Search NASA⌕ Search

SEARCH · Search NASA

Results for “MIC”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Indium (In)- and tin (Sn)-based metal induced crystallization (MIC) on amorphous germanium (α-Ge)

Highlights: • In- and Sn-based MIC phenomenon on amorphous (α)-Ge is newly reported. • The In- and Sn-MIC phenomenon respectively started at 250 °C and 400 °C. • The Sn-MIC process presents higher sheet resistance and bigger crystal grains. - Abstract: In this paper, metal-induced crystallization (MIC) phenomenon on α-Ge by indium (In) and tin (Sn) are thoroughly investigated. In- and Sn-MIC process respectively started at 250 °C and 400 °C. Compared to the previously reported MIC samples including In-MIC, Sn-MIC process presented higher sheet resistance (similar to that of SPC) and bigger crystal grains above 50 nm (slightly smaller than that of SPC). According to SIMS analysis, Sn atoms diffused more slowly into Ge than In at 400 °C, providing lower density of heterogeneous nuclei induced by metals and consequently larger crystal grains.

36 MATERIALS SCIENCE↗

A Rapid and High Throughput MIC Determination Method to Screen Uranium Resistant Microorganisms

The assessment of minimum inhibitory concentration (MIC) is a conventional technique used for the screening of microbial resistance against antibiotics, biocides, and contaminants such as heavy metals. However, as part of our ongoing work, we have observed biases associated with using traditional liquid MIC method to screen microbial heavy metal resistance, including both bacterial and fungal strains. Specifically, the addition of uranium into synthetic media causes immediate precipitation prior to the initiation of microbial growth, thus hampering the optical density measurements, and the obtained MIC values are thus flawed and inaccurate. To address this discrepancy, we report the optimization and development of a serial-dilution-based MIC method conducted on solid growth media supplemented with uranium, which is more accurate, relative to the testing of MICs performed in liquid cultures. Notably, we report on the efficacy of this method to screen not only bacteria that are resistant to uranium but also demonstrate the successful application to yeast and fungal isolates, for their ability to resist uranium, is more accurate and sensitive relative to the liquid method. We believe that this newly developed method to screen heavy metal resistance, such as uranium, is far superior to the existing liquid MIC method and propose replacing the liquid assay with the solid plate MIC reported herein.

54 ENVIRONMENTAL SCIENCES↗

Variations in pharmacokinetic-pharmacodynamic target values across MICs and their potential impact on determination of susceptibility test interpretive criteria

Abstract Background An antibacterial drug’s susceptibility test interpretive criteria (STIC) are determined by integrating clinical, microbiological and pharmacokinetic-pharmacodynamic (PK-PD) data. PTA analysis plays a pivotal or supportive role in STIC determination and is heavily dependent on the PK-PD target values determined from animal PK-PD studies. Therefore, variations in PK-PD target values may impact STIC determination. Factors contributing to variation in the PK-PD target values include the number of and MICs for bacterial isolates used in animal PK-PD studies. Objectives To analyse the relationship between PK-PD target values and MICs, describe the variations in PK-PD target values of isolates and evaluate whether the proposed/target STICs were within the ranges of the MICs for isolates used in animal PK-PD studies. Methods A database was compiled for this research by screening animal PK-PD study reports submitted to the FDA from 10 new drug applications (NDAs). Results A relationship evaluation between PK-PD target values and MICs for tested isolates for seven drugs (that used AUC/MIC ratio as the PK-PD index) showed that, generally, the AUC/MIC values decreased with an increase in MIC. These target values were highly variable, with the percentage coefficient of variation ranging between 1% and 132% for isolates having the same MIC. For 16/27 (59%) drug/bacteria combinations from all 10 drugs, the proposed/target STICs were higher than the highest MIC for bacteria isolates evaluated, while 6/27 (22.5%) were lower. Conclusions This research suggests that careful considerations related to selection of bacterial isolates for animal PK-PD studies could strengthen the STIC determination process.

