Search NASA⌕ Search

SEARCH · Search NASA

Results for “MICROBALANCES”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Interfacial study of the role of SiO 2 on Si anodes using electrochemical quartz crystal microbalance

One of the challenges associated with silicon as an anode material for Li-ion batteries is the formation of an unstable solid-electrolyte interphase which, forms continuously while consuming lithium and other components; and consequently contributes to irreversible capacity. To elucidate some of the details of the formation and subsequent dissolution of species formed during lithiation of silicon anodes we have produced thin film silicon electrodes and analyzed them during lithiation and delithiation using an electrochemical quartz microbalance with in-situ dissipation (EQCM-D). Measurements were conducted on electrodes with silicon alone and silicon with a silicon dioxide coating, and in EC:EMC and EC:DEC:FEC based electrolytes. Mass loss during lithiation was observed in both solvents systems when an oxide layer was present on the surface of the electrode. Solid state and solution NMR measurements indicate that the formation and dissolution of Li2O is the most likely cause of mass loss.

Anodes↗

Label-free real-time acoustic sensing of microvesicle release from prostate cancer (PC3) cells using a Quartz Crystal Microbalance

Highlights: • Microvesiculating cells record loss of mass on a Quartz Crystal Microbalance. • Using the Quartz Crystal Microbalance microvesicles are measured at 0.24 pg. • The QCM-D reveals loss in viscoelastic properties in microvesiculating cells. - Abstract: Using a Quartz Crystal Microbalance with dissipation monitoring, QCM-D (label-free system) measuring changes in resonant frequency (Δf) that equate to mass deposited on a sensor, we showed the attachment, over a 60 min period, of a monolayer of PC3 cells to the gold electrodes of the quartz crystal sensor, which had been rendered hydrophilic. That MVs were released upon BzATP stimulation of cells was confirmed by NTA analysis (average 250 nm diameter), flow cytometry, showing high phosphatidylserine exposition and by fluorescent (Annexin V Alexa Fluor® 488-positive) and electron microscopy. Over a period of 1000s (16.7 min) during which early apoptosis increased from 4% plateauing at 10% and late apoptosis rose to 2%, the Δf increased 20 Hz, thereupon remaining constant for the last 1000s of the experiment. Using the Sauerbrey equation, the loss in mass, which corresponded to the release of 2.36 × 10{sup 6} MVs, was calculated to be 23 ng. We therefore estimated the mass of an MV to be 0.24 pg. With the deposition on the QCM-D of 3.5 × 10{sup 7} MVs over 200s, the decrease in Δf (Hz) gave an estimate of 0.235 pg per MV.

60 APPLIED LIFE SCIENCES↗

Investigating calcite growth rates using a quartz crystal microbalance with dissipation (QCM-D)

Calcite precipitation plays a significant role in processes such as geological carbon sequestration and toxic metal sequestration and, yet, the rates and mechanisms of calcite growth under close to equilibrium conditions are far from well understood. In this study, a quartz crystal microbalance with dissipation (QCM-D) was used for the first time to measure macroscopic calcite growth rates. Calcite seed crystals were first nucleated and grown on sensors, then growth rates of calcite seed crystals were measured in real-time under close to equilibrium conditions (saturation index, SI = log ({Ca 2+ }/{CO 3 2– }/ K sp ) = 0.01–0.7, where {i} represent ion activities and K sp = 10 –8.48 is the calcite thermodynamic solubility constant). At the end of the experiments, total masses of calcite crystals on sensors measured by QCM-D and inductively coupled plasma mass spectrometry (ICP-MS) were consistent, validating the QCM-D measurements. Calcite growth rates measured by QCM-D were compared with reported macroscopic growth rates measured with auto-titration, ICP-MS, and microbalance. Calcite growth rates measured by QCM-D were also compared with microscopic growth rates measured by atomic force microscopy (AFM) and with rates predicted by two process-based crystal growth models. The discrepancies in growth rates among AFM measurements and model predictions appear to mainly arise from differences in step densities, and the step velocities were consistent among the AFM measurements as well as with both model predictions. Using the predicted steady-state step velocity and the measured step densities, both models predict well the growth rates measured using QCM-D and AFM. Furthermore, this study provides valuable insights into the effects of reactive site densities on calcite growth rate, which may help design future growth models to predict transient-state step densities.

