Search NASA⌕ Search

SEARCH · Search NASA

Results for “MICROCHANNEL ELECTRON MULTIPLIERS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Performance studies of atomic layer deposited microchannel plate electron multipliers

Microchannel plate (MCP) photon counting, event timing, imaging detectors have found wide use in astronomical, remote sensing, and biological imaging applications. Novel MCP technology using borosilicate glass microcapillary array substrates functionalized by the application of resistive and secondary emissive layers using atomic layer deposition (ALD) techniques has the potential to outperform traditional MCP technology. Using ALD techniques to functionalize the MCPs allow customization of parameters like gain and resistance independently from the glass substrate. Borosilicate substrates have many advantages over traditional micro-capillary arrays, including low radioactive content, higher open area ratios, low outgassing, and high operational stability. These ALD MCPs can be manufactured in large areas (400 cm 2 ) providing a unique solution for many timing/imaging applications. ALD MCPs can withstand the processing temperatures required for high temperature deposition of III-V materials, such as Gallium Nitride, for UV photocathodes with high quantum efficiencies (QE) in the Near-UV (similar to 100-380 nm). We present the effects of different ALD configurations on the gain (magnitude and uniformity), resistance, imaging, background and detection efficiency, and how these parameters change during lifetime testing. Here, we also present the QE of ALD MCPs and various QE enhancement techniques.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Self-scanned anode array with a microchannel plate electron multiplier - The SSANACON

A photoelectron counting detector utilizing a 128-element linear self-scanned anode array to collect the output of a dual microchannel plate electron multiplier is described. The operation of the detector, its spatial resolution and detection efficiency, and radiation behavior are discussed. The low-noise detector was developed for the Mariner Jupiter/Saturn mission UV spectrometer, and offers a large dynamic range and count rate of 0.003 per anode-sec. It can measure simultaneously two spatially separated signals differing by more than six orders of magnitude in count rate.

Broadfoot, A. L.↗

The Ranicon - A resistive anode image converter

A versatile photon and charged particle imaging system is described. The Ranicon employs a microchannel electron multiplier plate to convert each detected event into a charge signal. This charge pulse is proximity-focused onto a large-area resistive anode plate equipped with pickup electrodes on its edges. Each event is located electronically by the ratios of the charges collected at the edges or by the differences of the signals' risetimes. One- or two-dimensional pictures are built up by storing events digitally (e.g., a core memory) or in analog form (e.g., a storage oscilloscope). Compact laboratory models have been constructed and tested. Operating characteristics, applications, limitations, and advantages of the Ranicon are discussed.

Lampton, M.↗

Resistive anode image converter

The invention of an apparatus for imaging soft X-ray and ultraviolet electromagnetic radiation and charged particles was described. The apparatus includes a pair of microchannel electron multiplier plates connected in a cascaded chevron configuration which intercepts an incident beam of radiation or charged particles. Incident photons or charged particles strike the front surface of the chevron configuration causing emission of electrons. The electrons are accelerated by a voltage gradient and strike the inner side walls of the individual channels, causing emission of secondary electrons. Accelerated and multiplied secondary electrons impinge upon a resistive anode after they transverse the chevron configuration. A pulse position circuit converts the magnitude or transit time of the currents flowing from the point of impact of the electrons on the resistive anode to four contact electrodes mounted on their periphery of the resistive anode into the spatial coordinates of electron impact.

Lampton, M. L.↗

Electro-optical detector for use in a wide mass range mass spectrometer

An electro-optical detector is disclosed for use in a wide mass range mass spectrometer (MS), in the latter the focal plane is at or very near the exit end of the magnetic analyzer, so that a strong magnetic field of the order of 1000G or more is present at the focal plane location. The novel detector includes a microchannel electron multiplier array (MCA) which is positioned at the focal plane to convert ion beams which are focused by the MS at the focal plane into corresponding electron beams which are then accelerated to form visual images on a conductive phosphored surface. These visual images are then converted into images on the target of a vidicon camera or the like for electronic processing. Due to the strong magnetic field at the focal plane, in one embodiment of the invention, the MCA with front and back parallel ends is placed so that its front end forms an angle of not less than several degrees, preferably on the order of 10.degree.-20.degree., with respect to the focal plane, with the center line of the front end preferably located in the focal plane. In another embodiment the MCA is wedge-shaped, with its back end at an angle of about 10.degree.-20.degree. with respect to the front end. In this embodiment the MCA is placed so that its front end is located at the focal plane.