Waack, Ursula↗

MIC-DP: A Scalable Correlation-Aware Differential Privacy Framework for High-Dimensional Data

Conventional differential privacy (DP) assumes record independence, limiting effectiveness on real-world datasets with temporal, spatial, or structural correlations. These dependencies undermine privacy guarantees and degrade utility in domains like healthcare, IoT, and smart city analytics. We propose Maximum Information Correlated Differential Privacy (MIC-DP), a novel framework that dynamically calibrates noise based on statistical dependencies. MIC-DP uses the Maximum Information Coefficient (MIC) to capture both linear and nonlinear correlations without explicit modeling, enabling adaptive sensitivity adjustment and improved privacy–utility trade-offs. Evaluations on healthcare (MIMIC), demographic (ACI), and synthetic datasets show that MIC-DP reduces mean absolute error (MAE) by up to 5.2% under strict privacy budgets (ϵ≤1), with aggregate utility improvements reaching 18% across datasets and evaluation metrics. MIC-DP provides formal (ϵ,δ)-privacy guarantees, scales efficiently with feature count, and supports deployment in moderate-scale, privacy-sensitive applications. Its tunable performance and runtime efficiency make MIC-DP suitable for privacy-sensitive applications where low-latency analytics and strong privacy guarantees must coexist. These results demonstrate MIC-DP’s effectiveness as a correlation-aware solution for practical DP.

Yang, Wenjun [Univ. of Washington, Tacoma, WA (Uni↗

Using machine learning to predict antimicrobial MICs and associated genomic features for nontyphoidal Salmonella

Nontyphoidal Salmonella species are the leading bacterial cause of food-borne disease in the United States. Whole genome sequences and paired antimicrobial susceptibility data are available for Salmonella strains because of surveillance efforts from public health agencies. In this study, a collection of 5,278 nontyphoidal Salmonella genomes, collected over 15 years in the United States, were used to generate XGBoost-based machine learning models for predicting minimum inhibitory concentrations (MICs) for 15 antibiotics. The MIC prediction models have an overall average accuracy of 95% within ± 1 two-fold dilution step (confidence interval of 95-95%), an average very major error rate of 2.7% (confidence interval of 2.4-3.0%) and an average major error rate of 0.1% (confidence interval of 0.1-0.2%). The model predicts MICs with no a priori information about the underlying gene content or resistance phenotypes of the strains. By selecting diverse genomes for training sets, we show that highly accurate MIC prediction models can be generated with fewer than 500 genomes. We also show that our approach for predicting MICs is stable over time despite annual fluctuations in antimicrobial resistance gene content in the sampled genomes. Finally, using feature selection, we explore the important genomic regions identified by the models for predicting MICs. To date, this is one of the largest MIC modeling studies to be published. Furthermore, our strategy for developing whole genome sequence-based models for surveillance and clinical diagnostics can be readily applied to other important human pathogens.

59 BASIC BIOLOGICAL SCIENCES↗

The Youngest Planet to Have a Spin-Orbit Alignment Measurement AU Mic b

We report measurements of the sky-projected spin–orbit angle for AU Mic b, a Neptune-size planet orbiting a very young (∼20 Myr) nearby pre-main-sequence M-dwarf star, which also hosts a bright, edge-on, debris disk. The planet was recently discovered from preliminary analysis of radial-velocity observations and confirmed to be transiting its host star from photometric data from the NASA’s TESS mission. We obtained radial-velocity measurements of AU Mic over the course of two partially observable transits and one full transit of planet b from high-resolution spectroscopic observations made with the Minerva-Australis telescope array. Only a marginal detection of the Rossiter–McLaughlin effect signal was obtained from the radial velocities, in part due to AU Mic being an extremely active star and the lack of full transit coverage plus sufficient out-of-transit baseline. As such, a precise determination of the obliquity for AU Mic b is not possible in this study and we find a sky-projected spin–orbit angle of λ=47{sub −54}{sup +26°}. This result is consistent with both the planet’s orbit being aligned or highly misaligned with the spin axis of its host star. Our measurement independently agrees with, but is far less precise than observations carried out on other instruments around the same time that measure a low-obliquity orbit for the planet. AU Mic is the youngest exoplanetary system for which the projected spin–orbit angle has been measured, making it a key data point in the study of the formation and migration of exoplanets—particularly given that the system is also host to a bright debris disk.