58 GEOSCIENCES↗

Effects of compressional waves on the response of quartz crystal microbalance in contact with silicone oil droplets

Droplet quartz crystal microbalance has been demonstrated to be a promising tool for accessing material properties of fluids as well as the diverse solid-fluid interface phenomena. However, a microliter droplet localized on the surface of the electrodes of finite lateral size may cause a nonuniform distribution of the plane velocity, which may lead to surface normal fluid flow and generate the compressional waves above the crystal surface. In the present article, we report systematical investigation on both resonance frequency and dissipation measurements with reference to the small droplets of silicone oils spreading on the surface of the quartz crystal microbalance. Significant cyclical variations in the resonant frequency and resistance of the crystal have been observed as the characteristic sizes of the silicone oil droplets are close to specific values known to favor compressional wave generation. The experimental results have been compared with the theoretical values predicted by the finite element computation associated with a simple hydrodynamic model. Good agreement between theory and experiment has been obtained. The finding indicates that the small droplets on the crystal surface can act as resonant cavities for the compressional wave generation and that the greatest propensity to exhibit periodical resonance behavior in the frequency and dissipation measurements is at droplet height of lambda{sub c}/2 above the crystal surface.

36 MATERIALS SCIENCE↗

Stabilization of sample temperature in a surface-science vacuum chamber to 0.03 K and quartz-crystal microbalance frequency to 0.06 Hz over 0.5 h

Improvements have been made to a high-stability quartz-crystal microbalance for use in a typical surface-science, ultrahigh vacuum chamber, with a frequency stability of one part in 10{sup 8} (0.06 Hz) over 0.5 h. This gives a resolution equivalent to 2% of an atomic monolayer of oxygen over 0.5 h. The quartz-crystal microbalance (QCM) crystal can be rotated to different surface-analysis positions in the chamber. These characteristics open up the combination of surface and bulk adsorption studies on the same sample without transferring the sample to another chamber. To accomplish this, it was necessary to stabilize the sample temperature to {+-}0.03 K over several hours. The oscillator performance is illustrated by the uptake of oxygen by a gold-plated QCM crystal.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Measurement of isosteric heat of gas adsorption and Brunauer–Emmett–Teller (BET) surface area using a quartz crystal microbalance

The study of gas adsorption on a solid surface evaluates the affinity between sorbate gas and sorbent substrate and factors that contribute to this. This report presents a test platform for adsorption experiments of various gases on various solid surfaces. Controlled environmental conditions enable investigations in materials surface science and increase the consistency among adsorption data. The system utilizes a quartz crystal microbalance to perform gravimetric analysis of deposition and adsorption, enabling investigation of the interaction of gaseous molecules with solid surfaces. In this study, a quartz crystal microbalance as gas adsorption detector was integrated with an environmental chamber to create a versatile tool for gas adsorption experiments on thin films. Experimental operation of this apparatus was demonstrated via acquisition of the adsorption isotherms of cyclohexane vapor on a gold surface at 55 and 70 °C. The result indicated International Union of Pure and Applied Chemistry Type II adsorption. Consequentially, application of the Brunauer–Emmett–Teller model to the isotherm data subject to predefined criteria for linear region selection yielded a surface area of the sorbent of 0.53 cm2 at 55 °C. From the monolayer region of the isotherms, the isosteric heat of adsorption of the cyclohexane vapor on gold was calculated to be 37 kJ mol-1.

47 OTHER INSTRUMENTATION↗

Troubleshoot Quartz Crystal Microbalance Measurements Data

We are using a Qpod quartz crystal microbalance (manufactured by Inficon) for use as a low-volume non-volatile residue analysis tool. Inficon has agreed to help troubleshoot some of our measurements and are requesting to view some sample data, which are attached. The basic principle of an NVR analysis is to evaporate a known volume of solvent, and weigh the remaining residue to determine the purity of the solvent. A typical NVR analysis uses 60 g of solvent and can measure residue with an accuracy of +/- 0.01 mg. The detection limit is thus (0.01 mg)/(60 g) = 0.17 ppm. We are attempting to use a quartz crystal microbalance (QCM) to make a similar measurement. The attached data show the response of the QCM as a 5-20 mg drop of solvent evaporates on its surface. The change in mass registered by the QCM after the drop evaporates is the residue that deposits on the crystal. On some measurements, the change in mass in less than zero, which is aphysical since the drop will leave behind ≥0 mass of residue. The vendor, Inficon, has agreed to look at these data as a means to help troubleshoot the cause.