Giffin, Charles E.↗

Comparative Response of Microchannel Plate and Channel Electron Multiplier Detectors to Penetrating Radiation in Space

Channel electron multiplier (CEM) and microchannel plate (MCP) detectors are routinely used in space instrumentation for measurement of space plasmas. Here, our goal is to understand the relative sensitivities of these detectors to penetrating radiation in space, which can generate background counts and shorten detector lifetime. We use 662 keV γ-rays as a proxy for penetrating radiation such as γ-rays, cosmic rays, and high-energy electrons and protons that are ubiquitous in the space environment. We find that MCP detectors are ~20 times more sensitive to 662 keV γ-rays than CEM detectors. This is attributed to the larger total area of multiplication channels in an MCP detector that is sensitive to electronic excitation and ionization resulting from the interaction of penetrating radiation with the detector material. In contrast to the CEM detector, whose quantum efficiency ε γ for 662 keVγ -rays is found to be 0.00175 and largely independent of detector bias, the quantum efficiency of the MCP detector is strongly dependent on the detector bias, with a power law index of 5.5. Lastly, background counts in MCP detectors from penetrating radiation can be reduced using MCP geometries with higher pitch and smaller channel diameter.

79 ASTRONOMY AND ASTROPHYSICS↗

An instrument for rapidly measuring plasma distribution functions with high resolution

An instrument which can rapidly measure plasma particle distribution functions has been developed based upon recent innovations in electrostatic analyzer design and position sensitive particle detection. The new analyzer uses a quadrispherical geometry, but has a completely uniform 360 deg fan-shaped field of view. The polar angular distribution of entering particles is spatially imaged onto a position sensitive detector at the annular exit aperture after a deflection through 90 deg. Several methods of position sensitive detection have been successfully used in conjunction with this analyzer. The simplest is individual channel multipliers spaced around the annular exit. Microchannel plate electron multipliers permit greater position resolution to be obtained, and a detector using microchannel plates followed by a resistive anode image converter obtains angular resolution of about one degree, i.e., 360 individual angle pixels. Instruments of this type were flown on a sounding rocket in early 1982 and will be included on the Giotto comet mission and the AMPTE ion release module (IRM).

Carlson, C. W.↗

Development of two-channel prototype ITER vacuum ultraviolet spectrometer with back-illuminated charge-coupled device and microchannel plate detectors

A vacuum ultraviolet (VUV) spectrometer of a five-channel spectral system is designed for ITER main plasma impurity measurement. To develop and verify the system design, a two-channel prototype system is fabricated with No. 3 (14.4-31.8 nm) and No. 4 (29.0-60.0 nm) among the five channels. The optical system consists of a collimating mirror to collect the light from source to slit, two holographic diffraction gratings with toroidal geometry, and two different electronic detectors. For the test of the prototype system, a hollow cathode lamp is used as a light source. To find the appropriate detector for ITER VUV system, two kinds of detectors of the back-illuminated charge-coupled device and the microchannel plate electron multiplier are tested, and their performance has been investigated.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Time-Resolved Imaging Of Transient Plasma

Pulsed capillary discharge is a compact device that is used to perform fast electrical discharge that is used to produce transient plasma. In this work, a more economical imaging technique is developed in order to study the dynamics of the plasma that is formed in a capillary tube. The imaging system consists of two main devices, a four-frame gated micro-channel plate and a Nikon Coolpix5000 camera. The time-resolved imaging that we have performed in order to study the dynamics of the plasma that is formed in a 10 mm long and 1 mm diameter low pressure capillary tube is reported. The images obtained portrayed that the plasma is heated up when the magnitude of the current is around the maximum and cools down when the current magnitude is around the minimum.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Plasma production by means of discharge in a spherical cavity