47 OTHER INSTRUMENTATION↗

AU Microscopii in the Far-UV Observations in Quiescence, During Flares, and Implications for AU Mic b and c

High-energy X-ray and ultraviolet(UV)radiation from young stars impacts planetary atmospheric chemistry and mass loss. The active∼22 Myr M dwarf AU Mic hosts two exoplanets orbiting interior to its debris disk. Therefore, this system provides a unique opportunity to quantify the effects of stellar X-ray and UV irradiation on planetary atmospheres as a function of both age and orbital separation. In this paper, we present over 5 hr of far-UV (FUV)observations of AU Mic taken with the Cosmic Origins Spectrograph (COS; 1070-1360Å) on the Hubble Space Telescope (HST). We provide an itemization of 120 emission features in the HST/COS FUV spectrum and quantify the flux contributions from formation temperatures ranging from 104 to 107K. We detect 13 flares in the FUV white-light curve with energies ranging from 1029 to 1031erg s. The majority of the energy in each of these flares is released from the transition region between the chromosphere and the corona. There is a 100×increase influx at continuum wavelengths λ<1100 Å in each flare, which may be caused by thermal Bremsstrahlung emission. We calculate that the baseline atmospheric mass-loss rate for AU Mic b is∼108 g s−1, although this rate can be as high as∼1014 g s−1during flares with Lflare 10-33 erg s−1. Finally, we model the transmission spectra for AU Mic b and c with a new panchromatic spectrum of AU Mic and motivate future JWST observations of these planets.

Adina D Feinstein↗

The Variable Detection of Atmospheric Escape around the Young, Hot Neptune AU Mic b

Photoevaporation is a potential explanation for several features within exoplanet demographics. Atmospheric escape observed in young Neptune-sized exoplanets can provide insight into and characterize which mechanisms drive this evolution and at what times they dominate. AU Mic b is one such exoplanet, slightly larger than Neptune (4.19 R ⊕ ). It closely orbits a 23 Myr pre-main-sequence M dwarf with an orbital period of 8.46 days. We obtained two visits of AU Mic b at Lyα with Hubble Space Telescope (HST)/Space Telescope Imaging Spectrograph. One flare within the first HST visit is characterized and removed from our search for a planetary transit. We present a nondetection in our first visit, followed by the detection of escaping neutral hydrogen ahead of the planet in our second visit. The outflow absorbed ∼30% of the star’s Lyα blue wing 2.5 hr before the planet’s white-light transit. We estimate that the highest-velocity escaping material has a column density of 10 13.96 cm −2 and is moving 61.26 km s −1 away from the host star. AU Mic b’s large high-energy irradiation could photoionize its escaping neutral hydrogen in 44 minutes, rendering it temporarily unobservable. Our time-variable Lyα transit ahead of AU Mic b could also be explained by an intermediate stellar wind strength from AU Mic that shapes the escaping material into a leading tail. Future Lyα observations of this system will confirm and characterize the unique variable nature of its Lyα transit, which, combined with modeling, will tune the importance of stellar wind and photoionization.

Exoplanets↗

TU-AB-BRC-10: Modeling of Radiotherapy Linac Source Terms Using ARCHER Monte Carlo Code: Performance Comparison of GPU and MIC Computing Accelerators