42 ENGINEERING↗

Electron-beam induced electric-hydraulic expansion in a silica-shelled gallium microball-nanotube structure

Heteroshape-heteroscale structure of silica-shelled Ga microball-nanotube was fabricated. Under in situ electron-beam irradiation, an abnormally large and fast expansion of Ga was observed. Failed by a sole routine heating effect of electron-beam, the expansion was explained by an electric-hydraulic expansion effect taking into account a huge inner pressure induced by the repelling Coulomb force of positively charged Ga ions on the Ga microball surface. The ions were accumulated due to knocking-out of Ga electrons under irradiation and shielding effect of a silica shell which prevents the charge balance restoration. A circuit model is proposed to calculate the accumulation of Ga ions.

36 MATERIALS SCIENCE↗

A practical guide to quartz crystal microbalance with dissipation monitoring of thin polymer films

Quartz crystal microbalance with dissipation (QCM-D) monitoring is a powerful tool used to sensitively examine the real-time responses of polymer films to external responses. For example, the technique is commonly used to monitor film growth, material adsorption, thin film swelling, and ion exchange. With its rapidly expanding use, this review is intended to introduce new users to the basic principles of QCM-D, along with practical challenges and remedies specific to polymer thin films. For both new and experienced users, specific case studies are highlighted including layer-by-layer assembly, electrochemical QCM-D, swelling, sensing, and biological application. Finally, the review recommends future directions for research and areas of growth.

36 MATERIALS SCIENCE↗

Examining polymer‐protein biophysical interactions with small‐angle x‐ray scattering and quartz crystal microbalance with dissipation

Abstract Polymer‐protein hybrids can be deployed to improve protein solubility and stability in denaturing environments. While previous work used robotics and active machine learning to inform new designs, further biophysical information is required to ascertain structure–function behavior. Here, we show the value of tandem small‐angle x‐ray scattering (SAXS) and quartz crystal microbalance with dissipation (QCMD) experiments to reveal detailed polymer‐protein interactions with horseradish peroxidase (HRP) as a test case. Of particular interest was the process of polymer‐protein complex formation under thermal stress whereby SAXS monitors formation in solution while QCMD follows these dynamics at an interface. The radius of gyration ( R g ) of the protein as measured by SAXS does not change significantly in the presence of polymer under denaturing conditions, but thickness and dissipation changes were observed in QCMD data. SAXS data with and without thermal stress were utilized to create bead models of the potential complexes and denatured enzyme, and each model fit provided insight into the degree of interactions. Additionally, QCMD data demonstrated that HRP deforms by spreading upon surface adsorption at low concentration as shown by longer adsorption times and smaller frequency shifts. In contrast, thermally stressed and highly inactive HRP had faster adsorption kinetics. The combination of SAXS and QCMD serves as a framework for biophysical characterization of interactions between proteins and polymers which could be useful in designing polymer‐protein hybrids.

60 APPLIED LIFE SCIENCES↗

Hydrogen storage properties of magnesium nanotrees investigated by a quartz crystal microbalance system

We report on enhanced low temperature hydrogen storage properties of magnesium “nanotrees” fabricated by glancing angle deposition (GLAD) method. The arrays of nanotrees and conventional thin films of elemental Mg have been deposited directly onto gold coated unpolished quartz crystal substrates. Mg nanotrees were about 15 μm in height, 10 μm by 1 μm in lateral size, and were composed of “nanoleaves” of about 20 nm in thickness, 2 μm length, and 1 μm width. Hydrogen absorption and desorption properties of Mg nanotrees and thin films were investigated using a quartz crystal microbalance (QCM) testing system that is capable of measuring weight changes with a nanogram sensitivity. QCM absorption tests were performed at temperatures 100, 200, and 300 °C under 30 bars of H 2 pressure. Measurements revealed that Mg nanotrees can absorb hydrogen at significantly higher weight percentage (wt%) and faster rates compared to conventional Mg films under similar conditions. Hydrogen storage of Mg thin film was observed to be at 0.02, 0.30 and 3.91 wt% (weight percentage), while it reached to 1.26, 3.75, and 5.86 wt% for nanotrees at temperatures 100, 200, and 300 °C, respectively, after 150 min. In addition, the results of desorption experiments show that Mg nanotrees can start to release hydrogen at temperatures as low as 100 °C at a rate of 0.11 wt% (vs. 0.01 wt% for thin film at the same temperature) with desorption rates reaching to 1.05 wt% at 200 °C (0.26 wt% for thin film) and 2.57 wt% at 300 °C (1.45 wt% for thin film), which are considerably lower desorption temperatures compared to previously reported values for bulk Mg (>300 °C). The enhancement in hydrogen absorption and desorption properties of Mg nanotrees is believed to originate from their thin and isolated nanoleaves that also have an improved oxidation resistance property.