The work is devoted to the study of plasma, appearing as a result of cumulation of shock wave with form close to spherical. The shock wave was obtained by triggering of fast discharge (dI/dt about 10{sup 12} A/s) on inner surface of cavity, made from insulator. Spherical cavity with radius 4.5 mm was filled with Ar at 80 Pa. Inductive storage with semiconductive opening switch was used as a current driver. Spherical plasma with diameter about 1 mm, emitting in vacuum ultraviolet (vuv), was detected by means of pinhole measurements with time gated microchannel plate camera, starting about 50 ns from the beginning of the discharge. vuv spectra have shown the presence spectral lines of ArV-ArVIII ions, which gives the estimation of electron temperature as 30 eV. The plasma ball reveals no instabilities, keeps its characteristics and emits vuv radiation during 300 ns. After 600 ns from the beginning of the discharge plasma emits a flux of electrons with energies about 1 keV with temporal structure about 100 ns.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Monte Carlo Simulations of High-speed, Time-gated MCP-based X-ray Detectors: Saturation Effects in DC and Pulsed Modes and Detector Dynamic Range

We present here results of continued efforts to understand the performance of microchannel plate (MCP)–based, high-speed, gated, x-ray detectors. This work involves the continued improvement of a Monte Carlo simulation code to describe MCP performance coupled with experimental efforts to better characterize such detectors. Our goal is a quantitative description of MCP saturation behavior in both static and pulsed modes. We have developed a new model of charge buildup on the walls of the MCP channels and measured its effect on MCP gain. The results are compared to experimental data obtained with a short-pulse, high-intensity ultraviolet laser; these results clearly demonstrate MCP saturation behavior in both DC and pulsed modes. The simulations compare favorably to the experimental results. The dynamic range of the detectors in pulsed operation is of particular interest when fielding an MCP–based camera. By adjusting the laser flux we study the linear range of the camera. These results, too, are compared to our simulations.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Collinear Cluster Tripartition as a Neutron Source--Evaluation of the Setup Parameters

Forthcoming experiments aimed at studying the mechanism of collinear cluster tripartition are planning to be performed with the new facility. Charged products will be registered with the double arm time-of-flight spectrometer composed of mosaics of PIN -diodes and MCP (micro channel plates) based timing detectors. Several tens of {sup 3}He-filled counters will be gathered round the {sup 252}Cf source. In order to choose an optimal configuration of the neutron detector and other parameters of the experiment special modeling has performed using both 'neutron barrel' and known MCNP code. The first test run of the new facility is in progress also its 'neutron skin' in under construction.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Development of a dual MCP framing camera for high energy x-rays

Recently developed diagnostic techniques at LLNL require recording backlit images of extremely dense imploded plasmas using hard x-rays, and demand the detector to be sensitive to photons with energies higher than 50 keV [R. Tommasini et al., Phys. Phys. Plasmas 18, 056309 (2011); G. N. Hall et al., “AXIS: An instrument for imaging Compton radiographs using ARC on the NIF,” Rev. Sci. Instrum. (these proceedings)]. To increase the sensitivity in the high energy region, we propose to use a combination of two MCPs. The first MCP is operated in a low gain regime and works as a thick photocathode, and the second MCP works as a high gain electron multiplier. We tested the concept of this dual MCP configuration and succeeded in obtaining a detective quantum efficiency of 4.5% for 59 keV x-rays, 3 times larger than with a single plate of the thickness typically used in NIF framing cameras.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

High performance techniques for micro channel plate computations in photo multipliers

Monte Carlo - MC methods, requiring heavy computations of large data volume, can be used to predict the amplitude distribution and variance of outputted electron charge in Micro Channel Plates - MCPs, which are fed with primary emitted electrons in their inputs. The concept of parallel and serial combination of separate stages of such stochastic processes, which can be applied in MCP systems and simulated using MC computations, has recently proposed and shown interesting theorems and results. Separating the electron multiplication procedures, occurring in the channels of MCP systems, into sub-procedures, which are similar in nature and occur either in parallel or in consecutive manners, is equivalent to splitting the relevant stochastic system calculations into smaller ones, which can be performed concurrently and/or sequentially. In this way, calculations similar in nature, can be executed only once, thus, eliminating a great percentage of heavy computations. However, when designing and implementing the calculation inferences of the derived theorems using High Performance Computation - HPC techniques, the overall computation cost can further and significantly be reduced. In this paper, the hardware mappings of the relevant theorem inferences onto parallel computing architectures, resulting in circuits of computing blocks for calculation purposes of MCP system stochastic processes, are investigated. Each of the designed and implemented computing circuits corresponds to a theorem inference or to a combination of inferences. The parallelism of the proposed circuits consists of both the concurrent functioning of all the system blocks and of the simultaneous operation of each block, which is processing pieces of data, for many parts of the whole circuit in which it belongs. All the circuits are designed and tested using Altera Quartus II environment and can be implemented as chips, which can be incorporated in computing devices to assist Monte Carlo computations for the estimation of different MCP electron multiplication system performances.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Particle signal considerations for isotope ratio analysis with single particle multi-collector inductively coupled plasma mass spectrometry