Purpose: (1) To perform phase space (PS) based source modeling for Tomotherapy and Varian TrueBeam 6 MV Linacs, (2) to examine the accuracy and performance of the ARCHER Monte Carlo code on a heterogeneous computing platform with Many Integrated Core coprocessors (MIC, aka Xeon Phi) and GPUs, and (3) to explore the software micro-optimization methods. Methods: The patient-specific source of Tomotherapy and Varian TrueBeam Linacs was modeled using the PS approach. For the helical Tomotherapy case, the PS data were calculated in our previous study (Su et al. 2014 41(7) Medical Physics). For the single-view Varian TrueBeam case, we analytically derived them from the raw patient-independent PS data in IAEA’s database, partial geometry information of the jaw and MLC as well as the fluence map. The phantom was generated from DICOM images. The Monte Carlo simulation was performed by ARCHER-MIC and GPU codes, which were benchmarked against a modified parallel DPM code. Software micro-optimization was systematically conducted, and was focused on SIMD vectorization of tight for-loops and data prefetch, with the ultimate goal of increasing 512-bit register utilization and reducing memory access latency. Results: Dose calculation was performed for two clinical cases, a Tomotherapy-based prostate cancer treatment and a TrueBeam-based left breast treatment. ARCHER was verified against the DPM code. The statistical uncertainty of the dose to the PTV was less than 1%. Using double-precision, the total wall time of the multithreaded CPU code on a X5650 CPU was 339 seconds for the Tomotherapy case and 131 seconds for the TrueBeam, while on 3 5110P MICs it was reduced to 79 and 59 seconds, respectively. The single-precision GPU code on a K40 GPU took 45 seconds for the Tomotherapy dose calculation. Conclusion: We have extended ARCHER, the MIC and GPU-based Monte Carlo dose engine to Tomotherapy and Truebeam dose calculations.

60 APPLIED LIFE SCIENCES↗

Optical Coronagraphic Spectroscopy of AU Mic: Evidence of Time Variable Colors?

We present coronagraphic long slit spectra of AU Mic's debris disk taken with the STIS instrument aboard the Hubble Space Telescope. Our spectra are the first spatially-resolved, scattered light spectra of the system's disk, which we detect at projected distances between approximately 10 and 45 au. Our spectra cover a wavelength range between 5200 and 10200 Angstrom. We find that the color of AU Mic's debris disk is bluest at small (12-17 au) projected separations. These results both confirm and quantify the findings qualitatively noted by Krist et al. and are different than IR observations that suggested a uniform blue or gray color as a function of projected separation in this region of the disk. Unlike previous literature, which reported that the color of AU Mic's disk became increasingly more blue as a function of projected separation beyond approx. 30 au, we find the disk's optical color between 35 and 45 au to be uniformly blue on the southeast side of the disk and decreasingly blue on the northwest side. We note that this apparent change in disk color at larger projected separations coincides with several fast, outward moving ''features'' that are passing through this region of the southeast side of the disk. We speculate that these phenomenon might be related and that the fast moving features could be changing the localized distribution of sub-micron-sized grains as they pass by, thereby reducing the blue color of the disk in the process. We encourage follow-up optical spectroscopic observations of AU Mic to both confirm this result and search for further modifications of the disk color caused by additional fast moving features propagating through the disk.

Lomax, Jamie R.↗

High-fidelity Imaging of the Inner AU Mic Debris Disk: Evidence of Differential Wind Sculpting?

We present new high-fidelity optical coronagraphic imagery of the inner ∼50 au of AU Mic's edge-on debris disk using the BAR5 occulter of the Hubble Space Telescope Imaging Spectrograph (HST/STIS) obtained on 2018 July 26–27. This new imagery reveals that "feature A," residing at a projected stellocentric separation of 14.2 au on the southeast side of the disk, exhibits an apparent "loop-like" morphology at the time of our observations. The loop has a projected width of 1.5 au and rises 2.3 au above the disk midplane. We also explored Transiting Exoplanet Survey Satellite photometric observations of AU Mic that are consistent with evidence of two starspot complexes in the system. The likely co-alignment of the stellar and disk rotational axes breaks degeneracies in detailed spot modeling, indicating that AU Mic's projected magnetic field axis is offset from its rotational axis. We speculate that small grains in AU Mic's disk could be sculpted by a time-dependent wind that is influenced by this offset magnetic field axis, analogous to co-rotating solar interaction regions that sculpt and influence the inner and outer regions of our own Heliosphere. Alternatively, if the observed spot modulation is indicative of a significant misalignment of the stellar and disk rotational axes, we suggest that the disk could still be sculpted by the differential equatorial versus polar wind that it sees with every stellar rotation.