08 HYDROGEN↗

Elucidating mechanisms of oxide growth and surface passivation on zinc thin film electrodes in alkaline solutions using the electrochemical quartz crystal microbalance

For this study, we utilized electrochemical quartz crystal microbalance to understand electrochemical passivation of the zinc electrode in alkaline media and subsequent oxide growth and stripping. The formation of native zinc oxide on a near pristine Zn surface upon contact with 1 M KOH electrolyte was observed. The surface was seen to roughen with time. During Zn dissolution, the measured mass-charge ratio corresponded to the removal of ZnO and not merely Zn. The mechanism of passivation was determined to be caused by electrochemical etching to form pores. The etching leads to a build-up of solid ZnO and Zn(OH) 2 due to electrochemical reactions on the surfaces of the pores. These reactions functionally close the pores off from the bulk. The cycle of Zn deposition and dissolution develops a porous network, which may be the origin of mossy Zn deposits that plague reversible Zn metal batteries.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Adsorption Study of Al 3+ , Cr 3+ , and Mn 2+ onto Quartz and Corundum using Flow Microcalorimetry, Quartz Crystal Microbalance, and Density Functional Theory

The adsorption of aqueous ions onto natural mineral surfaces controls numerous mineral–water interactions and is governed by, among other numerous factors, ion dehydration and hydrolysis. This work explored the extent to which dehydration and hydrolysis affect the adsorption of three metal cations, Al 3+ , Cr 3+ , and Mn 2+ , onto quartz (SiO2) and corundum (Al 2 O 3 ) surfaces at pH 3.8 through the integration of flow microcalorimetry (FMC), quartz crystal microbalance with dissipation (QCM-D) measurements and density functional theory (DFT) calculations. At pH 3.8, negligible amounts of Mn 2+ and Al 3+ are hydrolyzed, while 78% of Cr 3+ exist in hydrolyzed species. QCM-D and FMC measurements showed that Al 3+ and Cr 3+ adsorb to both surfaces, while Mn 2+ adsorbed only to Al 2 O 3 . DFT bond energy calculations confirmed the favorable bonding between the mineral surfaces and Al 3+ and Cr 3+ , and that Mn 2+ adsorption onto SiO 2 was unfavorable. Furthermore, FMC showed that on both surfaces, the adsorption of Al 3+ was endothermic and reversible, while that of Cr 3+ was exothermic and partially irreversible. Through the integration of experimental and computational methods, this work suggested that the reversible adsorption of unhydrolyzed cations (Mn 2+ and Al 3+ ) occurred through weak electrostatic interactions. The large energy cost required to dehydrate unhydrolyzed cations resulted in an endothermic adsorption process. Meanwhile, hydrolyzed Cr 3+ species can adsorb on quartz and corundum through covalent-bond formation, and thus, their adsorption was partially irreversible. Furthermore, the hydrolysis of Cr 3+ lowered the dehydration energy during adsorption, resulting in an exothermic adsorption. By using bond energies as a guide to indicate the possibility of thermodynamically favored adsorption, there was a strong agreement between the DFT and experimental techniques. The findings presented here contribute to understanding and predicting various mineral–water interfacial processes in the natural environment.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Quartz crystal microbalance-based system for high-sensitivity differential sputter yield measurements

We present a quartz crystal microbalance-based system for high sensitivity differential sputter yield measurements of different target materials due to ion bombardment. The differential sputter yields can be integrated to find total yields. Possible ion beam conditions include ion energies in the range of 30-350 eV and incidence angles of 0 deg. - 70 deg. from normal. A four-grid ion optics system is used to achieve a collimated ion beam at low energy (<100 eV) and a two-grid ion optics is used for higher energies (up to 750 eV). A complementary weight loss approach is also used to measure total sputter yields. Validation experiments are presented that confirm high sensitivity and accuracy of sputter yield measurements.

36 MATERIALS SCIENCE↗