Particle analysis has benefitted from the advent of single particle inductively coupled plasma-mass spectrometry (spICP-MS) due to its robustness, sensitivity, and high-throughput nature. Previous methods of spICP-MS have typically utilized quadrupole or time-of-flight mass analyzers and therefore employ electron multiplier-based detectors (such as secondary electron multipliers or microchannel plates). However, to obtain precise measurements on elemental or isotopic ratios within individual particles, multi-collector ICP-MS (MC-ICP-MS) can be used. Here, we investigate Ce isotope ratios, specifically 142 Ce/ 140 Ce, by spMC-ICP-MS using an all-Faraday cup collector array. Using 1 μm (diameter) cerium dioxide particles, integration times of the Faraday cup detectors were varied from 50–500 ms. The signal from the cerium isotopes in the particles was used to determine isotope ratios, which closely matched the expected natural isotopic abundances. Due to the signal decay response from the Faraday cups, the signal from particles lasts much longer than the expected 1–2 ms (up to 100 s of ms). To explore this effect on isotope ratio analysis, multiple ratio analysis methods were used to determine how to obtain optimal precision and accuracy. Relative differences were around 2% for methods that calculated isotope ratios from summing the total signal of an individual particle before calculating the ratio (rather than using every data point individually). It was found that summing all data points per particle, or integrating under the signal peak, yielded both accurate and precise isotope ratios within the particle population. Particles were also sampled off a solid substrate via microextraction, and isotope ratios were determined with relative differences of 0.13% to 9%. This demonstrates the ability to use spMC-ICP-MS to obtain isotope ratios on particles, with little to no relative difference in comparison to the expected ratio, even when operating Faraday detectors at fast 50 ms integration times.

Szakas, Sarah E. [Oak Ridge National Laboratory (O↗

Measurement and modeling of pulsed microchannel plate operation (invited)

Microchannel plates (MCPs) are a standard detector for fast-framing x-ray imaging and spectroscopy of high-temperature plasmas. The MCP is coated with conductive striplines that carry short duration voltage pulses to control the timing and amplitude of the signal gain. This gain depends on the voltage to a large exponent so that small reflections or impedance losses along the striplines can have a significant impact on the position-dependent amplitude and pulse width of the gain. Understanding the pulsed gain response therefore requires careful measurements of the position- and time-dependent surface voltage coupled with detailed modeling of the resulting electron cascade. We present measurements and modeling of the time- and space-dependent gain response of MCP detectors designed for use at Sandia National Laboratories' Z facility. The pulsed gain response is understood through measurements using a high impedence probe to determine the voltage pulse propagating along the stripline surface. Coupling the surface voltage measurements with Monte Carlo calculations of the electron cascade in the MCP provides a prediction of the time- and position-dependent gain that agrees with measurements made on a subpicosecond UV laser source to within the 25% uncertainty in the simulations.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Measurement of heating laser injection time to imploded core plasma by using x-ray framing camera

A simultaneous measurement of imploded core plasma and injection time of heating laser is conducted by using an x-ray framing camera (XFC). The experiments are performed using Gekko XII laser system for implosion of the deuterated polystyrene (CD) plastic shell target and Peta Watt (PW) laser system for heating. The time of PW laser injection is observed as the bright zone in the XFC image. The measured x-ray intensity profiles fit the Gaussian profiles well. The calculations of microchannel plate by using dynode model explain these broadened temporal profiles qualitatively. The peak position of fitted x-ray intensity profile is almost in agreement with the time when the high energy x ray is observed by x-ray streak camera. Moreover, the peak position is delayed corresponding to the delayed setting of PW laser injection time. From these results, it is concluded that we can estimate the heating laser injection time with resolution of the order of 10 ps by using XFC.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