John P. Wisniewski↗

Thread-level parallelization and optimization of NWChem for the Intel MIC architecture

In the multicore era it was possible to exploit the increase in on-chip parallelism by simply running multiple MPI processes per chip. Unfortunately, manycore processors' greatly increased thread- and data-level parallelism coupled with a reduced memory capacity demand an altogether different approach. In this paper we explore augmenting two NWChem modules, triples correction of the CCSD(T) and Fock matrix construction, with OpenMP in order that they might run efficiently on future manycore architectures. As the next NERSC machine will be a self-hosted Intel MIC (Xeon Phi) based supercomputer, we leverage an existing MIC testbed at NERSC to evaluate our experiments. In order to proxy the fact that future MIC machines will not have a host processor, we run all of our experiments in native mode. We found that while straightforward application of OpenMP to the deep loop nests associated with the tensor contractions of CCSD(T) was sufficient in attaining high performance, significant e ort was required to safely and efeciently thread the TEXAS integral package when constructing the Fock matrix. Ultimately, our new MPI+OpenMP hybrid implementations attain up to 65× better performance for the triples part of the CCSD(T) due in large part to the fact that the limited on-card memory limits the existing MPI implementation to a single process per card. Additionally, we obtain up to 1.6× better performance on Fock matrix constructions when compared with the best MPI implementations running multiple processes per card.

CCSD(T)↗

Thread-Level Parallelization and Optimization of NWChem for the Intel MIC Architecture

In the multicore era it was possible to exploit the increase in on-chip parallelism by simply running multiple MPI processes per chip. Unfortunately, manycore processors' greatly increased thread- and data-level parallelism coupled with a reduced memory capacity demand an altogether different approach. In this paper we explore augmenting two NWChem modules, triples correction of the CCSD(T) and Fock matrix construction, with OpenMP in order that they might run efficiently on future manycore architectures. As the next NERSC machine will be a self-hosted Intel MIC (Xeon Phi) based supercomputer, we leverage an existing MIC testbed at NERSC to evaluate our experiments. In order to proxy the fact that future MIC machines will not have a host processor, we run all of our experiments in tt native mode. We found that while straightforward application of OpenMP to the deep loop nests associated with the tensor contractions of CCSD(T) was sufficient in attaining high performance, significant effort was required to safely and efficiently thread the TEXAS integral package when constructing the Fock matrix. Ultimately, our new MPI OpenMP hybrid implementations attain up to 65x better performance for the triples part of the CCSD(T) due in large part to the fact that the limited on-card memory limits the existing MPI implementation to a single process per card. Additionally, we obtain up to 1.6x better performance on Fock matrix constructions when compared with the best MPI implementations running multiple processes per card.

97 MATHEMATICS AND COMPUTING↗

Elemental and Isotopic Analysis of Uranium Oxide an NIST Glass Standards by FEMTOSECOND-LA-ICP-MIC-MS

The objective of this work was to test and demonstrate the analytical figures of merit of a femtosecond-laser ablation (fs-LA) system coupled with an inductively coupled plasma-multi-ion collector-mass spectrometer (ICP-MIC-MS). The mobile fs-LA sampling system was designed and assembled at Ames Laboratory and shipped to Oak Ridge National Laboratory (ORNL), where it was integrated with an ICP-MIC-MS. The test period of the integrated systems was February 2-6, 2009. Spatially-resolved analysis of particulate samples is accomplished by 100-shot laser ablation using a fs-pulsewidth laser and monitoring selected isotopes in the resulting ICP-MS transient signal. The capability of performing high sensitivity, spatially resolved, isotopic analyses with high accuracy and precision and with virtually no sample preparation makes fs-LA-ICP-MIC-MS valuable for the measurement of actinide isotopes at low concentrations in very small samples for nonproliferation purposes. Femtosecond-LA has been shown to generate particles from the sample that are more representative of the bulk composition, thereby minimizing weaknesses encountered in previous work using nanosecond-LA (ns-LA). The improvement of fs- over ns-LA sampling arises from the different mechanisms for transfer of energy into the sample in these two laser pulse-length regimes. The shorter duration fs-LA pulses induce less heating and cause less damage to the sample than the longer ns pulses. This results in better stoichiometric sampling (i.e., a closer correlation between the composition of the ablated particles and that of the original solid sample), which improves accuracy for both intra- and inter-elemental analysis. The primary samples analyzed in this work are (a) solid uranium oxide powdered samples having different {sup 235}U to {sup 238}U concentration ratios, and (b) glass reference materials (NIST 610, 612, 614, and 616). Solid uranium oxide samples containing {sup 235}U in depleted, natural, and enriched abundances were analyzed as particle aggregates immobilized in a collodion substrate. The uranium oxide samples were nuclear reference materials (CRMs U0002, U005-A, 129-A, U015, U030-A, and U050) obtained from New Brunswick Laboratory-USDOE.

