthropometry and biomechanics data related to the neutral body posture was conducted to help inform the microgravity configuration of the MGCS. A series of CAD models were iteratively developed, with subject matter expert reviews leading to design improvements. A scale model was constructed and used with a humanoid model to demonstrate MGCS accommodation of a human-like body in both gravity and microgravity modes. Work to develop a full-scale protype of the MGCS is discussed, including design and fabrication of the headrest, arm rest, seat back, seat pan, seat base, and the conversion mechanisms. A 1-g human-in-the-loop evaluation of the prototype assessed the acceptability of performing seated activities in the MGCS, collecting data on the usability, comfort, and ease of ingress/egress. Based on the evaluation results, design modifications needed for reduced gravity testing are documented and initial work is indicated for a reduced gravity test plan.

Restraints and Mobility Aids↗

Evaluation of Preoperative and Intraoperative Mobile Gamma Camera Imaging in Sentinel Lymph Node Biopsy for Melanoma Independent of Preoperative Lymphoscintigraphy

Sentinel lymph node biopsy (SLNB) is standard practice for staging cutaneous melanoma. High false negative rates have increased interest in adjunctive techniques for localizing SLNs. Mobile gamma cameras (MGCs) represent potential tools to enhance SLNB performance. Twenty eligible melanoma patients underwent 99mTc sulfur colloid injection and standard lymphoscintigraphy with a fixed gamma camera (FGC). A survey using a 20 cm square MGC, performed immediately preoperatively by the study surgeon, was used to establish an operative plan while blinded to the FGC results. Subsequently, SLNB was performed using a gamma probe and a novel 6 cm diameter handheld MGC. A total of 24 SLN basins were detected by FGC. Prior to unblinding, all 24 basins were identified with the preoperative MGC, and the operative plan established by preoperative MGC imaging was confirmed accurate by review of the FGC images. All individual SLNs were identified during intraoperative MGC imaging, and in 5/24 (21%) cases, additional clinical information was obtained from the MGC. Preoperative MGC images provide information consistent with FGC images for planning SLNB and in some cases provides additional information that aided in surgical decision-making.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Breakdown Features of Various Microstrip-Type Gas Counter Designs and Their Improvements

Breakdown mechanisms and spurious pulses, the precursors to some breakdowns, were studied experimentally for both uncoated and coated Microstrip Gas Counters (MSGCs) of different geometries, as well as for MicroGap Counters (MGCs) and for the "Compteur A Trou" (CAT). It was found that in all cases the breakdowns occurred through surface streamers, although the exact mechanism of streamer formation depended on the particular detector design. Based on these studies, new designs of microstrip detectors, in which the role of the substrate was minimized, were elaborated and tested. In some of these detectors, especially with large pitches (greater than 2mm), gains up to 2-3 x 10(exp 5) were achieved together with good rate characteristics. The ultimate gain limit in all geometries was still set by spark-inducing streamers which appeared at some critical charge density in the avalanche. To avoid this, and particularly to enhance the performance of small-pitch MSGCs, preamplification structures can be used. Utilizing a parallel plate avalanche chamber as a front end to an MSGC resulted in an overall gain of approximately 10(exp 6), limited in this case only by charge saturation.

Peskov, V.↗

Utility Microgrid Controller Test Plan

The functional requirements of many microgrid controllers (MGCs) are expanding and evolving to meet growing utility and community needs. At a high level, the utility microgrid controller serves resilience and reliability use cases by coordinating transitions between grid-connected and islanded states and by managing the system during island operations. This includes control scenarios that require the microgrid controller to use flexible microgrid boundaries, maintain energy balance, coordinate with peer systems, and manage grid-forming (GFM) and grid-following (GFL) DER. In order to evaluate these functional enhancements, microgrid controller test plans must also be developed to ensure that the implemented controllers provide adequate performance. This report provides MGC test plans for both island operation and transition functions. The functions covered in this first edition report include feeder level energy management, island constraint management, secondary voltage and frequency control, black start, and synchronized reconnection. These test cases can be applied to utility-managed microgrid controllers that exclusively manage utility-owned equipment; the tests also apply to third-party managed microgrid controllers that coordinate with utility- and customer-owned equipment. The report can also be used by technology developers and project developers in industry to evaluate control strategies and performance characteristics for community microgrid controllers.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Laboratory Evaluation of Commercial Utility Microgrid Controller Test Results

The functional requirements of many microgrid controllers (MGCs) are expanding and evolving to meet growing utility and community needs. At a high level, the utility microgrid controller serves resilience and reliability use cases by coordinating transitions between grid-connected and islanded states and by managing the system during island operations. This includes control scenarios that require the microgrid controller to use flexible microgrid boundaries, maintain energy balance, coordinate with peer systems, and manage grid-forming (GFM) and grid-following (GFL) distributed energy resources (DER). In order to evaluate these functional enhancements, microgrid controller test plans must also be developed to ensure that the implemented controllers provide adequate performance. This report provides MGC test plans for both island operation and transition functions. The functions covered in this report include feeder level energy management, island constraint management, secondary voltage and frequency control, black start, and synchronized reconnection. This second edition update also includes results from applying the tests to a commercial utility microgrid controller. These results evaluate the performance and reliability of the controller under various operational scenarios. It identifies specific areas where the controller excels and highlights gaps that need to be addressed for future enhancements. The application of these test plans on real-world system behavior provides insights on commercial equipment readiness for field deployment. These test cases can be applied to utility-managed microgrid controllers that exclusively manage utility-owned equipment; the tests also apply to third-party managed microgrid controllers that coordinate with utility- and customer-owned equipment. The report can also be used by technology developers and project developers in industry to evaluate control strategies and performance characteristics for community microgrid controllers.

24 POWER TRANSMISSION AND DISTRIBUTION↗