07 ISOTOPE AND RADIATION SOURCES↗

IUE spectra of flares on AU Mic

Some IUE spectra were obtained in August 1980 through a substantial part of the optical cycle of the BY Draconis-type, spotted M dwarf star, AU Mic. No modulation of the ultraviolet emission line fluxes in antiphase with the optical curve is detected. Simultaneous optical photometry of AU Mic shows remarkably poor correlation of optical flare strength and ultraviolet emission-line enhancements. The flares detected on AU Mic show considerable variety in the degree of enhancement in the various emission lines and optical continuum.

Butler, C. J.↗

MDS MIC Catalog Inputs

This viewgraph presentation reviews the inputs to the MDS Medical Information Communique (MIC) catalog. The purpose of the group is to provide input for updating the MDS MIC Catalog and to request that MMOP assign Action Item to other working groups and FSs to support the MITWG Process for developing MIC-DDs.

Johnson-Throop, Kathy A.↗

Organocatalysis promoted by 1,2,3-triazolylidenes (MICs): carbenes which make a difference

N-Heterocyclic carbenes (NHCs) hold a unique significance in organometallic catalysis and are powerful organocatalysts for a variety of organic transformations involving crucial intermediates such as Breslow intermediates (BIs), deprotonated BIs (BI − s), ketyl radicals (KRs), and acyl azoliums (AAs). To address the remaining challenges facing reactions catalyzed by NHCs, non-classical stable carbenes, namely 1,2,3-triazolylidenes (MICs), cousins of NHCs, have shown great potential. MICs share similar features with typical NHCs but possess unique characteristics, such as enhanced σ-donor ability and absence of dimerization. Consequently, they have emerged as effective metal-free carbene catalysts for various chemical transformations. Furthermore, this review provides an overview of the fundamental characteristics of 1,2,3-triazolylidenes, along with the significant organic synthetic applications of these carbenes.

Gao, Fan [Renmin University of China, Beijing (Chi↗

The AU MIC debris disk: Far-infrared and submillimeter resolved imaging

We present far-infrared and submillimeter maps from the Herschel Space Observatory and the James Clerk Maxwell Telescope of the debris disk host star AU Microscopii. Disk emission is detected at 70, 160, 250, 350, 450, 500, and 850 μm. The disk is resolved at 70, 160, and 450 μm. In addition to the planetesimal belt, we detect thermal emission from AU Mic’s halo for the first time. In contrast to the scattered light images, no asymmetries are evident in the disk. The fractional luminosity of the disk is 3.9×10{sup −4} and its milimeter-grain dust mass is 0.01 M{sub ⊕} (±20%). We create a simple spatial model that reconciles the disk spectral energy distribution as a blackbody of 53 ± 2 K (a composite of 39 and 50 K components) and the presence of small (non-blackbody) grains which populate the extended halo. The best-fit model is consistent with the “birth ring” model explored in earlier works, i.e., an edge-on dust belt extending from 8.8 to 40 AU, but with an additional halo component with an r{sup −1.5} surface density profile extending to the limits of sensitivity (140 AU). We confirm that AU Mic does not exert enough radiation force to blow out grains. For stellar mass-loss rates of 10–100 times solar, compact (zero porosity) grains can only be removed if they are very small; consistently with previous work, if the porosity is 0.9, then grains approaching 0.1 μm can be removed via corpuscular forces (i.e., the stellar wind).

79 ASTRONOMY AND ASTROPHYSICS↗